§ 171.073 - Treatment of stepped and recessed bulkheads in Type II subdivision.  


Latest version.
  • § 171.073 Treatment of stepped and recessed bulkheads in Type II subdivision.

    (a) A main transverse watertight bulkhead may not be stepped unless additional watertight bulkheads are located as shown in Figure 171.067(a) so that the distances A, B, C, and D illustrated in Figure 171.067(a) comply with the following:

    (1) A and B must not exceed the maximum bulkhead spacing that permits compliance with § 171.070; and

    (2) C and D must not be less than the minimum spacing specified in § 171.070(e).

    (b) A main transverse watertight bulkhead may not be recessed unless all parts of the recess are inboard from the shell of the vessel as illustrated in Figure 171.067(c).

    (c) If a main transverse watertight bulkhead is recessed or stepped, an equivalent plane bulkhead must be used in the calculations required by § 171.070.