§ 169.559 - Fire pumps.  


Latest version.
  • § 169.559 Fire pumps.

    (a) Each sailing school vessel must be equipped with fire pumps as required in Table 169.559(a).

    Table 169.559(a) - Fire Pumps

    Length Exposed and partially protected water service Protected water service
    65 feet but less than 90 feet 1 1 0
    90 feet but less than 120 feet 2 1 1 1
    120 feet or greater 3 2 1 1

    (b) Fire pump capacity must be in accordance with the following:

    Vessel length Minimum capacity
    Less than 90 ft 5.5 m3/hr (25 gpm).
    90 feet but less than 120 ft 11.0 m3/hr (50 gpm).
    Greater than 120 ft 14.3 m3/hr (66.6 gpm).

    (c) Each fire pump must be fitted with a pressure gage on the discharge side of the pump.

    (d) Each vessel must have a hand operated portable fire pump having a capacity of at least 1.1 m3/hr (5 gpm). This pump must be equipped with suction and discharge hose suitable for use in firefighting.