Code of Federal Regulations (Last Updated: July 5, 2024) |
![]() |
Title 46 - Shipping |
![]() |
Chapter I - Coast Guard, Department of Homeland Security |
![]() |
SubChapter T - Small Passenger Vessels (Under 100 Gross Tons) |
![]() |
Part 183 - Electrical Installation |
![]() |
Subpart E - Miscellaneous Systems and Requirements |
§ 183.530 - Hazardous areas.
Latest version.
-
§ 183.530 Hazardous areas.
(a) Electrical equipment in spaces containing machinery powered by, or fuel tanks for, gasoline or other fuels having a flashpoint of 43.3 °C (110 °F) or lower must be explosion-proof or ignition-protected, or be part of an intrinsically safe system.
(b) Electrical equipment in lockers used to store paint, oil, turpentine, or other flammable liquids must be explosion-proof or be part of an intrinsically safe system.
(c) Explosion-proof equipment and intrinsically safe systems must meet the requirements of § 111.105 in subchapter J of this chapter.
[CGD 85-080, 61 FR 997, Jan. 10, 1996; 61 FR 24465, May 15, 1996]