![]() |
Code of Federal Regulations (Last Updated: July 5, 2024) |
![]() |
Title 46 - Shipping |
![]() |
Chapter I - Coast Guard, Department of Homeland Security |
![]() |
SubChapter D - Tank Vessels |
![]() |
Part 32 - Special Equipment, Machinery, and Hull Requirements |
![]() |
Subpart 32.56 - Structural Fire Protection for Tank Ships With a Keel Laying Date On or After January 1, 1975 |
§ 32.56-50 - Combustible veneers - T/ALL.
Latest version.
-
§ 32.56-50 Combustible veneers - T/ALL.
(a) Except as provided in paragraph (b) of this section combustible veneers on bulkheads, linings, and ceilings within accommodation, service, or control spaces must be 2 millimeters (.079 inches) or less in thickness.
(b) Veneers on bulkheads, linings, and ceilings in concealed spaces, corridors, stairway enclosures, or control spaces must be an approved interior finish material or a reasonable number of coats of paint.