Code of Federal Regulations (Last Updated: May 6, 2024) |
![]() |
Title 46 - Shipping |
![]() |
Chapter I - Coast Guard, Department of Homeland Security |
![]() |
SubChapter S - Subdivision and Stability |
![]() |
Part 171 - Special Rules Pertaining to Vessels Carrying Passengers |
![]() |
Subpart C - Subdivision and Damage Stability |
§ 171.073 - Treatment of stepped and recessed bulkheads in Type II subdivision.
Latest version.
-
§ 171.073 Treatment of stepped and recessed bulkheads in Type II subdivision.
(a) A main transverse watertight bulkhead may not be stepped unless additional watertight bulkheads are located as shown in Figure 171.067(a) so that the distances A, B, C, and D illustrated in Figure 171.067(a) comply with the following:
(1) A and B must not exceed the maximum bulkhead spacing that permits compliance with § 171.070; and
(2) C and D must not be less than the minimum spacing specified in § 171.070(e).
(b) A main transverse watertight bulkhead may not be recessed unless all parts of the recess are inboard from the shell of the vessel as illustrated in Figure 171.067(c).