01-13836. Harmonization with the United Nations Recommendations, International Maritime Dangerous Goods Code, and International Civil Aviation Organization's Technical Instructions  

  • Start Preamble Start Printed Page 33316

    AGENCY:

    Research and Special Programs Administration (RSPA), DOT.

    ACTION:

    Final rule.

    SUMMARY:

    This final rule amends the Hazardous Materials Regulations (HMR) to maintain alignment with international standards by incorporating various changes to proper shipping names, hazard classes, packing groups, special provisions, packaging authorizations, air transport quantity limitations and vessel stowage requirements. In addition, this final rule revises the requirements for intermediate bulk containers and UN portable tanks for alignment with international requirements. Because of recent changes to the International Maritime Dangerous Goods Code (IMDG Code), the International Civil Aviation Organization's Technical Instructions for the Safe Transport of Dangerous Goods by Air (ICAO Technical Instructions), and the United Nations Recommendations on the Transport of Dangerous Goods (UN Recommendations), these revisions are necessary to facilitate the transport of hazardous materials in international commerce.

    DATES:

    Effective Date: The effective date of these amendments is October 1, 2001.

    Voluntary Compliance Date: With the exceptions of the ICAO Technical Instructions, 2001-2002 Edition and the International Atomic Energy Agency's (IAEA) Regulations for the Safe Transport of Radioactive Material, No. TS-R-1, which are authorized for use on July 1, 2001, RSPA is authorizing immediate voluntary compliance. However, persons voluntarily complying with these regulations should be aware that petitions for reconsideration may be received and as a result of RSPA's evaluation of those petitions, the amendments adopted in this final rule could be subject to further revision.

    Delayed Compliance Date: Unless otherwise specified, compliance with the amendments adopted in this final rule is required beginning on October 1, 2002.

    Incorporation by Reference Date: The incorporation by reference of publications listed in these amendments in § 171.7 has been approved by the Director of the Federal Register as of October 1, 2001.

    Start Further Info

    FOR FURTHER INFORMATION CONTACT:

    Joan McIntyre, Office of Hazardous Materials Standards, telephone (202) 366-8553, or Bob Richard, Assistant International Standards Coordinator, telephone (202) 366-0656, Research and Special Programs Administration, U.S. Department of Transportation, 400 Seventh Street, SW., Washington, DC 20590-0001.

    End Further Info End Preamble Start Supplemental Information

    SUPPLEMENTARY INFORMATION:

    I. Background

    On October 23, 2000, the Research and Special Programs Administration (RSPA) (hereafter, “we” and “our” means “RSPA”) published a notice of proposed rulemaking (NPRM) (65 FR 63294) under Docket HM-215D. The NPRM proposed changing the Hazardous Materials Regulations (HMR), 49 CFR parts 171-180, based on the UN Recommendations, the IMDG Code and the ICAO Technical Instructions with respect to hazard communication, classification, and packaging requirements. The intended effect of the rule was to facilitate the international transportation of hazardous materials by ensuring a basic consistency between the HMR and international regulations, while at the same time ensuring the safe transportation of hazardous materials.

    On February 1, 2001, we published a final rule under Docket HM-215D (66 FR 8644) authorizing the use of the updated editions of the IMDG Code, the UN Recommendations and the UN Recommendations Manual of Tests and Criteria as proposed in the October 23, 2000 NPRM. This final rule addresses all other proposals published in the NPRM.

    The UN Recommendations are not regulations, but are recommendations issued by the UN Committee of Experts on the Transport of Dangerous Goods. These recommendations are amended and updated biennially by the UN Committee of Experts. They serve as the basis for national, regional, and international modal regulations (specifically, the IMDG Code, issued by the International Maritime Organization (IMO), and the ICAO Technical Instructions, issued by the ICAO Dangerous Goods Panel). In 49 CFR 171.12, the HMR authorize hazardous materials shipments prepared in accordance with the IMDG Code if all or part of the transportation is by vessel, subject to certain conditions and limitations. In § 171.11, subject to certain conditions and limitations, the HMR authorizes the offering, acceptance and transport of hazardous materials by aircraft, in conformance with the ICAO Technical Instructions, and by motor vehicle either before or after being transported by aircraft.

    On December 21, 1990, we published a final rule based on the UN Recommendations (Docket HM-181; 55 FR 52402) which comprehensively revised the Hazardous Materials Regulations (HMR), 49 CFR parts 171 to 180, for harmonization with international standards. Since publication of the 1990 final rule, we have issued three additional international harmonization final rules, (Dockets HM-215A, 59 FR 67390; HM-215B, 62 FR 24690; and HM-215C, 64 FR 10742). The rules provided additional harmonization with international air and sea transportation requirements by more fully aligning the HMR with the corresponding biennial updates of the UN Recommendations, the IMDG Code and the ICAO Technical Instructions.

    The continually increasing amount of hazardous materials transported in international commerce warrants the harmonization of domestic and international requirements to the greatest extent possible. According to the American Chemistry Council, exports of chemicals totaled almost $80 billion in the year 2000, while imports totaled nearly $74 billion. Harmonization serves to facilitate international transportation and at the same time ensures the safety of people, property and the environment.

    While the intent of the harmonization rulemakings is to align the HMR with international standards, we review and consider each amendment on its own merit. Each amendment is considered on the basis of the overall impact on transportation safety and the economic implications associated with its adoption into the HMR. Our goal is to harmonize without sacrificing the current HMR level of safety and without imposing undue burdens on the regulated public.

    In our efforts to continue the alignment of the HMR with international requirements, this final rule makes changes to the HMR based on the eleventh revised edition of the UN Recommendations, Amendment 30 to the IMDG Code, which became effective January 1, 2001; and, the 2001-2002 ICAO Technical Instructions Start Printed Page 33317which becomes effective July 1, 2001. Petitions for rulemaking pertinent to harmonization with international standards and the facilitation of international transportation are also addressed in this final rule and serve as the basis of certain amendments. Other amendments are based on feedback from the regulated industry, other DOT modal administrations and our initiative. Included are a few editorial clarifications. Certain commenters raised nonregulatory issues, issues that are beyond the scope of this rulemaking or suggested revisions that are now impractical (such as correcting the spelling of an entry that we removed). Such comments will not be addressed. Unless otherwise stated, the revisions are for harmonization with international standards.

    II. Overview of Changes in This Final Rule

    (See specific section for discussion of comments.)

    Amendments to the HMR in this final rule include:

    —Incorporation by reference of the updated ICAO Technical Instructions and addition of incorporation by reference of five current standards which include an International Atomic Energy Agency (IAEA) safety standard, three International Organization for Standardization (ISO) standards and one American Society for Testing Materials (ASTM) standard.

    —Amendments to the Hazardous Materials Table (HMT) which add, revise or remove certain proper shipping names, hazard classes, packing groups, special provisions, packaging authorizations, bulk packaging requirements, and passenger and cargo aircraft maximum quantity limitations. Proper shipping name amendments include replacing the word “inhibited” with “stabilized.” Entry removals include certain domestic entries for which corresponding UN entries are currently included in the HMT.

    —Revision of vessel stowage category definitions and codes for Class 1 (explosive) materials.

    —Revision of shipping paper requirements for sea transport.

    —Addition, removal and revision of certain entries to the List of Marine Pollutants.

    —Addition, removal and revision of special provisions, including removal of current T codes and IBC bulk provisions, and addition of UN portable tank codes and IBC special packing provisions consistent with those in the UN Recommendations.

    —Removal of the requirement to distinguish between primary and subsidiary risk labels and placards.

    —Addition and revision to the list of organic peroxides and the list of self-reactive substances.

    —Revision of the requirements pertaining to the transportation of samples.

    —Revision of intermediate bulk container (IBC) requirements including amendments to the IBC commodity sections in §§ 173.240, 173.241, 173.242, 173.243 and 173.247, and addition of UN IBC packing instructions and special IBC packing provisions in part 172.

    —Incorporation of the design, construction and use requirements for UN portable tanks.

    —Consolidation of current portable tank maintenance, approval and use requirements.

    —Inclusion of flexible grandfather provisions for the continued use of IM 101, IM 102, DOT 51, DOT 57 and DOT 60 portable tanks.

    —Removal of specifications for DOT 52 and 53 portable tanks and the provisions for their continued use.

    —Incorporation of a provision for the use of the “W” mark for IBCs.

    —Revision of minimum thickness requirements for metal IBCs.

    —Revision of several explosive packing methods to allow a broader selection of authorized packagings.

    —Revision of provisions for cigarette lighters and alcoholic beverages carried aboard aircraft.

    —Revision of the segregation table for hazardous materials stowed on aircraft.

    —Allowance of the display of only one placard when certain explosive compatibility groups are transported together.

    —Revision of lithium battery requirements.

    III. Summary of Regulatory Changes by Section

    Part 171

    Section 171.7. We are updating the incorporation by reference for the ICAO Technical Instructions, and adding an ASTM standard, the current edition of the IAEA safety standard and three ISO standards as specified below. Amendment 30 to the IMDG Code, the eleventh revised edition of the UN Recommendations and the third revised edition of the UN Recommendations Manual of Tests and Criteria were incorporated into the HMR in a final rule under Docket HM-215D published February 1, 2001 (66 FR 8644) with a voluntary compliance date authorized as of January 1, 2001. One commenter opposed incorporation by reference of ASTM's E-112-96 Standard for Test Methods for Determining Average Grain Size,” and ISO's 1496-3 “Series 1 freight containers—Specification and testing,” 1996 edition; 4126-1 “Safety valves-Part 1: General Requirements,” 1991 edition, and 6892 “Metallic materials—Tensile testing,” 1984 edition. According to the commenter, the industry supports the use of voluntary consensus standards in commercial applications, however, because of the “frequency of change” and because industry does not adopt the standards verbatim, the commenter suggests that these standards be used as guidance. We disagree. The “National Technology Transfer and Advancement Act of 1995” directs agencies to use voluntary consensus standards. According to the Office of Management and Budget (OMB), Circular A-119, “Federal Participation in the Development and Use of Voluntary Consensus Standards and in Conformity Assessment Activities,” government agencies must use voluntary consensus standards wherever practical in the development of regulations. Agency adoption of industry standards promotes productivity and efficiency in government and industry, expands opportunities for international trade, conserves resources, improves health and safety and protects the environment. Furthermore, requirements in the industry consensus standards are not required to be applied on a mandatory basis unless specifically referenced as such. When incorporating standards in the HMR, we typically specify the specific requirements in the standard that must be met. Requirements that are not mandated in adopted standards are rarely imposed on a mandatory basis in RSPA rulemaking initiatives. On this basis, we are incorporating the standards as proposed.

    For international shipments of radioactive material, we are adopting the International Atomic Energy Agency (IAEA) safety standards, “Regulations for the Safe Transport of Radioactive Material, No. TS-R-1” with restrictions for its use for the domestic portion of the transport. Additionally, we are retaining Safety Series No. 6 with the same restrictions. As explained previously, TS-R-1 is the updated edition of the current Safety Series No. 6. Under this final rule, domestic shipments remain subject to the HMR requirements which are based on Safety Series No. 6. For domestic use, a proposal to adopt some or all of the TS-Start Printed Page 33318R-1 standards will be addressed under a separate rulemaking, Docket HM-230, which will provide discussion and opportunity for comment.

    As discussed in the final rule under Docket HM-215D published on February 1, 2001, we received comments supporting and opposing the incorporation by reference of TS-R-1 into the HMR. We received several comments from industry supporting the incorporation of TS-R-1 including requests for expedited publication of this final rule. Shippers will be required to comply with the TS-R-1 standards for export shipments and failure to comply would result in foreign authorities refusing to accept hazardous materials shipments prepared in accordance with the HMR. Several commenters stressed the importance of a timely compliance date to allow for a reasonable period to implement the TS-R-1 standards and the ICAO Technical Instructions, which both become effective on July 1, 2001. One commenter pointed out that not only does the time element greatly inhibit the preparation of packagings when nearing the July 1, 2001 effective date, but it will also have an impact on packagings already in transit. One commenter stated that failure to adopt TS-R-1 for international shipments will result in serious health treatment implications because radioisotope pharmaceutical products that are necessary for such treatment would be frustrated in transportation.

    As discussed in the February 1, 2001 final rule, we received many comments from private citizens and local citizen groups opposing the incorporation of TS-R-1. Some of these commenters also opposed the adoption of the updated editions of the IMDG Code and the ICAO Technical Instructions because both incorporate TS-R-1. (The IMDG Code was adopted in the February 1, 2001 final rule.) Most of the commenters stated that TS-R-1 lowers the level of safety for the transportation of radioactive materials and thereby poses hazards to the public, however many of these commenters did not provide any technical basis for their opposition. The comments included claims that the TS-R-1 standards for Type B packagings are “weakened.” As discussed in the February 1, 2001 final rule, the commenters are incorrect. The TS-R-1 standards strengthen Type B packagings by adding immersion and crush testing to the previously required performance tests. Furthermore, the standards also add limits on the contents of Type B packaging when being transported by aircraft. Some commenters claimed that uranium hexafluoride packaging requirements are “weakened” in TS-R-1. These commenters are also incorrect. The criticality requirements for packages containing uranium hexafluoride did not change.

    Many of the commenters stated that TS-R-1's revised definition of radioactive material lowers the level of safety by changing the 70Bq/g activity concentration threshold. The revised radioactive material definition will be addressed under Docket HM-230 and is not adopted in this final rule. We are adding a paragraph to §§ 171.11 and 171.12 to clarify that only the current definition of radioactive material applies. In addition, we are maintaining the current provisions in §§ 171.11 and 171.12, including the values for Type A packaging contents. Shippers using TS-R-1 under the ICAO Technical Instructions or the IMDG Code must conform to the provisions and restrictions as set forth in §§ 171.11 and 171.12, respectively.

    Based on the above, the incorporation by reference materials adopted in this final rule are as follows:

    —The ICAO Technical Instructions—2001-2002 edition.

    —ASTM's “E 112-96 Standard for Test Methods for Determining Average Grain Size” is added to define “fine grain steel” as included in the proposed incorporation of the UN portable tank specifications in § 178.274.

    —IAEA's current “Regulations for the Safe Transport of Radioactive Material, No. TS-R-1,” 1996 edition is added while retaining the previous edition entitled, “Regulations for the Safe Transport of Radioactive Material, Safety Series No. 6.” The TS-R-1 requirements were incorporated into the IMDG Code which became effective on a voluntary basis on January 1, 2001 and the ICAO Technical Instructions which will be effective July 1, 2001.

    —Finally, we are adding three ISO standards to coincide with the incorporation of the UN portable tank requirements. The standards are as follows: “ISO 1496-3 Series 1 freight containers—Specification and testing,” 199 edition; “ISO 4126-1 Safety valves-Part 1: General Requirements,” 1991 edition; and, “ISO 6892 Metallic materials—Tensile testing,” 1984 edition.

    In the NPRM, we proposed to add IMO'S current “International Code for the Safe Carriage of Packaged Irradiated Nuclear Fuel, Plutonium and High-Level Radioactive Wastes on Board Ships' (INF Code). Because the IMO Maritime Safety Committee adopted the INF Code for incorporation into the 2000 edition of the IMDG Code, which we authorized under Docket HM-215D (66 FR 8644) on February 1, 2001, we are not adding the INF Code separately under § 171.7. Also see §§ 176.2 and 176.720.

    Section 171.8. We are adding four new definitions to § 171.8. “Large packaging” is added to correspond with the addition of an approval provision that allows the use of large packagings which comply with requirements in the UN Recommendations (see § 178.801(i)). Large packagings are UN-marked bulk packagings which are very similar to IBCs, with the exception that they contain inner packagings. In the NPRM, we proposed to add a definition for “Liner.” After reconsideration, we believe that this definition is overly restrictive because it would preclude the use of liners such as those used in portable tanks, (for example, lead or rubber liner materials), bulk bins, IBCs and other types of packagings and the proposed definition would limit liners to bags and tubes. Plastic sheeting, rotationally molded rubber lining and other types of liners that are not bags or tubes would be excluded because the proposed definition limited liners to bags and tubes. On this basis, we are not incorporating the definition for “Liner.” “Stabilized” is added in conjunction with the proposal to replace the word “inhibited” with “stabilized” in proper shipping names (see § 172.101). Finally, “UN portable tank” is added in conjunction with the requirements for the design, construction and use of UN portable tanks (see §§ 178.274, 178.275, 178.276 and 178.277).

    Section 171.10. To correspond with the incorporation of the UN portable tank specifications, we are adding the unit of measure for “Newton” into the Table of Conversion Factors in paragraph (c)(2).

    Section 171.11. We are adding a new paragraph (d)(6)(vi) to limit the radioactive material definition to § 173.403. We are also adding a new paragraph (d)(17) to ensure conformance with the current approval provision in § 173.128(d) which requires an approval from the Associate Administrator for the offering for transportation or transport of organic peroxides that are not identified by technical name in the § 173.225(b) Organic Peroxide Table.

    Section 171.12. In the NPRM, we proposed to revise paragraph(b)(3) by adding a limitation to the use of the IMDG Code, 2000 edition that became effective January 1, 2001. The limitation which regulates certain viscous flammable liquids that are excepted from the IMDG Code was incorporated Start Printed Page 33319into the HMR on February 1, 2001 (66 FR 8646). One commenter stated that we should revise paragraph (b)(5) by removing the reference to Section 26 of the General Introduction to the IMDG Code because it will become obsolete January 1, 2002 (66 FR 8645) due to the extensive reformatting. We agree and are making the revision accordingly. We are also revising the paragraph to allow for the use of IBCs and UN portable tanks intended for liquids and solids that conform to the requirements of the IMDG Code. We are adding a new paragraph (b)(19) to ensure conformance with the current approval provision in § 173.128(d), which requires an approval from the Associate Administrator for the offering for transportation or transport of organic peroxides that are not identified by technical name in the § 173.225(b) Organic Peroxide Table. In addition, we are revising paragraph (d) to reflect the addition of the current edition of the IAEA “Regulations for the Safe Transport of Radioactive Material, No. TS-R-1,” 1996 edition. (See § 171.7 for discussion concerning the addition of the updated TS-R-1 standards) to ensure that radioactive material is defined in accordance with § 173.403.

    Section 171.12a. We are adding a new paragraph (b)(18) to ensure conformance with the current approval provision in § 173.128(d) which requires an approval from the Associate Administrator for the offering for transportation or transport of organic peroxides that are not identified by technical name in the § 173.225(b) Organic Peroxide Table.

    Section 171.14. We are revising paragraphs (d) and (d)(1) to authorize a delayed implementation date for the amendments adopted in the HM-215D final rule. The effective date of this final rule is October 1, 2001. However, we are authorizing immediate voluntary compliance. This authorization will allow shippers to prepare their international shipments in accordance with the new ICAO Technical Instructions, the IMDG Code and the HMR provisions. We also are authorizing a delayed mandatory compliance date of October 1, 2002 which is comparable to the transition provision provided in the final rule under Docket HM-215C. The delayed mandatory compliance date will offer sufficient time to implement the new provisions and deplete current stocks of shipping papers, labels, placards and packagings affected by the new requirements.

    We are revising paragraph (d)(2) to permit intermixing of old and new (HM-215D) hazard communication requirements until October 1, 2002.

    We are adding a new paragraph (d)(4) to allow the use of the T code special provisions (assigned to certain hazardous materials in Column (7) of the HMT) in effect on December 31, 2000 until January 1, 2010 for hazardous materials offered for transportation in IM, DOT Specification 51 and IMO portable tanks. This amendment is consistent with the IMDG Code grandfather provisions for portable tank requirements and will minimize any undue regulatory burden.

    We are adding a new paragraph (d)(5) to allow continued display of proper shipping names with the word “inhibited” on packagings until October 1, 2005. (See § 172.101, HMT for further discussion.)

    Part 172

    Section 172.101. Paragraph (b)(1) is being revised for clarification of the use of the plus (+) sign. (See preamble discussion later in this section under the Hazardous Materials Table (HMT). We are revising paragraph (c)(11) for materials transported as samples which are assigned a tentative proper shipping name, hazard class, identification number and packing group. We are adding provisions based on the eleventh revised edition of the UN Recommendations to include requiring the word “SAMPLE” to appear in the proper shipping name, requiring a combination packaging, limiting the packaging size to 2.5 kg and allowing an exception from including the technical name when the constituents are not known. We also are adding a new paragraph (c)(16) to allow for the inclusion of the qualifying words “liquid,” “solid” or “molten,” as applicable, to a proper shipping name.

    We received several comments concerning our proposal to revise hazardous materials transported as samples. Some commenters stated that prohibiting samples from being packed together with other hazardous materials would be overly restrictive and impose an undue burden. Commenters presented examples to demonstrate their argument, including one scenario in which a hazardous material is transported on dry ice. Our intention for revising this paragraph is to prevent the dangerous mixing of materials as prohibited in § 173.24 and to prevent the production of a mixture that would result in violation of § 173.21. Because the HMR requires samples to meet the requirements in §§ 173.21, 173.24, 173.24a and 173.24b, we agree that it is not necessary to prohibit samples from being shipped in the same packaging with other hazardous materials and are revising the paragraph accordingly. We are also removing proposed paragraph (c)(11)(i) in response to commenters' objections to the proposal prohibiting an explosive, infectious substance or radioactive material from being shipped as a sample. Provisions for transporting samples of such materials are currently authorized in the HMR and we agree that incorporation of the proposed paragraph (c)(11)(i) would be contrary to the current provisions. It was not our intention to remove the authorization to transport these materials as samples. As a result of these changes, certain proposed paragraphs are renumbered.

    One commenter requested that the word “SAMPLE” be allowed to be shown on the shipping paper in association with the basic description. That is our intent, and although we proposed to require the word “SAMPLE” to appear in association with the basic description in the NPRM's preamble, the regulatory text wording required the “SAMPLE” to be shown before the basic description. The commenter is correct and we are revising the regulatory text accordingly.

    One commenter requested that we change the term “hazardous waste” to “waste” because in accordance with § 171.8 the term “hazardous waste” applies only to those materials subject to the EPA manifest requirements under 40 CFR part 262. The commenter is concerned that generators of waste not subject to the EPA manifest requirements would be restricted from transporting their materials as samples. The commenter is incorrect by misapplying the use of the term “generators of waste” and “hazardous waste.” Under the CFR, the term “hazardous waste” does not apply to hazardous materials that are not subject to the EPA manifest requirements. Such materials are considered “a sample of material” in the context of paragraph (c)(11) and are not considered “waste” under the 49 CFR.

    Finally, based on comments recommending various revisions to clarify the intent of the paragraph (c)(11), we made certain editorial amendments, including clarifying that technical descriptions do not apply when the primary constituents for which the tentative classification is based are not known.

    In paragraph (k) for vessel stowage requirements in Column (10) of the HMT, we are adding new paragraphs (k)(6) through (k)(20) to include the IMDG Code vessel stowage category definitions for Class 1 (explosive) materials. This action is consistent with the new stowage categories and terminology contained in Amendment 30 of the IMDG Code. (Also see Start Printed Page 33320preamble discussion under “The Hazardous Materials Table” and § 176.63.)

    The Hazardous Materials Table (HMT). Amendments to the HMT include the following:

    —Several commenters noted minor editorial errors in the HMT and we made the appropriate changes to correct these entries.

    —For the entries, “Other regulated substances, liquid, n.o.s.” and “Other regulated substances, solid, n.o.s.,” we are adding the letter “G” to Column (1). The letter “G,” which denotes the n.o.s. and generic proper shipping names which are required to be supplemented with the technical names of the hazardous material (in parentheses and in association with the basic description), was inadvertently omitted in Docket HM-215C (64 FR 10742).

    One commenter requested that we allow marine pollutants to alternatively be described using the proper shipping names “Other regulated substances, liquid, n.o.s.” or “Other regulated substances, solid, n.o.s,” as appropriate. We are not adopting this requested amendment because the shipping names “Environmentally hazardous substances, liquid, n.o.s.” and “Environmentally hazardous substances, solid, n.o.s” more accurately describe marine pollutants as posing an environmental risk and are, therefore, more appropriate proper shipping names as required by the HMR.

    —We are adding the following new entries: “Nitroglycerin mixture, desensitized, liquid, n.o.s. with not more than 30% nitroglycerin by mass,” UN3357; “Propellant, solid,” UN0501; “Refrigerating machines containing flammable, non-toxic, liquefied gas,” UN3358; “Rockets with inert head,” UN0502; and “1H-Tetrazole,” UN0504.

    —We are revising the entry, “Dangerous Goods in Machinery or Dangerous Goods in Apparatus” by replacing the identification number NA8001 with UN3363, designating a Class 9 assignment and revising Special Provision 136 (see § 172.102). These changes reflect the adoption of the entry by the UN Committee of Experts and amendments agreed to by the ICAO Dangerous Goods Panel. The entry was added to the HMT under Docket HM-215C as NA8001 and assigned Special Provision 136 to prescribe the appropriate hazard class assignment. As explained in HM-215C, the entry was adopted in the ICAO Technical Instructions to provide an exception from the UN packaging performance tests for equipment, machinery or apparatus containing small quantities of hazardous materials. For machinery or apparatus not specifically listed in the HMT, the entry provides a practical means of describing and transporting machinery or apparatus containing small quantities of hazardous materials. In HM-215C, we stated that upon the assignment of a UN identification number, we would revise the entry accordingly. This was accomplished in the eleventh revised edition of the UN Recommendations in which UN3363 was assigned and this entry was assigned to Class 9. The ICAO Technical Instructions were amended consistent with this UN decision. Therefore, based on the above discussion, we are revising the entry, “Dangerous Goods in Machinery or Dangerous Goods in Apparatus” by assigning it to Class 9, replacing the domestic identification number with an international identification number, and revising Special Provision 136.

    —We are adding the entry “Air bag inflators, pyrotechnic or Air bag modules, pyrotechnic or seat-belt pretensioners, pyrotechnic,” UN0503 for air bags that are classified as Division 1.4G. We inadvertently omitted this entry in the NPRM. While we are not considering changing our policy or procedures for the classification of air bags as articles of Class 9, on the basis of the UN Manual of Tests and Criteria, 6c test, we believe that other competent authorities may assign a classification of 1.4G for some air bags. Incorporation of this entry is necessary to preclude the potential for frustrated shipments, the need to re-mark certain packagings or to change shipping papers for these air bags, when they are classified as 1.4G by other competent authorities and are being transported to or from the United States.

    —We are revising all proper shipping names containing the word “inhibited” by replacing “inhibited” with the word “stabilized.” (Also, see the added definition for “stabilized” in § 171.8.) One commenter opposed the proposal to replace the word “inhibited” with “stabilized” and suggested that, instead, we clarify that monomers can be properly inhibited through means other than the addition of an inhibitor. The commenter stated that the words “inhibited” and “stabilized” have the same meaning for the purpose of transportation and expressed concern that we do not understand the distinction between the two words. The commenter also requested that we add several generic n.o.s. entries that include the word “inhibited” in the proper shipping names. We are not convinced of the merits of either request. The word “stabilized” introduces internationally accepted and standardized hazard communication wording and conveys that the addition of a stabilizing compound or other means of stabilization such as temperature control measures, have been implemented to prevent an unwanted reaction of a hazardous material. The word “stabilized” conveys a broader meaning of inhibiting uncontrolled reaction of a hazardous material (see § 171.8) by different methods. The continued use of the word “inhibited” would lead to a dual system of hazard communication that would be burdensome to shippers and carriers. In addition, the word “stabilized” is more adequately descriptive from the emergency responders' perspective. Adopting the word “stabilized” will also alleviate the necessity of issuing numerous exemptions for the variety of methods or combination of methods used to inhibit uncontrolled reactions without the use of inhibiting chemicals. Based on these reasons, we are adopting the amendment as proposed.

    One commenter requested that we extend the proposed transition period for this amendment to provide sufficient relief from remarking all affected bulk packagings. The commenter stated that an extended transition period would allow the remarking to be accomplished during routine maintenance and periodic inspection cycles. In the NPRM, we proposed a transition period until October, 2002. We agree that a longer transition period for domestic transportation would help relieve any undue burden associated with this amendment without having a significant impact on safety. We are including a transitional provision in § 171.14 to allow the use of the word “inhibited” to be shown on packagings until October 1, 2005.

    The allowance of additional means of stabilization and the removal of certain domestic entries from the HMT (see domestic entry removals later in this section) also addresses a petition for rulemaking (P-1304) requesting that we add a new domestic entry, “Methyl methacrylate monomer, uninhibited,” Class 3, NA1247, PG II to the HMT. As we stated, with respect to the request that we add generic n.o.s. entries that include the word “inhibited,” such an Start Printed Page 33321action would also be contrary to the intent of global harmonization and would be beyond the scope of this rule. We are not adopting the request. Commenters having an interest in developing generic names for inclusion into the UN Recommendations should provide more specific information and examples of materials that require stabilization and are not covered by existing entries.

    —We are revising the following proper shipping names: “Lithium hypochlorite, dry or Lithium hypochlorite mixtures, dry,” UN1471; “Printing ink, flammable,” UN1210; and “Nitrocellulose membrane filters,” UN3270.

    —For the entry, “Methacrylic acid, stabilized,” UN2531, we are replacing Packing Group III with Packing Group II.

    —We are removing various domestic entries that have “NA” identification number assignments. As discussed in the NPRM, after reviewing the domestic entries, we determined that the HMR includes “UN” identification numbers assigned to entries that are equally appropriate in a number of instances, and in these instances the NA numbers are no longer necessary. In the NPRM, the revision of “Diesel fuel” with the identification number NA1883 was a printing error which we are correcting in this final rule. “Diesel fuel,” NA1993 is retained and we are adding “Diesel fuel, UN1202.” This amendment will allow flexibility of choice in the use of proper shipping names for domestic transportation. In addition, for the convenience of the HMT users, we are separating the entry “Gas oil or Diesel fuel or Heating oil, light” by giving each name a separate line entry in appropriate alphabetical order. In response to comments requesting that we reconsider the proposed removal of “Gasohol,” we are not removing the entry from the HMT.

    One commenter recommended that we provide T codes and IBC codes (see § 172.102, Special Provisions) for the entry “Combustible liquid, n.o.s.,” NA 1993. We agree with the commenter and are adding portable tank instruction T1, portable tank Special Provision TP1 and IBC code IB3. However, we did not assign IB6 to this entry, as requested by the commenter, because § 173.150(f) currently allows for the use of non-specification bulk packagings.

    Included in the proposed removals are seven domestic pesticide proper shipping names identified by the pesticide industry as no longer being used. These entries are: “Aldrin, liquid,” NA2762; “Aldrin, solid,” NA2761; “Dieldrin,” NA2761; “Methyl parathion liquid,” NA3018; “Methyl parathion solid, NA2783; “Parathion,” NA2783 and “Tetraethyl pyrophosphate solid,” NA3018.

    —We are adding radioactive material (Class 7) entries consistent with new entries introduced in the UN Recommendations and IAEA's “Regulations for the Safe Transport of Radioactive Material, No. TS-R-1.” In addition, we are revising the current radioactive material entries in the HMR to indicate that these entries may be used for domestic shipments, but may be inappropriate for international transportation.

    —For Class 1 (explosive) entries, we are revising Columns (10A) and (10B) to reflect the vessel stowage codes as they are presented in Amendment 30 to the IMDG Code. (See § 172.101(k) and § 176.63.)

    —For the international entry “Methanol,” we proposed adding a plus sign (+) in Column (1) of the HMT to indicate that this entry is classified with a subsidiary hazard of Class 6.1 on the basis of human experience consistent with the UN Recommendations. One commenter objected to this proposal by stating that the action would unnecessarily restrict the shipment of dilute solutions of methanol. The commenter presented diluted methanol meeting the criteria for PG III as an example. In previous preamble discussions (see HM-215C Final Rule—Federal Register: March 5, 1999 (Volume 64, Number 43)) we indicated that a mixture or solution containing a hazardous material where the hazard is significantly different from that of the pure material should be evaluated on the basis of classification criteria. If such a mixture or solution does not meet the corresponding hazard class, a different proper shipping name may be used. Our position remains that when a mixture or solution of a material that is assigned a plus sign in column 1 of the HMT, no longer exhibits a hazard to humans, the material need not be described using a proper shipping name with a plus sign assignment. We recognize the need to clarify the intent of the plus sign in paragraph (b)(1). We are adding a sentence to paragraph (b)(1) to clarify the applicable requirements when the plus (+) sign is assigned to a proper shipping name.

    —We are removing the entry “Isobutyric anhydride,” UN2530.

    —For the entry “Morpholine,” UN2054, we are replacing Class 3 with Class 8, replacing Packing Group III with Packing Group I , and adding Class 3 as the subsidiary hazard.

    —For “Organic peroxide type F, solid, temperature controlled,” (UN3120), we are removing the Packing Group III entry that was due to a printing error in 49 CFR. The PG II entry remains.

    —For approximately 14 Zone A and B toxic-by-inhalation entries, we are revising the quantity limits for transport by air to “forbidden.” These revisions are consistent with other toxic-by-inhalation entries in the HMT and with the requirements of the ICAO Technical Instructions.

    —For the entry “Fire extinguishers containing compressed or liquefied gas” we are adding Special Provision 110 to Column (7).

    —We received a comment stating that our proposal to add Special Provisions 128 and B115 to the entry, “Magnesium granules, coated, particle size not less than 149 microns,” UN2950 (PG III only) was not reflected in the HMT and should also apply to “Water-reactive solid, n.o.s,” UN2813. After re-evaluation, we do not consider that it is appropriate to apply Special Provision 128 to “Magnesium granules, coated,” UN2950, because we are not convinced that these materials pose a Class 8 risk. As explained in the NPRM, this action is based on a petition for rulemaking (P-1338) that we received from the Aluminum Company of America (Alcoa). Special Provision 128 allows material meeting the Class 8 definition to be classed as a Division 4.3 with a Class 8 subsidiary hazard. Special Provision B115 authorizes the use of certain non-specification sift-proof bulk packagings when the material is loaded dry, precautions are taken to prevent liquid from reaching the hazardous materials and the bulk packagings are appropriately vented. However, UN2950 is assigned to bulk packaging § 173.240 which already allows non-specification bulk packagings and, therefore, we are not applying Special Provision 128 or B115 to UN2950 in this final rule. In response to the comment that Special Provisions 128 and B115 should apply to “Water-reactive solid, n.o.s.” UN2813, we note that exemption DOT E-11602 only applies to one specific material containing magnesium or magnesium nitrides that is described using a technical name in association with “Water reactive solid, n.o.s.” We do not agree that broad application of Special Provisions 128 and B115 to all Start Printed Page 33322PG II or III water-reactive solids is appropriate or necessary.

    —We received a comment stating that we did not include IBC and portable tank assignments for the PG II entry for “Extracts, flavoring, liquid,” UN1197. The oversight is corrected in this final rule.

    —Several commenters noted minor editorial errors in the HMT and we made the changes as appropriate.

    —For approximately 1,600 entries, we are revising Column (7) by harmonizing the HMR authorizations for IBCs with those contained in the UN Recommendations. As dicussed in the NPRM, in most cases the UN Recommendations provide for greater flexibility in the use of different types of IBCs. However, for certain hazardous materials, the incorporation of the UN IBC requirements further restricts the types of IBCs that were authorized prior to this final rule for certain hazardous materials. For example, some Packing Group II liquid hazardous materials of Class 3, Division 6.1 and Class 8 that were previously authorized to be transported in composite IBCs with flexible inner receptacles (such as 31HZ2) are no longer authorized. For the benefit of the reader and to facilitate a review of the proposed amendments, in the NPRM, we included a table identifying all of the affected hazardous materials and indicated the current bulk assignments and the proposed IBC assignments.

    The IBC packaging requirements are included in a newly-created IBC Table under the Special Provisions section in § 172.102(c)(4). The table consists of IBC Codes (using the designations IB1-IB99) corresponding to the UN IBC packing instructions, and BB Codes corresponding to the UN IBC special packing provisions. We assigned the IBC packing instructions and the BB codes to specific hazardous materials in Column (7) of the § 172.101 HMT consistent with assignments in the UN Recommendations. In addition, we believe that consolidating the IBC requirements into one table makes it easier for readers to identify the authorized IBCs for specific hazardous materials. As a result of this amendment, we are revising the bulk special provisions in § 172.102(c)(3) to remove the previously authorized bulk codes relevant to the use of IBCs. We are also revising the current IBC packaging authorizations under §§ 173.240(d), 173.241(d), 173.242(d) and 173.243(d).

    This revision also addresses a petition we received from the Rigid Intermediate Bulk Container Association (RIBCA) (P-1395) requesting that we amend the HMR to expand the use of IBCs consistent with new UN provisions. Specifically, the petitioner requested that we allow the use of rigid plastic IBCs and composite IBCs with a rigid plastic inner receptacle for certain liquids. We agree with RIBCA's request, however, as discussed in the NPRM, in the interest of harmonization, we believe it is more beneficial to adopt the UN Recommendations' IBC packing instructions in totality, and, as such, are amending the HMR accordingly.

    One commenter stated that under the new IBC packing instructions, sodium cyanide and potassium cyanide would no longer be permitted in fiberboard or flexible IBCs. The commenter states that they are currently shipped this way according to B69. Although the UN Recommendations do not allow these types of IBCs for such materials, we are maintaining authorization for the use of fiberboard IBCs in domestic transportation. We will pursue the amendment to IB7 to allow the use of fiberboard (11G) IBCs through a proposal to the UN Transport Committee. However, we do not agree that flexible IBCs should be authorized for these hazardous materials.

    The commenter also stated that large packagings should be authorized for sodium cyanide and potassium cyanide. Assignment of large packaging authorizations to specific substances is beyond the scope of this final rule. Currently, the UN Recommendations do not authorize large packagings for these substances. Large packagings are limited primarily to Packing Group III hazardous materials in the UN Recommendations. We plan to work through the UN Transport Subcommittee to address the commenter's concerns and depending on the outcome, we will address this issue in a future rulemaking.

    Appendix B to § 172.101. In Appendix B to 172.101, List of Marine Pollutants, we are revising paragraph “1” by referencing § 171.4, which contains the applicability and exceptions for offering for transportation or transporting marine pollutants. We are revising paragraph “2” to reflect the IMDG Code's provision for the use of two Class 9 proper shipping names when a marine pollutant is not listed by name in the HMT and does not meet the definitions of Class 1 through 8. In addition, a number of materials are added, removed or amended in the List of Marine Pollutants. The entry “EPTC (ISO)” is removed. The entry was also the subject of a petition for rulemaking (P-1360) requesting removal of the entry based on its removal from the IMDG Code. Various other entries no longer identified as marine pollutants are also removed. Consistent with the proper shipping name revisions to replace the word “inhibited” with “stabilized,” we are making the change to five entries in the List of Marine Pollutants. All of the amendments to the List of Marine Pollutants are consistent with the marine pollutants provided in Amendment 30 of the IMDG Code. (Also see § 172.101, HMT for comment on use of proper shipping names for certain marine pollutants.)

    One commenter stated that the proposal to remove the entry “Dichlorobenzenes (meta, ortho and para)” from Appendix B and replace it with the entry “Dichlorobenzene (para)” will result in an inappropriate listing of entries in Appendix B of the HMT for dichlorobenzene isomers. The commenter stated that the changes in Amendment 30 of the IMDG Code only delist “1,2 Dichlorobenzene (ortho)” as a marine pollutant and that the appropriate dichlorobenzene entry, in addition to existing “1,3 Dichlorobenzene,” and “1,4 Dichlorobenzene,” should be “Dichlorobenzene (meta; para).” We agree with the commenter and are revising the entry accordingly.

    Section 172.102. We are revising, adding and removing special provisions as follows:

    —Special Provision 43 is revised to include a provision which excepts “Nitrocellulose membrane filters,” UN3270 from the HMR requirements if shown not to meet the criteria for a Division 4.1 hazardous material, according to burn rate tests in Subsection 33.2.1. of the UN Manual of Tests and Criteria, Part III.

    —Special Provision 110 is revised to more fully identify fire extinguishers that may be assigned to certain proper shipping names. The revision also provides for harmonization with the ICAO Technical Instructions. (We also are adding the special provision to the entry, “Fire extinguishers containing compressed or liquefied gas.” See § 172.101 HMT amendments.)

    —Special Provision 128 is revised based on the amendment to assign it to “Magnesium granules, coated, particle size not less than 149 microns.” (See § 172.101 HMT changes.)

    —Special Provision 136 is revised to reflect the changes adopted by the UN Committee of Experts and the ICAO Dangerous Goods Panel for the entry “Dangerous Goods in Machinery or Dangerous Goods in Apparatus.” (Also see § 172.101 HMT changes.) Start Printed Page 33323We are revising the special provision by removing the text specific to the determination of the hazard class based on the UN Committee of Experts' decision that items under this entry should be assigned to Class 9.

    —A new Special Provision 139 is added for two new entries, “Radioactive material, transported under special arrangement, fissile” and “Radioactive material, transported under special arrangement non-fissile or fissile-excepted.” The special provision requires international shipments using the two entries to be made under an IAEA Certificate of Competent Authority to be issued by the U.S. Competent Authority. Domestic shipments transported under the two entries would be allowed only under a DOT exemption.

    —A new Special Provision 142 is assigned for the new entry “Nitroglycerin mixture, desensitized, liquid, n.o.s.” The special provision requires the material to be approved by the Associate Administrator.

    —A new Special Provision 143 is added for the entry “Life-saving appliances, not self-inflating, containing dangerous goods as equipment.” The special provision clarifies which articles may be transported under this entry.

    —A new Special Provision A53 is added for the entry “Refrigerating machines,” UN2857 and contains the exceptions from the HMR for certain refrigerating machines. The exceptions are currently in § 173.307.

    —In conjunction with the amendment to revise and consolidate the IBC requirements (see § 172.101, Column (7) changes), we are adopting the following changes: revising the special provisions for bulk packagings in paragraph (c)(3) to exclude IBCs by revising Special Provisions B53 and B69 and removing Special Provisions B100, B101, B103 through B106 and B108 through B110, adding a new paragraph (c)(4) for special provisions specific to IBCs (IP Codes). IP codes are used to describe the IBC packing instructions. We redesignated the term “BB” Codes, as named in the NPRM, to “IP” Codes in this final rule in order to make it easier for the HMR user to locate the Special Provisions. By redesignating the “BB” Codes, the IB the IP Codes will be listed together in alphabetical order in § 172.102.

    —The current T codes in paragraph (c)(7) are revised to reflect the incorporation of requirements for UN portable tanks and apply to hazardous materials of Classes 2 through 9. The revised T codes are consistent with those in the UN Recommendations and the IMDG Code and supersede the current HMR IM portable tank T codes. The T code provisions are required in addition to the requirements in part 178. The codes specify the types of authorized portable tanks according to the specific hazardous material transported in the portable tank. Portable tank assignments for Zone A and Zone B toxic-by-inhalation liquids remain consistent with their current assignments in the HMR. In instances where the UN requires a competent authority approval for transportation in portable tanks (such as when TP9 is assigned in the UN Recommendations), we have removed the approval provision. A transition period is provided for the continued use of the existing T codes for IM and DOT 51 portable tanks (see § 171.14(d)(5)).

    One commenter stated that we did not provide for filling limits for portable tanks used to transport refrigerated liquefied gases. To correct this oversight, we are including filling limits that are similar to those applicable to cryogenic cargo tanks authorized under the HMR to transport refrigerated liquified gases. The filling limits will be contained in new Special Provision TP5 which was previously reserved. TP5 is assigned to all refrigerated liquified gases with a tank code T75 assignment.

    A commenter stated that fittings were not defined for TP22 which states that lubricants for portable tank fittings must be oxygen compatible. We do not believe that it is necessary to define “fittings” other than to require that they must be oxygen compatible. Our basic intent is that no incompatible materials or lubricants be used on fittings such as fasteners, valves, gauges, pipe thread or other fittings that may come into contact with the oxygen and cause an unsafe condition in transport.

    — We are removing proposed TP47 because it is not currently necessary. It is not assigned to any entries and the present requirements are addressed in the applicable packaging sections.

    — In paragraph (c)(7)(iv), we are adding definitions for “small,” bare,” “sunshield” and “insulated” as they apply to T50.

    —A new Special Provision W7 is added for seven new Class 7 entries and assigned the vessel stowage category “D,” as defined in § 172.101(k)(4), to uranyl nitrate hexahydrate solution.

    — A new Special Provision W8 is added for four new Class 7 entries and assigned the vessel stowage category “D,” as defined in § 172.101(k)(4), to pyrophoric thorium metal or pyrophoric uranium metal.

    — Finally, a new Special Provision W9 is added for assignment to the entries, “Calcium hypochlorite, dry or Calcium hypochlorite mixtures dry with more than 39 percent available chlorine (8.8 percent available oxygen,” UN1748; “Calcium hypochlorite, hydrated or Calcium hypochlorite, hydrated mixtures with not less than 5.5 percent but not more than 10 percent water,” UN2880; and “Calcium hypochlorite mixtures, dry, with more than 10 percent but not more than 39 percent available chlorine.” UN2208. This action aligns the packaging requirements for these entries with those contained in Amendment 30 to the IMDG Code by authorizing certain packagings only when approved by the Associate Administrator.

    Section 172.202. We are revising paragraph (a)(4) based on a comment requesting that we eliminate the shipping paper requirement for inclusion of the packing group (PG II) for Class 1 (explosives) because the requirement conflicts with the UN Recommendations, the ICAO Technical Instructions and the IMDG Code, all of which do not require the inclusion of PG II on shipping papers. We agree with the commenter. The packing group does not indicate the degree of risk for explosives and does not aid emergency responders and we are providing an exception from this requirement. Based on the same reasoning, we are including in paragraph (a)(4) an exception from the packing group notation for organic peroxides and self-reactive materials.

    Section 172.203. We are revising paragraphs(d)(11), (i) and (n). In paragraph (d)(11), we are allowing an exception from the requirement to add the appropriate group notation to the shipping description for a shipment of low specific activity material or surface contaminated objects provided the group notation is contained in the proper shipping name. Based on a commenter's request for clarification, we are making editorial revisions to this paragraph to improve the clarity of the additional description requirements applicable to low specific activity (LSA) materials and surface contaminated objects (SCO). We are changing the wording “unless these symbols are” to “unless the group notation is,” and adding the wording “as described in the § 172.101 Hazardous Materials Table” after the wording “proper shipping name.”Start Printed Page 33324

    In paragraph (i), we are adding two shipping paper description requirements for transportation by vessel. The first amendment is added as new paragraph (i)(5) and requires the flash point for a liquid hazardous material with a flash point of 61 °C or below to be included on shipping papers when transported by water.

    One commenter objected to the proposed requirement that for materials having a flash point of 61 °C or less (closed cup c.c.), the flash point must be included on shipping papers. The commenter questioned the value of this requirement. We submit that knowledge of the flash point of a material is a requirement for vessel operators under the requirements of SOLAS Chapter II-2, Regulation 54. The SOLAS requirement imposes cargo hold, electrical, ventilation, fire protection and bilge pump requirements on hazard classes 3, 6.1 and 8, having a flash point of 61 °C or less. In order to ensure that vessel operators have this information, the IMDG Code requires a shipper to include the flash point of such materials on shipping papers. Although for most hazardous materials this information may be derived from the classification and packing group, for some hazardous materials this is not possible. To ensure that the flash point information is readily available, and to harmonize the HMR with the IMDG Code, we are adopting the requirement as proposed.

    As discussed in the NPRM, we received a petition (P-1402) from the Vessel Operators Hazardous Materials Association (VOHMA) requesting that we add an additional shipping paper description requirement to include the minimum flash point in degrees Celsius for Class 3 (flammable) or combustible liquid hazardous materials. VOHMA stated that the amendment would help support compliance with the current stowage requirements in § 176.305(c) and the segregation requirements (Code 22 and 23, see § 176.84) as designated in Column (10B) of the § 172.101 Hazardous Materials Table. We agree with the petitioner's reasoning, however, for consistency with the IMDG Code, we are adding the requirement to specify the flash point when it is 61 °C or below for all such liquid hazardous materials whether or not the primary hazard is Class 3. The second amendment to the shipping paper description requirements for transportation by vessel is added as new paragraph (i)(6) and is based on comments from the USCG regarding further harmonization with the IMDG Code. The amendment requires subsidiary risks of a hazardous material that are not reflected in the proper shipping name to be included on shipping papers.

    In paragraph (n), we are clarfiying that the shipping paper requirement for the word “HOT” to be placed immediately preceding the proper shipping names of hazardous materials that are transported as elevated temperature materials, is not required for proper shipping names containing the words “Molten” or “Elevated temperature.”

    Section 172.330. Consistent with the proper shipping name revisions that replace the word “inhibited” with “stabilized” (see § 172.101), we are revising three such proper shipping names in paragraph (a)(1)(ii).

    Sections 172.402, 172.405 and 172.411. We received several comments concerning the proposal to remove the requirement to differentiate between primary and subsidiary labels. One commenter opposed the requirement with no elaboration. A second commenter stated that it would lower the level of safety. A third commenter opposed the adoption of the requirement stating that as an emergency responder, vital information necessary to respond to an incident would be lost. We disagree with this commenter. When a hazardous material has two or more hazards, each hazard must be considered in determining the appropriate response to an incident. The commenter also pointed out that the subsidiary risk is not required on shipping papers which would be another method for emergency responders to obtain the information. Under a separate rulemaking and consistent with the 12th edition of the UN Recommendations, we plan to propose a requirement to identify the subsidiary risks on shipping papers for all modes. In addition, for vessel only, we are adopting a requirement in this final rule for mandatory notation of subsidiary hazards on shipping papers, unless the subsidiary hazard is reflected in the proper shipping name. Consistent with the eleventh revised edition of the UN Recommendations, we are removing the requirement to differentiate between primary and subsidiary labels. Prior to this final rule, primary labels were required to display the hazard class or division number in the lower corner of the label, while subsidiary labels could not display these numbers. We believe the display of the hazard class and division on all labels will enhance safety and hazard communication. We are amending the requirement which provides for two label specifications (one for primary hazards and one for subsidiary hazards) by removing the subsidiary hazard label specification. This change also provides relief by eliminating the need for shippers to stock two sets of labels.

    Another commenter stated that the proposed 5 year transition period for continued use of subsidiary risk label requirements in effect prior to this final rule, is too lengthy and could cause problems in domestic transportation for multimodal shipments. The commenter stated that the proposed transition period is not necessary because the ICAO Technical Instructions and the IMDG Code have much shorter transition periods in place, and that it seems unlikely that shippers would stock 5 year supplies of subsidiary risk labels. Based on feedback from industry, we believe that a 5 year transition period is warranted to allow sufficient time for filled packagings that are pre-labeled to complete their cycle out of transportation. We are not convinced that the 5 year transition period will cause problems in domestic transportation. Also, based on feedback from industry, we maintain that many shippers stock 5 year supplies of subsidiary risk labels. Therefore, in order to provide a reasonable transition period, we are allowing labels meeting the label specifications in place prior to this final rule to continue to be displayed until October 1, 2005, at which time labels used to convey both primary and subsidiary hazards must display the appropriate hazard class or division number at the bottom of the label. (See § 171.14 for transition provisions.) The same amendment also applies to placards (see § 172.519).

    Section 172.502. In paragraph (b), we are correcting an error that was published in the February 1, 2001 final rule under Docket HM-215D. Based on a request from the Federal Register, we added a reference to “see § 171.7.” During the typesetting process, the ICAO Technical Instructions were mistakenly added and the TDG Regulations were mistakenly omitted. We are correcting this error by removing the ICAO Technical Instructions and reinstating the TDG Regulations.

    Section 172.504. Based on comments and our own initiative, we are revising paragraph (g) by allowing the display of only one placard bearing one compatibility letter when certain Class 1 materials (explosives) of different compatibility groups are transported together in a single transport vehicle or container. This amendment is consistent with the mixed packaging provisions in § 173.61.

    Section 172.519. Consistent with the amendment to eliminate the distinction between primary and subsidiary labels, we are revising paragraph (b)(4) to eliminate the requirement to distinguish Start Printed Page 33325between primary and subsidiary placards. In addition, we are incorporating a new paragraph (b)(4)(i) to permit subsidiary placards meeting the current placarding specifications (such as placards without the hazard class or division number displayed in the lower corner of the placard) to continue to be displayed in domestic transportation provided they were permanently affixed before October 1, 2001. Non-permanently affixed subsidiary placards meeting the current placarding specifications are allowed to be displayed until October 1, 2005. (See § 171.14 for transition provisions.)

    Part 173

    Section 173.2a. Consistent with the eleventh revised edition of the UN Recommendations, in the paragraph (b) Precedence of Hazard Table, we are revising Footnote 2 to exclude liquid and solid desensitized explosives. In addition, we are adding the revised Footnote 2 to Class 3, PG I, II and III in the paragraph (b) Precedence of Hazard Table.

    Section 173.4. Based on a request for clarification, we are revising paragraph (a) to clarify that the small quantity exceptions apply to packagings containing articles, as well as inner receptacles.

    Section 173.24b. We are adding a new paragraph (e) to address acceptance of foreign manufactured UN portable tanks that conform to the applicable provisions in the UN Recommendations on the Transport of Dangerous Goods and are manufactured in countries that provide reciprocal treatment for UN portable tanks manufactured in the United States.

    Section 173.29. One commenter requested that two petitions for rulemaking be addressed in this final rule. The petitions request that IBCs meeting the Environmental Protection Agency's empty container rule in 40 CFR 261.7 be allowed to be transported without vehicle placarding and shipping papers. We are not addressing this issue under HM-215D because it is beyond the scope of this rulemaking.

    Section 173.31. Consistent with the proper shipping name revisions that replace the word “inhibited” with “stabilized” (see § 172.101), we are revising one such proper shipping name in § 173.31(b)(2)(ii).

    Section 173.32. One commenter stated that the consolidation of §§ 173.32, 173.32b and 173.32c would impose requirements for DOT Specification 57 portable tanks that previously did not apply. The commenter provided specific recommendations for ensuring that new requirements for the maintenance and continued use of DOT Specification 57 portable tanks are not introduced. We did not intend to impose new requirements for DOT Specification 57 portable tanks. We considered the recommendations of the commenter and revised § 173.32(d), (f) and (h) to address these recommendations.

    One commenter suggested that we incorporate certain editorial changes in § 173.32 and part 180, subpart G, to clarify that not all portable tanks have a maximum allowable working pressure (MAWP) and that some requirements do not apply to all portable tanks, such as DOT Specification 56 and 57 portable tanks. The commenter stated that DOT Specification 57 portable tanks, for example, have a design pressure, but not a MAWP. The commenter also noted that when we consolidated the repair, inspection, test and maintenance requirements for portable tanks in the NPRM, we applied requirements to DOT Specification portable tanks that currently are not applicable under the HMR. We agree with the commenter's suggestions and are incorporating the suggested editorial corrections.

    One commenter stated that one of its members maintains and operates a large fleet of ICC Specification portable tanks and they requested that we maintain the current grandfather provisions for these portable tanks. As stated in the NPRM, our intent with removing the provisions was based on whether these portable tanks were being used. With receipt of this comment, we are retaining the provisions currently in 173.32(b) and (c) of the HMR by incorporating them into § 173.32(c)(4) and (c)(5) in this final rule.

    The commenter also stated that DOT Specification 60 and marine portable tanks were not addressed in the NPRM and requested that these portable tanks be authorized for continued use. We did not propose any changes in the NPRM that would prevent continued use of these portable tanks.

    Another commenter expressed concern regarding our proposal to allow UN portable tanks to be designed and constructed to pressure vessel design codes other than the ASME Code. The commenter asked which codes would be acceptable and expressed concern that we would allow codes that are “less stringent” than the ASME Code. In response to this comment, we wish to advise the commenter that codes other than ASME will only be authorized if approved by the Associate Administrator for Hazardous Materials Safety, and only for UN portable tanks intended for the transport of liquid and solid hazardous materials. No approval provision was proposed for use of alternative design codes for portable tanks intended for the transport of liquefied gases. Because alternative codes are only allowed if approved by the Associate Administrator, applications for use of other design codes will be reviewed on a case by case basis. It is not our intention to allow the use of design codes that will not provide an equivalent level of safety as afforded in the ASME Code. We did not include a list of potential alternative codes because we have not considered which codes we will accept and because other factors, in addition to the design code, will be considered in each case.

    One commenter stated that it is unclear whether the grandfather provision for DOT Specification 56 and 57 portable tanks manufactured after October 1, 1996 provides for such portable tanks to continue in service. We note that DOT Specification 56 and 57 portable tanks were not authorized to be manufactured after October 1, 1996. On October 1, 1996, the UN IBC requirements were introduced which replaced DOT Specification 56 and 57 portable tanks.

    Because paragraphs (c)(3) and (g) concerning pressure relief valves for DOT specification portable tanks are duplicative, we are removing paragraph (g). With this action the paragraphs following the removed paragraph (g) are renumbered.

    As proposed in the NPRM, we are revising § 173.32 to provide requirements for all portable tanks by consolidating the requirements for the use of IM portable tanks currently in § 173.32c into a single section and moving them to part 180, subpart G, with the qualification and maintenance requirements for IBCs, cargo tanks and tank cars. We are also including a grandfather clause in § 173.32 to allow IM 101, 102 and DOT 51 portable tanks to continue to be constructed in accordance with the HMR until January 1, 2003. IM 101, 102 and DOT 51 portable tanks which are certified and approved prior to this date are authorized for continued use provided they meet the applicable periodic inspection and test requirements in part 180, subpart G. These requirements were previously in § 173.32b. On January 1, 2003, all newly manufactured portable tanks will be required to conform to the requirements for the design, construction and approval of UN portable tanks (see §§ 178.274, 178.275, 178.276 and 178.277). Finally, we are removing the provisions for the continued use of DOT Specification 52 and 53 portable tanks based on our view that these portable tanks are no longer Start Printed Page 33326in use and the lack of comments to the contrary.

    Section 173.32a. We are removing § 173.32a and moving its approval requirements for specification portable tanks to § 178.273. We believe that part 178 is a more appropriate location for these requirements and that the new section will prove to be more convenient for users of the HMR. We also are including similar requirements for the incorporation of requirements for UN portable tanks.

    Section 173.32b. We are removing § 173.32b and relocating the test requirements to part 180, subpart G, as discussed in § 173.32.

    Section 173.32c. We are removing § 173.32c. The requirements for the use of all specification portable tanks are now included in § 173.32, thereby precluding the need for § 173.32c.

    Section 173.34. Consistent with the proper shipping name revisions that replace the word “inhibited” with “stabilized” (see § 172.101), we are revising two such proper shipping names in § 173.34(e)(13).

    Section 173.61. Based on our own initiative, for Class 1 (explosives) mixed packaging requirements, we are revising paragraph (e)(3) to allow explosives of compatibility group S that are allowed to be packaged with explosives of all other compatibility groups, except A and L, to be treated as belonging to any of the packaged compatibility groups except S. In addition, we are adding a new paragraph (e)(8) to allow explosive articles in compatibility group G, except for fireworks and articles requiring special packaging, to be packaged with articles of compatibility groups C, D and E, and the combined package may be treated as belonging to compatibility group E. This revision corresponds with the previous allowance contained in § 177.848(g).

    Section 173.62. Consistent with adding the entries “Rockets with inert head,” UN0502 and “1H-Tetrazole,” UN0504 to the § 172.101 Table, we are adding them to the paragraph (b) Explosives Table which specifies the Packing Instructions assigned to each explosive. In paragraph (c), we are revising the Explosives Packing Instructions Table to authorize additional types of outer packagings in the following packing instructions: 112(a), 112(b), 112(c), 113, 115, 116, 130, 131, 134, 135, 136, 138, 140, 141,142 and 144.

    Section 173.150. We are revising paragraph (d) by clarifying that alcoholic beverages containing over 24% alcohol by volume are not excepted from regulation when transported by a passenger or crewmember on passenger-carrying aircraft except as provided in § 175.10(a)(17). (See preamble discussion under § 175.10.)

    Section 173.162. We are revising paragraph (a)(1) by clarifying that the types of packagings specified in the paragraph are combination packagings and that the glass, earthenware or rigid plastic packagings are authorized as inner packagings only. In addition, for these packagings, we are increasing the net mass of 10 kg (22 pounds) for each packaging to15 kg (33 pounds). This is consistent with Packing Instruction 800 in the UN Recommendations.

    Section 173.185. We are revising § 173.185 to include a definition for equivalent lithium content for lithium ion cells and batteries and to provide the applicable aggregate lithium quantities relevant to excepting lithium ion cells and batteries from the requirements of the HMR consistent with the eleventh edition of the UN Recommendations. The definition of lithium content was revised in this final rule to make it consistent with a minor editorial clarification adopted by the Committee of Experts in its report of the 21st session (see section 38.3.2.2 in the amendments to the UN Manual of Tests and Criteria, report number ST/SG/AC.10/27/Add.2). This clarification was included based on a comment that we received. We adopted this clarification in order to prevent possible confusion about the lithium-equivalent content of lithium-ion battery packs that are currently used in many portable devices. For the readers' information, we plan to issue an NPRM under a separate rulemaking initiative to address the 12th edition amendments to the UN Recommendations that require all lithium batteries, regardless of the lithium content, to be subject to the lithium battery tests in Section 38 of the UN Manual of Tests and Criteria. The lithium battery amendments and revised test methods are available in the report of the UN Committee of Experts and may be downloaded at http://www.unece.org/​trans/​main/​dgdb/​dgcomm/​ac10rep.html.

    Several commenters stated that we did not include the revised requirements applicable to large lithium batteries used for electric and hybrid vehicles and requested that we make the correction in the final rule. Although we discussed the amendment in the NPRM's preamble, the revised requirements were inadvertently omitted from the regulatory text. This error is corrected in this final rule.

    Section 173.224. Consistent with the UN Recommendations, we are adding the entry “2,2'-Azodi(isobutyronitrile) as a water-based paste” to the Self-Reactive Substances Table for substances that are not subject to the approval provisions of § 173.124(a)(2)(iii), provided all applicable provisions in the table are met. Finally, we are revising paragraph (b)(4) and removing paragraph (d) to allow Type F self-reactive substances to be transported in portable tanks under conditions specified in § 173.225(e) (see preamble discussion under § 173.225).

    Section 173.225. We are amending the paragraph (b) Organic Peroxide Table by making various changes, such as revising several technical names, packing method authorizations and control temperatures. These changes are consistent with the UN Recommendations. We are removing Notes “7” and “10” consistent with the adoption of UN IBC 520 and adding Note “26” to specify the available oxygen content limitation for certain new organic peroxide formulations. We are revising paragraph (e) to incorporate the requirements from the eleventh revised edition of the UN Recommendations relevant to the emergency venting devices for portable tanks and IBCs used for the transportation of organic peroxides and self-reactive substances. This responds to NTSB recommendation (I-92-2) that asked us to “revise the requirements for pressure relief venting on DOT Specification 57 portable tanks used to transport dicumyl peroxides and other products with similar rapid decomposition characteristics to ensure that the pressure relief systems prevent overpressure rupture of tanks from a rapid product decomposition reaction.” We are applying the recommended venting requirements to all portable tanks and IBCs, rather than just DOT Specification portable tanks. Additionally, the types of portable tanks authorized for type F organic peroxide and self-reactive substances are expanded to include UN portable tanks. We are adopting the requirements in Portable Tank Instruction T23 and IBC Special Provision, IBC 520.

    A commenter brought to our attention that Note 26 as proposed would conflict with the § 173.21 restriction for ketone peroxides which limits oxygen content to 9% or less. We agree and are removing the proposed Note 26 text and renumbering the proposed Note 27 to Note 26. In addition, based on a comment, we are adding an organic peroxide formulation for 2,5 Dimethyl 2,5 di-2-ethylhex anoylperoxy hexane, UN3113. The entry was adopted in the UN Recommendations and inadvertently omitted in the NPRM.Start Printed Page 33327

    We understand that the current Organic Peroxide Table includes a number of formulations that are no longer used. We encourage users of the Organic Peroxide Table to provide us with comments in this regard, as well as suggestions for improving the Organic Peroxide Table.

    Sections 173.240, 173.241, 173.242 and 173.243. In each section's paragraph (c), we are removing Specification DOT 52 and 53 portable tanks as authorized packagings (see § 173.32 ) because we believe that these portable tanks are no longer used. In addition, we are authorizing UN portable tanks. In conjunction with the revision to the requirements for IBCs, for alignment with international standards, we are revising paragraph (d) which specifies authorized IBCs in §§ 173.240, 173.241, 173.242 and 173.243 to reflect the proposed incorporation of IBC packing instructions and IP codes (see § 172.101, Column (7)). Based on a comment that we received, we are not requiring temperature sensing devices or reclosing pressure relief devices for DOT Specification 57 portable tanks. We agree with the commenter that such portable tanks have limited use and are very similar to IBCs.

    We also received a comment stating that § 173.240 should be amended to allow the use of non-specification flexible (“supersacks”) IBCs for hazardous materials such as “Environmentally hazardous substances, solid, n.o.s.” Specifically, the commenter requested that we authorize the use of non-specification “supersacks” in § 173.240. The commenter questioned the omission by asking why we do not authorize non-specification IBCs, yet we provide for the use of other non-specification bulk packagings. While it is our intent at this time to maintain authorization for use of non-specification portable tanks and bulk bins in § 173.240(c), we do not agree that non-specification IBCs should be authorized. The only non-specification bulk packagings authorized in § 173.240 are portable tanks and bulk bins which are rigid packagings of a higher integrity when compared to a 2,000 pound non-specification bag. Neither the current HMR nor the UN Recommendations authorize the use of non-specification IBCs for environmentally hazardous substances. We believe that authorization of the non-specification “supersacks” would be detrimental to safety and, therefore, we are not incorporating it into the HMR.

    Section 173.247. In paragraph (c), we are removing Specification DOT 52 and 53 portable tanks as authorized packagings (see § 173.32).

    Sections 173.301, 173.304, 173.314, 173.315 and 172.330. Consistent with the proper shipping name revisions that replace the word “inhibited” with “stabilized” (see § 172.101), we are revising all such proper shipping names in these sections.

    Section 173.306. Consistent with Packing Instruction P201 in the UN Recommendations, we are amending the paragraph (a)(4)(iii) conditions for transporting flammable, non-pressurized gas samples by revising the inner packagings limit from 2.5 L (0.66 gallons) to 5 L (1.3 gallons).

    Sections 173.314 and 173.315. Consistent with the proper shipping name revisions that replace the word “inhibited” with “stabilized” (see § 172.101), we are revising one such proper shipping name in § 173.314(c) and (g) and two such proper shipping names in § 173.315(a), (b) and (h).

    Section 173.315. As proposed in the NPRM, we are revising paragraphs (a) and (i)(1)(iii) to incorporate provisions for the use of UN portable tanks for the transportation of liquefied compressed gases and the requirements for DOT Specification 51 portable tanks. In paragraph (a), we are incorporating a reference to new tank instruction T50 (see UN T Codes under § 172.102) for the transportation of liquefied compressed gases in UN portable tanks. In paragraph (i)(1)(iii), we are including the pressure relief device requirements applicable to UN portable tanks.

    We received a comment questioning the intent in paragraph (a)(1)(iii) concerning the insulation requirements. The commenter was concerned that the paragraph prevents the use of mylar, other low melting films and aluminum for jacket materials. We note that the paragraph does not prohibit the use of jackets constructed of materials other than steel, except in the case when the portable tank manufacturer is attempting to lower the required relieving capacity of the relief devices by taking into account the thermal protection afforded by the insulation. The UN portable tank requirements intentionally restrict the jacketing material to steel when using the insulation as a means for reducing the required relieving capacity of the pressure relief devices, because jacket materials with lower melting temperatures, such as aluminum, would not provide adequate fire damage protection for the inner vessel, or for the vacuum insulation in the case of a vacuum insulated tank to justify allowing a lower overall relieving capacity for the pressure relief system. We agree with the UN reasoning for limiting jacket material to steel, and, therefore, we are adopting the paragraph as proposed.

    Section 173.320. For transportation by air for cryogenic liquids exceptions, we are making an editorial clarification in paragraph (c) to refer readers to the specific cites in the ICAO Technical Instructions rather than stating “see § 171.11 of this subchapter.”

    Part 175

    Section 175.10. For consistency with the ICAO Technical Instructions, we are revising paragraph (a)(10) to clarify that lighters containing “unabsorbed liquid fuel” are prohibited on one's person or in checked or carry-on baggage. We are revising exclusions for alcoholic beverages as carry-on and checked baggage to impose a per passenger quantity limit and to restrict the exceptions to alcoholic beverages in retail packagings containing not more than 70% alcohol. We are revising paragraph (a)(16) to exclude alcoholic beverages. Also, we are adding new paragraph (a)(17) to specify that alcoholic beverages containing more than 24% and not more than 70% alcohol by volume, when carried by passengers or crew in checked or carry-on baggage, are not subject to the HMR if in retail packagings not exceeding 5 liters (1.3 gallons) with a total net quantity per person of 5 liters (1.3 gallons). These changes are consistent with the ICAO Technical Instructions.

    Section 175.33. For harmonization with the ICAO Technical Instructions, we are revising paragraph (a) introductory text to add a requirement that the written pilot notification must be accurate and legible.

    Section 175.78. We are revising this section to update and align segregation requirements with recent changes adopted in the ICAO Technical Instructions which were based on a UN decision to remove the distinction between primary and subsidiary risk labels. Separate rows and columns are provided for Divisions 5.1 and 5.2. We are adding a new provision to clarify that packages with multiple risks do not need to be segregated from other packages bearing the same UN number. The ICAO Technical Instructions currently require segregation of Divisions 5.1 and 4.3 hazardous materials and we have revised the entry to reflect the change.

    Section 175.85. Consistent with a new provision adopted in the ICAO Technical Instructions, we are revising paragraph (a) to authorize use of main deck Class C cargo compartments for the transport of hazardous materials. Prior Start Printed Page 33328to this final rule, hazardous materials were allowed to be carried in a main deck cargo compartment of a passenger aircraft provided the compartment was inaccessible to passengers and it met certification requirements for a Class B cargo compartment. (Class C cargo compartments differ from Class B cargo compartments in that Class C compartments are required to have a built-in fire extinguishing system, in addition to smoke or fire detection systems.)

    Part 176

    Section 176.2. In conjunction with incorporating a requirement for vessel cargo to be in compliance with the INF Code (see § 176.720), we are adding a definition for “INF cargo” under the § 176.2 definitions.

    Section 176.63. For the stowage of Class 1 (explosive) materials on board a vessel, we are adding a stowage location definition for “closed cargo transport unit.” This addition coincides with the addition of the vessel stowage category definitions contained in Amendment 30 to the IMDG Code. (See § 172.101(k).)

    Section 176.84. Consistent with the IMDG Code we are revising paragraph (b) Table of provisions and paragraph (c)(2) stowage provisions. In the paragraph (b) Table of provisions, we are adding two new stowage provisions for assignment to the entries: “Calcium hypochlorite, dry or Calcium hypochlorite mixtures dry with more than 39 percent available chlorine (8.8 percent available oxygen),” “Calcium hypochlorite, hydrated or Calcium hypochlorite, hydrated mixtures, with not less than 5.5 percent but not more than 10 percent water,” and “Calcium hypochlorite mixtures, dry with more than 10 percent but not more than 39 percent available chlorine.” In the paragraph (c)(2), we are revising the list of notes for the stowage of Class 1 (explosive) material provisions.

    Section 176.128. We are making an editorial change in § 176.128(c) by correcting an identification number.

    Section 176.136. We are making an editorial change in § 176.136 by removing the word “portable.”

    Section 176.142. Based on a comment from the National Cargo Bureau, Inc., in § 176.142, paragraph (a), we are revising the list of hazardous materials that may not be transported in a vessel carrying Class 1 (explosive) materials to reflect the most current proper shipping names and add one extremely flammable material, “Methyl phosphonous dichloride, pyrophoric liquid,” NA2845.

    Section 176.720. We are adding a new section to require a vessel carrying INF cargo in international transportation to comply with the “International Code for the Safe Carriage of Packaged Irradiated Nuclear Fuel, Plutonium and High-Level Radioactive Wastes on Board Ships,” (INF Code, 2000, English edition). The INF Code was adopted by the International Maritime Safety Committee and became effective January 1, 2001 in the IMDG Code.

    Part 177

    Section 177.848. In paragraph (g)(3)(vi), we inadvertently added the terms “special stowage” and “stowed” from the corresponding vessel section of the HMR (§ 174.81) under HM-215C (64 FR 10742). We are correcting the wording by removing “special stowage,” which is not applicable to this section, and replacing “stowed” with “loaded, transported and stored.” We received a joint petition from the American Trucking Associations (ATA) and the Institute of Makers of Explosives (IME) (P-1396) requesting additional clarification of this paragraph. Prior to this rule, the paragraph read:

    “(vi) “6” means explosive articles in compatibility group G, other than fireworks and those requiring special stowage, may be stowed with other explosive articles of compatibility groups C, D and E, provided no explosive substances (for example, those not contained in articles) are carried in the same vehicle.”

    In this paragraph and the corresponding paragraph in § 174.81, the petitioners request that the words “other explosives” be inserted before the wording “explosive substances.” The petitioners are incorrect in their interpretation of the wording of this paragraph. Explosive articles in compatibility group G may be stowed with certain other explosive articles (C, D and E compatibility groups), provided no explosive substances that are not contined within articles are carried in the same vehicle. We point out that there is a distinction between the words “articles” and “substances.” To take advantage of this paragraph, explosive substances that are not contained in articles may not be carried on the vehicle. We are revising the paragraph to clarify that substances are prohibited when not contained in articles.

    Part 178

    Section 178.273. We are adding a new section by moving the current requirements for the approval of portable tanks from § 173.32a to § 178.273. This new section will include approval provisions for all portable tanks, including “UN portable tanks.” These current approval provisions will precede the requirements for UN portable tanks (§§ 178.274 through 178.277). Approval agencies that have an interest in approving UN portable tanks must send a request to DHM-32, Office of Hazardous Materials Approvals, in accordance with the requirements in part 107, subpart E of this subchapter.

    Sections 178.274, 178.275, 178.276 and 178.277. Based on the eleventh revised edition of the UN Recommendations, we are incorporating four new sections into the HMR for the UN portable tank requirements. This action is based on our own initiative and a petition for rulemaking (P-1373) and is consistent with our international harmonization objectives. The requirements apply to the design and construction of portable tanks. The IMO Dangerous Goods, Solid Cargoes and Containers (DSC) Sub-Committee incorporated the new harmonized UN multimodal portable tank requirements into the reformatted IMDG Code, Amendment 30. The reformatted IMDG Code became effective on January 1, 2001. The IMDG Code also includes a provision to allow for the continued use of portable tanks designed and constructed under the current requirements (those in Amendment 29 or previous amendments to the IMDG Code as applicable, depending on the date of construction).

    The IMO allows construction under the new requirements on January 1, 2001, on a voluntary compliance basis, with a mandatory compliance date of January 1, 2003. On January 1, 2003, all new portable tanks will be required to be manufactured in accordance with the new requirements. For purposes of harmonization, we are incorporating the corresponding design, construction and use requirements for UN portable tanks in the HMR. In addition, in § 173.32 we are providing for the continued use of IM 101, 102 and DOT Specification 51 portable tanks, which is consistent with the provisions adopted in the IMDG Code.

    The design and construction requirements for UN portable tanks do not differ significantly from the previous IM 101 and 102 portable tanks and the DOT Specification 51 requirements. In general, the UN requirements are less restrictive. For example, 6 mm (0.2 inches) minimum thickness is required for most portable tanks, as opposed to the current minimum thickness of 6.35 mm (0.3 inches) for IM 101 and 102 portable tanks. As discussed in the NPRM, while the majority of the changes involve relaxations of the regulatory requirements, there will be implications for portable tank manufacturers, Start Printed Page 33329shippers and operators who transport hazardous materials in portable tanks. For example, we are requiring UN portable tanks used for the transportation of liquefied compressed gases to be approved by a DOT-designated approval agency, and we are requiring all UN portable tanks to meet a 4 g impact test. In addition to portable tanks for liquids and liquefied compressed gases, we are incorporating requirements for portable tanks that are used to transport refrigerated liquified gases (cryogenic liquids). Previous to this final rule, requirements for portable tanks used for refrigerated liquefied gases were not specified in the HMR, and we authorized their use only under DOT exemptions. The differences between UN portable tanks and the previous portable tank requirements include, but are not limited to the following:

    —The new definition for portable tank includes multimodal tanks with a capacity of more than 450 liters (118.9 gallons).

    —The new design temperature range is defined as -40 °C to 50 °C (-40 °F to 122.0 °F). This final rule includes the requirement that design temperatures must be considered for portable tanks subjected to severe climatic conditions. Previous to this final rule, regulations specified a range of -20 °C to 50 °C (-4.0 °F to 122.0 °F).

    —The new UN leakage test for portable tanks intended for the transport of liquids specifies a test pressure not less than 25% of Maximum Allowable Working Pressure (MAWP). The previous HMR requirements specified an internal pressure equivalent to MAWP, but not less than 0.2 bar (20.0 kPa) for liquids.

    —The new test requires that the design and construction of portable tanks must take into account the effects of fatigue during normal conditions of transport. Previously, this was not required in the HMR.

    —The new requirements specify an absolute minimum thickness of 3 mm (0.1 inches), regardless of the material used and regardless of whether additional protection is provided.

    —Under the new requirements, a rail impact test of 4 g is required for all portable tanks meeting the definition of “Container” in the International Convention for Safe Containers (CSC).

    —The new requirements specify that the test pressure be 1.3 times the design pressure for portable tanks intended for the transport of liquefied gases. Previously, under the HMR, DOT 51 portable tanks used for the transportation of liquefied gases were required to have a test pressure of 1.5 times the design pressure; however, this is based on the vapor pressure of the hazardous material at 115 °F (46.1 °C), whereas the UN calculates the vapor pressure at 65 °C (149 °F). The differences between 1.5 at 46 °C and 1.3 at 65 °C, therefore, would not be significant. (Although one commenter stated that they disagreed with this statement, our view is explained further in the preamble discussion under § 178.274.)

    —The new requirements include a figure for thermal conductance for the thermal insulation systems of shells intended for the transport of liquefied compressed gases.

    —The new requirements include a definition for “Holding time” relevant to portable tanks used for the transportation of refrigerated liquefied gases. This is consistent with current HMR requirements in § 178.338-9 for cargo tanks.

    —The new requirements specify the effectiveness of the insulation system (heat influx in watts) based on a test using the portable tank.

    —The new requirements allow the specified minimum values of material strength for austenitic steels to be increased by 15% according to recognized material standards when greater values are provided in the material inspection certificates.

    —The new requirements allow the combined capacity of all pressure relief devices to be sufficient to limit the pressure to 120% of the MAWP for liquefied compressed gases.

    Section 178.274. One commenter stated that the required test pressure for UN portable tanks used for the transportation of propane would increase from 320 psig to 400 psig. We believe that the values cited by the commenter are not accurate. Based on the Fourth Edition of the Compressed Gas Association Handbook of Compressed Gases, the vapor pressure of propane is approximately 220-230 psia at a reference temperature of 115 °F (46.1 °C) and approximately 270-275 psia at 130 °F (54.4 °C). The required MAWP according to § 173.315 is 250 psi. The test pressure for a UN portable tank would be approximately the same as that for a DOT 51 portable tank and in some cases may be slightly less. In this case, it would not be in the interest of harmonization to vary from the internationally agreed design pressure formulas. Based on the above, we are adopting the requirement as proposed.

    One commenter stated that aluminum should be authorized as a material for portable tank shell construction. The UN Recommendations allows aluminum only for portable tanks intended for liquid and solid materials when approved by the competent authority. Aluminum is not authorized for portable tank shells intended for non-refrigerated liquefied gases, however, aluminum is authorized for shells of portable tanks intended for the transportation of refrigerated liquefied gases. Based on the merits of these comments and to be consistent with the UN Recommendations, we are amending paragraph (b) accordingly.

    Also regarding paragraph (b), some commenters requested background information explaining the justification and application of the proposed -40 °C lower range for the design temperature applicable to UN portable tanks. This lower temperature was adopted because the UN working group recognized that -20 °C was not sufficient to represent temperatures that UN portable tanks may experience in certain parts of the world. One commenter stated that it was not clear whether the requirement was applicable to all portable tank components or only to the shell. In response to this comment, we point out that the design temperature range applies to the shell which is the primary pressure and lading retention component of the portable tank. The general requirements for design and construction state that “Portable tank materials must be suitable for the external environment where they will be transported taking into account the determined design temperature range.” This provision requires service equipment to be suitable for the climatic conditions to which it will be exposed. For these reasons, we are not amending the proposed language.

    One commenter stated that the change from the very prescriptive relief device location for IM portable tanks in § 178.270-11(b)(1)(i) to the less specific requirement is “too open to interpretation” and requested clarification. We do not agree with the commenter. The main safety concern is that when the tank is filled to its maximum filling condition, the relief device is located in the vapor space and will ensure that escaping vapor can be discharged free from any obstruction. The text accomplishes this objective and is more flexible and performance-oriented. Specifically limiting the location by specifying exact tolerances forces us to issue exemptions and approvals when the location varies from these specific parameters. In addition, the text as proposed in this section is consistent with how the HMR specifies pressure relief device location for DOT specification 400 series cargo tanks Start Printed Page 33330(see178.345-10(c)). We are adopting the text as proposed.

    One commenter stated that the proposed requirement to group outlet openings in paragraph § 178.274(e)(7) of the NPRM should not apply to portable tanks used for refrigerated liquified gases due to their unique design. The commenter explained that this requirement does not currently apply to exemption cryogenic portable tanks or MC 338 Specification cargo tanks (see § 178.338-7), nor is it a requirement under the UN Recommendations. We agree with this commenter and are amending the paragraph to reflect that the external fitting grouping requirement applies only to portable tanks intended for the transportation of non-refrigerated liquefied gases. This amendment is consistent with the current requirement that applies to DOT Specification 51 portable tanks in § 178.245-1(c). We agree that the additional exceptions applicable to locating openings in other locations in § 178.245-1(d)(1), (2) and (3) should also apply and, therefore, we are revising the text accordingly. Because these requirements are applicable only to portable tanks intended for the transport of non-refrigerated liquified gases, we are moving the text to the more appropriate location of § 178.276.

    We received two comments concerning the proposed requirements for the internal valve emergency shut-off device in paragraph (e)(7). One commenter stated that there is no requirement in the UN Recommendations nor the IMDG Code for a thermally activated closure. Our intent with this paragraph is consistency with a requirement that was published under a final rule (Docket HM-166Y; 63 FR 37453) on July 10, 1998, requiring an IM portable tank to be retrofitted if unloaded while it remained on a transport vehicle with the power unit attached. The commenter stated that we proposed to expand the concept by making a thermally activated device part of the service equipment for all UN portable tanks and that the requirement would be contrary to harmonization because UN portable tanks are used worldwide. They suggested that the requirement should first be introduced at the UN Committee of Experts for consideration. Although the requirement is only a condition for unloading IM portable tanks from vehicles while the motor unit is attached, we were informed through meetings with portable tank users and manufacturers that it is not feasible to determine which IM portable tanks would be offloaded in this manner and that all IM portable tanks would need to be retrofitted with thermally activated closure devices (fusible links) in order to comply with the requirement in § 177.834(o). In a request for an interim final rule concerning the retrofitting requirement published in HM-166Y final rule, the Hazardous Materials Advisory Council (HMAC) stated “For commercial and economic reasons, it is not practical to remove all tanks from service at once to retrofit the bottom outlet valves with thermally activated closure devices. Tanks are either in a transport cycle, in storage, or in repair/maintenance shops. If all of the portable tanks were taken out of service at the same time to complete this retrofit, many industrial operations would be severely disrupted.” DOT 51 portable tanks are required to be fitted with these closures (see § 178.245-1(d)(iii)) and in the HM-215D NPRM we proposed that UN portable tanks used for non-refrigerated liquified gases be fitted with these devices consistent with paragraph 6.7.3.5.4 of the UN Recommendations. The UN Recommendations require “quick closing” shut-off devices that close automatically in the event of fire engulfment and unintended movement of the portable tank for portable tanks used to transport flammable refrigerated and flammable and toxic non-refrigerated liquified gases. We are removing the requirements for these shut-off devices to operate based on unintended movement because we believe it is not practical. We believe that even though this is not a requirement under the UN Recommendations for liquid materials, it is a domestic requirement and from the safety perspective, as discussed under Docket HM-166Y, it should be applied to U.S. manufactured UN portable tanks intended for the transportation of liquid hazardous materials which are flammable, pyrophoric, oxidizing or toxic. We believe it would be in the best interest of safety to fit these portable tanks with thermally activated closures. We estimate that the cost of installing a fusible link will be approximately $40.00 to $70.00 per portable tank based on information provided by tank and tank valve and component manufacturers. Installation at the time of manufacture will avoid downstream retrofitting costs, costs associated with shipping delays and logistical problems at a later date. In previous discussions with the Hazardous Materials Advisory Council and the Tank Container Association, we were informed that retrofitting of portable tanks would cost approximately $200.00 to $250.00 per portable tank. On the basis of these costs, it makes economic sense to install the devices at the time of manufacture. We agree that this requirement should be proposed to the UN Committee of Experts and will follow-up accordingly. On the basis of enhanced safety, minimal cost at the time of manufacture, shipping delays and logistics, we are requiring U.S. manufactured UN portable tanks intended for transporting certain liquids to be fitted with thermally activated closures (fusible links). The internal valve shut-off requirements are revised for consistency in §§ 178.275(d)(3), 178.276(c)(4) and 178.277(d).

    Concerning paragraph (i), one commenter stated that markings such as maximum allowable working pressure, test pressure, maximum gross mass and the applicable T Code should be marked on the tanks following the “UN” mark in order to convey that the cargo is authorized for that particular portable tank. We agree that a T marking on the tank may be advantageous, however, the UN Recommendations do not require a T mark and imposing such a requirement is beyond the scope of this final rule. Incorporation of a T code marking in this rule could lead to different requirements in domestic and international regulations if such a proposal is not adopted by the UN Transport Subcommittee. With regard to the other markings, the information is marked on a specification plate (see § 178.274(i) of the regulatory text). Finally, we moved the requirements for the initial inspection and test of portable tanks from § 180.605(d), as presented in the NPRM, to the more appropriate location § 178.274(j).

    Sections 178.274 and 178.275. One commenter stated that although the term “fusible elements” is used in the UN Recommendations, the purpose of the devices and whether they are mandatory service equipment is unclear. The commenter stated that in the final rule it would be helpful to clarify the definition and use of these devices. We agree with the commenter and are adding a definition for “fusible elements” in § 178.274(a)(3) and are clarifying the use of “fusible elements” in § 178.275(f)(4).

    A commenter requested that we allow UN portable tanks used for the transportation of refrigerated liquefied gases to be tested using an inert gas as an alternative to hydrostatic testing with water. The commenter explained that this is a common industry practice and is necessary because the saddle designs for these portable tanks are not designed to hold the associated weight of the water necessary to conduct the Start Printed Page 33331hydrostatic test. The commenter further explained that the alternative method is necessary because it is difficult to entirely remove all of the water in the inner tank after the hydrostatic test is completed. In addition, the UN Recommendations authorize the pressure test using an inert gas. We accept this comment and are amending § 178.274(j)(2) to include a provision to allow, as an alternative to hydrostatic testing with water, testing with an inert gas for portable tanks used for the transportation of refrigerated liquefied gases.

    Section 178.275. Regarding paragraph (c), a commenter stated that damage to the liner in a portable tank would be inevitable when welding a blind (blank) flange on the inside and outside of the portable tank shell. The commenter suggested a tamper proof flange as an alternative to the welded flange as proposed in the NPRM. The UN portable tank working group considered a number of alternate configurations or possibilities for closing bottom openings in portable tanks when they are retrofitted to remove bottom opening configurations. The working group was opposed to use of a bolted flange because of the possibility that it may leak during transportation. While inclusion of an alternative to welding is beyond the scope of this rule, a means of authorizing non-welded bottom flange configurations may be considered under the alternative arrangement approval provisions.

    Another commenter stated that the presence of a liner in a portable tank should not be justification for authorizing the portable tank to be used without an internal shut-off valve. The commenter stated that internal shut-off valves can be fitted on lined portable tanks and that the proposed exception would result in a decrease in safety. We agree and based on the merits of the comment, we believe that a lined tank should have a internal shut-off and are removing the proposed exception in paragraph (c)(4) which states, “For a lined shell, the internal stop valve required by paragraph (c)(3)(i) of this section may be replaced by an additional external stop valve.”

    One commenter stated that the external design pressure should not be based on the internal pressure because, as proposed, the requirement would impose unrealistic external design pressure requirements. We agree with this commenter and are revising the wording in paragraph (e) to remove the reference to the internal pressure. On this basis, a shell that is to be equipped with a vacuum-relief device must be designed to withstand, without permanent deformation, an external pressure of not less than 0.21 bar.

    Section 178.276. See discussion under § 178.274 for discussion concerning the relocation of certain text.

    We received a comment stating that § 178.276 should be revised to provide an exception from the internal stop valve requirement for portable tanks used for the transportation of chlorine. The commenter requested alternative wording to clarify whether a threaded cap or pipe plug can be used as the third means of closure on portable tank openings. We agree and are revising the text in § 178.276(c)(1) to state “* * * and the third being a blank flange, threaded cap, plug or equivalent liquid tight closure device.” We are also revising § 178.276(c)(3) to indicate that this paragraph only applies to openings below the liquid level of the portable tank. This wording will eliminate the need for portable tanks used to transport chlorine from having to be fitted with internal stop valves because these portable tanks have loading and unloading fittings only at the top of the tank. We are also including a new paragraph (7) to address inlets and discharge outlets, internal excess flow valves on portable tanks used to transport chlorine.

    Section 178.277. One commenter stated that the NPRM preamble included a new filling limit for helium, yet it was not contained in the regulatory text in § 178.277. We recognized the oversight and added a new tank provision, TP5 to address the filling limit. (See § 172.102, Special Provisions.)

    Another commenter stated that it is not necessary to specify impact test requirements in paragraph § 178.277(b)(4) and that the proposed provision for conducting impact tests at 0 °F on materials to be used for refrigerated liquefied gases are not suitable because such portable tanks operate at much lower temperatures. The commenter went on to say that the ASME Code adequately addresses this issue. We agree with the commenter and have removed the proposed provision.

    Another commenter stated that we overlooked the fact that the UN Recommendations do not require portable tanks used for the transportation of refrigerated liquefied gases to have an opening for inspection. The commenter stated that the internal inspection requirements for these portable tanks should be removed because: (1) The portable tanks are not currently fitted with inspection openings, (2) internal corrosion is not a factor for portable tanks used to transport refrigerated liquefied gases, (3) the UN Recommendations do not require internal inspection for these portable tanks, and (4) fitting of inspection openings on these portable tanks does not enhance safety. We agree with the commenter and are including the exceptions for refrigerated liquefied gas portable tanks in paragraphs (d)(7) and § 180.605(e) and (f).

    We are including the above discussed amendments and, as proposed in the NPRM, we are adding five new sections (§§ 178.273 through 178.277) to the HMR as follows: § 178.273 is added by moving the current requirements for the approval of Specification portable tanks from § 173.32a and introducing similar requirements for UN portable tanks; § 178.274 is added for the UN portable tank general design and construction requirements; § 178.275 is added for the additional specifications for UN portable tanks intended for the transportation of liquid and solid materials of Classes 3 through 9; § 178.276 is added for the additional requirements for UN portable tanks intended for the transportation of liquefied compressed gases; and § 178.277 is added for the additional requirements for the design, construction, inspection and testing of UN portable tanks intended for the transport of refrigerated liquefied gases.

    Section 178.703. Consistent with § 178.3(a)(4), paragraph (a)(1) is revised by including a minimum height of 12 mm (0.5 inches) for IBC markings and by adding a requirement to allow use of the “W” mark for approval of equivalent IBC packagings, as provided for in § 178.801(i). Two commenters stated that while they support a minimum marking size of 12 mm for IBCs, it is not clear how this would apply to IBCs manufactured prior to the effective date of this final rule. In response to these commenters, we revised paragraph (a)(1) to clarify that the minimum marking size only applies to IBCs manufactured after the effective date of this final rule (October 1, 2001).

    Section 178.705. We are revising the minimum wall thickness requirements to take into account the capacity in the case of metal IBCs.

    Section 178.801. In paragraph (i), we are adding an approval provision for the use of large packagings, as defined in § 171.8 of this NPRM, provided the large packagings conform to the construction standards, performance testing and packaging marking as specified in UN Recommendations.

    Section 178.812. Based on our initiative, we are revising paragraph (c)(1) and adding a new paragraph (c)(3) to include an alternate method for conducting the top lift test for flexible Start Printed Page 33332IBCs. Prior to this final rule, the alternate method was authorized in several approvals issued by the Associate Administrator.

    Part 179

    Section 179.102-4. Consistent with the proper shipping name revisions that replace the word “inhibited” with “stabilized” (see § 172.101), we are revising one such proper shipping name in this section.

    Part 180

    Sections 180.601, 180.603, 180.605. We are moving the qualification and maintenance requirements for portable tanks from § 173.32(c) to part 180. As discussed in the NPRM, we believe that these requirements are more appropriately placed in part 180 along with the qualification and maintenance requirements for cargo tanks, IBCs and tank cars. Therefore, as proposed, we are adding new subpart G to part 180 for the qualification and maintenance of portable tanks. (Also see § 173.32.) One commenter suggested that we incorporate certain editorial changes to § 173.32 and part 180, subpart G, to clarify that not all portable tanks have a maximum allowable working pressure (MAWP) and that some requirements do not apply to all portable tanks, such as DOT Specification 56 and 57 portable tanks. We agree and have made the clarification revisions accordingly.

    Section 180.603. A commenter requested that grandfather provisions be included in § 180.603 to recognize that portable tanks constructed and used in accordance with existing DOT exemptions are authorized for continued use provided they meet the applicable periodic inspection and test requirements. We do not agree with this request because such exemptions remain valid and their continued use are not affected by this final rule.

    Section 180.605. Several commenters stated that the periodic inspection requirements for portable tanks proposed in the NPRM are not entirely consistent with those specified in the UN Recommendations. They quoted the UN Recommendations as stating: “A portable tank filled prior to the date of expiry of the last periodic inspection and test may be transported for a period not to exceed three months beyond the date of expiry of the last periodic test or inspection.” In addition, a portable tank may be transported after the date of expiry of the last periodic test and inspection after emptying but before cleaning, for purposes of performing the next required test or inspection prior to refilling and unless otherwise approved by the competent authority, for a period not to exceed six months beyond the date of expiry of the last periodic test or inspection, in order to allow the return of dangerous goods for proper disposal or recycling. Reference to this exemption shall be mentioned in the transport document. The commenters requested that we adopt this text from the UN Recommendations in the final rule. We do not agree that the UN Recommendations' text should be included in the HMR. We believe that the UN text imposes arbitrary limits on the length of time that a portable tank may be transported after expiration of the inspection and test date. The HMR text allows a portable tank to continue to be transported after the expiration of the test date while prohibiting filling of a tank once the periodic inspection and test dates have expired. We wish to clarify that the text as proposed was based on existing text for cargo tanks (see 173.33(a)(3)) and for portable tanks (see 173.32(e)(5)). The text in place prior to this final rule, as well as the text adopted in this final rule, allows portable tanks which contain a residue, or are being transported to a cleaning, testing or repair facility, to be transported after the inspection and test date expires. In the NPRM, we simply consolidated this requirement in a more appropriate section and applied it universally to all portable tanks. We are adopting the text as proposed, even though it is less restrictive than the UN Recommendations text, because it is practical and does not impose unnecessary burdens on the regulated public or government. On this basis, we are not adopting the suggestions of the commenters. We also wish to note that the text in § 180.605(b)(3), as proposed and adopted, requires a portable tank that has been out of service for more than one year to be periodically retested.

    Several commenters stated that they support our efforts to adopt the UN portable tank requirements. The commenters support the requirement that DOT 51 Specification portable tanks not be allowed to be manufactured after January 1, 2003, however, they do not support the conditions for continued use of existing DOT 51 portable tanks as proposed in the NPRM. We did not introduce new requirements for periodically retesting DOT Specification 51 portable tanks in the NPRM nor was it our intention to do so. The retest provisions for DOT Specification 51 portable tanks are specified in § 180.605(c)(2) and requires that the portable tanks be retested at least once every 5 years.

    For paragraphs (e) and (f), see § 178.277(d)(7) discussion regarding an exception from the requirement for portable tanks used for the transportation of refrigerated liquefied gases to have an opening for inspection. We moved the initial inspection and test requirements from § 180.605(d), as proposed in the NPRM, to § 178.274(j) which we believe is a more appropriate location. For a comment on an alternative to hydrostatic testing with water, see § 178.274(j).

    We also received a comment stating that we should have included an exception from the requirement for UN portable tanks intended for the transportation of “Helium refrigerated liquid (cryogenic liquid),” UN1963 and “Hydrogen, refrigerated liquid (cryogenic liquid),” UN1966 to be subjected to the 4 G rail impact test as prescribed in § 180.605(d)(6). The commenter reasoned that high thermal performance liquid hydrogen and helium containers are not transported on railroads due to the large impact loads experienced during coupling and that such UN portable tanks are marked with the words “NOT FOR RAIL TRANSPORTATION.” We agree with the commenter. When the requirements for UN portable tanks were developed, the UN working group agreed that portable tanks used for the transportation of refrigerated liquefied helium and hydrogen should be excepted from rail impact testing. A special provision was added allowing the transportation of these refrigerated liquefied gases under conditions specified by the competent authority. In this final rule, we are excepting portable tanks intended for the transport of refrigerated liquefied helium and hydrogen from the requirements of a rail impact test. Instead of requiring an approval provision, we are adding a sentence to § 180.605(d)(6) to except portable tanks from the 4 G impact test when the portable tanks are used in dedicated service for the transportation of “Helium, refrigerated liquid,” UN1963 and “Hydrogen, refrigerated liquid,” UN1966 and are marked “NOT FOR RAIL TRANSPORT” in letters of a minimum height of 20 cm (8 inches) on at least two sides of the portable tank.

    Another commenter stated that the proposed marking size amendment in § 180.605(l) requires inspection and test markings that are not included on the specification plate of a portable tank to be 32 mm (1.25 inches) high, yet as the commenter points out, currently § 173.32(e)(3) allows markings for DOT Specifications 51, 56, 57 and 60 portable tanks to be a minimum height of 12 mm. We agree with the commenter and after considering the proposed amendment, we do not believe that a marking height Start Printed Page 33333of 32 mm is necessary for these particular portable tanks. Therefore, we are adopting a minimum test and inspection marking height of 3 mm when the markings are on the specification plate, and a marking height of 12 mm when the markings are directly on the portable tank.

    IV. Rulemaking Analyses and Notices

    A. Executive Order 12866 and DOT Regulatory Policies and Procedures

    This final rule is not considered a significant regulatory action under section 3(f) of Executive Order 12866 and, therefore, was not reviewed by the Office of Management and Budget. This final rule is not considered a significant rule under the Regulatory Policies and Procedures of the Department of Transportation (44 FR 11034). Benefits resulting from this final rule include enhanced transportation safety resulting from the consistency of domestic and international hazard communications and continued access to foreign markets by domestic shippers of hazardous materials. Many companies involved in domestic, as well as global operations, will realize economic benefits as a result of the amendments in this rulemaking. The total net increase in costs to businesses in implementing this rulemaking is minimal and we have determined that the intended benefits of harmonizing the HMR with international standards outweigh the minimal increase in costs to industry. For interested parties, a regulatory analysis is available for review in the public docket.

    B. Executive Order 13132

    This final rule has been analyzed in accordance with the principles and criteria contained in Executive Order 13132 (“Federalism”). This final rule preempts State, local and Indian tribe requirements but does not adopt any regulation that has substantial direct effects on the States, the relationship between the national government and the States, or the distribution of power and responsibilities among the various levels of government. Therefore, the consultation and funding requirements of Executive Order 13132 do not apply.

    The Federal hazardous material transportation law, 49 U.S.C. 5101-5127, contains an express preemption provision (49 U.S.C. 5125(b)) that preempts State, local, and Indian tribe requirements on certain covered subjects. Covered subjects are:

    (1) The designation, description, and classification of hazardous materials;

    (2) The packing, repacking, handling, labeling, marking, and placarding of hazardous materials;

    (3) The preparation, execution, and use of shipping documents related to hazardous materials and requirements related to the number, contents, and placement of those documents;

    (4) The written notification, recording, and reporting of the unintentional release in transportation of hazardous; or

    (5) The design, manufacture, fabrication, marking, maintenance, recondition, repair, or testing of a packaging or container represented, marked, certified, or sold as qualified for use in transporting hazardous material.

    This final rule addresses covered subject items (1), (2), (3), and (5) above and would preempt State, local, and Indian tribe requirements not meeting the “substantively the same” standard. This final rule is necessary to incorporate changes already adopted in international standards. If the changes in this final rule are not adopted in the HMR, U.S. companies, including numerous small entities competing in foreign markets, would be at an economic disadvantage. These companies would be forced to comply with a dual system of regulation. The changes in this final rule are intended to avoid this result. Federal hazardous materials transportation law provides at section 5125(b)(2) that, if DOT issues a regulation concerning any of the covered subjects, DOT must determine and publish in the Federal Register the effective date of Federal preemption. The effective date may not be earlier than the 90th day following the date of issuance of the final rule and not later than two years after the date of issuance. Thus, RSPA lacks discretion in this area. The effective date of Federal preemption will be December 18, 2001.

    C. Executive Order 13084

    This final rule has been analyzed in accordance with the principles and criteria contained in Executive Order 13084 (“Consultation and Coordination with Indian Tribal Governments”). Because this final rule does not significantly or uniquely affect the communities of the Indian tribal governments and does not impose substantial direct compliance costs, the funding and consultation requirements of Executive Order 13084 do not apply.

    D. Regulatory Flexibility Act

    The Regulatory Flexibility Act (5 U.S.C. 601 et seq.) requires an agency to review regulations to assess their impact on small entities, unless the agency determines that a rule is not expected to have a significant impact on a substantial number of small entities. This final rule will serve to facilitate the transportation of hazardous materials in international commerce by providing consistency with international standards. This final rule applies to offerors and carriers of hazardous materials, some of whom are small entities, such as, chemical manufacturers, chemical users and suppliers, packaging manufacturers, distributors, battery manufacturers, radiopharmaceutical companies and training companies. Based on our assessment in the regulatory analysis, which is available in the public docket, I hereby certify that this final rule will not have a significant economic impact on a substantial number of small entities.

    The majority of amendments in this final rule should result in cost savings and ease the regulatory compliance burden for shippers engaged in domestic and international commerce, including trans-border shipments within North America. For example, cost savings will be realized by shippers and carriers as a result of eliminating the differences between primary and subsidiary labels. As a result of this change, it will no longer be necessary to stock two sets of labels for each hazard class. To ease any burden associated with this change, we are incorporating a reasonable transition period where labels meeting requirements in effect immediately prior to this final rule and the requirements adopted in this final rule may be used.

    Other cost savings include providing greater flexibility for the use of IBCs and portable tanks; retaining current IM 101, 102 and DOT Specification 51 portable tank requirements and providing authorizations for their use; deleting numerous entries from the marine pollutant list for consistency with the IMDG Code; authorizing greater flexibility for transporting samples of hazardous materials; authorizing the use of a single explosives placard when explosives of several compatibility groups are transported in a single freight container or vehicle; and revising requirements for large lithium batteries which will simplify the regulatory requirements applicable to batteries used in high energy efficient hybrid vehicles. Finally, we are authorizing immediate voluntary compliance, delayed effective dates and a one-year transition period to allow for training of employees and to ease any burden on entities affected by the amendments.Start Printed Page 33334

    E. Paperwork Reduction Act

    We have current information collection approvals under OMB No. 2137-0018, Inspection and Testing of Portable Tanks and Intermediate Bulk Containers, which expires March 31, 2002, with 51,340 burden hours and $10,235,000 annual costs, and OMB No. 2137-0557, Approvals for Hazardous Materials, which expires March 31, 2002, with 18,302 burden hours and $413,737.40 annual costs. We believe that this final rule may result in minor incremental increases in the annual burden hours and costs. The current approvals has been revised and resubmitted to OMB for extension and reapproval.

    OMB No. 2137-0018 contains the information collection and recordkeeping requirements in current §§ 173.32, 173.32a, 173.32b, 178.245 and 178.801 for tests, inspections and related records related to the manufacture, qualification, repair or modification of portable tanks or intermediate bulk containers. This information is used to verify that portable tanks and intermediate bulk containers meet the required manufacturing standards prior to being authorized for initial use, and that once manufactured, the packagings are maintenance in conformance with the applicable HMR requirements. OMB No. 2137-0018 is revised to include UN portable tanks and to revise section references to the portable tank requalification requirements which are being relocated to subpart G in Part 180.

    OMB No. 2137-0557 contains the information collection and recordkeeping requirements for packagings and hazardous materials approvals. This information is used to verify that portable tank designs meet the applicable standards. OMB No. 2137-0557 is revised to include UN portable tanks and to revise the section references to the portable tank design approval requirements which are being relocated to Part 178.

    We estimate that the adjusted total information collection and recordkeeping burdens are as follows:

    OMB No. 2137-0018:

    Affected Public: Manufacturers, requalifiers, repairers and modifiers, and owners of certain DOT specification and exemption portable tanks and intermediate bulk containers.

    Number of Respondents: 8,770.

    Total Annual Responses: 86,100.

    Total Annual Burden Hours: 66,390.

    Total Annual Burden Cost: $ 7,137,500.

    One-time Annual Start Up Burden Hours: 350.

    OMB No. 2137-0557:

    Number of Respondents: 3,518.

    Total Annual Responses: 3,869.

    Total Annual Burden Hours: 18,381.

    Total Annual Burden Cost: $ 413,737.40.

    Requests for a copy of the information collection approvals, requests and data should be directed to Deborah Boothe, Office of Hazardous Materials Standards (DHM-10), Research and Special Programs Administration, Room 8102, 400 Seventh Street, SW, Washington, DC 20590-0001, Telephone (202) 366-8553.

    F. Regulation Identifier Number (RIN)

    A regulation identifier number (RIN) is assigned to each regulatory action listed in the Unified Agenda of Federal Regulations. The Regulatory Information Service Center publishes the Unified Agenda in April and October of each year. The RIN number contained in the heading of this document can be used to cross-reference this action with the Unified Agenda.

    G. Unfunded Mandates Reform Act

    This final rule does not impose unfunded mandates under the Unfunded Mandates Reform Act of 1995. It does not result in costs of $100 million or more to either State, local or tribal governments, in the aggregate, or to the private sector, and is the least burdensome alternative that achieves the objective of the rule.

    H. Environmental Assessment

    The National Environmental Policy Act of 1969 (NEPA) requires Federal agencies to consider the consequences of major federal actions and prepare a detailed statement on actions significantly affecting the quality of the human environment. We developed an assessment to determine the effects of these revisions on the environment and whether a more comprehensive environmental impact statement may be required. Our findings conclude that there are no significant environmental impacts associated with this final rule. Consistency in regulations for the transportation of hazardous materials aids in the shipper's understanding of what is required and permits shippers to more easily comply with safety regulations and avoid the potential for environmental damage or contamination. For interested parties, an environmental assessment is available in the public docket.

    Start List of Subjects

    List of Subjects

    49 CFR Part 171

    • Exports
    • Hazardous materials transportation
    • Hazardous waste
    • Imports
    • Incorporation by reference
    • Reporting and recordkeeping requirements

    49 CFR Part 172

    • Education
    • Hazardous materials transportation
    • Hazardous waste
    • Labeling
    • Markings
    • Packaging and containers
    • Reporting and recordkeeping requirements

    49 CFR Part 173

    • Hazardous materials transportation
    • Packaging and containers
    • Radioactive materials
    • Reporting and recordkeeping requirements
    • Uranium

    49 CFR Part 175

    • Air carriers
    • Hazardous materials transportation
    • Radioactive materials
    • Reporting and recordkeeping requirements

    49 CFR Part 176

    • Hazardous materials transportation
    • Maritime carriers
    • Radioactive materials
    • Reporting and recordkeeping requirements

    49 CFR Part 177

    • Hazardous materials transportation
    • Motor carriers
    • Radioactive materials
    • Reporting and recordkeeping requirements

    49 CFR Part 178

    • Hazardous materials transportation
    • Motor vehicle safety
    • Packaging and containers
    • Reporting and recordkeeping requirements

    49 CFR Part 179

    • Hazardous materials transportation
    • Railroad safety
    • Reporting and recordkeeping requirements

    49 CFR Part 180

    • Hazardous materials transportation
    • Motor carriers
    • Motor vehicle safety
    • Packaging and containers
    • Railroad safety
    • Reporting and recordkeeping requirements
    End List of Subjects Start Amendment Part

    In consideration of the foregoing, 49 CFR Chapter I is amended as follows:

    End Amendment Part Start Part

    PART 171—GENERAL INFORMATION, REGULATIONS, AND DEFINITIONS

    End Part Start Amendment Part

    1. The authority citation for part 171 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 49 U.S.C. 5101-5127; 49 CFR 1.53.

    End Authority Start Amendment Part

    2. In § 171.7, in paragraph (a)(1), the fourth sentence is revised and in the paragraph (a)(3) table:

    End Amendment Part Start Amendment Part

    a. Under the entry “American Society for Testing and Materials”, a new entry is added in alpha-numeric order; Start Printed Page 33335

    End Amendment Part Start Amendment Part

    b. Under the entry “International Atomic Energy Agency (IAEA)”, a new entry is added in alpha-numeric order;

    End Amendment Part Start Amendment Part

    c. Under the entry “International Civil Aviation Organization (ICAO)”, the existing entry is revised;

    End Amendment Part Start Amendment Part

    d. Under the entry “International Maritime Organization (IMO)”, for the entry “International Maritime Dangerous Goods (IMDG) Code, 2000 edition”, in the second column, add “; 176.720” after “176.30”; and

    End Amendment Part Start Amendment Part

    e. Under the entry “International Organization for Standardization”, three new entries are added in alpha-numeric order.

    End Amendment Part

    The revisions and additions read as follows:

    Reference material.

    (a) Matter incorporated by reference— (1) * * * The material listed in paragraph (a)(3) has been approved for incorporation by reference by the Director of the Federal Register in accordance with 5 U.S.C 552(a) and 1 CFR part 51. * * *

    * * * * *

    (3) Table of material incorporated by reference. * * *

    Source and name of material49 CFR reference
    *         *         *         *         *         *         *
    American Society for Testing and Materials
    *         *         *         *         *         *         *
    ASTM E 112-96 Standard Test Methods for Determining Average Grain Size, 1996 Edition178.274
    *         *         *         *         *         *         *
    International Atomic Energy Agency (IAEA)
    *         *         *         *         *         *         *
    IAEA, Regulations for the Safe Transport of Radioactive Material, No. TS-R-1, 1996 Edition171.12
    *         *         *         *         *         *         *
    International Civil Aviation Organization (ICAO)
    *         *         *         *         *         *         *
    Technical Instructions for the Safe Transport of Dangerous Goods by Air (ICAO Technical Instructions), DOC 9284-AN/905, 2001-2002 Edition171.11; 172.202; 172.401; 172.512; 172.602
    *         *         *         *         *         *         *
    International Organization for Standardization
    *         *         *         *         *         *         *
    ISO 1496-3 Series 1 freight containers—Specification and testing, Part 3: Tank containers for liquids, gases and pressurized dry bulk, March 1, 1995, Fourth Edition178.274
    *         *         *         *         *         *         *
    ISO 4126-1 Safety valves—Part 1:
    General Requirements, December 15, 1991, First Edition178.274
    *         *         *         *         *         *         *
    ISO 6892 Metallic materials—Tensile testing, July 15, 1984, First Edition178.274
    *         *         *         *         *         *         *
    * * * * *
    Start Amendment Part

    3. In § 171.8, the following definitions are added in appropriate alphabetical order to read as follows:

    End Amendment Part
    Definitions and abbreviations.
    * * * * *

    Large packaging means a packaging that—

    (1) Consists of an outer packaging which contains articles or inner packagings;

    (2) Is designated for mechanical handling;

    (3) Exceeds 400 kg net mass or 450 liters (118.9 gallons) capacity;

    (4) Has a volume of not more than 3 m3 (see § 178.801(i) of this subchapter); and

    (5) Conforms to the requirements for the construction, testing and marking of large packagings as specified in the UN Recommendations.

    * * * * *

    Stabilized means that the hazardous material is in a condition that precludes uncontrolled reaction. This may be achieved by methods such as adding an inhibiting chemical, degassing the hazardous material to remove dissolved oxygen and inerting the air space in the package, or maintaining the hazardous material under temperature control.

    * * * * *

    UN portable tank means a intermodal tank having a capacity of more than 450 liters (118.9 gallons). It includes a shell fitted with service equipment and structural equipment, including stabilizing members external to the shell and skids, mountings or accessories to facilitate mechanical handling. A UN portable tank must be capable of being filled and discharged without the removal of its structural equipment and must be capable of being lifted when full. Cargo tanks, rail tank car tanks, non-metallic tanks, non-specification tanks, bulk bins, and IBCs and packagings made to cylinder specifications are not UN portable tanks.

    * * * * *
    Start Amendment Part

    4. In § 171.10, in paragraph (c)(2), the Table of Conversion Factors for SI Units, a unit of measure is added as the last entry, and in the abbreviation notes following the Table, in the (SI) Start Printed Page 33336abbreviations, a new abbreviation “; Newton, N” is added after “mSv” to read as follows:

    End Amendment Part
    Units of measure.
    * * * * *

    (c) * * *

    (2) * * *

    Table of Conversion Factors for SI Units

    MeasurementSI to U.S. standardU.S. standard to SI
    *         *         *         *         *         *         *
    Force1 Newton = 0.2248 Pound-force1 Pound-force=4.483 N
    * * * * *
    Start Amendment Part

    5. In § 171.11, the introductory text is revised, the comma at the end of paragraphs (d)(6)(i) and (d)(6)(ii) are removed and a period is added in its place, ”, and” at the end of paragraph (d)(6)(iv) is removed and a period is added in their place, and new paragraphs (d)(6)(vi) and (d)(17) are added to read as follows:

    End Amendment Part
    Use of ICAO Technical Instructions.

    Notwithstanding the requirements of parts 172 and 173 of this subchapter, a hazardous material may be transported by aircraft, and by motor vehicle either before or after being transported by aircraft, in accordance with the ICAO Technical Instructions (see § 171.7) if the hazardous material;

    * * * * *

    (d) * * *

    (6) * * *

    (vi) The definition for “radioactive material” in § 173.403 of this subchapter applies to radioactive materials transported under the provisions of this section.

    * * * * *

    (17) An organic peroxide that is not identified by technical name in the Organic Peroxide Table in § 173.225(b) of this subchapter must be approved by the Associate Administrator in accordance with the requirements of § 173.128(d) of this subchapter.

    6. In § 171.12, paragraph (b)(5) is revised, new paragraph (b)(20) is added, paragraphs (d) heading and introductory text and (d)(4) are revised, “and” at the end of paragraph (d)(5) is removed, the period at the end of paragraph (d)(6) is removed and “; and” is added in its place, and paragraph (d)(7) is added to read as follows:

    Import and export shipments.
    * * * * *

    (b) * * *

    (5) Except for IBCs and UN portable tanks intended for liquids or solids, hazardous materials that conform to the requirements of the IMDG Code, bulk packagings must conform to the requirements of this subchapter. For UN portable tanks, Special Provisions TP37, TP38, TP44 and TP45 must be met when applicable. Except as specified in paragraph (b)(8) of this section for a material poisonous (toxic) by inhalation (see § 171.8 of this subchapter), the T Codes specified for specific hazardous materials in Column 13 of the Dangerous Goods List of the IMDG Code may be applied to the transportation of those materials in IM, IMO and DOT Specification 51 portable tanks.

    * * * * *

    (20) An organic peroxide that is not identified by technical name in the Organic Peroxide Table in § 173.225(b) of this subchapter must be approved by the Associate Administrator in accordance with the requirements of § 173.128(d) of this subchapter.

    * * * * *

    (d) Use of International Atomic Energy Agency (IAEA) regulations for Class 7 (radioactive) materials. Class 7 (radioactive) materials being imported into or exported from the United States, or passing through the United States in the course of being shipped between places outside the United States, may be offered and accepted for transportation when packaged, marked, labeled, and otherwise prepared for shipment in accordance with IAEA “Regulations for the Safe Transport of Radioactive Material,” Safety Series No. 6, 1985 edition, or TS-R-1, 1996 edition (see § 171.7) , if—

    * * * * *

    (4) The country of origin for the shipment has adopted the corresponding edition (Safety Series No. 6, 1985 Edition, or TS-R-1, 1996 Edition) of the IAEA “Regulations for the Safe Transport of Radioactive Material';

    * * * * *

    (7) The definition for “radioactive material” in § 173.403 of this subchapter is applied to radioactive materials transported under the provisions of this section.

    7. In § 171.12a, a new paragraph (b)(18) is added to read as follows:

    Canadian shipments and packagings.
    * * * * *

    (b) * * *

    (18) An organic peroxide that is not identified by technical name in the Organic Peroxide Table in § 173.225(b) of this subchapter must be approved by the Associate Administrator in accordance with the requirements of § 173.128(d) of this subchapter.

    Start Amendment Part

    8. In § 171.14, paragraphs (d) introductory text, (d)(1) and (d)(2) introductory text are revised and new paragraphs (d)(4) and (d)(5) are added to read as follows:

    End Amendment Part
    Transitional provisions for implementing certain requirements.
    * * * * *

    (d) A final rule published in the Federal Register on June 21, 2001, effective October 1, 2001, resulted in revisions to this subchapter. During the transition period, until October 1, 2002, as provided in paragraph (d)(1) of this section, a person may elect to comply with either the applicable requirements of this subchapter in effect on September 30, 2001, or the requirements published in the June 21, 2001 final rule.

    (1) Transition dates. The effective date of the June 21, 2001 final rule is October 1, 2001. A delayed compliance date of October 1, 2002 is authorized. On October 1, 2002, all applicable regulatory requirements adopted in the June 21, 2001 final rule in effect on October 1, 2001 must be met.

    (2) Intermixing old and new requirements. Prior to October 1, 2002, it is recommended that the hazard communication requirements be consistent where practicable. Marking, labeling, placarding, and shipping paper descriptions should conform to either the old requirements of this subchapter in effect on September 30, 2001, or the new requirements of this subchapter in the June 21, 2001 final rule without intermixing communication elements. However, intermixing is permitted, during the applicable transition period, Start Printed Page 33337for packaging, hazard communication, and handling provisions, as follows:

    * * * * *

    (4) Until January 1, 2010, a hazardous material may be transported in an IM or IMO portable tank in accordance with the T Codes (Special Provisions) assigned to a hazardous material in Column (7) of the HMT in effect on September 30, 2001.

    (5) Until October 1, 2005, proper shipping names that included the word “inhibited” prior to the June 21, 2001 final rule in effect on October 1, 2001, may continue to be shown on packagings in place of “stabilized.”

    Start Part

    PART 172—HAZARDOUS MATERIALS TABLE, SPECIAL PROVISIONS,HAZARDOUS MATERIALS COMMUNICATIONS, EMERGENCY RESPONSE INFORMATION,AND TRAINING REQUIREMENTS

    End Part Start Amendment Part

    9. The authority citation for part 172 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 49 U.S.C. 5101-5127; 49 CFR 1.53.

    End Authority Start Amendment Part

    10-11. In § 172.101, paragraphs (b)(1) and (c)(11) are revised, new paragraphs (c)(16) and (k)(6) through (k)(20) are added, and the Hazardous Materials Table is revised to read as follows:

    End Amendment Part
    Purpose and use of hazardous materials table.
    * * * * *

    (b) * * *

    (1) The plus (+) sign fixes the proper shipping name, hazard class and packing group for that entry without regard to whether the material meets the definition of that class, packing group or any other hazard class definition. When the plus sign is assigned to a proper shipping name in Column (1) of the § 172.101 Table, it means that the material is known to pose a risk to humans. When a plus sign is assigned to mixtures or solutions containing a material where the hazard to humans is significantly different from that of the pure material or where no hazard to humans is posed, the material may be described using an alternative shipping name that represents the hazards posed by the material. An appropriate alternate proper shipping name and hazard class may be authorized by the Associate Administrator.

    * * * * *

    (c) * * *

    (11) Except for a material subject to or prohibited by §§ 173.21, 173.54, 173.56(d), 173.56(e), 173.224(c) or 173.225(c) of this subchapter, a material that is considered to be a hazardous waste or a sample of a material for which the hazard class is uncertain and must be determined by testing may be assigned a tentative proper shipping name, hazard class, identification number and packing group, if applicable, based on the shipper's tentative determination according to:

    (i) Defining criteria in this subchapter;

    (ii) The hazard precedence prescribed in § 173.2a of this subchapter;

    (iii) The shippers knowledge of the material;

    (iv) In addition to paragraphs (c)(11)(i) through (iii) of this section, for a sample of a material, other than a waste, the following must be met:

    (A) Except when the word “Sample” already appears in the proper shipping name, the word “Sample” must appear in association with the basic description of a sample on the shipping paper;

    (B) When the proper shipping description for a sample is assigned a “G” in Column (1) of the § 172.101 Table, and the primary constituent(s) for which the tentative classification is based are not known, the provisions requiring a technical name for the constituent(s) do not apply; and

    (C) A sample must be transported in a combination packaging which conforms to the requirements of this subchapter that are applicable to the tentative packing group assigned, and may not exceed a net mass of 2.5 kg. (5.5 pounds) per package.

    Note to Paragraph (c)(11):

    For the transportation of self-reactive, organic peroxide and explosive samples, see §§ 173.224(c)(3), 173.225(c)(2) and 173.56(d) of this subchapter, respectively.

    * * * * *

    (16) Unless it is already included in the proper shipping name in the § 172.101 Table, the qualifying words “liquid” or “solid” may be added in association with the proper shipping name when a hazardous material specifically listed by name in the § 172.101 Table may, due to the differing physical states of the various isomers of the material, be either a liquid or a solid (for example “Dinitrotoluenes, liquid” and “Dinitrotoluenes, solid”). Use of the words “liquid” or “solid” is subject to the limitations specified for the use of the words “mixture” or “solution” in paragraph (c)(10) of this section. The qualifying word “molten” may be added in association with the proper shipping name when a hazardous material, which is a solid in accordance with the definition in § 171.8 of this subchapter, is offered for transportation in the molten state (for example, “Alkylphenols, solid, n.o.s., molten”).

    * * * * *

    (k) * * *

    (6) Stowage category “01” means the material may be stowed “on deck” or “under deck” on a cargo vessel (up to 12 passengers) and on a passenger vessel.

    (7) Stowage category “02” means the material may be stowed “on deck” or “under deck” on a cargo vessel (up to 12 passengers) and “on deck” in closed cargo transport units or “under deck” in closed cargo transport units on a passenger vessel.

    (8) Stowage category “03” means the material may be stowed “on deck” or “under deck” on a cargo vessel (up to 12 passengers) and “on deck” in closed cargo transport units on a passenger vessel.

    (9) Stowage category “04” means the material may be stowed “on deck” or “under deck” on a cargo vessel (up to 12 passengers) but the material is prohibited on a passenger vessel.

    (10) Stowage category “05” means the material may be stowed “on deck” in closed cargo transport units or “under deck” on a cargo vessel (up to 12 passengers) and on a passenger vessel.

    (11) Stowage category “06” means the material may be stowed “on deck” in closed cargo transport units or “under deck” on a cargo vessel (up to 12 passengers) and “on deck” in closed cargo transport units or “under deck” in closed cargo transport units on a passenger vessel.

    (12) Stowage category “07” means the material may be stowed “on deck” in closed cargo transport units or “under deck” on a cargo vessel (up to 12 passengers) and “on deck” only in closed cargo transport units on a passenger vessel.

    (13) Stowage category “08” means the material may be stowed “on deck” in closed cargo transport units or “under deck” on a cargo vessel (up to 12 passengers) but the material is prohibited on a passenger vessel.

    (14) Stowage category “09” means the material may be stowed “on deck only” in closed cargo transport units or “under deck” in closed cargo transport units on a cargo vessel (up to 12 passengers) and on a passenger vessel.

    (15) Stowage category “10” means the material may be stowed “on deck” in closed cargo transport units or “under deck” in closed cargo transport units on a cargo vessel (up to 12 passengers) and “on deck” only in closed cargo transport units on a passenger vessel.

    (16) Stowage category “11” means the material may be stowed “on deck” in closed cargo transport units or “under deck” in magazine stowage type “c” on a cargo vessel (up to 12 passengers) and Start Printed Page 33338“on deck” only in closed cargo transport units on a passenger vessel.

    (17) Stowage category “12” means the material may be stowed “on deck” in closed cargo transport units or “under deck” in magazine stowage type “c” on a cargo vessel (up to 12 passengers) but the material is prohibited on a passenger vessel.

    (18) Stowage category “13” means the material may be stowed “on deck” in closed cargo transport units or “under deck” in magazine stowage type “A” on a cargo vessel (up to 12 passengers) and “on deck” only in closed cargo transport units on a passenger vessel.

    (19) Stowage category “14” means the material may be stowed “on deck” in closed cargo transport units on a cargo vessel (up to 12 passengers) but the material is prohibited on a passenger vessel.

    (20) Stowage category “15” means the material may be stowed “on deck” in closed cargo transport units or “under deck” in closed cargo transport units on a cargo vessel (up to 12 passengers) but the material is prohibited on a passenger vessel.

    * * * * *

    § 172.101 Hazardous Materials Table

    SymbolsHazardous materials descriptions and proper shipping namesHazard class or DivisionIdentification NumbersPGLabel CodesSpecial provisions (§172.102)(8) Packaging (§173.***)(9) Quantity limitations(10) Vessel stowage
    ExceptionsNon-bulkBulkPassenger aircraft/railCargo air- craft onlyLocationOther
    (1)(2)(3)(4)(5)(6)(7)(8A)(8B)(8C)(9A)(9B)(10A)(10B)
    Accellerene, see p-Nitrosodimethylaniline
    Accumulators, electric, see Batteries, wet etc
    Acetal3UN1088II3IB2, T4, TP11502022425 L60 LE
    Acetaldehyde3UN1089I3A3, B16, T11, TP2, TP7None201243Forbidden30 LE
    AAcetaldehyde ammonia9UN1841III9IB8, IP6155204240200 kg200 kgA34
    Acetaldehyde oxime3UN2332III3B1, IB3, T4, TP115020324260 L220 LA
    Acetic acid, glacial or Acetic acid solution, with more than 80 percent acid, by mass8UN2789II8, 3A3, A6, A7, A10, B2, IB2, T7, TP21542022431 L30 LA
    Acetic acid solution, not less than 50 percent but not more than 80 percent acid, by mass8UN2790II8A3, A6, A7, A10, B2, IB2, T7, TP21542022421 L30 LA
    Acetic acid solution, with more than 10 percent and less than 50 percent acid, by mass8UN2790III8IB3, T4, TP11542032425 L60 LA
    Acetic anhydride8UN1715II8, 3A3, A6, A7, A10, B2, IB2, T7, TP21542022431 L30 LA40
    Acetone3UN1090II3IB2, T4, TP11502022425 L60 LB
    Acetone cyanohydrin, stabilized6.1UN1541I6.12, A3, B9, B14, B32, B76, B77, N34, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD25, 40, 49
    Acetone oils3UN1091II3IB2, T4, TP1, TP81502022425 L60 LB
    Acetonitrile3UN1648II3IB2, T7, TP21502022425L60 LB40
    Acetyl acetone peroxide with more than 9 percent by mass active oxygenForbidden
    Acetyl benzoyl peroxide, solid, or with more than 40 percent in solutionForbidden
    Acetyl bromide8UN1716II8B2, IB2, T8, TP2, TP121542022421 L30 LC40
    Acetyl chloride3UN1717II3, 8A3, A6, A7, IB1, N34, T8, TP2, TP12None2022431 L5 LB40
    Acetyl cyclohexanesulfonyl peroxide, with more than 82 percent wetted with less than 12 percent waterForbidden
    Acetyl iodide8UN1898II8B2, IB2, T7, TP2, TP131542022421 L30 LC40
    Acetyl methyl carbinol3UN2621III3B1, IB3, T2, TP115020324260 L220 LA
    Acetyl peroxide, solid, or with more than 25 percent in solutionForbidden
    Acetylene, dissolved2.1UN10012.1None303NoneForbidden15 kgD25, 40, 57
    Acetylene (liquefied)Forbidden
    Acetylene silver nitrateForbidden
    Acetylene tetrabromide, see Tetrabromoethane
    Acid butyl phosphate, see Butyl acid phosphate
    Acid, sludge, see Sludge acid
    Acridine6.1UN2713III6.1IB8, IP3153213240100 kg200 kgA
    Acrolein dimer, stabilized3UN2607III3B1, IB3, T2, TP115020324260 L220 LA40
    Acrolein, stabilized6.1UN1092I6.1, 31, B9, B14, B30, B42, B72, B77, T22, TP2, TP7, TP13, TP38, TP44None226244ForbiddenForbiddenD40
    Acrylamide6.1UN2074III6.1IB8, IP3, T4, TP1153213240100 kg200 kgA12
    Acrylic acid, stabilized8UN2218II8, 3B2, IB2, T7, TP21542022431 L30 LC25, 40
    Acrylonitrile, stabilized3UN1093I3, 6.1B9, T14, TP2, TP13None201243Forbidden30 LE40
    Actuating cartridge, explosive, see Cartridges, power device
    Adhesives, containing a flammable liquid3UN1133I3B42, T11, TP1, TP8, TP271502012431 L30 LB
    Start Printed Page 33339
    II3B52, IB2, T4, TP1, TP81501732425 L60 LB
    III3B1, B52, IB3, T2, TP115017324260 L220 LA
    Adiponitrile6.1UN2205III6.1IB3, T3, TP115320324160 L220 LA
    Aerosols, corrosive, Packing Group II or III, (each not exceeding 1 L capacity)2.2UN19502.2, 8A34306NoneNone75 kg150 kgA40, 48, 85
    Aerosols, flammable, (each not exceeding 1 L capacity)2.1UN19502.1N82306NoneNone75 kg150 kgA40, 48, 85
    Aerosols, flammable, n.o.s. (engine starting fluid) (each not exceeding 1 L capacity)2.1UN19502.1N82306NoneNoneForbidden150 kgA40, 48, 85
    Aerosols, non-flammable, (each not exceeding 1 L capacity)2.2UN19502.2306, 307NoneNone75 kg150 kgA48, 85
    Aerosols, poison, each not exceeding 1 L capacity2.2UN19502.2306NoneNoneForbiddenForbiddenA40, 48, 85
    Air bag inflators, compressed gas or Air bag modules, compressed gas or Seat-belt pretensioners, compressed gas2.2UN33532.213316616616675 kg150 kgA
    Air bag inflators, pyrotechnic or Air bag modules, pyrotechnic or Seat-belt pretensioner, pyrotechnic1.4GUN0503II1.4G166166166Forbidden75 kg0224E
    Air bag inflators, pyrotechnic or Air bag modules, pyrotechnic or Seat-belt pretensioner, pyrotechnic9UN3268III916616616625 kg100 kgA
    Air, compressed2.2UN10022.27830630230275 kg150 kgA
    Air, refrigerated liquid, (cryogenic liquid)2.2UN10032.2, 5.1T75, TP5, TP22320316318, 319Forbidden150 kgD51
    Air, refrigerated liquid, (cryogenic liquid) non-pressurized2.2UN10032.2, 5.1T75, TP5, TP22320316318, 319ForbiddenForbiddenD51
    Aircraft engines (including turbines), see Engines, internal combustion
    Aircraft evacuation slides, see Life saving appliances etc
    Aircraft hydraulic power unit fuel tank (containing a mixture of anhydrous hydrazine and monomethyl hydrazine) (M86 fuel)3UN3165I3, 6.1, 8None172NoneForbidden42 LE
    Aircraft survival kits, see Life saving appliances etc
    GAlcoholates solution, n.o.s., in alcohol3UN3274II3, 8IB2None2022431 L5 LB
    Alcoholic beverages3UN3065II324, B1, IB2, T4, TP11502022425 L60 LA
    III324, B1, IB3, N11, T2, TP115020324260 L220 LA
    Alcohols, n.o.s.3UN1987I3T11, TP1, TP8, TP27None2012431 L30 LE
    II3IB2, T7, TP1, TP8, TP281502022425 L60 LB
    III3B1, IB3, T4, TP1, TP2915020324260 L220 LA
    GAlcohols, flammable, toxic, n.o.s.3UN1986I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LE40
    II3, 6.1IB2, T11, TP2, TP27None2022431 L60 LB40
    III3, 6.1B1, IB3, T7, TP1, TP28None20324260 L220 LA
    Aldehydes, n.o.s.3UN1989I3T11, TP1, TP27None2012431 L30 LE
    II3IB2, T7, TP1, TP8, TP281502022425 L60 LB
    III3B1, IB3, T4, TP1, TP2915020324260 L220 LA
    GAldehydes, flammable, toxic, n.o.s.3UN1988I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LE40
    II3, 6.1IB2, T11, TP2, TP27None2022431 L60 LB40
    III3, 6.1B1, IB3, T7, TP1, TP2815020324260 L220 LA
    Aldol6.1UN2839II6.1IB2, T7, TP2None2022435 L60 LA12
    GAlkali metal alcoholates, self-heating, corrosive, n.o.s.4.2UN3206II4.2, 864, IB5, IP2None21224215 kg50 kgB
    III4.2, 864, IB8, IP3None21324225 kg100 kgB
    Alkali metal alloys, liquid, n.o.s.4.3UN1421I4.3A2, A3, B48, N34None201244Forbidden1 LD
    Alkali metal amalgam, liquid4.3UN1389I4.3A2, A3, N34None201244Forbidden1 LD40
    Alkali metal amalgam, solid4.3UN1389I4.3IB4, IP1, N40None211242Forbidden15 kgD
    Alkali metal amides4.3UN1390II4.3A6, A7, A8, A19, A20, IB7, IP215121224115 kg50 kgE40
    Alkali metal dispersions, or Alkaline earth metal dispersions4.3UN1391I4.3A2, A3None201244Forbidden1 LD
    Start Printed Page 33340
    Alkaline corrosive liquids, n.o.s., see Caustic alkali liquids, n.o.s.
    GAlkaline earth metal alcoholates, n.o.s.4.2UN3205II4.265, IB6, IP2None21224115 kg50 kgB
    III4.265, IB8, IP3None21324125 kg100 kgB
    Alkaline earth metal alloys, n.o.s.4.3UN1393II4.3A19, IB7, IP215121224115 kg50 kgE
    Alkaline earth metal amalgams4.3UN1392I4.3A19, IB4, IP1, N34, N40None211242Forbidden15 kgD
    GAlkaloids, liquid, n.o.s., or Alkaloid salts, liquid, n.o.s.6.1UN3140I6.1A4, T14, TP2, TP27None2012431 L30 LA
    II6.1IB2, T11, TP2, TP27None2022435 L60 LA
    III6.1IB3, T7, TP1, TP2815320324160 L220 LA
    GAlkaloids, solid, n.o.s. or Alkaloid salts, solid, n.o.s. poisonous6.1UN1544I6.1IB7, IP1None2112425 kg50 kgA
    II6.1IB8, IP2, IP4None21224225 kg100 kgA
    III6.1IB8, IP3153213240100 kg200 kgA
    Alkyl sulfonic acids, liquid or Aryl sulfonic acids, liquid with more than 5 percent free sulfuric acid8UN2584II8B2, IB2, T8, TP2, TP12, TP131542022421 L30 LB
    Alkyl sulfonic acids, liquid or Aryl sulfonic acids, liquid with not more than 5 percent free sulfuric acid8UN2586III8IB3, T4, TP11542032415 L60 LB
    Alkyl sulfonic acids, solid or Aryl sulfonic acids, solid, with more than 5 percent free sulfuric acid8UN2583II8IB8, IP2, IP415421224015 kg50 kgA
    Alkyl sulfonic acids, solid or Aryl sulfonic acids, solid with not more than 5 percent free sulfuric acid8UN2585III8IB8, IP315421324025 kg100 kgA
    Alkylphenols, liquid, n.o.s. (including C2-C12 homologues)8UN3145I8T14, TP2None2012430.5 L2.5 LB
    II8IB2, T11, TP2, TP271542022421 L30 LB
    III8IB3, T7, TP1, TP281542032415 L60 LA
    Alkylphenols, solid, n.o.s. (including C2-C12 homologues)8UN2430I8IB7, IP1, T10, TP2, TP28None2112421 kg25 kgB
    II8IB8, IP2, IP4, T3, TP215421224015 kg50 kgB
    III8IB8, IP3, T3, TP115421324025 kg100 kgA
    Alkylsulfuric acids8UN2571II8B2, IB2, T8, TP2, TP12, TP131542022421 L30 LC14
    Allethrin, see Pesticides, liquid, toxic, n.o.s.
    Allyl acetate3UN2333II3, 6.1IB2, T7, TP1, TP13None2022431 L60 LE40
    Allyl alcohol6.1UN1098I6.1, 32, B9, B14, B32, B74, B77, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Allyl bromide3UN1099I3, 6.1T14, TP2, TP13None201243Forbidden30 LB40
    Allyl chloride3UN1100I3, 6.1T14, TP2, TP13None201243Forbidden30 LE40
    Allyl chlorocarbonate, see Allyl chloroformate
    Allyl chloroformate6.1UN1722I6.1, 3, 82, A3, B9, B14, B32, B74, N41, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Allyl ethyl ether3UN2335II3, 6.1IB2, T7, TP1, TP13None2022431 L60 LE40
    Allyl formate3UN2336I3, 6.1T14, TP2, TP13None201243Forbidden30 LE40
    Allyl glycidyl ether3UN2219III3B1, IB3, T2, TP115020324260 L220 LA
    Allyl iodide3UN1723II3, 8A3, A6, IB1, N34, T7, TP2, TP13None2022431 L5 LB40
    Allyl isothiocyanate, stabilized6.1UN1545II6.1, 3A3, A7, IB2, T7, TP2None202243Forbidden60 LD40
    Allylamine6.1UN2334I6.1, 32, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Allyltrichlorosilane, stabilized8UN1724II8, 3A7, B2, B6, IB2, N34, T7, TP2, TP13None202243Forbidden30 LC40
    Aluminum alkyl halides4.2UN3052I4.2, 4.3B9, B11, T21, TP2, TP7None181244ForbiddenForbiddenD
    Aluminum alkyl hydrides4.2UN3076I4.2, 4.3B9, B11, T21, TP2, TP7None181244ForbiddenForbiddenD
    Aluminum alkyls4.2UN3051I4.2, 4.3B9, B11, T21, TP2, TP7None181244ForbiddenForbiddenD
    Aluminum borohydride or Aluminum borohydride in devices4.2UN2870I4.2, 4.3B11None181244ForbiddenForbiddenD
    Aluminum bromide, anhydrous8UN1725II8IB8, IP2, IP415421224015 kg50 kgA40
    Aluminum bromide, solution8UN2580III8IB3, T4, TP11542032415 L60 LA
    Aluminum carbide4.3UN1394II4.3A20, IB7, IP2, N4115121224215 kg50 kgA
    Start Printed Page 33341
    Aluminum chloride, anhydrous8UN1726II8IB8, IP2, IP415421224015 kg50 kgA40
    Aluminum chloride, solution8UN2581III8IB3, T4, TP11542032415 L60 LA
    Aluminum dross, wet or hotForbidden
    Aluminum ferrosilicon powder4.3UN1395II4.3, 6.1A19, IB5, IP215121224215 kg50 kgA40, 85, 103
    III4.3, 6.1A19, A20, IB415121324125 kg100 kgA40, 85, 103
    Aluminum hydride4.3UN2463I4.3A19, N40None211242Forbidden15 kgE
    DAluminum, molten9NA9260III9IB3, T1, TP3NoneNone247ForbiddenForbiddenD
    Aluminum nitrate5.1UN1438III5.1A1, A29, IB8, IP315221324025 kg100 kgA
    Aluminum phosphate solution, see Corrosive liquids, etc
    Aluminum phosphide4.3UN1397I4.3, 6.1A8, A19, N40None211242Forbidden15 kgE40, 85
    Aluminum phosphide pesticides6.1UN3048I6.1A8, IB7, IP1None211242Forbidden15 kgE40, 85
    Aluminum powder, coated4.1UN1309II4.1IB8, IP2, IP415121224015 kg50 kgA13, 39, 101
    III4.1IB8, IP315121324025 kg100 kgA13, 39, 101
    Aluminum powder, uncoated4.3UN1396II4.3A19, A20, IB7, IP215121224215 kg50 kgA39
    III4.3A19, A20, IB8, IP415121324125 kg100 kgA39
    Aluminum resinate4.1UN2715III4.1IB615121324025 kg100 kgA
    Aluminum silicon powder, uncoated4.3UN1398III4.3A1, A19, IB8, IP415121324125 kg100 kgA40, 85, 103
    Aluminum smelting by-products or Aluminum remelting by-products4.3UN3170II4.3128, B115, IB7, IP2None21224215 kg50 kgB85, 103
    III4.3128, B115, IB8, IP4None21324125 kg100 kgB85, 103
    Amatols, see Explosives, blasting, type B
    GAmines, flammable, corrosive, n.o.s. or Polyamines, flammable, corrosive, n.o.s.3UN2733I3, 8T14, TP1, TP27None2012430.5 L2.5 LD40
    II3, 8IB2, T11, TP1, TP27None2022431 L5 LB40
    III3, 8B1, IB3, T7, TP1, TP281502032425 L60 LA40
    GAmines, liquid, corrosive, flammable, n.o.s. or Polyamines, liquid, corrosive, flammable, n.o.s.8UN2734I8, 3A3, A6, N34, T14, TP2, TP27None2012430.5 L2.5 LA
    II8, 3IB2, T11, TP2, TP27None2022431 L30 LA
    GAmines, liquid, corrosive, n.o.s, or Polyamines, liquid, corrosive, n.o.s.8UN2735I8A3, A6, B10, N34, T14, TP2, TP27None2012430.5 L2.5 LA
    II8B2, IB2, T11, TP1, TP271542022421 L30 LA
    III8IB3, T7, TP1, TP281542032415 L60 LA
    GAmines, solid, corrosive, n.o.s., or Polyamines, solid, corrosive n.o.s.8UN3259I8IB7, IP1None2112421 kg25 kgA
    II8IB8, IP2, IP415421224015 kg50 kgA
    III8IB8, IP315421324025 kg100 kgA
    2-Amino-4-chlorophenol6.1UN2673II6.1IB8, IP2, IP4None21224225 kg100 kgA
    2-Amino-5-diethylaminopentane6.1UN2946III6.1IB3, T4, TP115320324160 L220 LA
    2-Amino-4,6-Dinitrophenol, wetted with not less than 20 percent water by mass4.1UN3317I4.123, A8, A19, A20, N41None211None1 kg15 kgE28, 36
    2-(2-Aminoethoxy) ethanol8UN3055III8IB3, T4, TP11542032415 L60 LA
    N-Aminoethylpiperazine8UN2815III8IB3, T4, TP11542032415 L60 LA12
    +Aminophenols (o-; m-; p-)6.1UN2512III6.1IB8, IP3, T4, TP1153213240100 kg200 kgA
    Aminopropyldiethanolamine, see Amines, etc
    n-Aminopropylmorpholine, see Amines, etc
    Aminopyridines (o-; m-; p-)6.1UN2671II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgB12, 40
    IAmmonia, anhydrous2.3UN10052.3, 84, T50None304314, 315Forbidden25 kgD40, 57
    DAmmonia, anhydrous2.2UN10052.213, T50None304314, 315Forbidden25 kgD40, 57
    DAmmonia solution, relative density less than 0.880 at 15 degrees C in water, with more than 50 percent ammonia2.2UN33182.213, T50None304314, 315Forbidden25 kgD40, 57
    IAmmonia solution, relative density less than 0.880 at 15 degrees C in water, with more than 50 percent ammonia2.3UN33182.3, 84, T50None304314, 315Forbidden25 kgD40, 57
    Ammonia solutions, relative density between 0.880 and 0.957 at 15 degrees C in water, with more than 10 percent but not more than 35 percent ammonia8UN2672III8IB3, T7, TP11542032415 L60 LA40, 85
    Start Printed Page 33342
    Ammonia solutions, relative density less than 0.880 at 15 degrees C in water, with more than 35 percent but not more than 50 percent ammonia2.2UN20732.2306304314, 315Forbidden150 kgE40, 57
    Ammonium arsenate6.1UN1546II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Ammonium azideForbidden
    Ammonium bifluoride, solid, see Ammonium hydrogen difluoride, solid
    Ammonium bifluoride solution, see Ammonium hydrogen difluoride, solution
    Ammonium bromateForbidden
    Ammonium chlorateForbidden
    Ammonium dichromate5.1UN1439II5.1IB8, IP2, IP41522122425 kg25 kgA
    Ammonium dinitro-o-cresolate6.1UN1843II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgB36, 65, 66, 77
    Ammonium fluoride6.1UN2505III6.1IB8, IP3153213240100 kg200 kgA26
    Ammonium fluorosilicate6.1UN2854III6.1IB8, IP3153213240100 kg200 kgA26
    Ammonium fulminateForbidden
    Ammonium hydrogen sulfate8UN2506II8IB8, IP2, IP415421224015 kg50 kgA40
    Ammonium hydrogendifluoride, solid8UN1727II8IB8, IP2, IP4, N3415421224015 kg50 kgA25, 26, 40
    Ammonium hydrogendifluoride, solution8UN2817II8, 6.1IB2, N34, T8, TP2, TP12, TP13None2022431 L30 LB40
    III8, 6.1IB3, T4, TP1, TP12, TP131542032415 L60 LB40, 95
    Ammonium hydrosulfide, solution, see Ammonium sulfide solution
    DAmmonium hydroxide, see Ammonia solutions, etc
    Ammonium metavanadate6.1UN2859II6.1IB8, IP2, IP4None21224225 kg100 kgA
    DAmmonium nitrate fertilizers5.1NA2072III5.17, IB815221324025 kg100 kgB48, 59, 60, 117
    Ammonium nitrate fertilizers; uniform non-segregating mixtures of ammonium nitrate with added matter which is inorganic and chemically inert towards ammonium nitrate, with not less than 90 percent ammonium nitrate and not more than 0.2 percent combustible material (including organic material calculated as carbon), or with more than 70 percent but less than 90 percent ammonium nitrate and not more than 0.4 percent total combustible material5.1UN2067III5.152, IB8, IP315221324025 kg100 kgB48, 59, 60, 117
    A WAmmonium nitrate fertilizers: uniform non-segregating mixtures of nitrogen/phosphate or nitrogen/postash types or complete fertilizers of nitrogen/phosphate/postash type, with not more than 70 percent ammonium nitrate and not more than 0.4 percent total added combustible material or with not more than 45 percent ammonium nitrate with unrestricted combustible material9UN2071III9132, IB8155213240200 kg200 kgA
    DAmmonium nitrate-fuel oil mixture containing only prilled ammonium nitrate and fuel oil1.5DNA0331II1.5DNone62NoneForbiddenForbidden1019E
    Ammonium nitrate, liquid (hot concentrated solution)5.1UN24265.1B5, T7NoneNone243ForbiddenForbiddenD59, 60
    DAmmonium nitrate mixed fertlizers5.1NA2069III5.110, IB815221324025 kg100 kgB48, 59, 60, 117
    Ammonium nitrate, with more than 0.2 percent combustible substances, including any organic substance calculated as carbon, to the exclusion of any other added substance1.1DUN0222II1.1DNone62NoneForbiddenForbidden1019E
    Ammonium nitrate, with not more than 0.2 percent of combustible substances, including any organic substance calculated as carbon, to the exclusion of any other added substance5.1UN1942III5.1A1, A29, IB8, IP315221324025 kg100 kgA48, 59, 60, 116
    Ammonium nitriteForbidden
    Ammonium perchlorate1.1DUN0402II1.1D107None62NoneForbiddenForbidden1019E
    Ammonium perchlorate5.1UN1442II5.1107, A9, IB6, IP21522122425 kg25 kgE58, 69, 106
    Start Printed Page 33343
    Ammonium permanganateForbidden
    Ammonium persulfate5.1UN1444III5.1A1, A29, IB8, IP315221324025 kg100 kgA
    Ammonium picrate, dry or wetted with less than 10 percent water, by mass1.1DUN0004II1.1DNone62NoneForbiddenForbidden105E, 19E
    Ammonium picrate, wetted with not less than 10 percent water, by mass4.1UN1310I4.123, A2, N41None211None0.5 kg0.5 kgD28, 36
    Ammonium polysulfide, solution8UN2818II8, 6.1IB2, T7, TP2, TP13None2022431 L30 LB12, 26, 40
    III8, 6.1IB3, T4, TP1, TP131542032415 L60 LB12, 26, 40
    Ammonium polyvanadate6.1UN2861II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Ammonium silicofluoride, see Ammonium fluorosilicate
    Ammonium sulfide solution8UN2683II8, 6.1, 3IB1, T7, TP2, TP13None2022431 L30 LB12, 22, 26, 100
    Ammunition, blank, see Cartridges for weapons, blank
    Ammunition, illuminating with or without burster, expelling charge or propelling charge1.2GUN0171II1.2G62NoneForbiddenForbidden03
    Ammunition, illuminating with or without burster, expelling charge or propelling charge1.3GUN0254II1.3G62NoneForbiddenForbidden03
    Ammunition, illuminating with or without burster, expelling charge or propelling charge1.4GUN0297II1.4G62NoneForbidden75 kg02
    Ammunition, incendiary liquid or gel, with burster, expelling charge or propelling charge1.3JUN0247II1.3J62NoneForbiddenForbidden0423E
    Ammunition, incendiary (water-activated contrivances) with burster, expelling charge or propelling charge, see Contrivances, water-activated, etc.
    Ammunition, incendiary, white phosphorus, with burster, expelling charge or propelling charge1.2HUN0243II1.2H62NoneForbiddenForbidden088E, 14E, 15E, 17E
    Ammunition, incendiary, white phosphorus, with burster, expelling charge or propelling charge1.3HUN0244II1.3H62NoneForbiddenForbidden088E, 14E, 15E, 17E
    Ammunition, incendiary with or without burster, expelling charge, or propelling charge1.2GUN0009II1.2G62NoneForbiddenForbidden03
    Ammunition, incendiary with or without burster, expelling charge, or propelling charge1.3GUN0010II1.3G62NoneForbiddenForbidden03
    Ammunition, incendiary with or without burster, expelling charge or propelling charge1.4GUN0300II1.4G62NoneForbidden75 kg02
    Ammunition, practice1.4GUN0362II1.4G62NoneForbidden75 kg02
    Ammunition, practice1.3GUN0488II1.3G62NoneForbiddenForbidden03
    Ammunition, proof1.4GUN0363II1.4G62NoneForbidden75 kg02
    Ammunition, rocket, see Warheads, rocket etc
    Ammunition, SA (small arms), see Cartridges for weapons, etc
    Ammunition, smoke (water-activated contrivances), white phosphorus, with burster, expelling charge or propelling charge, see Contrivances, water-activated, etc. (UN 0248)
    Ammunition, smoke (water-activated contrivances), without white phosphorus or phosphides, with burster, expelling charge or propelling charge, see Contrivances, water-activated, etc. (UN 0249)
    Ammunition smoke, white phosphorus with burster,expelling charge, or propelling charge1.2HUN0245II1.2H62NoneForbiddenForbidden088E, 14E, 15E, 17E
    Ammunition, smoke, white phosphorus with burster, expelling charge, or propelling charge1.3HUN0246II1.3H62NoneForbiddenForbidden088E, 14E, 15E, 17E
    Ammunition, smoke with or without burster, expelling charge or propelling charge1.2GUN0015II1.2G, 862NoneForbiddenForbidden8E, 17E, 20E
    Start Printed Page 33344
    Ammunition, smoke with or without burster, expelling charge or propelling charge1.3GUN0016II1.3G, 862NoneForbiddenForbidden8E, 17E, 20E
    Ammunition, smoke with or without burster, expelling charge or propelling charge1.4GUN0303II1.4G, 862NoneForbidden75 kg7E, 8E, 14E, 15E, 17E
    Ammunition, sporting, see Cartridges for weapons, etc. (UN 0012; UN 0328; UN 0339)
    Ammunition, tear-producing, non-explosive, without burster or expelling charge, non-fuzed6.1UN2017II6.1, 8None212NoneForbidden50 kgE13, 40
    Ammunition, tear-producing with burster, expelling charge or propelling charge1.2GUN0018II1.2G, 8, 6.162NoneForbiddenForbidden8E, 17E, 20E
    Ammunition, tear-producing with burster, expelling charge or propelling charge1.3GUN0019II1.3G, 8, 6.162NoneForbiddenForbidden8E, 17E, 20E
    Ammunition, tear-producing with burster, expelling charge or propelling charge1.4GUN0301II1.4G, 8, 6.162NoneForbidden75 kg7E, 8E, 14E, 15E, 17E
    Ammunition, toxic, non-explosive, without burster or expelling charge, non-fuzed6.1UN2016II6.1None212NoneForbidden100 kgE13, 40
    Ammunition, toxic (water-activated contrivances), with burster, expelling charge or propelling charge, see Contrivances, water-activated, etc
    GAmmunition, toxic with burster, expelling charge, or propelling charge1.2KUN0020II1.2K, 6.162NoneForbiddenForbidden088E, 14E, 15E, 17E
    GAmmunition, toxic with burster, expelling charge, or propelling charge1.3KUN0021II1.3K, 6.162NoneForbiddenForbidden088E, 14E, 15E, 17E
    Amyl acetates3UN1104III3B1, IB3, T2, TP115020324260 L220 LA
    Amyl acid phosphate8UN2819III8IB3, T4, TP11542032415 L60 LA
    Amyl butyrates3UN2620III3B1, IB3, T2, TP115020324260 L220 LA
    Amyl chlorides3UN1107II3IB2, T4, TP11502022425 L60 LB
    Amyl formates3UN1109III3B1, IB3, T2, TP115020324260 L220 LA
    Amyl mercaptans3UN1111II3A3, IB2, T4, TP1None2022425 L60 LB95, 102
    n-Amyl methyl ketone3UN1110III3B1, IB3, T2, TP115020324260 L220 LA
    Amyl nitrate3UN1112III3B1, IB3, T2, TP115020324260 L220 LA40
    Amyl nitrites3UN1113II3IB2, T4, TP11502022425 L60 LE40
    Amylamines3UN1106II3, 8IB2, T7, TP1None2022431 L5 LB
    III3, 8B1, IB3, T4, TP11502032425 L60 LA
    Amyltrichlorosilane8UN1728II8A7, B2, B6, IB2, N34, T7, TP2, TP13None202242Forbidden30 LC40
    Anhydrous ammonia, see Ammonia, anhydrous
    Anhydrous hydrofluoric acid, see Hydrogen fluoride, anhydrous
    +Aniline6.1UN1547II6.1IB2, T7, TP2None2022435 L60 LA40
    Aniline hydrochloride6.1UN1548III6.1IB8, IP3153213240100 kg200 kgA
    Aniline oil, see Aniline
    Anisidines6.1UN2431III6.1IB3, T4, TP115320324160 L220 LA
    Anisole3UN2222III3B1, IB3, T2, TP115020324260 L220 LA
    Anisoyl chloride8UN1729II8B2, IB2, T7, TP21542022421 L30 LC40
    Anti-freeze, liquid, see Flammable liquids, n.o.s.
    Antimonous chloride, see Antimony trichloride
    Antimony compounds, inorganic, liquid, n.o.s.6.1UN3141III6.135, IB3, T7, TP1, TP2815320324160 L220 LA
    Antimony compounds, inorganic, solid, n.o.s.6.1UN1549III6.135, IB8, IP3153213240100 kg200 kgA
    Antimony lactate6.1UN1550III6.1IB8, IP3153213240100 kg200 kgA
    Antimony pentachloride, liquid8UN1730II8B2, IB2, T7, TP2None2022421 L30 LC40
    Antimony pentachloride, solutions8UN1731II8B2, IB2, T7, TP21542022421 L30 LC40
    III8IB3, T4, TP11542032415 L60 LC40
    Antimony pentafluoride8UN1732II8, 6.1A3, A6, A7, A10, IB2, N3, T7, TP2None202243Forbidden30 LD40
    Antimony potassium tartrate6.1UN1551III6.1IB8, IP3153213240100 kg200 kgA
    Antimony powder6.1UN2871III6.1IB8, IP3153213240100 kg200 kgA
    Antimony sulfide and a chlorate, mixtures ofForbidden
    Antimony sulfide, solid, see Antimony compounds, inorganic, n.o.s.
    Antimony trichloride, liquid8UN1733II8B2, IB21542022421 L30 LC40
    Antimony trichloride, solid8UN1733II8IB8, IP2, IP415421224015 kg50 kgA40
    Start Printed Page 33345
    Aqua ammonia, see Ammonia solution, etc
    Argon, compressed2.2UN10062.2306302314, 31575 kg150 kgA
    Argon, refrigerated liquid (cryogenic liquid)2.2UN19512.2T75, TP532031631850 kg500 kgB
    Arsenic6.1UN1558II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Arsenic acid, liquid6.1UN1553I6.1T20, TP2, TP7, TP13None2012431 L30 LB46
    Arsenic acid, solid6.1UN1554II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Arsenic bromide6.1UN1555II6.1IB8, IP2, IP4None21224225 kg100 kgA12, 40
    Arsenic chloride, see Arsenic trichloride
    Arsenic compounds, liquid, n.o.s. inorganic, including arsenates, n.o.s.; arsenites, n.o.s.; arsenic sulfides, n.o.s.; and organic compounds of arsenic, n.o.s.6.1UN1556I6.1None2012431 L30 LB40
    II6.1IB2None2022435 L60 LB40
    III6.1IB315320324160 L220 LB40
    Arsenic compounds, solid, n.o.s. inorganic, including arsenates, n.o.s.; arsenites, n.o.s.; arsenic sulfides, n.o.s.; and organic compounds of arsenic, n.o.s.6.1UN1557I6.1IB7, IP1None2112425 kg50 kgA
    II6.1IB8, IP2, IP4None21224225 kg100 kgA
    III6.1IB8, IP3153213240100 kg200 kgA
    Arsenic pentoxide6.1UN1559II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Arsenic sulfide and a chlorate, mixtures ofForbidden
    Arsenic trichloride6.1UN1560I6.12, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenB40
    Arsenic trioxide6.1UN1561II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Arsenic, white, solid, see Arsenic trioxide
    Arsenical dust6.1UN1562II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Arsenical pesticides, liquid, flammable, toxic , flash point less than 23 degrees C3UN2760I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Arsenical pesticides, liquid, toxic6.1UN2994I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Arsenical pesticides, liquid, toxic, flammable flash point not less than 23 degrees C6.1UN2993I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3B1, IB3, T7, TP2, TP2815320324260 L220 LA40
    Arsenical pesticides, solid, toxic6.1UN2759I6.1IB7, IP1None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Arsenious acid, solid, see Arsenic trioxide
    Arsenious and mercuric iodide solution, see Arsenic compounds, liquid, n.o.s.
    Arsine2.3UN21882.3, 2.11None192245ForbiddenForbiddenD40
    Articles, explosive, extremely insensitive or Articles, EEI1.6NUN0486II1.6N101None62NoneForbiddenForbidden07
    GArticles, explosive, n.o.s.1.4SUN0349II1.4S101None62None25 kg100 kg05
    GArticles, explosive, n.o.s.1.4BUN0350II1.4B101None62NoneForbiddenForbidden06
    GArticles, explosive, n.o.s.1.4CUN0351II1.4C101None62NoneForbidden75 kg06
    GArticles, explosive, n.o.s.1.4DUN0352II1.4D101None62NoneForbidden75 kg06
    GArticles, explosive, n.o.s.1.4GUN0353II1.4G101None62NoneForbidden75 kg06
    GArticles, explosive, n.o.s.1.1LUN0354II1.1L101None62NoneForbiddenForbidden088E, 14E, 15E, 17E
    GArticles, explosive, n.o.s.1.2LUN0355II1.2L101None62NoneForbiddenForbidden088E, 14E, 15E, 17E
    GArticles, explosive, n.o.s.1.3LUN0356II1.3L101None62NoneForbiddenForbidden088E, 14E, 15E, 17E
    GArticles, explosive, n.o.s.1.1CUN0462II1.1C101None62NoneForbiddenForbidden07
    GArticles, explosive, n.o.s.1.1DUN0463II1.1D101None62NoneForbiddenForbidden07
    GArticles, explosive, n.o.s.1.1EUN0464II1.1E101None62NoneForbiddenForbidden07
    GArticles, explosive, n.o.s.1.1FUN0465II1.1F101None62NoneForbiddenForbidden08
    GArticles, explosive, n.o.s.1.2CUN0466II1.2C101None62NoneForbiddenForbidden07
    Start Printed Page 33346
    GArticles, explosive, n.o.s.1.2DUN0467II1.2D101None62NoneForbiddenForbidden07
    GArticles, explosive, n.o.s.1.2EUN0468II1.2E101None62NoneForbiddenForbidden07
    GArticles, explosive, n.o.s.1.2FUN0469II1.2F101None62NoneForbiddenForbidden08
    GArticles, explosive, n.o.s.1.3CUN0470II1.3C101None62NoneForbiddenForbidden07
    GArticles, explosive, n.o.s.1.4EUN0471II1.4E101None62NoneForbidden75 kg06
    GArticles, explosive, n.o.s.1.4FUN0472II1.4F101None62NoneForbiddenForbidden08
    Articles, pressurized pneumatic or hydraulic containing non-flammable gas2.2UN31642.2306302, 304NoneNo limitNo limitA
    Articles, pyrophoric1.2LUN0380II1.2LNone62NoneForbiddenForbidden088E, 14E, 15E, 17E
    Articles, pyrotechnic for technical purposes1.1GUN0428II1.1GNone62NoneForbiddenForbidden07
    Articles, pyrotechnic for technical purposes1.2GUN0429II1.2GNone62NoneForbiddenForbidden07
    Articles, pyrotechnic for technical purposes1.3GUN0430II1.3GNone62NoneForbiddenForbidden07
    Articles, pyrotechnic for technical purposes1.4GUN0431II1.4GNone62NoneForbidden75 kg06
    Articles, pyrotechnic for technical purposes1.4SUN0432II1.4SNone62None25 kg100 kg05
    DAsbestos9NA2212III9IB8, IP2, IP4155216240200 kg200 kgA34, 40
    Ascaridole (organic peroxide)Forbidden
    DAsphalt, at or above its flash point3NA1999III3IB3, T1, TP3150203247ForbiddenForbiddenD
    DAsphalt, cut back, see Tars, liquid, etc
    Automobile, motorcycle, tractor, other self-propelled vehicle, engine, or other mechanical apparatus, see Vehicles or Battery etc
    A GAviation regulated liquid, n.o.s.9UN33349A35155204No limitNo limitA
    A GAviation regulated solid, n.o.s.9UN33359A35155204No limitNo limitA
    Azaurolic acid (salt of) (dry)Forbidden
    Azido guanidine picrate (dry)Forbidden
    5-Azido-1-hydroxy tetrazoleForbidden
    Azido hydroxy tetrazole (mercury and silver salts)Forbidden
    3-Azido-1,2-Propylene glycol dinitrateForbidden
    Azidodithiocarbonic acidForbidden
    Azidoethyl nitrateForbidden
    1-Aziridinylphosphine oxide-(tris), see Tris-(1-aziridinyl) phosphine oxide, solution
    Azodicarbonamide4.1UN3242II4.138, IB8151212240ForbiddenForbiddenD12, 61, 74
    Azotetrazole (dry)Forbidden
    Barium4.3UN1400II4.3A19, IB7, IP215121224115 kg50 kgE
    Barium alloys, pyrophoric4.2UN1854I4.2None181NoneForbiddenForbiddenD
    Barium azide, dry or wetted with less than 50 percent water, by mass1.1AUN0224II1.1A, 6.1111, 117None62NoneForbiddenForbidden12
    Barium azide, wetted with not less than 50 percent water, by mass4.1UN1571I4.1, 6.1A2None182NoneForbidden0.5 kgD28
    Barium bromate5.1UN2719II5.1, 6.1IB8, IP2, IP4None2122425 kg25 kgA56, 58, 106
    Barium chlorate5.1UN1445II5.1, 6.1A9, IB6, IP2, N34, T4, TP1None2122425 kg25 kgA56, 58, 106
    Barium compounds, n.o.s.6.1UN1564II6.1IB8, IP2, IP4None21224225 kg100 kgA
    III6.1IB8, IP3153213240100 kg200 kgA
    Barium cyanide6.1UN1565I6.1IB7, IP1, N74, N75None2112425 kg50 kgA26, 40
    Barium hypochlorite with more than 22 percent available chlorine5.1UN2741II5.1, 6.1A7, A9, IB8, IP2, IP4, N34152212None5 kg25 kgB56, 58, 106
    Barium nitrate5.1UN1446II5.1, 6.1IB8, IP2, IP4None2122425 kg25 kgA
    Barium oxide6.1UN1884III6.1IB8, IP3153213240100 kg200 kgA
    Barium perchlorate5.1UN1447II5.1, 6.1IB6, IP2, T4, TP1None2122425 kg25 kgA56, 58, 106
    Barium permanganate5.1UN1448II5.1, 6.1IB6, IP2None2122425 kg25 kgD56, 58, 69, 106, 107
    Barium peroxide5.1UN1449II5.1, 6.1IB6, IP2None2122425 kg25 kgA13, 75, 106
    Barium selenate, see Selenates or Selenites
    Barium selenite, see Selenates or Selenites
    Batteries, containing sodium4.3UN3292II4.3189189189ForbiddenNo limitA
    Start Printed Page 33347
    Batteries, dry, containing potassium hydroxide solid, electric, storage8UN3028III8None213None25 kg gross230 kg grossA
    Batteries, wet, filled with acid, electric storage8UN2794III815915915930 kg grossNo limitA
    Batteries, wet, non-spillable, electric storage8UN2800III8159159159No LimitNo LimitA
    Batteries, dry, not subject to the requirements of this subchapter130
    Battery fluid, acid8UN2796II8A3, A7, B2, B15, IB2, N6, N34, T8, TP2, TP121542022421 L30 LB
    Battery fluid, alkali8UN2797II8B2, IB2, N6, T7, TP21542022421 L30 LA
    Battery lithium type, see Lithium batteries etc
    Battery-powered vehicle or Battery-powered equipment9UN31719134220220NoneNo limitNo limit
    Battery, wet, filled with acid or alkali with vehicle or mechanical equipment containing an internal combustion engine, see Vehicle, etc. or Engines, internal combustion, etc
    +Benzaldehyde9UN1990III9IB3, T2, TP1155203241100 L220 LA
    Benzene3UN1114II3IB2, T4, TP11502022425 L60 LB40
    Benzene diazonium chloride (dry)Forbidden
    Benzene diazonium nitrate (dry)Forbidden
    Benzene phosphorus dichloride, see Phenyl phosphorus dichloride
    Benzene phosphorus thiodichloride, see Phenyl phosphorus thiodichloride
    Benzene sulfonyl chloride8UN2225III8IB3, T4, TP11542032415 L60 LA40
    Benzene triozonideForbidden
    Benzenethiol, see Phenyl mercaptan
    Benzidine6.1UN1885II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Benzol, see Benzene
    Benzonitrile6.1UN2224II6.1IB2, T7, TP2None2022435 L60 LA26, 40
    Benzoquinone6.1UN2587II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Benzotrichloride8UN2226II8B2, IB2, T7, TP21542022421 L30 LA40
    Benzotrifluoride3UN2338II3IB2, T4, TP11502022425 L60 LB40
    Benzoxidiazoles (dry)Forbidden
    Benzoyl azideForbidden
    Benzoyl chloride8UN1736II8B2, IB2, T8, TP2, TP12, TP131542022421 L30 LC40
    Benzyl bromide6.1UN1737II6.1, 8A3, A7, IB2, N33, N34, T8, TP2, TP12, TP13None2022431 L30 LD13, 40
    Benzyl chloride6.1UN1738II6.1, 8A3, A7, B70, IB2, N33, N42, T8, TP2, TP12, TP13None2022431 L30 LD13, 40
    Benzyl chloride unstabilized6.1UN1738II6.1, 8A3, A7, B8, B11, IB2, N33, N34, N43, T8, TP2, TP12, TP13None2022431 L30 LD13, 40
    Benzyl chloroformate8UN1739I8A3, A6, B4, N41, T10, TP2, TP12, TP13None201243Forbidden2.5 LD40
    Benzyl iodide6.1UN2653II6.1IB2, T7, TP2None2022435 L60 LB12, 40
    Benzyldimethylamine8UN2619II8, 3B2, IB2, T7, TP21542022431 L30 LA40, 48
    Benzylidene chloride6.1UN1886II6.1IB2, T7, TP2None2022435 L60 LD40
    Beryllium compounds, n.o.s.6.1UN1566II6.1IB8, IP2, IP4None21224225 kg100 kgA
    III6.1IB8, IP3153213240100 kg200 kgA
    Beryllium nitrate5.1UN2464II5.1, 6.1IB8, IP2, IP4None2122425 kg25 kgA
    Beryllium, powder6.1UN1567II6.1, 4.1IB8, IP2, IP4None21224215 kg50 kgA
    Bicyclo [2,2,1] hepta-2,5-diene, stabilized or 2,5-Norbornadiene, stabilized3UN2251II3IB2, T7, TP21502022425 L60 LD
    Biphenyl triozonideForbidden
    Bipyridilium pesticides, liquid, flammable, toxic , flash point less than 23 degrees C3UN2782I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LE
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Bipyridilium pesticides, liquid, toxic6.1UN3016I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Bipyridilium pesticides, liquid, toxic, flammable, flash point not less than 23 degrees C6.1UN3015I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB21, 40
    Start Printed Page 33348
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB21, 40
    III6.1, 3B1, IB3, T7, TP2, TP2815320324260 L220 LA21, 40
    Bipyridilium pesticides, solid, toxic6.1UN2781I6.1IB7, IP1None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Bis (Aminopropyl) piperazine, see Corrosive liquid, n.o.s.
    Bisulfate, aqueous solution8UN2837II8A7, B2, IB2, N34, T7, TP21542022421 L30 LA
    III8A7, IB3, N34, T4, TP11542032415 L60 LA
    Bisulfites, aqueous solutions, n.o.s.8UN2693III8IB3, T7, TP1, TP281542032415 L60 LA26, 40
    Black powder, compressed or Gunpowder, compressed or Black powder, in pellets or Gunpowder, in pellets1.1DUN0028II1.1DNone62NoneForbiddenForbidden10
    Black powder or Gunpowder, granular or as a meal1.1DUN0027II1.1DNone62NoneForbiddenForbidden10
    DBlack powder for small arms4.1NA0027I4.170None170NoneForbiddenForbiddenE
    Blasting agent, n.o.s., see Explosives, blasting etc
    Blasting cap assemblies, see Detonator assemblies, non-electric, for blasting
    Blasting caps, electric, see Detonators, electric for blasting
    Blasting caps, non-electric, see Detonators, non-electric, for blasting
    Bleaching powder, see Calcium hypochlorite mixtures, etc
    IBlue asbestos (Crocidolite) or Brown asbestos (amosite, mysorite)9UN2212II9IB8, IP2, IP4155216240ForbiddenForbiddenA34, 40
    Bombs, photo-flash1.1FUN0037II1.1F62NoneForbiddenForbidden08
    Bombs, photo-flash1.1DUN0038II1.1D62NoneForbiddenForbidden03
    Bombs, photo-flash1.2GUN0039II1.2G62NoneForbiddenForbidden03
    Bombs, photo-flash1.3GUN0299II1.3G62NoneForbiddenForbidden03
    Bombs, smoke, non-explosive, with corrosive liquid, without initiating device8UN2028II8None160NoneForbidden50 kgE40
    Bombs, with bursting charge1.1FUN0033II1.1F62NoneForbiddenForbidden08
    Bombs, with bursting charge1.1DUN0034II1.1D62NoneForbiddenForbidden03
    Bombs, with bursting charge1.2DUN0035II1.2D62NoneForbiddenForbidden03
    Bombs, with bursting charge1.2FUN0291II1.2F62NoneForbiddenForbidden08
    Bombs with flammable liquid, with bursting charge1.1JUN0399II1.1J62NoneForbiddenForbidden0423E
    Bombs with flammable liquid, with bursting charge1.2JUN0400II1.2J62NoneForbiddenForbidden0423E
    Boosters with detonator1.1BUN0225II1.1BNone62NoneForbiddenForbidden11
    Boosters with detonator1.2BUN0268II1.2BNone62NoneForbiddenForbidden07
    Boosters, without detonator1.1DUN0042II1.1DNone62NoneForbiddenForbidden07
    Boosters, without detonator1.2DUN0283II1.2DNone62NoneForbiddenForbidden07
    Borate and chlorate mixtures, see Chlorate and borate mixtures
    Borneol4.1UN1312III4.1A1, IB8, IP3None21324025 kg100 kgA
    +Boron tribromide8UN2692I8, 6.12, A3, A7, B9, B14, B32, B74, N34, T20, TP2, TP12, TP13, TP38, TP45None227244ForbiddenForbiddenC12
    Boron trichloride2.3UN17412.3, 83, B9, B14None304314ForbiddenForbiddenD25, 40
    Boron trifluoride, compressed2.3UN10082.32, B9, B14None302314, 315ForbiddenForbiddenD40
    Boron trifluoride acetic acid complex8UN1742II8B2, B6, IB2, T8, TP2, TP121542022421 L30 LA
    Boron trifluoride diethyl etherate8UN2604I8, 3A19, T10, TP2None2012430.5 L2.5 LD40
    Boron trifluoride dihydrate8UN2851II8IB8, IP2, IP4, T7, TP215421224015 kg50 kgB12, 40,
    Boron trifluoride dimethyl etherate4.3UN2965I4.3, 8, 3A19, T10, TP2, TP7None201243Forbidden1 LD21, 28, 40, 49, 100
    Boron trifluoride propionic acid complex8UN1743II8B2, IB2, T8, TP2, TP121542022421 L30 LA
    Box toe gum, see Nitrocellulose etc
    Bromates, inorganic, aqueous solution, n.o.s.5.1UN3213II5.1IB2, T4, TP11522022421 L5 LB56, 58, 106
    Bromates, inorganic, n.o.s.5.1UN1450II5.1IB8, IP2, IP41522122425 kg25 kgA56, 58, 106
    Bromine azideForbidden
    +Bromine or Bromine solutions8UN1744I8, 6.11, A3, A6, B9, B64, B85, N34, N43, T22, TP2, TP10, TP12, TP13None226249ForbiddenForbidden12, 40, 66, 74, 89, 90
    Start Printed Page 33349
    Bromine chloride2.3UN29012.3, 8, 5.12, B9, B14None304314, 315ForbiddenForbiddenD40, 89, 90
    +Bromine pentafluoride5.1UN1745I5.1, 6.1, 81, B9, B14, B30, B72, T22, TP2, TP12, TP13, TP38, TP44None228244ForbiddenForbiddenD25, 40, 66, 90
    +Bromine trifluoride5.1UN1746I5.1, 6.1, 82, B9, B14, B32, B74, T22, TP2, TP12, TP13, TP38, TP45None228244ForbiddenForbiddenD25, 40, 66, 90
    4-Bromo-1,2-dinitrobenzeneForbidden
    4-Bromo-1,2-dinitrobenzene (unstable at 59 degrees C.)Forbidden
    1-Bromo-3-chloropropane6.1UN2688III6.1IB3, T4, TP115320324160 L220 LA
    1-Bromo-3-methylbutane3UN2341III3B1, IB3, T2, TP115020324260 L220 LA
    1-Bromo-3-nitrobenzene (unstable at 56 degrees C)Forbidden
    2-Bromo-2-nitropropane-1,3-diol4.1UN3241III4.146, IB8, IP3151213None25 kg50 kgC12, 25, 40
    Bromoacetic acid, solid8UN1938II8A7, IB8, IP2, IP4, N34, T715421224015 kg50 kgA
    Bromoacetic acid, solution8UN1938II8B2, IB2, T7, TP21542022421 L30 LA40
    +Bromoacetone6.1UN1569II6.1, 32, T20, TP2, TP13None193245ForbiddenForbiddenD40
    Bromoacetyl bromide8UN2513II8B2, IB2, T8, TP2, TP121542022421 L30 LC40
    Bromobenzene3UN2514III3B1, IB3, T2, TP115020324260 L220 LA
    Bromobenzyl cyanides, liquid6.1UN1694I6.1T14, TP2, TP13None201243Forbidden30 LD12, 40
    Bromobenzyl cyanides, solid6.1UN1694I6.1T14, TP2, TP13None211242Forbidden50 kgD12, 40
    1-Bromobutane3UN1126II3IB2, T4, TP11502022425L60 LB40
    2-Bromobutane3UN2339II3B1, IB2, T4, TP11502022425 L60 LB40
    Bromochloromethane6.1UN1887III6.1IB3, T4, TP115320324160 L220 LA
    2-Bromoethyl ethyl ether3UN2340II3IB2, T4, TP11502022425 L60 LB40
    Bromoform6.1UN2515III6.1IB3, T4, TP115320324160 L220 LA12, 40
    Bromomethylpropanes3UN2342II3IB2, T4, TP11502022425 L60 LB
    2-Bromopentane3UN2343II3IB2, T4, TP11502022425 L60 LB
    Bromopropanes3UN2344II3IB2, T4, TP11502022425 L60 LB40
    III3IB3, T2, TP115020324260 L220 LA
    3-Bromopropyne3UN2345II3IB2, T4, TP11502022425 L60 LD40
    BromosilaneForbidden
    Bromotoluene-alpha, see Benzyl bromide
    Bromotrifluoroethylene2.1UN24192.1None304314, 315Forbidden150 kgB40
    Bromotrifluoromethane or Refrigerant gas, R 13B1.2.2UN10092.2T50306304314, 31575 kg150 kgA
    Brucine6.1UN1570I6.1IB7, IP1None2112425 kg50 kgA
    Bursters, explosive1.1DUN0043II1.1DNone62NoneForbiddenForbidden07
    Butadienes, stabilized2.1UN10102.1T50306304314, 315Forbidden150 kgB40
    Butane see also Petroleum gases, liquefied2.1UN10112.119, T50306304314, 315Forbidden150 kgE40
    Butane, butane mixtures and mixtures having similar properties in cartridges each not exceeding 500 grams, see Receptacles, etc
    Butanedione3UN2346II3IB2, T4, TP11502022425 L60 LB
    1,2,4-Butanetriol trinitrateForbidden
    Butanols3UN1120II3IB2, T4, TP1, TP291502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    tert-Butoxycarbonyl azideForbidden
    Butyl acetates3UN1123II3IB2, T4, TP11502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Butyl acid phosphate8UN1718III8IB3, T4, TP11542032415 L60 LA
    Butyl acrylates, stabilized3UN2348III3B1, IB3, T2, TP115020324260 L220 LA
    Butyl alcohols, see Butanols
    Butyl benzenes3UN2709III3B1, IB3, T2, TP115020324260 L220 LA
    n-Butyl bromide, see 1-Bromobutane
    n-Butyl chloride, see Chlorobutanes
    Dsec-Butyl chloroformate6.1NA2742I6.1, 3, 82, B9, B14, B32, B74, T20, TP4, TP12, TP13, TP38, TP45None2272441 L30 LA12, 13, 22, 25, 40, 48, 100
    n-Butyl chloroformate6.1UN2743I6.1, 8, 32, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenA12, 13, 21, 25, 40, 100
    Butyl ethers, see Dibutyl ethers
    Butyl ethyl ether, see Ethyl butyl ether
    n-Butyl formate3UN1128II3IB2, T4, TP11502022425 L60 LB
    tert-Butyl hydroperoxide, with more than 90 percent with waterForbidden
    tert-Butyl hypochlorite4.2UN3255I4.2, 8None211243ForbiddenForbiddenD
    N-n-Butyl imidazole6.1UN2690II6.1IB2, T7, TP2None2022435 L60 LA
    Start Printed Page 33350
    tert-Butyl isocyanate6.1UN2484I6.1, 31, A7, B9, B14, B30, B72, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenD40
    n-Butyl isocyanate6.1UN2485I6.1, 32, A7, B9, B14, B32, B74, B77, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Butyl mercaptans3UN2347II3A3, IB2, T4, TP11502022425 L60 LD26, 95
    n-Butyl methacrylate, stabilized3UN2227III3B1, IB3, T2, TP115020324260 L220 LA
    Butyl methyl ether3UN2350II3IB2, T4, TP11502022425 L60 LB
    Butyl nitrites3UN2351I3T11, TP1, TP8, TP271502012431 L30 LE40
    II3IB2, T4, TP11502022425 L60 LB40
    III3B1, IB3, T2, TP115020324260 L220 LA40
    tert-Butyl peroxyacetate, with more than 76 percent in solutionForbidden
    n-Butyl peroxydicarbonate, with more than 52 percent in solutionForbidden
    tert-Butyl peroxyisobutyrate, with more than 77 percent in solutionForbidden
    Butyl phosphoric acid, see Butyl acid phosphate
    Butyl propionates3UN1914III3B1, IB3, T2, TP115020324260 L220 LA
    5-tert-Butyl-2,4,6-trinitro-m-xylene or Musk xylene4.1UN2956III4.1None214NoneForbiddenForbiddenD12
    Butyl vinyl ether, stabilized3UN2352II3IB2, T4, TP11502022425 L60 LB40
    n-Butylamine3UN1125II3, 8IB2, T7, TP1None2022421 L5 LB40
    N-Butylaniline6.1UN2738II6.1IB2, T7, TP2None2022435 L60 LA
    tert-Butylcyclohexylchloroformate6.1UN2747III6.1IB3, T4, TP115320324160 L220 LA12, 13, 25
    Butylene see also Petroleum gases, liquefied2.1UN10122.119, T50None304314, 315Forbidden150 kgE40
    1,2-Butylene oxide, stabilized3UN3022II3IB2, T4, TP11502022425 L60 LB49
    Butyltoluenes6.1UN2667III6.1IB3, T4, TP115320324160 L220 LA
    Butyltrichlorosilane8UN1747II8, 3A7, B2, B6, IB2, N34, T7, TP2, TP13None202243Forbidden30 LC40
    1,4-Butynediol6.1UN2716III6.1A1, IB8, IP3None213240100 kg200 kgA61, 70
    Butyraldehyde3UN1129II3IB2, T4, TP11502022425 L60 LB
    Butyraldoxime3UN2840III3B1, IB3, T2, TP115020324260 L220 LA
    Butyric acid8UN2820III8IB3, T4, TP11542032415 L60 LA12
    Butyric anhydride8UN2739III8IB3, T4, TP11542032415 L60 LA
    Butyronitrile3UN2411II3, 6.1IB2, T7, TP1, TP13None2022431 L60 LE40
    Butyryl chloride3UN2353II3, 8IB2, T8, TP2, TP12, TP13None2022431 L5 LC40
    Cacodylic acid6.1UN1572II6.1IB8, IP2, IP4None21224225 kg100 kgE26
    Cadmium compounds6.1UN2570I6.1IB7, IP1None2112425 kg50 kgA
    II6.1IB8, IP2, IP4None21224225 kg100 kgA
    III6.1IB8, IP3153213240100 kg200 kgA
    Caesium hydroxide8UN2682II8IB8, IP2, IP415421224015 kg50 kgA
    Caesium hydroxide solution8UN2681II8B2, IB2, T7, TP21542022421 L30 LA
    III8IB3, T4, TP11542032415 L60 LA
    Calcium4.3UN1401II4.3IB7, IP215121224115 kg50 kgE
    Calcium arsenate6.1UN1573II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Calcium arsenate and calcium arsenite, mixtures, solid6.1UN1574II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Calcium bisulfite solution, see Bisulfites, aqueous solutions, n.o.s.
    Calcium carbide4.3UN1402I4.3A1, A8, B55, B59, IB4, IP1, N34None211242Forbidden15 kgB
    II4.3A1, A8, B55, B59, IB7, IP2, N3415121224115 kg50 kgB
    Calcium chlorate5.1UN1452II5.1IB8, IP2, IP4, N341522122425 kg25 kgA56, 58, 106
    Calcium chlorate aqueous solution5.1UN2429II5.1A2, IB2, N41, T4, TP11522022421 L5 LB56, 58, 106
    III5.1A2, IB2, N41, T4, TP11522032412.5 L30 LB56, 68, 106
    Calcium chlorite5.1UN1453II5.1A9, IB8, IP2, IP4, N341522122425 kg25 kgA56, 58, 106
    Calcium cyanamide with more than 0.1 percent of calcium carbide4.3UN1403III4.3A1, A19, IB8, IP415121324125 kg100 kgA
    Calcium cyanide6.1UN1575I6.1IB7, IP1, N79, N80None2112425 kg50 kgA26, 40
    Calcium dithionite or Calcium hydrosulfite4.2UN1923II4.2A19, A20, IB6, IP2None21224115 kg50 kgE13
    Calcium hydride4.3UN1404I4.3A19, N40None211242Forbidden15 kgE
    Calcium hydrosulfite, see Calcium dithionite
    Start Printed Page 33351
    Calcium hypochlorite, dry or Calcium hypochlorite mixtures dry with more than 39 percent available chlorine (8.8 percent available oxygen)5.1UN1748II5.1A7, A9, IB8, IP2, IP4, N34, W9152212None5 kg25 kgD4, 5, 25, 48, 56, 58, 69
    Calcium hypochlorite, hydrated or Calcium hypochlorite, hydrated mixtures, with not less than 5.5 percent but not more than 10 percent water5.1UN2880II5.1IB8, IP2, IP4, W91522122405 kg25 kgD4, 5, 25, 48, 56, 58, 69
    Calcium hypochlorite mixtures, dry, with more than 10 percent but not more than 39 percent available chlorine5.1UN2208III5.1A1, A29, IB8, IP3, N34, W915221324025 kg100 kgD4, 5, 25, 48, 56, 58, 69
    Calcium manganese silicon4.3UN2844III4.3A1, A19, IB8, IP2, IP415121324125 kg100 kgA85, 103
    Calcium nitrate5.1UN1454III5.134, IB8, IP315221324025 kg100 kgA
    ACalcium oxide8UN1910III8IB8, IP315421324025 kg100 kgA
    Calcium perchlorate5.1UN1455II5.1IB6, IP21522122425 kg25 kgA56, 58, 106
    Calcium permanganate5.1UN1456II5.1IB6, IP21522122425 kg25 kgD56, 58, 69, 106, 107
    Calcium peroxide5.1UN1457II5.1IB6, IP21522122425 kg25 kgA13, 75, 106
    Calcium phosphide4.3UN1360I4.3, 6.1A8, A19, N40None211242Forbidden15 kgE40, 85
    Calcium, pyrophoric or Calcium alloys, pyrophoric4.2UN1855I4.2None187NoneForbiddenForbiddenD
    Calcium resinate4.1UN1313III4.1A1, A19, IB6None21324025 kg100 kgA
    Calcium resinate, fused4.1UN1314III4.1A1, A19, IB4None21324025 kg100 kgA
    Calcium selenate, see Selenates or Selenites
    Calcium silicide4.3UN1405II4.3A19, IB7, IP215121224115 kg50 kgB85, 103
    III4.3A1, A19, IB8, IP415121324125 kg100 kgB85, 103
    Camphor oil3UN1130III3B1, IB3, T2, TP115020324260 L220 LA
    Camphor, synthetic4.1UN2717III4.1A1, IB8, IP3None21324025 kg100 kgA
    Cannon primers, see Primers, tubular
    Caproic acid8UN2829III8IB3, T4, TP11542032415 L60 LA
    Caps, blasting, see Detonators, etc
    Carbamate pesticides, liquid, flammable, toxic , flash point less than 23 degrees C3UN2758I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Carbamate pesticides, liquid, toxic6.1UN2992I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Carbamate pesticides, liquid, toxic, flammable , flash point not less than 23 degrees C6.1UN2991I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3B1, IB3, T7, TP2, TP2815320324260 L220 LA40
    Carbamate pesticides, solid, toxic6.1UN2757I6.1IB7, IP1None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Carbolic acid, see Phenol, solid or Phenol, molten
    Carbolic acid solutions, see Phenol solutions
    ICarbon, activated4.2UN1362III4.2IB8, IP3None2132410.5 kg0.5 kgA12
    ICarbon, animal or vegetable origin4.2UN1361II4.2IB6None212242ForbiddenForbiddenA12
    III4.2IB8, IP3None213241ForbiddenForbiddenA12
    Carbon bisulfide, see Carbon disulfide
    Carbon dioxide2.2UN10132.2306302, 304302, 314, 31575 kg150 kgA
    Carbon dioxide and nitrous oxide mixtures2.2UN10152.2306None314, 31575 kg150 kgA
    Carbon dioxide and oxygen mixtures, compressed2.2UN10142.2, 5.177306304314, 31575 kg150 kgA
    Carbon dioxide, refrigerated liquid2.2UN21872.2T75, TP5306304314, 31550 kg500 kgB
    A WCarbon dioxide, solid or Dry ice9UN1845IIINone217217240200 kg200 kgC40
    Carbon disulfide3UN1131I3, 6.1B16, T14, TP2, TP7, TP13None201243ForbiddenForbiddenD18, 40, 115
    Carbon monoxide, compressed2.3UN10162.3, 2.14None302314, 315Forbidden25 kgD40
    Carbon monoxide and hydrogen mixture, compressed2.3UN26002.3, 2.16None302302ForbiddenForbiddenD40
    Start Printed Page 33352
    DCarbon monoxide, refrigerated liquid (cryogenic liquid)2.3NA92022.3, 2.14, T75, TP5None316318ForbiddenForbiddenD
    Carbon tetrabromide6.1UN2516III6.1IB8, IP3153213240100 kg200 kgA25
    Carbon tetrachloride6.1UN1846II6.1IB2, N36, T7, TP2None2022435 L60 LA40
    Carbonyl chloride, see Phosgene
    Carbonyl fluoride, compressed2.3UN24172.3, 82None302NoneForbiddenForbiddenD40
    Carbonyl sulfide2.3UN22042.3, 2.13, B14None304314, 315Forbidden25 kgD40
    Cartridge cases, empty primed, see Cases, cartridge, empty, with primer
    Cartridges, actuating, for aircraft ejector seat catapult, fire extinguisher, canopy removal or apparatus, see Cartridges, power device
    Cartridges, explosive, see Charges, demolition
    Cartridges, flash1.1GUN0049II1.1GNone62NoneForbiddenForbidden07
    Cartridges, flash1.3GUN0050II1.3GNone62NoneForbidden75 kg07
    Cartridges for weapons, blank1.1CUN0326II1.1CNone62NoneForbiddenForbidden07
    Cartridges for weapons, blank1.2CUN0413II1.2CNone62NoneForbiddenForbidden07
    Cartridges for weapons, blank or Cartridges, small arms, blank1.4SUN0014IINone6362None25 kg100 kg05
    Cartridges for weapons, blank or Cartridges, small arms, blank1.3CUN0327II1.3CNone62NoneForbiddenForbidden07
    Cartridges for weapons, blank or Cartridges, small arms, blank1.4CUN0338II1.4CNone62NoneForbidden75 kg06
    Cartridges for weapons, inert projectile1.2CUN0328II1.2CNone62NoneForbiddenForbidden03
    Cartridges for weapons, inert projectile or Cartridges, small arms1.4SUN0012IINone6362None25 kg100 kg05
    Cartridges for weapons, inert projectile or Cartridges, small arms1.4CUN0339II1.4CNone62NoneForbidden75 kg06
    Cartridges for weapons, inert projectile or Cartridges, small arms1.3CUN0417II1.3CNone62NoneForbiddenForbidden06
    Cartridges for weapons, with bursting charge1.1FUN0005II1.1FNone62NoneForbiddenForbidden08
    Cartridges for weapons, with bursting charge1.1EUN0006II1.1ENone62NoneForbiddenForbidden03
    Cartridges for weapons, with bursting charge1.2FUN0007II1.2FNone62NoneForbiddenForbidden08
    Cartridges for weapons, with bursting charge1.2EUN0321II1.2ENone62NoneForbiddenForbidden03
    Cartridges for weapons, with bursting charge1.4FUN0348II1.4FNone62NoneForbiddenForbidden08
    Cartridges for weapons, with bursting charge1.4EUN0412II1.4ENone62NoneForbidden75 kg02
    Cartridges, oil well1.3CUN0277II1.3CNone62NoneForbiddenForbidden07
    Cartridges, oil well1.4CUN0278II1.4CNone62NoneForbidden75 kg06
    Cartridges, power device1.3CUN0275II1.3CNone62NoneForbidden75 kg07
    Cartridges, power device1.4CUN0276II1.4C110None62NoneForbidden75 kg06
    Cartridges, power device1.4SUN0323II1.4S1106362None25 kg100 kg05
    Cartridges, power device1.2CUN0381II1.2CNone62NoneForbiddenForbidden07
    Cartridges, safety, blank, see Cartridges for weapons, blank (UN 0014)
    Cartridges, safety, see Cartridges for weapons, other than blank or Cartridges, power device (UN 0323)
    Cartridges, signal1.3GUN0054II1.3GNone62NoneForbidden75 kg07
    Cartridges, signal1.4GUN0312II1.4GNone62NoneForbidden75 kg06
    Cartridges, signal1.4SUN0405II1.4SNone62None25 kg100 kg05
    DCartridges, small armsORM-DNone63NoneNone30 kg gross30 kg grossA
    Cartridges, sporting, see Cartridges for weapons, other than blank
    Cartridges, starter, jet engine, see Cartridges, power device
    Cases, cartridge, empty with primer1.4SUN0055II1.4S50None62None25 kg100 kg05
    Cases, cartridges, empty with primer1.4CUN0379II1.4C50None62NoneForbidden75 kg06
    Cases, combustible, empty, without primer1.4CUN0446II1.4CNone62NoneForbidden75 kg06
    Cases, combustible, empty, without primer1.3CUN0447II1.3CNone62NoneForbiddenForbidden07
    Casinghead gasoline see Gasoline
    A WCastor beans or Castor meal or Castor pomace or Castor flake9UN2969IINoneIB8, IP2, IP4155204240No limitNo limitE34, 40
    GCaustic alkali liquids, n.o.s.8UN1719II8B2, IB2, T11, TP2, TP271542022421 L30 LA
    III8IB3, T7, TP1, TP281542032415 L60 LA
    Caustic potash, see Potassium hydroxide etc
    Start Printed Page 33353
    Caustic soda, (etc.) see Sodium hydroxide etc
    Cells, containing sodium4.3UN3292II4.318918918925 kg grossNo limitA
    Celluloid, in block, rods, rolls, sheets, tubes, etc., except scrap4.1UN2000III4.1None21324025 kg100 kgA
    Celluloid, scrap4.2UN2002III4.2IB8, IP3None213241ForbiddenForbiddenD
    Cement, see Adhesives containing flammable liquid
    Cerium, slabs, ingots, or rods4.1UN1333II4.1IB8, IP2, IP4, N34None21224015 kg50 kgA74, 91
    Cerium, turnings or gritty powder4.3UN3078II4.3A1, IB7, IP215121224215 kg50 kgE
    Cesium or Caesium4.3UN1407I4.3A19, IB1, IP1, N34, N40None211242Forbidden15 kgD
    Cesium nitrate or Caesium nitrate5.1UN1451III5.1A1, A29, IB8, IP315221324025 kg100 kgA
    DCharcoal briquettes, shell, screenings, wood, etc.4.2NA1361III4.2IB815121324025 kg100 kgA12
    Charges, bursting, plastics bonded1.1DUN0457II1.1DNone62NoneForbiddenForbidden07
    Charges, bursting, plastics bonded1.2DUN0458II1.2DNone62NoneForbiddenForbidden07
    Charges, bursting, plastics bonded1.4DUN0459II1.4DNone62NoneForbidden75 kg06
    Charges, bursting, plastics bonded1.4SUN0460II1.4SNone62None25 kg100 kg05
    Charges, demolition1.1DUN0048II1.1DNone62NoneForbiddenForbidden03
    Charges, depth1.1DUN0056II1.1DNone62NoneForbiddenForbidden03
    Charges, expelling, explosive, for fire extinguishers, see Cartridges, power device
    Charges, explosive, commercial without detonator1.1DUN0442II1.1DNone62NoneForbiddenForbidden07
    Charges, explosive, commercial without detonator1.2DUN0443II1.2DNone62NoneForbiddenForbidden07
    Charges, explosive, commercial without detonator1.4DUN0444II1.4DNone62NoneForbidden75 kg06
    Charges, explosive, commercial without detonator1.4SUN0445II1.4SNone62None25 kg100 kg05
    Charges, propelling1.1CUN0271II1.1CNone62NoneForbiddenForbidden07
    Charges, propelling1.3CUN0272II1.3CNone62NoneForbiddenForbidden07
    Charges, propelling1.2CUN0415II1.2CNone62NoneForbiddenForbidden07
    Charges, propelling1.4CUN0491II1.4CNone62NoneForbidden75 kg06
    Charges, propelling, for cannon1.3CUN0242II1.3CNone62NoneForbiddenForbidden10
    Charges, propelling, for cannon1.1CUN0279II1.1CNone62NoneForbiddenForbidden10
    Charges, propelling, for cannon1.2CUN0414II1.2CNone62NoneForbiddenForbidden10
    Charges, shaped, flexible, linear1.4DUN0237II1.4DNone62NoneForbidden75 kg06
    Charges, shaped, flexible, linear1.1DUN0288II1.1D101None62NoneForbiddenForbidden07
    Charges, shaped, without detonator1.1DUN0059II1.1DNone62NoneForbiddenForbidden07
    Charges, shaped, without detonator1.2DUN0439II1.2DNone62NoneForbiddenForbidden07
    Charges, shaped, without detonator1.4DUN0440II1.4DNone62NoneForbidden75 kg06
    Charges, shaped, without detonator1.4SUN0441II1.4SNone62None25 kg100 kg05
    Charges, supplementary explosive1.1DUN0060II1.1DNone62NoneForbiddenForbidden10
    DChemical kit8NA1760II8154161None1 L30 LB40
    Chemical kits9UN3316915NoneNoneNone10 kg10 kgA
    Chloral, anhydrous, stabilized6.1UN2075II6.1IB2, T7, TP2None2022435 L60 LD40
    Chlorate and borate mixtures5.1UN1458II5.1A9, IB8, IP2, IP4, N341522122405 kg25 kgA56, 58, 106
    III5.1A9, IB8, IP3, N3415221324025 kg100 kgA56, 58, 106
    Chlorate and magnesium chloride mixtures5.1UN1459II5.1A9, IB8, IP2, IP4, N34, T4, TP11522122405 kg25 kgA56, 58, 106
    III5.1A9, IB8, IP3, N34, T4, TP115221324025 kg100 kgA56, 58, 106
    Chlorate of potash, see Potassium chlorate
    Chlorate of soda, see Sodium chlorate
    Chlorates, inorganic, aqueous solution, n.o.s.5.1UN3210II5.1IB2, T4, TP11522022421 L5 LB56, 58, 106
    Chlorates, inorganic, n.o.s.5.1UN1461II5.1A9, IB6, IP2, N341522122425 kg25 kgA56, 58, 106
    Chloric acid aqueous solution, with not more than 10 percent chloric acid5.1UN2626II5.1IB2None229NoneForbiddenForbiddenD56, 58, 106
    Chloride of phosphorus, see Phosphorus trichloride
    Chloride of sulfur, see Sulfur chloride
    Chlorinated lime, see Calcium hypochlorite mixtures, etc
    Chlorine2.3UN10172.3, 82, B9, B14, T50, TP19None304314, 315ForbiddenForbiddenD40, 51, 55, 62, 68, 89, 90
    Start Printed Page 33354
    Chlorine azideForbidden
    DChlorine dioxide, hydrate, frozen5.1NA9191II5.1, 6.1None229NoneForbiddenForbiddenE
    Chlorine dioxide (not hydrate)Forbidden
    Chlorine pentafluoride2.3UN25482.3, 5.1, 81, B7, B9, B14None304314ForbiddenForbiddenD40, 89, 90
    Chlorine trifluoride2.3UN17492.3, 5.1, 82, B7, B9, B14None304314ForbiddenForbiddenD40, 89, 90
    Chlorite solution8UN1908II8A3, A6, A7, B2, IB2, N34, T7, TP2, TP241542022421 L30 LB26
    III8A3, A6, A7, B2, IB3, N34, T4, TP2, TP241542032415 L60 LB26
    Chlorites, inorganic, n.o.s.5.1UN1462II5.1A7, IB6, IP2, N341522122425 kg25 kgA56, 58, 106
    1-Chloro-1,1-difluoroethane or Refrigerant gas R 142b2.1UN25172.1T50306304314, 315Forbidden150 kgB40
    3-Chloro-4-methylphenyl isocyanate6.1UN2236II6.1IB2None2022435 L60 LB40
    1-Chloro-1,2,2,2-tetrafluoroethane or Refrigerant gas R 1242.2UN10212.2T50306304314, 31575 kg150 kgA
    4-Chloro-o-toluidine hydrochloride6.1UN1579III6.1IB8, IP3153213240100 kg200 kgA
    1-Chloro-2,2,2-trifluoroethane or Refrigerant gas R 133a2.2UN19832.2T50306304314, 31575 kg150 kgA
    Chloroacetic acid, molten6.1UN3250II6.1, 8IB1, T7, TP3None202243ForbiddenForbiddenC40
    Chloroacetic acid, solid6.1UN1751II6.1, 8A3, A7, IB8, IP4, N34None21224215 kg50 kgA40
    Chloroacetic acid, solution6.1UN1750II6.1, 8A7, IB2, N34, T7, TP2None2022431 L30 LC40
    Chloroacetone, stabilized6.1UN1695I6.1, 3, 82, B9, B14, B32, B74, N12, N32, N34, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD21, 40, 100
    Chloroacetone (unstabilized)Forbidden
    +Chloroacetonitrile6.1UN2668II6.1, 32, B9, B14, B32, B74, IB99, T20, TP2, TP38, TP45None227244ForbiddenForbiddenA12, 26, 40
    Chloroacetophenone (CN), liquid6.1UN1697II6.1A3, IB2, N12, N32, N33, T11, TP2, TP13, TP27None202243Forbidden60 LD12, 40
    Chloroacetophenone (CN), solid6.1UN1697II6.1A3, IB8, IP2, IP4, N12, N32, N33, N34, T7, TP2, TP13None212NoneForbidden100 kgD12, 40
    Chloroacetyl chloride6.1UN1752I6.1, 82, A3, A6, A7, B3, B8, B9, B14, B32, B74, B77, N34, N43, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Chloroanilines, liquid6.1UN2019II6.1IB2, T7, TP2None2022435 L60 LA
    Chloroanilines, solid6.1UN2018II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA
    Chloroanisidines6.1UN2233III6.1IB8, IP3153213240100 kg200 kgA
    Chlorobenzene3UN1134III3B1, IB3, T2, TP115020324260 L220 LA
    Chlorobenzol, see Chlorobenzene
    Chlorobenzotrifluorides3UN2234III3B1, IB3, T2, TP115020324260 L220 LA40
    Chlorobenzyl chlorides6.1UN2235III6.1IB3, T4, TP115320324160 L220 LA
    Chlorobutanes3UN1127II3IB2, T4, TP11502022425 L60 LB
    Chlorocresols, liquid6.1UN2669II6.1IB2, T7, TP2None2022435 L60 LA12
    Chlorocresols, solid6.1UN2669II6.1IB8, IP2, IP3, T7None21224225 kg100 kgA12
    Chlorodifluorobromomethane or Refrigerant gas R 12B12.2UN19742.2T50306304314, 31575 kg150 kgA
    Chlorodifluoromethane and chloropentafluoroethane mixture or Refrigerant gas R 502 with fixed boiling point, with approximately 49 percent chlorodifluoromethane2.2UN19732.2T50306304314, 31575 kg150 kgA
    Chlorodifluoromethane or Refrigerant gas R 222.2UN10182.2T50306304314, 31575 kg150 kgA
    +Chlorodinitrobenzenes6.1UN1577II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA91
    2-Chloroethanal6.1UN2232I6.12, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Chloroform6.1UN1888III6.1IB3, N36, T7, TP215320324160 L220 LA40
    GChloroformates, toxic, corrosive, flammable, n.o.s.6.1UN2742II6.1, 8, 35, IB1, T7, TP2None2022431 L30 LA12, 13, 21, 25, 40, 100
    GChloroformates, toxic, corrosive, n.o.s.6.1UN3277II6.1, 8IB2, T8, TP2, TP13, TP28None2022431 L30 LA12, 13, 25, 40
    Chloromethyl chloroformate6.1UN2745II6.1, 8IB2, T7, TP2, TP13None2022431 L30 LA12, 13, 21, 25, 40, 100
    Start Printed Page 33355
    Chloromethyl ethyl ether3UN2354II3, 6.1IB2, T7, TP1, TP13None2022431 L60 LE40
    Chloronitroanilines6.1UN2237III6.1IB8, IP3153213240100 kg200 kgA
    +Chloronitrobenzene, ortho, liquid6.1UN1578II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LA
    +Chloronitrobenzenes meta or para, solid6.1UN1578II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA
    Chloronitrotoluenes, liquid6.1UN2433III6.1IB3, T4, TP115320324160 L220 LA
    Chloronitrotoluenes, solid6.1UN2433III6.1IB8, IP3153213240100 kg200 kgA
    Chloropentafluoroethane or Refrigerant gas R 1152.2UN10202.2T50306304314, 31575 kg150 kgA
    Chlorophenolates, liquid or Phenolates, liquid8UN2904III8IB31542032415 L60 LA
    Chlorophenolates, solid or Phenolates, solid8UN2905III8IB8, IP315421324025 kg100 kgA
    Chlorophenols, liquid6.1UN2021III6.1IB3, T4, TP115320324160 L220 LA
    Chlorophenols, solid6.1UN2020III6.1IB8, IP3, T4, TP1153213240100 kg200 kgA
    Chlorophenyltrichlorosilane8UN1753II8A7, B2, B6, IB2, N34, T7, TP2None202242Forbidden30 LC40
    +Chloropicrin6.1UN1580I6.12, B7, B9, B14, B32, B46, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Chloropicrin and methyl bromide mixtures2.3UN15812.32, B9, B14, T50None193314, 315ForbiddenForbiddenD25, 40
    Chloropicrin and methyl chloride mixtures2.3UN15822.32, T50None193245ForbiddenForbiddenD25, 40
    Chloropicrin mixture, flammable (pressure not exceeding 14.7 psia at 115 degrees F flash point below 100 degrees F) see Toxic liquids, flammable, etc
    Chloropicrin mixtures, n.o.s.6.1UN1583I6.15None201243ForbiddenForbiddenC40
    II6.1IB2None202243ForbiddenForbiddenC40
    III6.1IB3153203241ForbiddenForbiddenC40
    DChloropivaloyl chloride6.1NA9263I6.1, 82, B9, B14, B32, B74, T20, TP4, TP12, TP13, TP38, TP45None227244ForbiddenForbiddenB40
    Chloroplatinic acid, solid8UN2507III8IB8, IP315421324025 kg100 kgA
    Chloroprene, stabilized3UN1991I3, 6.1B57, T14, TP2, TP13None201243Forbidden30 LD40
    Chloroprene, uninhibitedForbidden
    2-Chloropropane3UN2356I3N36, T11, TP2, TP131502012431 L30 LE
    3-Chloropropanol-16.1UN2849III6.1IB3, T4, TP115320324160 L220 LA
    2-Chloropropene3UN2456I3A3, N36, T11, TP21502012431 L30 LE
    2-Chloropropionic acid8UN2511III8IB3, T4, TP21542032415 L60 LA8
    2-Chloropyridine6.1UN2822II6.1IB2, T7, TP2None2022435 L60 LA40
    Chlorosilanes, corrosive, flammable, n.o.s.8UN2986II8, 3IB2, T11, TP2, TP27None2022431 L30 LC40
    Chlorosilanes, corrosive, n.o.s.8UN2987II8B2, IB2, T14, TP2, TP271542022421 L30 LC40
    Chlorosilanes, flammable, corrosive, n.o.s.3UN2985II3, 8IB1, T11, TP2, TP13, TP27None2012431 L5 LB40
    Chlorosilanes, water-reactive, flammable, corrosive, n.o.s.4.3UN2988I4.3, 3, 8A2, T10, TP2, TP7, TP13None201244Forbidden1 LD21, 28, 40, 49, 100
    +Chlorosulfonic acid (with or without sulfur trioxide)8UN1754I8, 6.12, A3, A6, A10, B9, B10, B14, B32, B74, T20, TP2, TP12, TP38, TP45None227244ForbiddenForbiddenC40
    Chlorotoluenes3UN2238III3B1, IB3, T2, TP115020324260 L220 LA
    Chlorotoluidines liquid6.1UN2239III6.1IB3, T7, TP1, TP2815320324160 L220 LA
    Chlorotoluidines solid6.1UN2239III6.1IB8, IP3, T4, TP1153213240100 kg200 kgA
    Chlorotrifluoromethane and trifluoromethane azeotropic mixture or Refrigerant gas R 503 with approximately 60 percent chlorotrifluoromethane2.2UN25992.2306304314, 31575 kg150 kgA
    Chlorotrifluoromethane or Refrigerant gas R 132.2UN10222.2306304314, 31575 kg150 kgA
    Chromic acid solution8UN1755II8B2, IB2, T8, TP2, TP121542022421 L30 LC40
    III8IB3, T4, TP1, TP121542032415 L60 LC40
    Chromic anhydride, see Chromium trioxide, anhydrous
    Chromic fluoride, solid8UN1756II8IB8, IP2, IP415421224015 kg50 kgA26
    Chromic fluoride, solution8UN1757II8B2, IB2, T7, TP21542022421 L30 LA
    III8IB3, T4, TP11542032415 L60 LA
    Chromium nitrate5.1UN2720III5.1A1, A29, IB8, IP315221324025 kg100 kgA
    Start Printed Page 33356
    Chromium oxychloride8UN1758I8A3, A6, A7, B10, N34, T10, TP2, TP12None2012430.5 L2.5 LC40, 66, 74, 89, 90
    Chromium trioxide, anhydrous5.1UN1463II5.1, 8IB8, IP4None2122425 kg25 kgA
    Chromosulfuric acid8UN2240I8A3, A6, A7, B4, B6, N34, T10, TP2, TP12, TP13None2012430.5 L2.5 LB40, 66, 74, 89, 90
    Chromyl chloride, see Chromium oxychloride
    Cigar and cigarette lighters, charged with fuel, see Lighters for cigars, cigarettes, etc
    Coal briquettes, hotForbidden
    Coal gas, compressed2.3UN10232.3, 2.13None302314, 315Forbidden25 kgD40
    Coal tar distillates, flammable3UN1136II3IB2, T4, TP11502022425 L60 LB
    III3B1, IB3, T4, TP1, TP2915020324260 L220 LA
    Coal tar dye, corrosive, liquid, n.o.s, see Dyes, liquid or solid, n.o.s. or Dye intermediates, liquid or solid, corrosive, n.o.s.
    Coating solution (includes surface treatments or coatings used for industrial or other purposes such as vehicle undercoating, drum or barrel lining)3UN1139I3T11, TP1, TP8, TP271502012431 L30 LE
    II3IB2, T4, TP1, TP81502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Cobalt naphthenates, powder4.1UN2001III4.1A19, IB8, IP315121324025 kg100 kgA
    Cobalt resinate, precipitated4.1UN1318III4.1A1, A19, IB615121324025 kg100 kgA
    Coke, hotForbidden
    Collodion, see Nitrocellulose etc
    D GCombustible liquid, n.o.s.CombustibleNA1993IIINoneIB3,T1, T4, TP115020324160 L220 LA
    GComponents, explosive train, n.o.s.1.2BUN0382II1.2B101None62NoneForbiddenForbidden11
    GComponents, explosive train, n.o.s.1.4BUN0383II1.4B101None62NoneForbidden75 kg06
    GComponents, explosive train, n.o.s.1.4SUN0384II1.4S101None62None25 kg100 kg05
    GComponents, explosive train, n.o.s.1.1BUN0461II1.1B101None62NoneForbiddenForbidden11
    Composition B, see Hexolite, etc
    D GCompounds, cleaning liquid8NA1760I8A7, B10, T14, TP2, TP9, TP27None2012430.5 L2.5 LB40
    II8B2, IB2, N37, T11, TP2, TP271542022421 L30 LB40
    III8IB3, N37, T7, TP1, TP281542032415 L60 LA40
    D GCompounds, cleaning liquid3NA1993I3T11, TP1, TP91502012431 L30 LE
    II3IB2, T7, TP1, TP8, TP281502022425 L60 LB
    III3B1, B52, IB3, T4, TP1, TP2915020324260 L220 LA
    D GCompounds, tree killing, liquid or Compounds, weed killing, liquid8NA1760I8A7, B10, T14, TP2, TP9, TP27None2012430.5 L2.5 LB40
    II8B2, IB2, N37, T11, TP2, TP271542022421 L30 LB40
    III8IB3, N37, T7, TP1, TP281542032415 L60 LA40
    D GCompounds, tree killing, liquid or Compounds, weed killing, liquid3NA1993I3T11, TP1, TP91502012431 L30 LE
    II3IB2, T7, TP1, TP8, TP281502022425 L60 LB
    III3B1, B52, IB3, T4, TP1, TP2915020324260 L220 LA
    D GCompounds, tree killing, liquid or Compounds, weed killing, liquid6.1NA2810I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP1, TP2815320324160 L220 LA40
    GCompressed gas, flammable, n.o.s.2.1UN19542.1306302, 305314, 315Forbidden150 kgD40
    GCompressed gas, n.o.s.2.2UN19562.2306, 307302, 305314, 31575 kg150 kgA
    GCompressed gas, oxidizing, n.o.s.2.2UN31562.2, 5.1306302314, 31575 kg150 kgD
    G ICompressed gas, toxic, corrosive, n.o.s. Inhalation Hazard Zone A2.3UN33042.3, 81None192245ForbiddenForbiddenD40
    G ICompressed gas, toxic, corrosive, n.o.s. Inhalation Hazard Zone B2.3UN33042.3, 82None302, 305314, 315ForbiddenForbiddenD40
    G ICompressed gas, toxic, corrosive, n.o.s. Inhalation Hazard Zone C2.3UN33042.3, 83None302, 305314, 315ForbiddenForbiddenD40
    G ICompressed gas, toxic, corrosive, n.o.s. Inhalation Hazard Zone D2.3UN33042.3, 84None302, 305314, 315ForbiddenForbiddenD40
    Start Printed Page 33357
    G ICompressed gas, toxic, flammable, corrosive, n.o.s. Inhalation Hazard Zone A2.3UN33052.3, 2.1, 81None192245ForbiddenForbiddenD17, 40
    G ICompressed gas, toxic, flammable, corrosive, n.o.s. Inhalation Hazard Zone B2.3UN33052.3, 2.1, 82None302, 305314, 315ForbiddenForbiddenD17, 40
    G ICompressed gas, toxic, flammable, corrosive, n.o.s. Inhalation Hazard Zone C2.3UN33052.3, 2.1, 83None302, 305314, 315ForbiddenForbiddenD17, 40
    G ICompressed gas, toxic, flammable, corrosive, n.o.s. Inhalation Hazard Zone D2.3UN33052.3, 2.1, 84None302, 305314, 315ForbiddenForbiddenD17, 40
    GCompressed gas, toxic, flammable, n.o.s. Inhalation hazard Zone A2.3UN19532.3, 2.11None192245ForbiddenForbiddenD40
    GCompressed gas, toxic, flammable, n.o.s. Inhalation hazard Zone B2.3UN19532.3, 2.12, B9, B14None302, 305314, 315ForbiddenForbiddenD40
    GCompressed gas, toxic, flammable, n.o.s. Inhalation Hazard Zone C2.3UN19532.3, 2.13, B14None302, 305314, 315ForbiddenForbiddenD40
    GCompressed gas, toxic, flammable, n.o.s. Inhalation Hazard Zone D2.3UN19532.3, 2.14None302, 305314, 315ForbiddenForbiddenD40
    GCompressed gas, toxic, n.o.s. Inhalation Hazard Zone A2.3UN19552.31None192245ForbiddenForbiddenD40
    GCompressed gas, toxic, n.o.s. Inhalation Hazard Zone B2.3UN19552.32, B9, B14None302, 305314, 315ForbiddenForbiddenD40
    GCompressed gas, toxic, n.o.s. Inhalation Hazard Zone C2.3UN19552.33, B14None302, 305314, 315ForbiddenForbiddenD40
    GCompressed gas, toxic, n.o.s. Inhalation Hazard Zone D2.3UN19552.34None302, 305314, 315ForbiddenForbiddenD40
    G ICompressed gas, toxic, oxdizing, corrosive, n.o.s. Inhalation Hazard Zone A2.3UN33062.3, 5.1, 81None192244ForbiddenForbiddenD40, 89, 90
    G ICompressed gas, toxic, oxidizing, corrosive, n.o.s. Inhalation Hazard Zone B2.3UN33062.3, 5.1, 82None302, 305314, 315ForbiddenForbiddenD40, 89, 90
    G ICompressed gas, toxic, oxidizing, corrosive, n.o.s. Inhalation Hazard Zone C2.3UN33062.3, 5.1, 83None302, 305314, 315ForbiddenForbiddenD40, 89, 90
    G ICompressed gas, toxic, oxidizing, corrosive, n.o.s. Inhalation Hazard Zone D2.3UN33062.3, 5.1, 84None302, 305314, 315ForbiddenForbiddenD40, 89, 90
    GCompressed gas, toxic, oxidizing, n.o.s. Inhalation Hazard Zone A2.3UN33032.3, 5.11None192245ForbiddenForbiddenD40
    GCompressed gas, toxic, oxidizing, n.o.s. Inhalation Hazard Zone B2.3UN33032.3, 5.12None302, 305314, 315ForbiddenForbiddenD40
    GCompressed gas, toxic, oxidizing, n.o.s. Inhalation Hazard Zone C2.3UN33032.3, 5.13None302, 305314, 315ForbiddenForbiddenD40
    GCompressed gas, toxic, oxidizing, n.o.s. Inhalation Hazard Zone D2.3UN33032.3, 5.14None302, 305314, 315ForbiddenForbiddenD40
    DConsumer commodityORM-DNone156, 306156, 306None30 kg gross30 kg grossA
    Contrivances, water-activated, with burster, expelling charge or propelling charge1.2LUN0248II1.2L101None62NoneForbiddenForbidden088E, 14E, 15E, 17E
    Contrivances, water-activated, with burster, expelling charge or propelling charge1.3LUN0249II1.3L101None62NoneForbiddenForbidden088E, 14E, 15E, 17E
    Copper acetoarsenite6.1UN1585II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Copper acetylideForbidden
    Copper amine azideForbidden
    Copper arsenite6.1UN1586II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Copper based pesticides, liquid, flammable, toxic , flash point less than 23 degrees C3UN2776I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Copper based pesticides, liquid, toxic6.1UN3010I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Copper based pesticides, liquid, toxic, flammable flash point not less than 23 degrees C6.1UN3009I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3B1, IB3, T7, TP2, TP2815320324260 L220 LA40
    Copper based pesticides, solid, toxic6.1UN2775I6.1IB7, IP1None2112425 kg50 kgA40
    Start Printed Page 33358
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Copper chlorate5.1UN2721II5.1A1, IB8, IP2, IP41522122425 kg25 kgA56, 58, 106
    Copper chloride8UN2802III8IB8, IP315421324025 kg100 kgA
    Copper cyanide6.1UN1587II6.1IB8, IP2, IP4None20424225 kg100 kgA26
    Copper selenate, see Selenates or Selenites
    Copper selenite, see Selenates or Selenites
    Copper tetramine nitrateForbidden
    A WCopra4.2UN1363III4.2IB8, IP3, IP6None213241ForbiddenForbiddenA13, 19, 48, 119
    Cord, detonating, flexible1.1DUN0065II1.1D10263(a)62NoneForbiddenForbidden07
    Cord, detonating, flexible1.4DUN0289II1.4DNone62NoneForbidden75 kg06
    Cord detonating or Fuse detonating metal clad1.2DUN0102II1.2DNone62NoneForbiddenForbidden07
    Cord, detonating or Fuse, detonating metal clad1.1DUN0290II1.1DNone62NoneForbiddenForbidden07
    Cord, detonating, mild effect or Fuse, detonating, mild effect metal clad1.4DUN0104II1.4DNone62NoneForbidden75 kg06
    Cord, igniter1.4GUN0066II1.4GNone62NoneForbidden75 kg06
    Cordeau detonant fuse, see Cord, detonating, etc; Cord, detonating, flexible
    Cordite, see Powder, smokeless
    GCorrosive liquid, acidic, inorganic, n.o.s.8UN3264I8B10, T14, TP2, TP27None2012430.5 L2.5 LB40
    II8B2, IB2, T11, TP2, TP271542022421 L30 LB40
    III8IB3, T7, TP1, TP281542032415 L60 LA40
    GCorrosive liquid, acidic, organic, n.o.s.8UN3265I8B10, T14, TP2, TP27None2012430.5 L2.5 LB40
    II8B2, IB2, T11, TP2, TP271542022421 L30 LB40
    III8IB3, T7, TP1, TP281542032415 L60 LA40
    GCorrosive liquid, basic, inorganic, n.o.s.8UN3266I8B10, T14, TP2, TP27None2012430.5 L2.5 LB40
    II8B2, IB2, T11, TP2, TP271542022421 L30 LB40
    III8IB3, T7, TP1, TP281542032415 L60 LA40
    GCorrosive liquid, basic, organic, n.o.s.8UN3267I8B10, T14, TP2, TP27None2012430.5 L2.5 LB40
    II8B2, IB2, T11, TP2, TP271542022421 L30 LB40
    III8IB3, T7, TP1, TP281542032415 L60 LA40
    GCorrosive liquid, self-heating, n.o.s.8UN3301I8, 4.2B10None2012430.5 L2.5 LD
    II8, 4.2B2, IB11542022421 L30 LD
    GCorrosive liquids, flammable, n.o.s.8UN2920I8, 3B10, T14, TP2, TP27None2012430.5 L2.5 LC25, 40
    II8, 3B2, IB2, T11, TP2, TP27None2022431 L30 LC25, 40
    GCorrosive liquids, n.o.s.8UN1760I8A7, B10, T14, TP2, TP27None2012430.5 L2.5 LB40
    II8B2, IB2, T11, TP2, TP271542022421 L30 LB40
    III8IB3, T7, TP1, TP281542032415 L60 LA40
    GCorrosive liquids, oxidizing, n.o.s.8UN3093I8, 5.1None201243Forbidden2.5 LC89
    II8, 5.1IB2None2022431 L30 LC89
    GCorrosive liquids, toxic, n.o.s.8UN2922I8, 6.1A7, B10, T14, TP2, TP13, TP27None2012430.5 L2.5 LB40
    II8, 6.1B3, IB2, T7, TP2None2022431 L30 LB40
    III8, 6.1IB3, T7, TP1, TP281542032415 L60 LB40
    GCorrosive liquids, water-reactive, n.o.s.8UN3094I8, 4.3None201243Forbidden1 LE
    II8, 4.3None2022431 L5 LE
    GCorrosive solid, acidic, inorganic, n.o.s.8UN3260I8IB7, IP1None2112421 kg25 kgB
    II8IB8, IP2, IP415421224015 kg50 kgB
    III8IB8, IP315421324025 kg100 kgA
    GCorrosive solid, acidic, organic, n.o.s.8UN3261I8IB7, IP1None2112421 kg25 kgB
    II8IB8, IP2, IP415421224015 kg50 kgB
    III8IB8, IP315421324025 kg100 kgA
    GCorrosive solid, basic, inorganic, n.o.s.8UN3262I8IB7, IP1None2112421 kg25 kgB
    II8IB8, IP2, IP415421224015 kg50 kgB
    III8IB8, IP315421324025 kg100 kgA
    GCorrosive solid, basic, organic, n.o.s.8UN3263I8IB7, IP1None2112421 kg25 kgB
    Start Printed Page 33359
    II8IB8, IP2, IP415421224015 kg50 kgB
    III8IB8, IP315421324025 kg100 kgA
    GCorrosive solids, flammable, n.o.s.8UN2921I8, 4.1IB6None2112421 kg25 kgB12, 25
    II8, 4.1IB8, IP2, IP4None21224215 kg50 kgB12, 25
    GCorrosive solids, n.o.s.8UN1759I8IB7, IP1None2112421 kg25 kgB
    II8128, IB8, IP2, IP415421224015 kg50 kgA
    III8128, IB8, IP315421324025 kg100 kgA
    GCorrosive solids, oxidizing, n.o.s.8UN3084I8, 5.1None2112421 kg25 kgC
    II8, 5.1IB6, IP2None21224215 kg50 kgC
    GCorrosive solids, self-heating, n.o.s.8UN3095I8, 4.2None2112431 kg25 kgC
    II8, 4.2IB6, IP2None21224215 kg50 kgC
    GCorrosive solids, toxic, n.o.s.8UN2923I8, 6.1IB7None2112421 kg25 kgB40
    II8, 6.1IB8, IP2, IP4None21224015 kg50 kgB40
    III8, 6.1IB8, IP315421324025 kg100 kgB40, 95
    GCorrosive solids, water-reactive, n.o.s.8UN3096I8, 4.3IB4, IP1None2112431 kg25 kgD
    II8, 4.3IB6, IP2None21224215 kg50 kgD
    D WCotton9NA13659137, IB8, IP2, IP4, W41NoneNoneNoneNo limitNo limitA
    A WCotton waste, oily4.2UN1364III4.2IB8, IP6None213NoneForbiddenForbiddenA54
    A I WCotton, wet4.2UN1365III4.2IB8, IP6None204241ForbiddenForbiddenA
    Coumarin derivative pesticides, liquid, flammable, toxic, flash point less than 23 degrees C3UN3024I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Coumarin derivative pesticides, liquid, toxic6.1UN3026I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP1, TP2815320324160 L220 LA40
    Coumarin derivative pesticides, liquid, toxic, flammable flash point not less than 23 degrees C6.1UN3025I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3B1, IB3, T7, TP1, TP2815320324260 L220 LA40
    Coumarin derivative pesticides, solid, toxic6.1UN3027I6.1IB7, IP1, T14, TP2, TP27None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4, T11, TP2, TP27None21224225 kg100 kgA40
    III6.1IB8, IP3, T7, TP1, TP28153213240100 kg200 kgA40
    Cresols6.1UN2076II6.1, 8IB8, IP2, IP4, T7, TP2None2022431 L30 LB
    Cresylic acid6.1UN2022II6.1, 8IB2, T7, TP2, TP13None2022431 L30 LB
    Crotonaldehyde, stabilized6.1UN1143I6.1, 32, B9, B14, B32, B74, B77, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenB40
    Crotonic acid liquid8UN2823III8IB3, T4, TP11542032415 L60 LA12
    Crotonic acid, solid8UN2823III8IB8, IP315421324025 kg100 kgA12
    Crotonylene3UN1144I3T11, TP21502012431 L30 LE
    Cupriethylenediamine solution8UN1761II8, 6.1IB2, T7, TP2None2022431 L30 LA
    III8, 6.1IB3, T7, TP1, TP281542032425 L60 LA95
    Cutters, cable, explosive1.4SUN0070II1.4SNone62None25 kg100 kg05
    Cyanide or cyanide mixtures, dry, see Cyanides, inorganic, solid, n.o.s.
    Cyanide solutions, n.o.s.6.1UN1935I6.1B37, T14, TP2, TP13, TP27None2012431 L30 LB40, 52
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LA40, 52
    III6.1IB3, T7, TP2, TP13, TP2815320324160 L220 LA40, 52
    Cyanides, inorganic, solid, n.o.s.6.1UN1588I6.1IB7, IP1, N74, N75None2112425 kg50 kgA52
    II6.1IB8, IP2, IP4, N74, N75None21224225 kg100 kgA52
    III6.1IB8, IP3, N74, N75153213240100 kg200 kgA52
    Cyanogen2.3UN10262.3, 2.12None192245ForbiddenForbiddenD40
    Cyanogen bromide6.1UN1889I6.1, 8A6, A8None2112421 kg15 kgD40
    Cyanogen chloride, stabilized2.3UN15892.3, 81None192245ForbiddenForbiddenD40
    Cyanuric chloride8UN2670II8IB8, IP2, IP4None21224015 kg50 kgA12, 40
    Cyanuric triazideForbidden
    Cyclobutane2.1UN26012.1306304314, 315Forbidden150 kgB40
    Cyclobutyl chloroformate6.1UN2744II6.1, 8, 3IB1, T7, TP2, TP13None2022431 L30 LA12, 13, 21, 25, 40, 100
    Start Printed Page 33360
    1,5,9-Cyclododecatriene6.1UN2518III6.1IB3, T4, TP115320324160 L220 LA40
    Cycloheptane3UN2241II3IB2, T4, TP11502022425 L60 LB40
    Cycloheptatriene3UN2603II3, 6.1IB2, T7, TP1, TP13None2022431 L60 LE40
    Cycloheptene3UN2242II3B1, IB2, T4, TP11502022425 L60 LB
    Cyclohexane3UN1145II3IB2, T4, TP11502022425 L60 LE
    Cyclohexanone3UN1915III3B1, IB3, T2, TP115020324260 L220 LA
    Cyclohexene3UN2256II3IB2, T4, TP11502022425 L60 LE
    Cyclohexenyltrichlorosilane8UN1762II8A7, B2, IB2, N34, T7, TP2, TP13None202242Forbidden30 LC40
    Cyclohexyl acetate3UN2243III3B1, IB3, T2, TP115020324260 L220 LA
    Cyclohexyl isocyanate6.1UN2488I6.1, 32, B9, B14, B32, B74, B77, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Cyclohexyl mercaptan3UN3054III3B1, IB3, T2, TP115020324260 L220 LA40, 95
    Cyclohexylamine8UN2357II8, 3IB2, T7, TP2None2022431 L30 LA40
    Cyclohexyltrichlorosilane8UN1763II8A7, B2, IB2, N34, T7, TP2, TP13None202242Forbidden30 LC40
    Cyclonite and cyclotetramethylenetetranitramine mixtures, wetted or desensitized see RDX and HMX mixtures, wetted or desensitized etc
    Cyclonite and HMX mixtures, wetted or desensitized see RDX and HMX mixtures, wetted or desensitized etc
    Cyclonite and octogen mixtures, wetted or desensitized see RDX and HMX mixtures, wetted or desensitized etc
    Cyclonite, see Cyclotrimethylenetrinitramine, etc
    Cyclooctadiene phosphines, see 9-Phosphabicyclononanes
    Cyclooctadienes3UN2520III3B1, IB3, T2, TP115020324260 L220 LA
    Cyclooctatetraene3UN2358II3IB2, T4, TP11502022425 L60 LB
    Cyclopentane3UN1146II3IB2, T7, TP11502022425 L60 LE
    Cyclopentane, methyl, see Methylcyclopentane
    Cyclopentanol3UN2244III3B1, IB3, T2, TP115020324260 L220 LA
    Cyclopentanone3UN2245III3B1, IB3, T2, TP115020324260 L220 LA
    Cyclopentene3UN2246II3IB2, IP8, T7, TP21502022425 L60 LE
    Cyclopropane2.1UN10272.1T50306304314, 315Forbidden150 kgE40
    Cyclotetramethylene tetranitramine (dry or unphlegmatized) (HMX)Forbidden
    Cyclotetramethylenetetranitramine, desensitized or Octogen, desensitized or HMX, desensitized1.1DUN0484II1.1DNone62NoneForbiddenForbidden10
    Cyclotetramethylenetetranitramine, wetted or HMX, wetted or Octogen, wetted with not less than 15 percent water, by mass1.1DUN0226II1.1DNone62NoneForbiddenForbidden10
    Cyclotrimethylenetrinitramine and cyclotetramethylenetetranitramine mixtures, wetted or desensitized see RDX and HMX mixtures, wetted or desensitized etc
    Cyclotrimethylenenitramine and octogen, mixtures, wetted or desensitized see RDX and HMX mixtures, wetted or desensitized etc
    Cyclotrimethylenetrinitramine and HMX mixtures, wetted or desensitized see RDX and HMX mixtures, wetted or desensitized etc
    Cyclotrimethylenetrinitramine, desensitized or Cyclonite, desensitized or Hexogen, desensitized or RDX, desensitized1.1DUN0483II1.1DNone62NoneForbiddenForbidden10
    Cyclotrimethylenetrinitramine, wetted or Cyclonite, wetted or Hexogen, wetted or RDX, wetted with not less than 15 percent water by mass1.1DUN0072II1.1DNone62NoneForbiddenForbidden10
    Cymenes3UN2046III3B1, IB3, T2, TP115020324260 L220 LA
    Dangerous Goods in Machinery or Dangerous Goods in Apparatus9UN3363136None222NoneNo limitNo limitA
    Start Printed Page 33361
    Decaborane4.1UN1868II4.1, 6.1A19, A20, IB6, IP2None212NoneForbidden50 kgA
    Decahydronaphthalene3UN1147III3B1, IB3, T2, TP115020324260 L220 LA
    n-Decane3UN2247III3B1, IB3, T2, TP115020324260 L220 LA
    Deflagrating metal salts of aromatic nitroderivatives, n.o.s.1.3CUN0132II1.3CNone62NoneForbiddenForbidden105E
    Delay electric igniter, see Igniters
    Depth charges, see Charges, depth
    Detonating relays, see Detonators, etc
    Detonator assemblies, non-electric for blasting1.1BUN0360II1.1BNone62NoneForbiddenForbidden11
    Detonator assemblies, non-electric, for blasting1.4BUN0361II1.4B10363(f), 63(g)62NoneForbidden75 kg06
    Detonator, assemblies, non-electric for blasting1.4SUN0500II1.4S63(f), 63(g)62None25 kg100 kg05
    Detonators, electric, for blasting1.1BUN0030II1.1B63(f), 63(g)62NoneForbiddenForbidden11
    Detonators, electric, for blasting1.4BUN0255II1.4B10363(f), 63(g)62NoneForbidden75 kg06
    Detonators, electric for blasting1.4SUN0456II1.4S63(f), 63(g)62None25 kg100 kg05
    Detonators for ammunition1.1BUN0073II1.1BNone62NoneForbiddenForbidden11
    Detonators for ammunition1.2BUN0364II1.2BNone62NoneForbiddenForbidden11
    Detonators for ammunition1.4BUN0365II1.4B103None62NoneForbidden75 kg06
    Detonators for ammunition1.4SUN0366II1.4SNone62None25 kg100 kg05
    Detonators, non-electric, for blasting1.1BUN0029II1.1BNone62NoneForbiddenForbidden11
    Detonators, non-electric, for blasting1.4BUN0267II1.4B10363(f), 63(g)62NoneForbidden75 kg06
    Detonators, non-electric, for blasting1.4SUN0455II1.4S63(f), 63(g)62None25 kg100 kg5
    Deuterium, compressed2.1UN19572.1306302NoneForbidden150 kgE40
    Devices, small, hydrocarbon gas powered or Hydrocarbon gas refills for small devices with release device2.1UN31502.1306304NoneForbidden150 kgB40
    Di-n-amylamine3UN2841III3, 6.1B1, IB3, T4, TP115020324260 L220 LA
    Di-n-butyl peroxydicarbonate, with more than 52 percent in solutionForbidden
    Di-n-butylamine8UN2248II8, 3IB2, T7, TP2None2022431 L30 LA
    2,2-Di-(tert-butylperoxy) butane, with more than 55 percent in solutionForbidden
    Di-(tert-butylperoxy) phthalate, with more than 55 percent in solutionForbidden
    2,2-Di-(4,4-di-tert-butylperoxycyclohexyl) propane, with more than 42 percent with inert solidForbidden
    Di-2,4-dichlorobenzoyl peroxide, with more than 75 percent with waterForbidden
    1,2-Di-(dimethylamino)ethane3UN2372II3IB2, T4, TP11502022425 L60 LB
    Di-2-ethylhexyl phosphoric acid, see Diisooctyl acid phosphate
    Di-(1-hydroxytetrazole) (dry)Forbidden
    Di-(1-naphthoyl) peroxideForbidden
    a,a'-Di-(nitroxy) methyletherForbidden
    Di-(beta-nitroxyethyl) ammonium nitrateForbidden
    Diacetone alcohol3UN1148II3IB2, T4, TP11502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Diacetone alcohol peroxides, with more than 57 percent in solution with more than 9 percent hydrogen peroxide, less than 26 percent diacetone alcohol and less than 9 percent water; total active oxygen content more than 9 percent by massForbidden
    Diacetyl, see Butanedione
    Diacetyl peroxide, solid, or with more than 25 percent in solutionForbidden
    Diallylamine3UN2359II3, 6.1, 8IB2, T7, TP1None2022431 L5 LB21, 40, 100
    Diallylether3UN2360II3, 6.1IB2, N12, T7, TP1, TP13None2022431 L60 LE40
    4,4'-Diaminodiphenyl methane6.1UN2651III6.1IB8, IP3, T4, TP1153213240100 kg200 kgA
    p-DiazidobenzeneForbidden
    1,2-DiazidoethaneForbidden
    1,1'-DiazoaminonaphthaleneForbidden
    Diazoaminotetrazole (dry)Forbidden
    Diazodinitrophenol (dry)Forbidden
    Start Printed Page 33362
    Diazodinitrophenol, wetted with not less than 40 percent water or mixture of alcohol and water, by mass1.1AUN0074II1.1A111, 117None62NoneForbiddenForbidden12
    DiazodiphenylmethaneForbidden
    Diazonium nitrates (dry)Forbidden
    Diazonium perchlorates (dry)Forbidden
    1,3-DiazopropaneForbidden
    Dibenzyl peroxydicarbonate, with more than 87 percent with waterForbidden
    Dibenzyldichlorosilane8UN2434II8B2, IB2, T7, TP2, TP131542022421 L30 LC40
    Diborane, compressed2.3UN19112.3, 2.11None302NoneForbiddenForbiddenD40, 57
    DDiborane mixtures2.1NA19112.15None302245ForbiddenForbiddenD40, 57
    DibromoacetyleneForbidden
    1,2-Dibromobutan-3-one6.1UN2648II6.1IB2None2022435 L60 LB40
    Dibromochloropropane6.1UN2872III6.1IB3, T4, TP115320324160 L220 LA
    ADibromodifluoromethane , R12B29UN1941IIINoneT11, TP2155203241100 L220 LA25
    1,2-Dibromoethane, see Ethylene dibromide
    Dibromomethane6.1UN2664III6.1IB3, T4, TP115320324160 L220 LA
    Dibutyl ethers3UN1149III3B1, IB3, T2, TP115020324260 L220 LA
    Dibutylaminoethanol6.1UN2873III6.1IB3, T4, TP115320324160 L220 LA
    N,N'-Dichlorazodicarbonamidine (salts of) (dry)Forbidden
    1,1-Dichloro-1-nitroethane6.1UN2650II6.1IB2, T7, TP2None2022435 L60 LA12, 40
    D3,5-Dichloro-2,4,6-trifluoropyridine6.1NA9264I6.12, B9, B14, B32, B74, T20, TP4, TP12, TP13, TP38, TP45None227244ForbiddenForbiddenA40
    Dichloroacetic acid8UN1764II8A3, A6, A7, B2, IB2, N34, T8, TP2, TP121542022421 L30 LA
    1,3-Dichloroacetone6.1UN2649II6.1IB8, IP2, IP4None21224225 kg100 kgB12, 40
    Dichloroacetyl chloride8UN1765II8A3, A6, A7, B2, B6, IB2, N34, T7, TP21542022421 L30 LD40
    DichloroacetyleneForbidden
    +Dichloroanilines, liquid6.1UN1590II6.1IB2, T7, TP2None2022435 L60 LA40
    +Dichloroanilines, solid6.1UN1590II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA40
    +o-Dichlorobenzene6.1UN1591III6.1IB3, T4, TP115320324160 L220 LA
    2,2'-Dichlorodiethyl ether6.1UN1916II6.1, 3IB2, N33, N34, T7, TP2None2022435 L60 LA
    Dichlorodifluoromethane and difluoroethane azeotropic mixture or Refrigerant gas R 500 with approximately 74 percent dichlorodifluoromethane2.2UN26022.2T50306304314, 31575 kg150 kgA
    Dichlorodifluoromethane or Refrigerant gas R 122.2UN10282.2T50306304314, 31575 kg150 kgA
    Dichlorodimethyl ether, symmetrical6.1UN2249I6.1None201243ForbiddenForbiddenD40
    1,1-Dichloroethane3UN2362II3IB2, T4, TP11502022425 L60 LB40
    1,2-Dichloroethane, see Ethylene dichloride
    Dichloroethyl sulfideForbidden
    1,2-Dichloroethylene3UN1150II3IB2, T7, TP21502022425 L60 LB
    Dichlorofluoromethane or Refrigerant gas R212.2UN10292.2T50306304314, 31575 kg150 kgA
    Dichloroisocyanuric acid, dry or Dichloroisocyanuric acid salts5.1UN2465II5.128, IB8, IP41522122405 kg25 kgA13
    Dichloroisopropyl ether6.1UN2490II6.1IB2, T7, TP2None2022435 L60 LB
    Dichloromethane6.1UN1593III6.1IB3, IP8, N36, T7, TP215320324160 L220 LA
    Dichloropentanes3UN1152III3B1, IB3, T2, TP115020324260 L220 LA
    Dichlorophenyl isocyanates6.1UN2250II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgB25, 40, 48
    Dichlorophenyltrichlorosilane8UN1766II8A7, B2, B6, IB2, N34, T7, TP2, TP13None202242Forbidden30 LC40
    1,2-Dichloropropane3UN1279II3IB2, N36, T4, TP11502022425 L60 LB
    1,3-Dichloropropanol-26.1UN2750II6.1IB2, T7, TP2None2022435 L60 LA12, 40
    Dichloropropene and propylene dichloride mixture, see 1,2- Dichloropropane
    Dichloropropenes3UN2047II3IB2, T4, TP11502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Dichlorosilane2.3UN21892.3, 2.1, 82, B9, B14None304314, 315ForbiddenForbiddenD17, 40
    1,2-Dichloro-1,1,2,2- tetrafluoroethane or Refrigerant gas R 1142.2UN19582.2T50306304314, 31575 kg150 kgA
    DichlorovinylchloroarsineForbidden
    Start Printed Page 33363
    Dicycloheptadiene, see Bicyclo [2,2,1] hepta-2,5-diene, stabilized
    Dicyclohexylamine8UN2565III8IB3, T4, TP11542032415 L60 LA
    Dicyclohexylammonium nitrite4.1UN2687III4.1IB8, IP315121324025 kg100 kgA48
    Dicyclopentadiene3UN2048III3B1, IB3, T2, TP115020324260 L220 LA
    Didymium nitrate5.1UN1465III5.1A1, IB8, IP315221324025 kg100 kgA
    DDiesel fuel3NA1993IIINoneB1, IB3, T4, TP1, TP2915020324260 L220 LA
    IDiesel fuel3UN1202III3B1, IB3, T2, TP115020324260 L220 LA
    Diethanol nitrosamine dinitrate (dry)Forbidden
    Diethoxymethane3UN2373II3IB2, T4, TP11502022425 L60 LE
    3,3-Diethoxypropene3UN2374II3IB2, T4, TP11502022425 L60 LB
    Diethyl carbonate3UN2366III3B1, IB3, T2, TP115020324260 L220 LA
    Diethyl cellosolve, see Ethylene glycol diethyl ether
    Diethyl ether or Ethyl ether3UN1155I3T11, TP21502012431 L30 LE40
    Diethyl ketone3UN1156II3IB2, T4, TP11502022425 L60 LB
    Diethyl peroxydicarbonate, with more than 27 percent in solutionForbidden
    Diethyl sulfate6.1UN1594II6.1IB2, T7, TP2None2022435 L60 LC
    Diethyl sulfide3UN2375II3IB2, T7, TP1, TP13None2022435 L60 LE
    Diethylamine3UN1154II3, 8IB2, N34, T7, TP1None2022431 L5 LE40
    2-Diethylaminoethanol8UN2686II8, 3B2, IB2, T7, TP2None2022431 L30 LA
    Diethylaminopropylamine3UN2684III3, 8B1, IB3, T4, TP11502032425 L60 LA
    +N, N-Diethylaniline6.1UN2432III6.1IB3, T4, TP115320324160 L220 LA
    Diethylbenzene3UN2049III3B1, IB3, T2, TP115020324260 L220 LA
    Diethyldichlorosilane8UN1767II8, 3A7, B6, IB2, N34, T7, TP2, TP13None202243Forbidden30 LC40
    Diethylene glycol dinitrateForbidden
    Diethyleneglycol dinitrate, desensitized with not less than 25 percent non-volatile water-insoluble phlegmatizer, by mass1.1DUN0075II1.1DNone62NoneForbiddenForbidden1321E
    Diethylenetriamine8UN2079II8B2, IB2, T7, TP21542022421 L30 LA40
    N,N-Diethylethylenediamine8UN2685II8, 3IB2, T7, TP2None2022431 L30 LA
    Diethylgold bromideForbidden
    Diethylthiophosphoryl chloride8UN2751II8B2, IB2,T7, TP21542022421 L39 LA40
    Diethylzinc4.2UN1366I4.2, 4.3B11, T21, TP2, TP7None181244ForbiddenForbiddenD18
    Difluorochloroethanes, see 1-Chloro-1,1-difluoroethanes
    1,1-Difluoroethane or Refrigerant gas R 152a2.1UN10302.1T50306304314, 315Forbidden150 kgB40
    1,1-Difluoroethylene or Refrigerant gas R 1132a2.1UN19592.1306304NoneForbidden150 kgE40
    Difluoromethane or Refrigerant gas R 322.1UN32522.1T50306302314, 315Forbidden150 kgD40
    Difluorophosphoric acid, anhydrous8UN1768II8A6, A7, B2, IB2, N5, N34, T8, TP2, TP12None2022421 L30 LA40
    2,3-Dihydropyran3UN2376II3IB2, T4, TP11502022425 L60 LB
    1,8-Dihydroxy-2,4,5,7-tetranitroanthraquinone (chrysamminic acid)Forbidden
    DiiodoacetyleneForbidden
    Diisobutyl ketone3UN1157III3B1, IB3, T2, TP115020324260 L220 LA
    Diisobutylamine3UN2361III3, 8B1, IB3, T4, TP11502032425 L60 LA
    Diisobutylene, isomeric compounds3UN2050II3IB2, T4, TP11502022425 L60 LB
    Diisooctyl acid phosphate8UN1902III8IB3, T4, TP11542032415 L60 LA
    Diisopropyl ether3UN1159II3IB2, T4, TP11502022425 L60 LE40
    Diisopropylamine3UN1158II3, 8IB2, T7, TP1None2022431 L5 LB
    Diisopropylbenzene hydroperoxide, with more than 72 percent in solutionForbidden
    Diketene, stabilized6.1UN2521I6.1, 32, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40, 49
    1,2-Dimethoxyethane3UN2252II3IB2, T4, TP11502022425 L60 LB
    1,1-Dimethoxyethane3UN2377II3IB2, T7, TP11502022425 L60 LB
    Dimethyl carbonate3UN1161II3IB2, T4, TP11502022425 L60 LB
    Dimethyl chlorothiophosphate, see Dimethyl thiophosphoryl chloride
    2,5-Dimethyl-2,5-dihydroperoxy hexane, with more than 82 percent with waterForbidden
    Dimethyl disulfide3UN2381II3IB2, T4, TP11502022425 L60 LB40
    Dimethyl ether2.1UN10332.1T50306304314, 315Forbidden150 kgB40
    Dimethyl-N-propylamine3UN2266II3, 8IB2, T7, TP2, TP13None2022431 L5 LB40
    Start Printed Page 33364
    Dimethyl sulfate6.1UN1595I6.1, 82, B9, B14, B32, B74, B77, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Dimethyl sulfide3UN1164II3IB1, IP8, T7, TP2None2022425 L60 LE40
    Dimethyl thiophosphoryl chloride6.1UN2267II6.1, 8IB2, T7, TP2None2022431 L30 LB25
    Dimethylamine, anhydrous2.1UN10322.1T50None304314, 315Forbidden150 kgD40
    Dimethylamine solution3UN1160II3, 8IB2, T7, TP1None2022431 L5 LB
    2-Dimethylaminoacetonitrile3UN2378II3, 6.1IB2, T7, TP1None2022431 L60 LA26, 40
    2-Dimethylaminoethanol8UN2051II8, 3B2, IB2, T7, TP21542022431 L30 LA
    2-Dimethylaminoethyl acrylate6.1UN3302II6.1IB2, T7, TP2None2022435 L60 LD25
    2-Dimethylaminoethyl methacrylate6.1UN2522II6.1IB2, T7, TP2None2022435 L60 LB40
    N,N-Dimethylaniline6.1UN2253II6.1IB1, T7, TP2None2022435 L60 LA
    2,3-Dimethylbutane3UN2457II3IB2, T7, TP11502022425 L60 LE
    1,3-Dimethylbutylamine3UN2379II3, 8IB2, T7, TP1None2022431 L5 LB
    Dimethylcarbamoyl chloride8UN2262II8B2, IB2, T7, TP21542022421 L30 LA40
    Dimethylcyclohexanes3UN2263II3IB2, T4, TP11502022425 L60 LB
    Dimethylcyclohexylamine8UN2264II8, 3B2, IB2, T7, TP21542022431 L30 LA40
    Dimethyldichlorosilane3UN1162II3, 8B77, IB2, T7, TP2, TP13None202243ForbiddenForbiddenB40
    Dimethyldiethoxysilane3UN2380II3IB2, T4, TP11502022425 L60 LB
    Dimethyldioxanes3UN2707II3IB2, T4, TP11502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    N,N-Dimethylformamide3UN2265III3B1, IB3, T2, TP215020324260 L220 LA
    Dimethylhexane dihydroperoxide (dry)Forbidden
    Dimethylhydrazine, symmetrical6.1UN2382I6.1, 32, A7, B9, B14, B32, B74, B77, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Dimethylhydrazine, unsymmetrical6.1UN1163I6.1, 3, 82, B7, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD21, 38, 40, 100
    2,2-Dimethylpropane2.1UN20442.1306304314, 315Forbidden150 kgE40
    Dimethylzinc4.2UN1370I4.2, 4.3B11, B16, T21, TP2, TP7None181244ForbiddenForbiddenD18
    Dinitro-o-cresol, solid6.1UN1598II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA
    Dinitro-o-cresol, solution6.1UN1598II6.1IB2, IP2, IP4, T7, TP2None2022435 L60 LA
    1,3-Dinitro-5,5-dimethyl hydantoinForbidden
    Dinitro-7,8-dimethylglycoluril (dry)Forbidden
    1,3-Dinitro-4,5-dinitrosobenzeneForbidden
    1,4-Dinitro-1,1,4,4-tetramethylolbutanetetranitrate (dry)Forbidden
    2,4-Dinitro-1,3,5-trimethylbenzeneForbidden
    Dinitroanilines6.1UN1596II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA91
    Dinitrobenzenes, liquid6.1UN1597II6.111, IB2, T7, TP2None2022435 L60 LA91
    Dinitrobenzenes, solid6.1UN1597II6.111, IB8, IP2, IP4None21224225 kg100 kgA91
    Dinitrochlorobenzene, see Chlorodinitrobenzene
    1,2-DinitroethaneForbidden
    1,1-Dinitroethane (dry)Forbidden
    Dinitrogen tetroxide2.3UN10672.3, 5.1, 81, B7, B14, B45, B46, B61, B66, B67, B77, T50, TP21None336314ForbiddenForbiddenD40, 89, 90
    Dinitroglycoluril or Dingu1.1DUN0489II1.1DNone62NoneForbiddenForbidden10
    DinitromethaneForbidden
    Dinitrophenol, dry or wetted with less than 15 percent water, by mass1.1DUN0076II1.1D, 6.1None62NoneForbiddenForbidden105E
    Dinitrophenol solutions6.1UN1599II6.1IB2, T7, TP2None2022435 L60 LA36
    III6.1IB3, T4, TP115320324160 L220 LA36
    Dinitrophenol, wetted with not less than 15 percent water, by mass4.1UN1320I4.1, 6.123, A8, A19, A20, N41None211None1 kg15 kgE28, 36
    Dinitrophenolates alkali metals, dry or wetted with less than 15 percent water, by mass1.3CUN0077II1.3C, 6.1None62NoneForbiddenForbidden105E
    Dinitrophenolates, wetted with not less than 15 percent water, by mass4.1UN1321I4.1, 6.123, A8, A19, A20, N41None211None1 kg15 kgE28, 36
    Dinitropropylene glycolForbidden
    Dinitroresorcinol, dry or wetted with less than 15 percent water, by mass1.1DUN0078II1.1DNone62NoneForbiddenForbidden105E
    2,4-Dinitroresorcinol (heavy metal salts of) (dry)Forbidden
    4,6-Dinitroresorcinol (heavy metal salts of) (dry)Forbidden
    Dinitroresorcinol, wetted with not less than 15 percent water, by mass4.1UN1322I4.123, A8, A19, A20, N41None211None1 kg15 kgE28, 36
    Start Printed Page 33365
    3,5-Dinitrosalicylic acid (lead salt) (dry)Forbidden
    Dinitrosobenzene1.3CUN0406II1.3CNone62NoneForbiddenForbidden10
    Dinitrosobenzylamidine and salts of (dry)Forbidden
    2,2-DinitrostilbeneForbidden
    Dinitrotoluenes, liquid6.1UN2038II6.1IB2, T7, TP2None2022435 L60 LA
    Dinitrotoluenes, molten6.1UN1600II6.1T7, TP3None202243ForbiddenForbiddenC
    Dinitrotoluenes, solid6.1UN2038II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA
    1,9-Dinitroxy pentamethylene-2,4, 6,8-tetramine (dry)Forbidden
    Dioxane3UN1165II3IB2, T4, TP11502022425 L60 LB
    Dioxolane3UN1166II3IB2, T4, TP11502022425 L60 LB40
    Dipentene3UN2052III3B1, IB3, T2, TP115020324260 L220 LA
    Diphenylamine chloroarsine6.1UN1698I6.1None201NoneForbiddenForbiddenD40
    Diphenylchloroarsine, liquid6.1UN1699I6.1A8, B14, B32, N33, N34, T14, TP2, TP13, TP27None201243Forbidden30 LD40
    Diphenylchloroarsine, solid6.1UN1699I6.1A8, B14, B32, IB7, IP1, N33, N34None211242Forbidden15 kgD40
    Diphenyldichlorosilane8UN1769II8A7, B2, IB2, N34, T7, TP2, TP13None202242Forbidden30 LC40
    Diphenylmethyl bromide8UN1770II8IB8, IP2, IP415421224015 kg50 kgD40
    Dipicryl sulfide, dry or wetted with less than 10 percent water, by mass1.1DUN0401II1.1DNone62NoneForbiddenForbidden10
    Dipicryl sulfide, wetted with not less than 10 percent water, by mass4.1UN2852I4.1A2, N41None211NoneForbidden0.5 kgD28
    Dipicrylamine, see Hexanitrodiphenylamine
    Dipropionyl peroxide, with more than 28 percent in solutionForbidden
    Di-n-propyl ether3UN2384II3IB2, T4, TP11502022425 L60 LB
    Dipropyl ketone3UN2710III3B1, IB3, T2, TP115020324260 L220 LA
    Dipropylamine3UN2383II3, 8IB2, T7, TP1None2022431 L5 LB
    GDisinfectant, liquid, corrosive, n.o.s.8UN1903I8A7, B10, T14, TP2, TP27None2012430.5 L2.5 LB
    GDisinfectants, liquid, corrosive n.o.s.8UN1903II8B2, IB2, T7, TP21542022421 L30 LB
    III8IB3, T4, TP11542032415 L60 LA
    GDisinfectants, liquid, toxic, n.o.s.6.1UN3142I6.1A4, T14, TP2, TP27None2012431 L30 LA40
    II6.1IB2, T11, TP2, TP27None2022435 L60 LA40
    III6.1IB3, T7, TP1, TP2815320324160 L220 LA40
    GDisinfectants, solid, toxic, n.o.s.6.1UN1601II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Disodium trioxosilicate8UN3253III8IB8, IP315421324025 kg100 kgA
    GDispersant gases, n.o.s. see Refrigerant gases, n.o.s.
    Divinyl ether, stabilized3UN1167I3T11, TP2None2012431 L30 LE40
    Dodecyltrichlorosilane8UN1771II8A7, B2, B6, IB2, N34, T7, TP2, TP13None202242Forbidden30 LC40
    Dry ice, see Carbon dioxide, solid
    GDyes, liquid, corrosive, n.o.s. or Dye intermediates, liquid, corrosive, n.o.s.8UN2801I811, B10, T14, TP2, TP27None2012430.5 L2.5 LA
    II811, B2, IB2, T11, TP2, TP271542022421 L30 LA
    III811, IB3, T7, TP1, TP281542032415 L60 LA
    GDyes, liquid, toxic, n.o.s. or Dye intermediates, liquid, toxic, n.o.s.6.1UN1602II6.1IB2None2022435 L60 LA
    III6.1IB315320324160 L220 LA
    GDyes, solid, corrosive, n.o.s. or Dye intermediates, solid, corrosive, n.o.s.8UN3147I8IB7, IP1None2112421 kg25 kgA
    II8IB8, IP2, IP415421224015 kg50 kgA
    III8IB8, IP315421324025 kg100 kgA
    GDyes, solid, toxic, n.o.s. or Dye intermediates, solid, toxic, n.o.s.6.1UN3143I6.1A5, IB7, IP1, T14, TP2, TP27None2112425 kg50 kgA
    II6.1IB8, IP2, IP4None21224225 kg100 kgA
    III6.1IB8, IP3153213240100 kg200 kgA
    Dynamite, see Explosive, blasting, type A
    Electrolyte (acid or alkali) for batteries, see Battery fluid, acid or Battery fluid, alkali
    Elevated temperature liquid, flammable, n.o.s. , with flash point above 37.8 C, at or above its flash point3UN3256III3IB1, T3, TP3, TP29NoneNone247ForbiddenForbiddenA
    Start Printed Page 33366
    Elevated temperature liquid, n.o.s., at or above 100 C and below its flash point (including molten metals, molten salts, etc.)9UN3257III9IB1, T3, TP3, TP29NoneNone247ForbiddenForbiddenA85
    Elevated temperature solid, n.o.s., at or above 240 C, see § 173.247(h)(4)9UN3258III9247(h) (4)None247ForbiddenForbiddenA85
    Engines, internal combustion, flammable gas powered9UN31669135220220220ForbiddenNo limitA
    Engines, internal combustion, flammable liquid powered9UN31669135220220220No limitNo limitA
    GEnvironmentally hazardous substances, liquid, n.o.s.9UN3082III98, IB3, T4, TP1, TP29155203241No limitNo limitA
    GEnvironmentally hazardous substances, solid, n.o.s.9UN3077III98, B54, IB8, N20155213240No limitNo limitA
    Epibromohydrin6.1UN2558I6.1, 3T14, TP2, TP13None201243ForbiddenForbiddenD40
    +Epichlorohydrin6.1UN2023II6.1, 3IB2, T7, TP2, TP13None2022435 L60 LA40
    1,2-Epoxy-3-ethoxypropane3UN2752III3B1, IB3, T2, TP115020324260 L220 LA
    Esters, n.o.s.3UN3272II3IB2, T7, TP1, TP8, TP281502022425 L60 LB
    III3B1, IB3, T4, TP1, TP2915020324260 L220 LA
    Etching acid, liquid, n.o.s., see Hydrofluoric acid, solution etc
    Ethane2.1UN10352.1306304302Forbidden150 kgE40
    DEthane-Propane mixture, refrigerated liquid2.1NA19612.1T75, TP5None316314, 315ForbiddenForbiddenD40
    Ethane, refrigerated liquid2.1UN19612.1T75, TP5NoneNone315ForbiddenForbiddenD40
    Ethanol amine dinitrateForbidden
    Ethanol or Ethyl alcohol or Ethanol solutions or Ethyl alcohol solutions3UN1170II324, IB2, T4, TP11502022425 L60 LA
    III324, B1, IB3, T2, TP115020324260 L220 LA
    Ethanolamine or Ethanolamine solutions8UN2491III8IB3, T4, TP11542032415 L60 LA
    Ether, see Diethyl ether
    Ethers, n.o.s.3UN3271II3IB2, T7, TP1, TP8, TP281502022425 L60 LB
    III3B1, IB3, T4, TP1, TP2915020324260 L220 LA
    Ethyl acetate3UN1173II3IB2, T4, TP11502022425 L60 LB
    Ethyl acrylate, stabilized3UN1917II3IB2, T4, TP1, TP131502022425 L60 LB40
    Ethyl alcohol, see Ethanol
    Ethyl aldehyde, see Acetaldehyde
    Ethyl amyl ketone3UN2271III3B1, IB3, T2, TP115020324260 L220 LA
    N-Ethyl-N-benzylaniline6.1UN2274III6.1IB3, T4, TP115320324160 L220 LA
    Ethyl borate3UN1176II3IB2, T4, TP11502022425 L60 LB
    Ethyl bromide6.1UN1891II6.1IB2, IP8, T7, TP2, TP13None2022435 L60 LB40, 85
    Ethyl bromoacetate6.1UN1603II6.1, 3IB2, T7, TP2None202243ForbiddenForbiddenD40
    Ethyl butyl ether3UN1179II3B1, IB2, T4, TP11502022425 L60 LB
    Ethyl butyrate3UN1180III3B1, IB3, T2, TP115020324260 L220 LA
    Ethyl chloride2.1UN10372.1B77, T50None322314, 315Forbidden150 kgB40
    Ethyl chloroacetate6.1UN1181II6.1, 3IB2, T7, TP2None2022435 L60 LA
    Ethyl chloroformate6.1UN1182I6.1, 3, 82, A3, A6, A7, B9, B14, B32, B74, N34, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD21, 40, 100
    Ethyl 2-chloropropionate3UN2935III3B1, IB3, T2, TP115020324260 L220 LA
    +Ethyl chlorothioformate8UN2826II8, 6.1, 32, B9, B14, B32, B74, T20, TP2, TP38, TP45None227244ForbiddenForbiddenA40
    Ethyl crotonate3UN1862II3IB2, T4, TP21502022425 L60 LB
    Ethyl ether, see Diethyl ether
    Ethyl fluoride or Refrigerant gas R1612.1UN24532.1306304314, 315Forbidden150 kgE40
    Ethyl formate3UN1190II3IB2, T4, TP11502022425 L60 LE
    Ethyl hydroperoxideForbidden
    Ethyl isobutyrate3UN2385II3IB2, T4, TP11502022425 L60 LB
    +Ethyl isocyanate3UN2481I3, 6.11, A7, B9, B14, B30, B72, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenD40
    Ethyl lactate3UN1192III3B1, IB3, T2, TP115020324260 L220 LA
    Ethyl mercaptan3UN2363I3T11, TP2, TP13None201243Forbidden30 LE95, 102
    Ethyl methacrylate3UN2277II3IB2, T4, TP11502022425 L60 LB
    Ethyl methyl ether2.1UN10392.1None201314, 315Forbidden150 kgB40
    Ethyl methyl ketone or Methyl ethyl ketone3UN1193II3IB2, T4, TP11502022425 L60 LB
    Ethyl nitrite solutions3UN1194I3, 6.1None201NoneForbiddenForbiddenE40, 105
    Ethyl orthoformate3UN2524III3B1, IB3, T2, TP115020324260 L220 LA
    Ethyl oxalate6.1UN2525III6.1IB3, T4, TP115320324160 L220 LA
    Ethyl perchlorateForbidden
    Start Printed Page 33367
    DEthyl phosphonothioic dichloride, anhydrous6.1NA2927I6.1, 82, B9, B14, B32, B74, T20, TP4, TP12, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    DEthyl phosphonous dichloride, anhydrous pyrophoric liquid6.1NA2845I6.1, 4.22, B9, B14, B32, B74, T20, TP4, TP12, TP13, TP38, TP45None227244ForbiddenForbiddenD18
    DEthyl phosphorodichloridate6.1NA2927I6.1, 82, B9, B14, B32, B74, T20, TP4, TP12, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Ethyl propionate3UN1195II3IB2, T4, TP11502022425 L60 LB
    Ethyl propyl ether3UN2615II3IB2, T4, TP11502022425 L60 LE
    Ethyl silicate, see Tetraethyl silicate
    Ethylacetylene, stabilized2.1UN24522.1None304314, 315Forbidden150 kgB40
    Ethylamine2.1UN10362.1B77, T50None321314, 315Forbidden150 kgD40
    Ethylamine, aqueous solution with not less than 50 percent but not more than 70 percent ethylamine3UN2270II3, 8IB2, T7, TP1None2022431 L5 LB40
    N-Ethylaniline6.1UN2272III6.1IB3, T4, TP115320324160 L220 LA
    2-Ethylaniline6.1UN2273III6.1IB3, T4, TP115320324160 L220 LA
    Ethylbenzene3UN1175II3IB2, T4, TP11502022425 L60 LB
    N-Ethylbenzyltoluidines liquid6.1UN2753III6.1IB3, T7, TP115320324160 L220 LA
    N-Ethylbenzyltoluidines solid6.1UN2753III6.1IB8, IP3, T7, TP1153213240100 kg200 kgA
    2-Ethylbutanol3UN2275III3B1, IB3, T2, TP115020324260 L220 LA
    Ethylbutyl acetate3UN1177III3B1, IB3, T2, TP115020324260 L220 LA
    2-Ethylbutyraldehyde3UN1178II3B1, IB2, T4, TP11502022425 L60 LB
    Ethyldichloroarsine6.1UN1892I6.12, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Ethyldichlorosilane4.3UN1183I4.3, 8, 3A2, A3, A7, N34, T10, TP2, TP7, TP13None201244Forbidden1 LD21, 28, 40, 49, 100
    Ethylene, acetylene and propylene in mixture, refrigerated liquid with at least 71.5 percent ethylene with not more than 22.5 percent acetylene and not more than 6 percent propylene2.1UN31382.1T75, TP5None304314, 315ForbiddenForbiddenD40
    Ethylene chlorohydrin6.1UN1135I6.1, 32, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Ethylene, compressed2.1UN19622.1306304302Forbidden150 kgE40
    Ethylene diamine diperchlorateForbidden
    Ethylene dibromide6.1UN1605I6.12, B9, B14, B32, B74, B77, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Ethylene dibromide and methyl bromide liquid mixtures, see Methyl bromide and ethylene dibromide, liquid mixtures
    Ethylene dichloride3UN1184II3, 6.1IB2, T7, TP1None2022431 L60 LB40
    Ethylene glycol diethyl ether3UN1153III3B1, IB3, T2, TP115020324260 L220 LA
    Ethylene glycol dinitrateForbidden
    Ethylene glycol monoethyl ether3UN1171III3B1, IB3, T2, TP115020324260 L220 LA
    Ethylene glycol monoethyl ether acetate3UN1172III3B1, IB3, T2, TP115020324260 L220 LA
    Ethylene glycol monomethyl ether3UN1188III3B1, IB3, T2, TP115020324260 L220 LA
    Ethylene glycol monomethyl ether acetate3UN1189III3B1, IB3, T2, TP115020324260 L220 LA
    Ethylene oxide and carbon dioxide mixture with more than 87 percent ethylene oxide2.3UN33002.3, 2.14None304314, 315ForbiddenForbiddenD40
    Ethylene oxide and carbon dioxide mixtures with more than 9 percent but not more than 87 percent ethylene oxide2.1UN10412.1T50306304314, 315Forbidden25 kgB40
    Ethylene oxide and carbon dioxide mixtures with not more than 9 percent ethylene oxide2.2UN19522.2306304314, 31575 kg150 kgA
    Ethylene oxide and chlorotetrafluoroethane mixture with not more than 8.8 percent ethylene oxide2.2UN32972.2T50306304314, 31575 kg150 kgA
    Ethylene oxide and dichlorodifluoromethane mixture, with not more than 12.5 percent ethylene oxide2.2UN30702.2T50306304314, 31575 kg150 kgA
    Ethylene oxide and pentafluoroethane mixture with not more than 7.9 percent ethylene oxide2.2UN32982.2T50306304314, 31575 kg150 kgA
    Start Printed Page 33368
    Ethylene oxide and propylene oxide mixtures , with not more than 30 percent ethylene oxide3UN2983I3, 6.15, A11, N4, N34, T14, TP2, TP7, TP13None201243Forbidden30 LE40
    Ethylene oxide and tetrafluoroethane mixture with not more than 5.6 percent ethylene oxide2.2UN32992.2T50306304314, 31575 kg150 kgA
    Ethylene oxide or Ethylene oxide with nitrogen up to a total pressure of 1MPa (10 bar) at 50 degrees C2.3UN10402.3, 2.14, T50, TP20None323323Forbidden25 kgD40
    Ethylene, refrigerated liquid (cryogenic liquid)2.1UN10382.1T75, TP5None316318, 319ForbiddenForbiddenD40
    Ethylenediamine8UN1604II8, 3IB2, T7, TP21542022431 L30 LA40
    Ethyleneimine, stabilized6.1UN1185I6.1, 31, B9, B14, B30, B72, B77, N25, N32, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenD40
    Ethylhexaldehyde, see Octyl aldehydes etc
    2-Ethylhexyl chloroformate6.1UN2748II6.1, 8IB2, T7, TP2, TP13None2022431 L30 LA12, 13, 21, 25, 40, 100
    2-Ethylhexylamine3UN2276III3, 8B1, IB3, T4, TP11502032425 L60 LA40
    Ethylphenyldichlorosilane8UN2435II8A7, B2, IB2, N34, T7, TP2, TP13None202242Forbidden30 LC
    1-Ethylpiperidine3UN2386II3, 8IB2, T7, TP1None2022431 L5 LB
    N-Ethyltoluidines6.1UN2754II6.1IB2, T7, TP2None2022435 L60 LA
    Ethyltrichlorosilane3UN1196II3, 8A7, IB1, N34, T7, TP2, TP13None2022431 L5 LB40
    Etiologic agent, see Infectious substances, etc
    Explosive articles, see Articles, explosive , n.o.s. etc
    Explosive, blasting, type A1.1DUN0081II1.1DNone62NoneForbiddenForbidden1021E
    Explosive, blasting, type B1.1DUN0082II1.1DNone62NoneForbiddenForbidden10
    Explosive, blasting, type B or Agent blasting, Type B1.5DUN0331II1.5D105, 106None62NoneForbiddenForbidden10
    Explosive, blasting, type C1.1DUN0083II1.1D123None62NoneForbiddenForbidden1022E
    Explosive, blasting, type D1.1DUN0084II1.1DNone62NoneForbiddenForbidden10
    Explosive, blasting, type E1.1DUN0241II1.1DNone62NoneForbiddenForbidden1019E
    Explosive, blasting, type E or Agent blasting, Type E1.5DUN0332II1.5D105, 106None62NoneForbiddenForbidden10
    Explosive, forbidden. See § 173.54Forbidden
    Explosive substances, see Substances, explosive, n.o.s. etc
    Explosives, slurry, see Explosive, blasting, type E
    Explosives, water gels, see Explosive, blasting, type E
    Extracts, aromatic, liquid3UN1169II3IB2, T4, TP1, TP81502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Extracts, flavoring, liquid3UN1197II3IB2, T4, TP1, TP81502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Fabric with animal or vegetable oil, see Fibers or fabrics, etc
    Ferric arsenate6.1UN1606II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Ferric arsenite6.1UN1607II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Ferric chloride, anhydrous8UN1773III8IB8, IP315421324025 kg100 kgA
    Ferric chloride, solution8UN2582III8B15, IB3, T4, TP11542032415 L60 LA
    Ferric nitrate5.1UN1466III5.1A1, A29, IB8, IP315221324025 kg100 kgA
    Ferrocerium4.1UN1323II4.159, A19, IB8, IP2, IP415121224015 kg50 kgA
    Ferrosilicon , with 30 percent or more but less than 90 percent silicon4.3UN1408III4.3, 6.1A1, A19, IB8, IP415121324025 kg100 kgA13, 40, 85, 103
    Ferrous arsenate6.1UN1608II6.1IB8, IP2, IP4None21224225 kg100 kgA
    DFerrous chloride, solid8NA1759II8IB8, IP2, IP415421224015 kg50 kgA
    DFerrous chloride, solution8NA1760II8B3, IB2, T11, TP2, TP271542022421 L30 LB40
    Ferrous metal borings or Ferrous metal shavings or Ferrous metal turnings or Ferrous metal cuttings in a form liable to self-heating4.2UN2793III4.2A1, A19, IB8, IP3, IP6None21324125 kg100 kgA
    Fertilizer ammoniating solution with free ammonia2.2UN10432.2306304314, 315Forbidden150 kgE40
    A WFibers or Fabrics, animal or vegetable or Synthetic, n.o.s. with animal or vegetable oil4.2UN1373III4.2137, IB8, IP3None213241ForbiddenForbiddenA
    Fibers or Fabrics impregnated with weakly nitrated nitrocellulose, n.o.s.4.1UN1353III4.1A1, IB8, IP3None21324025 kg100 kgD
    Start Printed Page 33369
    Films, nitrocellulose base, from which gelatine has been removed; film scrap, see Celluloid scrap
    Films, nitrocellulose base, gelatine coated (except scrap)4.1UN1324III4.1None183None25 kg100 kgD91
    Fire extinguisher charges, corrosive liquid8UN1774II8N41154202None1 L30 LA
    Fire extinguisher charges, expelling, explosive, see Cartridges, power device
    Fire extinguishers containing compressed or liquefied gas2.2UN10442.218, 110309309None75 kg150 kgA
    Firelighters, solid with flammable liquid4.1UN2623III4.1A1, A19None213None25 kg100 kgA
    Fireworks1.1GUN0333II1.1G108None62NoneForbiddenForbidden07
    Fireworks1.2GUN0334II1.2G108None62NoneForbiddenForbidden07
    Fireworks1.3GUN0335II1.3G108None62NoneForbiddenForbidden07
    Fireworks1.4GUN0336II1.4G108None62NoneForbidden75 kg06
    Fireworks1.4SUN0337II1.4S108None62None25 kg100 kg05
    First aid kits9UN3316915NoneNoneNone10 kg10 kgA
    WFish meal, stabilized or Fish scrap, stabilized9UN2216IIINoneIB8155218218No limitNo limitA88
    Fish meal, unstablized or Fish scrap, unstabilized4.2UN1374II4.2A1, A19, IB8, IP2None21224115 kg50 kgA119, 120
    Fissile radioactive materials, see Radioactive material, fissile, n.o.s.
    Flammable compressed gas, see Compressed or Liquefied gas, flammable, etc
    Flammable compressed gas (small receptacles not fitted with a dispersion device, not refillable), see Receptacles, etc
    Flammable gas in lighters, see Lighters or lighter refills, cigarettes, containing flammable gas
    GFlammable liquid, toxic, corrosive, n.o.s.3UN3286I3, 6.1, 8T14, TP2, TP13, TP27None201243Forbidden2.5 LE21, 40, 100
    II3, 6.1, 8IB2, T11, TP2, TP13, TP27None2022431 L5 LB21, 40, 100
    GFlammable liquids, corrosive, n.o.s.3UN2924I3, 8T14, TP2None2012430.5 L2.5 LE40
    II3, 8IB2, T11, TP2, TP27None2022431 L5 LB40
    III3, 8B1, IB3, T7, TP1, TP281502032425 L60 LA40
    GFlammable liquids, n.o.s.3UN1993I3T11, TP11502012431 L30 LE
    II3IB2, T7, TP1, TP8, TP281502022425 L60 LB
    III3B1, B52, IB3, T4, TP1, TP2915020324260 L220 LA
    GFlammable liquids, toxic, n.o.s.3UN1992I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LE40
    II3, 6.1IB2, T7, TP2, TP13None2022431 L60 LB40
    III3, 6.1B1, IB3, T7, TP1, TP2815020324260 L220 LA
    GFlammable solid, corrosive, inorganic, n.o.s.4.1UN3180II4.1, 8A1, IB6, IP215121224215 kg50 kgD40
    III4.1, 8A1, IB615121324225 kg100 kgD40
    GFlammable solid, inorganic, n.o.s.4.1UN3178II4.1A1, IB8, IP2, IP415121224015 kg50 kgB
    III4.1A1, IB8, IP315121324025 kg100 kgB
    GFlammable solid, organic, molten, n.o.s.4.1UN3176II4.1IB1, T3, TP3, TP26151212240ForbiddenForbiddenC
    III4.1IB1, T1, TP3, TP26151213240ForbiddenForbiddenC
    GFlammable solid, oxidizing, n.o.s.4.1UN3097II4.1, 5.1131None214214ForbiddenForbiddenE40
    III4.1, 5.1131None214214ForbiddenForbiddenD40
    GFlammable solid, toxic, inorganic, n.o.s.4.1UN3179II4.1, 6.1A1, IB6, IP215121224215 kg50 kgB40
    III4.1, 6.1A1, IB615121324225 kg100 kgB40
    GFlammable solids, corrosive, organic, n.o.s.4.1UN2925II4.1, 8A1, IB6, IP2None21224215 kg50 kgD40
    III4.1, 8A1, IB615121324225 kg100 kgD40
    GFlammable solids, organic, n.o.s.4.1UN1325II4.1A1, IB8, IP2, IP4, T3, TP115121224015 kg50 kgB
    III4.1A1, IB8, IP3, T1, TP115121324025 kg100 kgB
    GFlammable solids, toxic, organic, n.o.s.4.1UN2926II4.1, 6.1A1, IB6, IP2None21224215 kg50 kgB40
    III4.1, 6.1A1, IB615121324225 kg100 kgB40
    Flares, aerial1.3GUN0093II1.3GNone62NoneForbidden75 kg07
    Flares, aerial1.4GUN0403II1.4GNone62NoneForbidden75 kg06
    Flares, aerial1.4SUN0404II1.4SNone62None25 kg100 kg05
    Start Printed Page 33370
    Flares, aerial1.1GUN0420II1.1GNone62NoneForbiddenForbidden07
    Flares, aerial1.2GUN0421II1.2GNone62NoneForbiddenForbidden07
    Flares, airplane, see Flares, aerial
    Flares, signal, see Cartridges, signal
    Flares, surface1.3GUN0092II1.3GNone62NoneForbidden75 kg07
    Flares, surface1.1GUN0418II1.1GNone62NoneForbiddenForbidden07
    Flares, surface1.2GUN0419II1.2GNone62NoneForbiddenForbidden07
    Flares, water-activated, see Contrivances, water-activated, etc
    Flash powder1.1GUN0094II1.1GNone62NoneForbiddenForbidden15
    Flash powder1.3GUN0305II1.3GNone62NoneForbiddenForbidden15
    Flue dusts, poisonous, see Arsenical dust
    Fluoric acid, see Hydrofluoric acid, etc
    Fluorine, compressed2.3UN10452.3, 5.1, 81None302NoneForbiddenForbiddenD40, 89, 90
    Fluoroacetic acid6.1UN2642I6.1IB7, IP1None2112421 kg15 kgE
    Fluoroanilines6.1UN2941III6.1IB3, T4, TP115320324160 L220 LA
    Fluorobenzene3UN2387II3IB2, T4, TP11502022425 L60 LB
    Fluoroboric acid8UN1775II8A6, A7, B2, B15, IB2, N3, N34, T7, TP21542022421 L30 LA
    Fluorophosphoric acid anhydrous8UN1776II8A6, A7, B2, IB2, N3, N34, T8, TP2, TP12None2022421 L30 LA
    Fluorosilicates, n.o.s.6.1UN2856III6.1IB8, IP3153213240100 kg200 kgA26
    Fluorosilicic acid8UN1778II8A6, A7, B2, B15, IB2, N3, N34, T8, TP2, TP12None2022421 L30 LA
    Fluorosulfonic acid8UN1777I8A3, A6, A7, A10, B6, B10, N3, T10, TP2, TP12None2012430.5 L2.5 LD40
    Fluorotoluenes3UN2388II3IB2, T4, TP11502022425 L60 LB40
    Forbidden materials. See § 173.21Forbidden
    Formaldehyde, solutions, flammable3UN1198III3, 8B1, IB3, T4, TP11502032425 L60 LA40
    Formaldehyde, solutions, with not less than 25 percent formaldehyde8UN2209III8IB3, T4, TP11542032415 L60 LA
    Formalin, see Formaldehyde, solutions
    Formic acid8UN1779II8B2, B28, IB2, T7, TP21542022421 L30 LA40
    Fracturing devices, explosive, without detonators for oil wells1.1DUN0099II1.1DNone62NoneForbiddenForbidden07
    Fuel, aviation, turbine engine3UN1863I3T11, TP1, TP81502012431 L30 LE
    II3IB2, T4, TP1, TP81502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    DFuel oil (No. 1, 2, 4, 5, or 6)3NA1993III3B1, IB3, T4, TP1, TP2915020324260 L220 LA
    Fuel system components (including fuel control units (FCU), carburetors, fuel lines, fuel pumps) see Dangerous Goods in Apparatus or Dangerous Goods in Machinery
    Fulminate of mercury (dry)Forbidden
    Fulminate of mercury, wet, see Mercury fulminate, etc
    Fulminating goldForbidden
    Fulminating mercuryForbidden
    Fulminating platinumForbidden
    Fulminating silverForbidden
    Fulminic acidForbidden
    Fumaryl chloride8UN1780II8B2, IB2, T7, TP21542022421 L30 LC8, 40
    Fumigated lading, see §§ 172.302(g), 173.9 and 176.76(h)
    Fumigated transport vehicle or freight container see 173.9
    Furaldehydes6.1UN1199II6.1, 3IB2, T7, TP2None2022435 L60 LA
    Furan3UN2389I3T12, TP2, TP13None2012431 L30 LE40
    Furfuryl alcohol6.1UN2874III6.1IB3, T4, TP115320324160 L220 LA26, 74
    Furfurylamine3UN2526III3, 8B1, IB3, T4, TP11502032425 L60 LA40
    Fuse, detonating, metal clad, see Cord, detonating, metal clad
    Fuse, detonating, mild effect, metal clad, see Cord, detonating, mild effect, metal clad
    Fuse, igniter tubular metal clad1.4GUN0103II1.4GNone62NoneForbidden75 kg06
    Fuse, non-detonating instantaneous or quickmatch1.3GUN0101II1.3GNone62NoneForbiddenForbidden07
    Start Printed Page 33371
    Fuse, safety1.4SUN0105II1.4SNone62None25 kg100 kg05
    DFusee (railway or highway)4.1NA1325II4.1None184None15 kg50 kgB
    Fusel oil3UN1201II3IB2, T4, TP11502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Fuses, tracer, see Tracers for ammunition
    Fuzes, combination, percussion and time, see Fuzes, detonating (UN0257, UN0367); Fuzes, igniting (UN0317, UN0368)
    Fuzes, detonating1.1BUN0106II1.1BNone62NoneForbiddenForbidden11
    Fuzes, detonating1.2BUN0107II1.2BNone62NoneForbiddenForbidden11
    Fuzes, detonating1.4BUN0257II1.4B116None62NoneForbidden75 kg06
    Fuzes, detonating1.4SUN0367II1.4S116None62None25 kg100 kg05
    Fuzes, detonating, with protective features1.1DUN0408II1.1DNone62NoneForbiddenForbidden07
    Fuzes, detonating, with protective features1.2DUN0409II1.2DNone62NoneForbiddenForbidden07
    Fuzes, detonating, with protective features1.4DUN0410II1.4D116None62NoneForbidden75 kg06
    Fuzes, igniting1.3GUN0316II1.3GNone62NoneForbiddenForbidden07
    Fuzes, igniting1.4GUN0317II1.4GNone62NoneForbidden75 kg06
    Fuzes, igniting1.4SUN0368II1.4SNone62None25 kg100 kg05
    Galactsan trinitrateForbidden
    Gallium8UN2803III8None16224020 kg20 kgB48
    Gas cartridges, (flammable) without a release device, non-refillable2.1UN20372.1306304None1 kg15 kgB40
    Gas generator assemblies (aircraft), containing a non-flammable non-toxic gas and a propellant cartridge2.22.2None335None75 kg150 kgA
    DGas identification set2.3NA90352.36None194NoneForbiddenForbiddenD
    Gas oil3UN1202III3B1, IB3, T2, TP115020324260 L220 LA
    GGas, refrigerated liquid, flammable, n.o.s. (cryogenic liquid)2.1UN33122.1T75, TP5None316318ForbiddenForbiddenD40
    GGas, refrigerated liquid, n.o.s. (cryogenic liquid)2.2UN31582.2T75, TP532031631850 kg500 kgD
    GGas, refrigerated liquid, oxidizing, n.o.s. (cryogenic liquid)2.2UN33112.2, 5.1T75, TP5320316318ForbiddenForbiddenD
    Gas sample, non-pressurized, flammable, n.o.s., not refrigerated liquid2.1UN31672.1306302, 304None1 L5 LD
    Gas sample, non-pressurized, toxic, flammable, n.o.s., not refrigerated liquid2.3UN31682.3, 2.1306302NoneForbidden1 LD
    Gas sample, non-pressurized, toxic, n.o.s., not refrigerated liquid2.3UN31692.3306302, 304NoneForbidden1 LD
    DGasohol gasoline mixed with ethyl alcohol, with not more than 20 percent alcohol3NA1203II31502022425 L60 LE
    Gasoline3UN1203II3B33, IB2, T4, TP11502022425 L60 LE
    Gasoline, casinghead, see Gasoline
    Gelatine, blasting, see Explosive, blasting, type A
    Gelatine dynamites, see Explosive, blasting, type A
    Germane2.3UN21922.3, 2.12None192245ForbiddenForbiddenD40
    Glycerol-1,3-dinitrateForbidden
    Glycerol gluconate trinitrateForbidden
    Glycerol lactate trinitrateForbidden
    Glycerol alpha-monochlorohydrin6.1UN2689III6.1IB3, T4, TP115320324160 L220 LA
    Glyceryl trinitrate, see Nitroglycerin, etc
    Glycidaldehyde3UN2622II3, 6.1IB2, IP8, T7, TP11502022431 L60 LA40
    Grenades, hand or rifle, with bursting charge1.1DUN0284II1.1D62NoneForbiddenForbidden07
    Grenades, hand or rifle, with bursting charge1.2DUN0285II1.2D62NoneForbiddenForbidden07
    Grenades, hand or rifle, with bursting charge1.1FUN0292II1.1F62NoneForbiddenForbidden08
    Grenades, hand or rifle, with bursting charge1.2FUN0293II1.2F62NoneForbiddenForbidden08
    Grenades, illuminating, see Ammunition, illuminating, etc
    Grenades, practice, hand or rifle1.4SUN0110II1.4S62None25 kg100 kg05
    Grenades, practice, hand or rifle1.3GUN0318II1.3G62NoneForbiddenForbidden07
    Grenades, practice, hand or rifle1.2GUN0372II1.2G62NoneForbiddenForbidden07
    Grenades practice Hand or rifle1.4GUN0452II1.4G62NoneForbidden75 kg06
    Grenades, smoke, see Ammunition, smoke, etc
    Guanidine nitrate5.1UN1467III5.1A1, IB8, IP315221324025 kg100 kgA73
    Guanyl nitrosaminoguanylidene hydrazine (dry)Forbidden
    Start Printed Page 33372
    Guanyl nitrosaminoguanylidene hydrazine, wetted with not less than 30 percent water, by mass1.1AUN0113II1.1A111, 117None62NoneForbiddenForbidden12
    Guanyl nitrosaminoguanyltetrazene (dry)Forbidden
    Guanyl nitrosaminoguanyltetrazene, wetted or Tetrazene, wetted with not less than 30 percent water or mixture of alcohol and water, by mass1.1AUN0114II1.1A111, 117None62NoneForbiddenForbidden12
    Gunpowder, compressed or Gunpowder in pellets, see Black powder (UN 0028)
    Gunpowder, granular or as a meal, see Black powder (UN 0027)
    Hafnium powder, dry4.2UN2545I4.2None211242ForbiddenForbiddenD
    II4.2A19, A20, IB6, IP2, N34None21224115 kg50 kgD
    III4.2IB8, IP3None21324125 kg100 kgD
    Hafnium powder, wetted with not less than 25 percent water (a visible excess of water must be present) (a) mechanically produced, particle size less than 53 microns; (b) chemically produced, particle size less than 840 microns4.1UN1326II4.1A6, A19, A20, IB6, IP2, N34None21224115 kg50 kgE
    Hand signal device, see Signal devices, hand
    Hazardous substances, liquid or solid, n.o.s., see Environmentally hazardous substances, etc
    D GHazardous waste, liquid, n.o.s.9NA3082III9IB3, T2, TP1155203241No limitNo limitA
    D GHazardous waste, solid, n.o.s.9NA3077III9B54, IB8, IP2155213240No limitNo limitA
    Heating oil, light3UN1202III3B1, IB3, T2, TP115020324260 L220 LA
    Helium, compressed2.2UN10462.2306302302, 31475 kg150 kgA85
    Helium-oxygen mixture, see Rare gases and oxygen mixtures
    Helium, refrigerated liquid (cryogenic liquid)2.2UN19632.2T75, TP532031631850 kg500 kgB
    Heptafluoropropane or Refrigerant gas R 2272.2UN32962.2T50306304314, 31575 kg150 kgA
    n-Heptaldehyde3UN3056III3B1, IB3, T2, TP115020324260 L220 LA
    Heptanes3UN1206II3IB2, T4, TP11502022425 L60 LB
    n-Heptene3UN2278II3IB2, T4, TP11502022425 L60 LB
    Hexachloroacetone6.1UN2661III6.1IB3, T4, TP115320324160 L220 LB12, 40
    Hexachlorobenzene6.1UN2729III6.1IB315320324160 L220 LA
    Hexachlorobutadiene6.1UN2279III6.1IB3, T4, TP115320324160 L220 LA
    Hexachlorocyclopentadiene6.1UN2646I6.12, B9, B14, B32, B74, B77, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Hexachlorophene6.1UN2875III6.1IB8, IP3153213240100 kg200 kgA
    Hexadecyltrichlorosilane8UN1781II8A7, B2, B6, IB2, N34, T7, TP2None202242Forbidden30 LC40
    Hexadienes3UN2458II3IB2, T4, TP1None2022425 L60 LB
    Hexaethyl tetraphosphate and compressed gas mixtures2.3UN16122.33None334NoneForbiddenForbiddenD40
    Hexaethyl tetraphosphate, liquid6.1UN1611II6.1IB2, IP2, IP4, N76None2022435 L60 LE40
    Hexaethyl tetraphosphate, solid6.1UN1611II6.1IB8, IP2, IP4, N76None21224225 kg100 kgE40
    Hexafluoroacetone2.3UN24202.3, 82, B9, B14None304314, 315ForbiddenForbiddenD40
    Hexafluoroacetone hydrate6.1UN2552II6.1IB2, T7, TP2None2022435 L60 LB40
    Hexafluoroethane, compressed or Refrigerant gas R 1162.2UN21932.2306304314, 31575 kg150 kgA
    Hexafluorophosphoric acid8UN1782II8A6, A7, B2, IB2, N3, N34, T8, TP2, TP12None2022421 L30 LA
    Hexafluoropropylene compressed or Refrigerant gas R 12162.2UN18582.2T50306304314, 31575 kg150 kgA
    Hexaldehyde3UN1207III3B1, IB3, T2, TP115020324260 L220 LA
    Hexamethylene diisocyanate6.1UN2281II6.1IB2, T7, TP2, TP13None2022435 L60 LC13, 40
    Hexamethylene triperoxide diamine (dry)Forbidden
    Hexamethylenediamine, solid8UN2280III8IB8, IP3, T4, TP115421324025 kg100 kgA12
    Hexamethylenediamine solution8UN1783II8IB2, T7, TP2None2022421 L30 LA
    III8IB3, T4, TP11542032415 L60 LA
    Hexamethyleneimine3UN2493II3, 8IB2, T7, TP1None2022431 L5 LB40
    Hexamethylenetetramine4.1UN1328III4.1A1, IB8, IP315121324025 kg100 kgA
    Hexamethylol benzene hexanitrateForbidden
    Hexanes3UN1208II3IB2, T4, TP11502022425 L60 LE
    Start Printed Page 33373
    2,2',4,4',6,6'- Hexanitro-3,3'-dihydroxyazobenzene (dry)Forbidden
    Hexanitroazoxy benzeneForbidden
    N,N'-(hexanitrodiphenyl) ethylene dinitramine (dry)Forbidden
    Hexanitrodiphenyl ureaForbidden
    2,2',3',4,4',6-HexanitrodiphenylamineForbidden
    Hexanitrodiphenylamine or Dipicrylamine or Hexyl1.1DUN0079II1.1DNone62NoneForbiddenForbidden10
    2,3',4,4',6,6'-HexanitrodiphenyletherForbidden
    HexanitroethaneForbidden
    HexanitrooxanilideForbidden
    Hexanitrostilbene1.1DUN0392II1.1DNone62NoneForbiddenForbidden10
    Hexanoic acid, see Corrosive liquids, n.o.s.
    Hexanols3UN2282III3B1, IB3, T2, TP115020324260 L220 LA
    1-Hexene3UN2370II3IB2, T4, TP11502022425 L60 LE
    Hexogen and cyclotetramethylenetetranitramine mixtures, wetted or desensitized see RDX and HMX mixtures, wetted or desensitized etc
    Hexogen and HMX mixtures, wetted or desensitized see RDX and HMX mixtures, wetted or desensitized etc
    Hexogen and octogen mixtures, wetted or desensitized see RDX and HMX mixtures, wetted or desensitized etc
    Hexogen, see Cyclotrimethylenetrinitramine, etc
    Hexolite, or Hexotol dry or wetted with less than 15 percent water, by mass1.1DUN0118II1.1DNone62NoneForbiddenForbidden10
    Hexotonal1.1DUN0393II1.1DNone62NoneForbiddenForbidden10
    Hexyl, see Hexanitrodiphenylamine
    Hexyltrichlorosilane8UN1784II8A7, B2, B6, IB2, N34, T7, TP2, TP13None202242Forbidden30 LC40
    High explosives, see individual explosives' entries
    HMX, see Cyclotetramethylenete tranitramine, etc
    Hydrazine, anhydrous or Hydrazine aqueous solutions with more than 64 percent hydrazine, by mass8UN2029I8, 3, 6.1A3, A6, A7, A10, B7, B16, B53None201243Forbidden2.5 LD21, 40, 42, 100
    Hydrazine, aqueous solution with not more than 37 percent hydrazine, by mass6.1UN3293III6.1IB3, T4, TP115320324160 L220 LA
    Hydrazine azideForbidden
    Hydrazine chlorateForbidden
    Hydrazine dicarbonic acid diazideForbidden
    Hydrazine hydrate or Hydrazine aqueous solutions, with not less than 37 percent but not more than 64 percent hydrazine, by mass8UN2030II8, 6.1B16, B53, IB2, T7, TP2, TP13None202243Forbidden30 LD40, 42, 82
    Hydrazine perchlorateForbidden
    Hydrazine selenateForbidden
    Hydriodic acid, anhydrous, see Hydrogen iodide, anhydrous
    Hydriodic acid8UN1787II8A3, A6, B2, IB2, N41, T7, TP21542022421 L30 LC
    III8IB3, T4, TP11542032415 L60 LC8
    Hydrobromic acid, anhydrous, see Hydrogen bromide, anhydrous
    Hydrobromic acid, with more than 49 percent hydrobromic acid8UN1788II8B2, B15, IB2, N41, T7, TP2154202242ForbiddenForbiddenC
    III8IB3, T4, TP1154203241ForbiddenForbiddenC8
    Hydrobromic acid, with not more than 49 percent hydrobromic acid8UN1788II8A3, A6, B2, B15, IB2, N41, T7, TP21542022421 L30 LC
    III8IB3, T4, TP11542032415 L30 LC8
    Hydrocarbon gas mixture, compressed, n.o.s.2.1UN19642.1306302314, 315Forbidden150 kgE40
    Hydrocarbon gas mixture, liquefied, n.o.s.2.1UN19652.1T50306304314, 315Forbidden150 kgE40
    Hydrocarbons, liquid, n.o.s.3UN3295I3T11, TP1, TP81502012431 L30 LE
    Start Printed Page 33374
    II3IB2, T7, TP1, TP8, TP281502022425 L60 LB
    III3B1, IB3, T4, TP1, TP2915020324260 L220 LA
    Hydrochloric acid, anhydrous, see Hydrogen chloride, anhydrous
    Hydrochloric acid8UN1789II8A3, A6, B3, B15, IB2, N41, T8, TP2, TP121542022421 L30 LC
    III8IB3, T4, TP1, TP121542032415 L60 LC8
    Hydrocyanic acid, anhydrous, see Hydrogen cyanide etc
    Hydrocyanic acid, aqueous solutions or Hydrogen cyanide, aqueous solutions with not more than 20 percent hydrogen cyanide6.1UN1613I6.12, B61, B65, B77, B82, T20, TP2, TP13None195244ForbiddenForbiddenD40
    DHydrocyanic acid, aqueous solutions with less than 5 percent hydrogen cyanide6.1NA1613II6.1IB1, T14, TP2, TP13, TP27None195243Forbidden5 LD40
    Hydrocyanic acid, liquefied, see Hydrogen cyanide, etc
    Hydrocyanic acid (prussic), unstabilizedForbidden
    Hydrofluoric acid and Sulfuric acid mixtures8UN1786I8, 6.1A6, A7, B15, B23, N5, N34, T10, TP2, TP12, TP13None201243Forbidden2.5 LD40
    Hydrofluoric acid, anhydrous, see Hydrogen fluoride, anhydrous
    Hydrofluoric acid, with more than 60 percent strength8UN1790I8, 6.1A6, A7, B4, B15, B23, N5, N34, T10, TP2, TP12, TP13None2012430.5 L2.5 LD12, 40
    Hydrofluoric acid, with not more than 60 percent strength8UN1790II8, 6.1A6, A7, B15, IB2, N5, N34, T8, TP2, TP12None2022431 L30 LD12, 40
    Hydrofluoroboric acid, see Fluoroboric acid
    Hydrofluorosilicic acid, see Fluorosilicic acid
    Hydrogen and Methane mixtures, compressed2.1UN20342.1306302302, 314, 315Forbidden150 kgE40
    Hydrogen bromide, anhydrous2.3UN10482.3, 83, B14None304314, 315Forbidden25 kgD40
    Hydrogen chloride, anhydrous2.3UN10502.3, 83None304NoneForbiddenForbiddenD40
    Hydrogen chloride, refrigerated liquid2.3UN21862.3, 83, B6NoneNone314, 315ForbiddenForbiddenB40
    Hydrogen, compressed2.1UN10492.1306302302, 314Forbidden150 kgE40, 57
    Hydrogen cyanide, solution in alcohol with not more than 45 percent hydrogen cyanide6.1UN3294I6.1, 32, 25, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Hydrogen cyanide, stabilized with less than 3 percent water6.1UN1051I6.1, 31, B35, B61, B65, B77, B82None195244ForbiddenForbiddenD40
    Hydrogen cyanide, stabilized, with less than 3 percent water and absorbed in a porous inert material6.1UN1614I6.15None195NoneForbiddenForbiddenD25, 40
    Hydrogen fluoride, anhydrous8UN1052I8, 6.13, B7, B46, B71, B77, T10, TP2None163243ForbiddenForbiddenD40
    Hydrogen iodide, anhydrous2.3UN21972.33, B14None304314, 315ForbiddenForbiddenD40
    Hydrogen iodide solution, see Hydriodic acid, solution
    Hydrogen peroxide and peroxyacetic acid mixtures, stabilized with acids, water and not more than 5 percent peroxyacetic acid5.1UN3149II5.1, 8A2, A3, A6, B53, IB2, IP5, T7, TP2, TP6, TP24None2022431 L5 LD25, 66, 75, 106
    Hydrogen peroxide, aqueous solutions with more than 40 percent but not more than 60 percent hydrogen peroxide (stabilized as necessary)5.1UN2014II5.1, 812, A3, A6, B53, B80, B81, B85, IB2, IP5, T7, TP2, TP6, TP24None202243ForbiddenForbiddenD25, 66, 75, 106
    Hydrogen peroxide, aqueous solutions with not less than 20 percent but not more than 40 percent hydrogen peroxide (stabilized as necessary)5.1UN2014II5.1, 8A2, A3, A6, B53, IB2, IP5, T7, TP2, TP6, TP24None2022431 L5 LD25, 66, 75, 106
    Hydrogen peroxide, aqueous solutions with not less than 8 percent but less than 20 percent hydrogen peroxide (stabilized as necessary)5.1UN2984III5.1A1, IB2, IP5, T4, TP1, TP6, TP241522032412.5 L30 LB25, 75, 106
    Start Printed Page 33375
    Hydrogen peroxide, stabilized or Hydrogen peroxide aqueous solutions, stabilized with more than 60 percent hydrogen peroxide5.1UN2015I5.1, 812, A3, A6, B53, B80, B81, B85, T10, TP2, TP6, TP24None201243ForbiddenForbiddenD25, 66, 75, 106
    Hydrogen, refrigerated liquid (cryogenic liquid)2.1UN19662.1T75, TP5None316318, 319ForbiddenForbiddenD40
    Hydrogen selenide, anhydrous2.3UN22022.3, 2.11None192245ForbiddenForbiddenD40
    Hydrogen sulfate, see Sulfuric acid
    Hydrogen sulfide2.3UN10532.3, 2.12, B9, B14None304314, 315ForbiddenForbiddenD40
    Hydrogendifluorides, n.o.s. solid8UN1740II8IB5, IP2, IP4, N3, N34None21224015 kg50 kgA25, 26, 40
    III8IB8, IP3, N3, N3415421324025 kg100 kgA25, 26, 40
    Hydrogendifluorides, n.o.s. solutions8UN1740II8IB2, N3, N34None2022421 L30 LA25, 26, 40
    III8IB3, IP3, N3, N341542032415 L60 LA25, 26, 40
    Hydroquinone6.1UN2662III6.1IB8, IP3, T4, TP1153213240100 kg200 kgA
    Hydrosilicofluoric acid, see Fluorosilicic acid
    Hydroxyl amine iodideForbidden
    Hydroxylamine sulfate8UN2865III8IB8, IP315421324025 kg100 kgA
    Hypochlorite solutions8UN1791II8A7, B2, B15, IB2, IP5, N34, T7, TP2, TP241542022421 L30 LB26
    III8IB3, N34, T4, TP2, TP241542032415 L60 LB26
    Hypochlorites, inorganic, n.o.s.5.1UN3212II5.1IB8, IP2, IP41522122405 kg25 kgD48, 56, 58, 69, 106, 116, 118
    Hyponitrous acidForbidden
    Igniter fuse, metal clad, see Fuse, igniter, tubular, metal clad
    Igniters1.1GUN0121II1.1GNone62NoneForbiddenForbidden07
    Igniters1.2GUN0314II1.2GNone62NoneForbiddenForbidden07
    Igniters1.3GUN0315II1.3GNone62NoneForbiddenForbidden07
    Igniters1.4GUN0325II1.4GNone62NoneForbidden75 kg06
    Igniters1.4SUN0454II1.4SNone62None25 kg100 kg05
    3,3'-Iminodipropylamine8UN2269III8IB3, T4, TP21542032415 L60 LA
    GInfectious substances, affecting animals only6.2UN29006.2134196None50 mL or 50 g4 L or 4 kgB
    GInfectious substances, affecting humans6.2UN28146.2134196None50 mL or 50 g4 L or 4 kgB
    Inflammable, see Flammable
    Initiating explosives (dry)Forbidden
    Inositol hexanitrate (dry)Forbidden
    GInsecticide gases, n.o.s.2.2UN19682.2306304314, 31575 kg150 kgA
    GInsecticide gases, flammable, n.o.s.2.1UN33542.1T50306304314, 315Forbidden150 kgD40
    GInsecticide gases, toxic, flammable, n.o.s. Inhalation hazard Zone A2.3UN33552.3, 2.11None192245ForbiddenForbiddenD40
    GInsecticide gases, toxic, flammable, n.o.s. Inhalation hazard Zone B2.3UN33552.3, 2.12, B9, B14None302, 305314, 315ForbiddenForbiddenD40
    GInsecticide gases, toxic, flammable, n.o.s. Inhalation hazard Zone C2.3UN33552.3, 2.13, B14None302, 305314, 315ForbiddenForbiddenD
    GInsecticide gases, toxic, flammable, n.o.s. Inhalation hazard Zone D2.3UN33552.3, 2.14None302, 305314, 315ForbiddenForbiddenD
    GInsecticide gases, toxic, n.o.s.2.3UN19672.33None193, 334245ForbiddenForbiddenD40
    Inulin trinitrate (dry)Forbidden
    Iodine azide (dry)Forbidden
    Iodine monochloride8UN1792II8B6, IB8, IP2, IP4, N41, T7, TP2None212240Forbidden50 kgD40, 66, 74, 89, 90
    Iodine pentafluoride5.1UN2495I5.1, 6.1, 8None205243Forbidden2.5 LD25, 40, 66, 90
    2-Iodobutane3UN2390II3IB2, T4, TP11502022425 L60 LB
    Iodomethylpropanes3UN2391II3IB2, T4, TP11502022425 L60 LB
    Iodopropanes3UN2392III3B1, IB3, T2, TP115020324260 L220 LA
    Iodoxy compounds (dry)Forbidden
    Iridium nitratopentamine iridium nitrateForbidden
    Iron chloride, see Ferric chloride
    Iron oxide, spent, or Iron sponge, spent obtained from coal gas purification4.2UN1376III4.2B18, IB8, IP3None213240ForbiddenForbiddenE
    Start Printed Page 33376
    Iron pentacarbonyl6.1UN1994I6.1, 31, B9, B14, B30, B72, B77, T22, TP2, TP13, TP38, TP44None192244ForbiddenForbiddenD40
    Iron sesquichloride, see Ferric chloride
    Irritating material, see Tear gas substances, etc
    Isobutane see also Petroleum gases, liquefied2.1UN19692.119, T50306304314, 315Forbidden150 kgE40
    Isobutanol or Isobutyl alcohol3UN1212III3B1, IB3, T2, TP115020324260 L220 LA
    Isobutyl acetate3UN1213II3IB2, T4, TP11502022425 L60 LB
    Isobutyl acrylate, stabilized3UN2527III3B1, IB3, T2, TP115020324260 L220 LA
    Isobutyl alcohol, see Isobutanol
    Isobutyl aldehyde, see Isobutyraldehyde
    DIsobutyl chloroformate6.1NA2742I6.1, 3, 82, B9, B14, B32, B74, T20, TP4, TP12, TP13, TP38, TP45None2272441 L30 LA12, 13, 22, 25, 40, 48, 100
    Isobutyl formate3UN2393II3IB2, T4, TP11502022425 L60 LB
    Isobutyl isobutyrate3UN2528III3B1, IB3, T2, TP115020324260 L220 LA
    +Isobutyl isocyanate3UN2486I3, 6.11, B9, B14, B30, B72, T22, TP2, TP13, TP27None226244ForbiddenForbiddenD40
    Isobutyl methacrylate, stabilized3UN2283III3B1, IB3, T2, TP115020324260 L220 LA
    Isobutyl propionate3UN2394III3B1, IB3, T2, TP115020324260 L220 LB
    Isobutylamine3UN1214II3, 8IB2, T7, TP1None2022431 L5 LB40
    Isobutylene see also Petroleum gases, liquefied2.1UN10552.119, T50306304314, 315Forbidden150 kgE40
    Isobutyraldehyde or Isobutyl aldehyde3UN2045II3IB2, T4, TP11502022425 L60 LE40
    Isobutyric acid3UN2529III3, 8B1, IB3, T4, TP11502032425 L60 LA
    Isobutyronitrile3UN2284II3, 6.1IB2, T7, TP2, TP13None2022431 L60 LE40
    Isobutyryl chloride3UN2395II3, 8IB1, T7, TP2None2022431 L5 LC40
    GIsocyanates, flammable, toxic, n.o.s. or Isocyanate solutions, flammable, toxic, n.o.s. flash point less than 23 degrees C3UN2478II3, 6.15, A3, A7, IB2, T11, TP2, TP13, TP27None2022431 L60 LD40
    GIsocyanates, toxic, flammable, n.o.s. or Isocyanate solutions, toxic, flammable, n.o.s., flash point not less than 23 degrees C but not more than 61 degrees C and boiling point less than 300 degrees C6.1UN3080II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB25, 40, 48
    GIsocyanates, toxic, n.o.s. or Isocyanate solutions, toxic, n.o.s., flash point more than 61 degrees C and boiling point less than 300 degrees C6.1UN2206II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LE25, 40, 48
    III6.1IB3, T7, TP1, TP13, TP2815320324160 L220 LE25, 40, 48
    Isocyanatobenzotrifluorides6.1UN2285II6.1, 35, IB2, T7, TP2None2022435 L60 LD25, 40, 48
    Isoheptenes3UN2287II3IB2, T4, TP11502022425 L60 LB
    Isohexenes3UN2288II3IB2, IP8, T11, TP11502022425 L60 LE
    Isooctane, see Octanes
    Isooctenes3UN1216II3IB2, T4, TP11502022425 L60 LB
    Isopentane, see Pentane
    Isopentanoic acid, see Corrosive liquids, n.o.s.
    Isopentenes3UN2371I3T11, TP21502012431 L30 LE
    Isophorone diisocyanate6.1UN2290III6.1IB3, T4, TP215320324160 L220 LB40
    Isophoronediamine8UN2289III8IB3, T4, TP11542032415 L60 LA
    Isoprene, stabilized3UN1218I3T11, TP21502012431 L30 LE
    Isopropanol or Isopropyl alcohol3UN1219II3IB2, T4, TP11502022425 L60 LB
    Isopropenyl acetate3UN2403II3IB2, T4, TP11502022425 L60 LB
    Isopropenylbenzene3UN2303III3B1, IB3, T2, TP115020324260 L220 LA
    Isopropyl acetate3UN1220II3IB2, T4, TP11502022425 L60 LB
    Isopropyl acid phosphate8UN1793III8IB8, IP3, T4, TP115421324025 kg100 kgA
    Isopropyl alcohol, see Isopropanol
    Isopropyl butyrate3UN2405III3B1, IB3, T2, TP115020324260 L220 LA
    Isopropyl chloroacetate3UN2947III3B1, IB3, T2, TP115020324260 L220 LA
    Isopropyl chloroformate6.1UN2407I6.1, 3, 82, B9, B14, B32, B74, B77, T20, TP2, TP13, TP38, TP44None227244ForbiddenForbiddenB40
    Isopropyl 2-chloropropionate3UN2934III3B1, IB3, T2, TP115020324260 L220 LA
    Isopropyl isobutyrate3UN2406II3IB2, T4, TP11502022425 L60 LB
    +Isopropyl isocyanate3UN2483I3, 6.11, B9, B14, B30, B72, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenD40
    Isopropyl mercaptan, see Propanethiols
    Start Printed Page 33377
    Isopropyl nitrate3UN1222II3IB2, IP7150202None5 L60 LD
    Isopropyl phosphoric acid, see Isopropyl acid phosphate
    Isopropyl propionate3UN2409II3IB2, T4, TP11502022425 L60 LB
    Isopropylamine3UN1221I3, 8T11, TP2None2012430.5 L2.5 LE
    Isopropylbenzene3UN1918III3B1, IB3, T2, TP115020324260 L220 LA
    Isopropylcumyl hydroperoxide, with more than 72 percent in solutionForbidden
    Isosorbide dinitrate mixture with not less than 60 percent lactose, mannose, starch or calcium hydrogen phosphate4.1UN2907II4.1IB6, IP2None212None15 kg50 kgE
    Isosorbide-5-mononitrate4.1UN3251III4.166, IB8151213240ForbiddenForbiddenD12
    Isothiocyanic acidForbidden
    Jet fuel, see Fuel aviation, turbine engine
    DJet perforating guns, charged oil well, with detonator1.1DNA0124II1.1D55, 56None62NoneForbiddenForbidden07
    DJet perforating guns, charged oil well, with detonator1.4DNA0494II1.4D55, 56None62NoneForbiddenForbidden06
    Jet perforating guns, charged oil well, without detonator1.1DUN0124II1.1D55None62NoneForbiddenForbidden07
    Jet perforating guns, charged, oil well, without detonator1.4DUN0494II1.4D55, 114None62NoneForbidden300 kg06
    Jet perforators, see Charges, shaped, etc
    Jet tappers, without detonator, see Charges, shaped, etc
    Jet thrust igniters, for rocket motors or Jato, see Igniters
    Jet thrust unit (Jato), see Rocket motors
    Kerosene3UN1223III3B1, IB3, T2, TP215020324260 L220 LA
    GKetones, liquid, n.o.s.3UN1224I3T11, TP1, TP8, TP27None2012431 L30 LE
    II3IB2, T7, TP1, TP8, TP281502022425 L60 LB
    III3B1, IB3, T4, TP1, TP2915020324260 L220 LA
    Krypton, compressed2.2UN10562.2306302None75 kg150 kgA
    Krypton, refrigerated liquid (cryogenic liquid)2.2UN19702.2T75, TP5320NoneNone50 kg500 kgB
    Lacquer base or lacquer chips, nitrocellulose, dry, see Nitrocellulose, etc. (UN 2557)
    Lacquer base or lacquer chips, plastic, wet with alcohol or solvent, see Nitrocellulose (UN2059, UN2555, UN2556, UN2557) or Paint etc.(UN1263)
    Lead acetate6.1UN1616III6.1IB8, IP3153213240100 kg200 kgA
    Lead arsenates6.1UN1617II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Lead arsenites6.1UN1618II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Lead azide (dry)Forbidden
    Lead azide, wetted with not less than 20 percent water or mixture of alcohol and water, by mass1.1AUN0129II1.1A111, 117None62NoneForbiddenForbidden12
    Lead compounds, soluble, n.o.s.6.1UN2291III6.1138, IB8, IP3153213240100 kg200 kgA
    Lead cyanide6.1UN1620II6.1IB8, IP2, IP4None21224225 kg100 kgA26
    Lead dioxide5.1UN1872III5.1A1, IB8, IP315221324025 kg100 kgA
    Lead dross, see Lead sulfate, with more than 3 percent free acid
    Lead nitrate5.1UN1469II5.1, 6.1IB8, IP2, IP4None2122425 kg25 kgA
    Lead nitroresorcinate (dry)Forbidden
    Lead perchlorate, solid5.1UN1470II5.1, 6.1IB6, IP2, T4, TP1None2122425 kg25 kgA56, 58, 106
    Lead perchlorate, solution5.1UN1470II5.1, 6.1IB1, T4, TP1None2022431 L5 LA56, 58, 106
    Lead peroxide, see Lead dioxide
    Lead phosphite, dibasic4.1UN2989II4.1IB8, IP2, IP4None2122405 kg25 kgB34
    III4.1IB8, IP315121324015 kg50 kgB34
    Lead picrate (dry)Forbidden
    Lead styphnate (dry)Forbidden
    Lead styphnate, wetted or Lead trinitroresorcinate, wetted with not less than 20 percent water or mixture of alcohol and water, by mass1.1AUN0130II1.1A111, 117None62NoneForbiddenForbidden12
    Lead sulfate with more than 3 percent free acid8UN1794II8IB8, IP2, IP415421224015 kg50 kgA
    Lead trinitroresorcinate, see Lead styphnate, etc
    Start Printed Page 33378
    Life-saving appliances, not self inflating containing dangerous goods as equipment9UN3072None143None219NoneNo limitNo limitA
    Life-saving appliances, self inflating9UN2990NoneNone219NoneNo limitNo limitA
    Lighter replacement cartridges containing liquefied petroleum gases (and similar devices, each not exceeding 65 grams), see Lighters or lighter refills etc. containing flammable gas
    Lighters, fuse1.4SUN0131II1.4SNone62None25 kg100 kg05
    Lighters or Lighter refills cigarettes, containing flammable gas2.1UN10572.1N10None21, 308None1 kg15 kgB40
    Lime, unslaked, see Calcium oxide
    GLiquefied gas, flammable, n.o.s.2.1UN31612.1T50306304314, 315Forbidden150 kgD40
    GLiquefied gas, n.o.s.2.2UN31632.2T50306304314, 31575 kg150 kgA
    GLiquefied gas, oxidizing, n.o.s.2.2UN31572.2, 5.1306304314, 31575 kg150 kgD
    G ILiquefied gas, toxic, corrosive, n.o.s. Inhalation Hazard Zone A2.3UN33082.3, 81None192245ForbiddenForbiddenD40
    G ILiquefied gas, toxic, corrosive, n.o.s. Inhalation Hazard Zone B2.3UN33082.3, 82None304314, 315ForbiddenForbiddenD40
    G ILiquefied gas, toxic, corrosive, n.o.s. Inhalation Hazard Zone C2.3UN33082.3, 83None304314, 315ForbiddenForbiddenD40
    G ILiquefied gas, toxic, corrosive, n.o.s. Inhalation Hazard Zone D2.3UN33082.3, 84None304314, 315ForbiddenForbiddenD40
    G ILiquefied gas, toxic, flammable, corrosive, n.o.s. Inhalation Hazard Zone A2.3UN33092.3, 2.1, 81None192245ForbiddenForbiddenD17, 40
    G ILiquefied gas toxic, flammable, corrosive, n.o.s. Inhalation Hazard Zone B2.3UN33092.3, 2.1, 82None304314, 315ForbiddenForbiddenD17, 40
    G ILiquefied gas, toxic, flammable, corrosive, n.o.s. Inhalation Hazard Zone C2.3UN33092.3, 2.1, 83None304314, 315ForbiddenForbiddenD17, 40
    G ILiquefied gas, toxic, flammable, corrosive, n.o.s. Inhalation Hazard Zone D2.3UN33092.3, 2.1, 84None304314, 315ForbiddenForbiddenD17, 40
    GLiquefied gas, toxic, flammable, n.o.s. Inhalation Hazard Zone A2.3UN31602.3, 2.11None192245ForbiddenForbiddenD40
    GLiquefied gas, toxic, flammable, n.o.s. Inhalation Hazard Zone B2.3UN31602.3, 2.12, B9, B14None304314, 315ForbiddenForbiddenD40
    GLiquefied gas, toxic, flammable, n.o.s. Inhalation Hazard Zone C2.3UN31602.3, 2.13, B14None304314, 315ForbiddenForbiddenD40
    GLiquefied gas, toxic, flammable, n.o.s. Inhalation Hazard Zone D2.3UN31602.3, 2.14None304314, 315ForbiddenForbiddenD40
    GLiquefied gas, toxic, n.o.s. Inhalation Hazard Zone A2.3UN31622.31None192245ForbiddenForbiddenD40
    GLiquefied gas, toxic, n.o.s. Inhalation Hazard Zone B2.3UN31622.32, B9, B14None304314, 315ForbiddenForbiddenD40
    GLiquefied gas, toxic, n.o.s. Inhalation Hazard Zone C2.3UN31622.33, B14None304314, 315ForbiddenForbiddenD40
    GLiquefied gas, toxic, n.o.s. Inhalation Hazard Zone D2.3UN31622.34None304314, 315ForbiddenForbiddenD40
    G ILiquefied gas, toxic, oxidizing, corrosive, n.o.s. Inhalation Hazard Zone A2.3UN33102.3, 5.1, 81None192245ForbiddenForbiddenD40, 89, 90
    G ILiquefied gas, toxic, oxidizing, corrosive, n.o.s. Inhalation Hazard Zone B2.3UN33102.3, 2.1, 82None304314, 315ForbiddenForbiddenD40, 89, 90
    G ILiquefied gas, toxic, oxidizing, corrosive, n.o.s. Inhalation Hazard Zone C2.3UN33102.3, 2.1, 83None304314, 315ForbiddenForbiddenD40, 89, 90
    G ILiquefied gas, toxic, oxidizing, corrosive, n.o.s. Inhalation Hazard Zone D2.3UN33102.3, 2.1, 84None304314, 315ForbiddenForbiddenD40, 89, 90
    GLiquefied gas, toxic, oxidizing, n.o.s. Inhalation Hazard Zone A2.3UN33072.3, 5.11None192245ForbiddenForbiddenD40
    GLiquefied gas, toxic, oxidizing, n.o.s. Inhalation Hazard Zone B2.3UN33072.3, 5.12None304314, 315ForbiddenForbiddenD40
    GLiquefied gas, toxic, oxidizing, n.o.s. Inhalation Hazard Zone C2.3UN33072.3, 5.13None304314, 315ForbiddenForbiddenD40
    GLiquefied gas, toxic, oxidizing, n.o.s. Inhalation Hazard Zone D2.3UN33072.3, 5.14None304314, 315ForbiddenForbiddenD40
    Liquefied gases, non-flammable charged with nitrogen, carbon dioxide or air2.2UN10582.2306304None75 kg150 kgA
    Start Printed Page 33379
    Liquefied hydrocarbon gas, see Hydrocarbon gas mixture, liquefied, n.o.s.
    Liquefied natural gas, see Methane, etc. (UN 1972)
    Liquefied petroleum gas see Petroleum gases, liquefied
    Lithium4.3UN1415I4.3A7, A19, IB1, IP1, N45None211244Forbidden15 kgE
    Lithium acetylide ethylenediamine complex, see Water reactive solid etc
    Lithium alkyls4.2UN2445I4.2, 4.3B11, T21, TP2, TP7None181244ForbiddenForbiddenD
    Lithium aluminum hydride4.3UN1410I4.3A19None211242Forbidden15 kgE
    Lithium aluminum hydride, ethereal4.3UN1411I4.3, 3A2, A3, A11, N34None201244Forbidden1 LD40
    Lithium batteries, contained in equipment9UN3091II929185(i)185None5 kg5 kgA
    Lithium batteries packed with equipment9UN3091II929185185None5 kg gross35 kg grossA
    Lithium battery9UN3090II929185185None5 kg gross35 kg grossA
    Lithium borohydride4.3UN1413I4.3A19, N40None211242Forbidden15 kgE
    Lithium ferrosilicon4.3UN2830II4.3A19, IB7, IP215121224115 kg50 kgE40, 85, 103
    Lithium hydride4.3UN1414I4.3A19, N40None211242Forbidden15 kgE
    Lithium hydride, fused solid4.3UN2805II4.3A8, A19, A20, IB415121224115 kg50 kgE
    Lithium hydroxide, monohydrate or Lithium hydroxide, solid8UN2680II8IB8, IP2, IP415421224015 kg50 kgA
    Lithium hydroxide, solution8UN2679II8B2, IB2, T7, TP21542022421 L30 LA
    III8IB3, T4, TP21542032415 L60 LA96
    Lithium hypochlorite, dry with more than 39% available chlorine (8.8% available oxygen) or Lithium hypochlorite mixtures, dry with more than 39% available chlorine (8.8% available oxygen)5.1UN1471II5.1A9, IB8, IP2, IP4, N341522122405 kg25 kgA48, 56, 58, 69, 106, 116
    Lithium in cartridges, see Lithium
    Lithium nitrate5.1UN2722III5.1A1, IB8, IP315221324025 kg100 kgA
    Lithium nitride4.3UN2806I4.3A19, IB4, IP1, N40None211242Forbidden15 kgE
    Lithium peroxide5.1UN1472II5.1A9, IB6, IP2, N34152212None5 kg25 kgA13, 75, 106
    Lithium silicon4.3UN1417II4.3A19, A20, IB7, IP215121224115 kg50 kgA85, 103
    LNG, see Methane etc. (UN 1972)
    London purple6.1UN1621II6.1IB8, IP2, IP4None21224225 kg100 kgA
    LPG, see Petroleum gases, liquefied
    Lye, see Sodium hydroxide, solutions
    Magnesium alkyls4.2UN3053I4.2, 4.3B11, T21, TP2, TP7None181244ForbiddenForbiddenD18
    Magnesium aluminum phosphide4.3UN1419I4.3, 6.1A19, N34, N40None211242Forbidden15 kgE40, 85
    +Magnesium arsenate6.1UN1622II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Magnesium bisulfite solution, see Bisulfites, aqueous solutions, n.o.s.
    Magnesium bromate5.1UN1473II5.1A1, IB8, IP41522122425 kg25 kgA56, 58, 106
    Magnesium chlorate5.1UN2723II5.1IB8, IP2, IP41522122425 kg25 kgA56, 58, 106
    Magnesium diamide4.2UN2004II4.2A8, A19, A20, IB6None21224115 kg50 kgC
    Magnesium diphenyl4.2UN2005I4.2None187244ForbiddenForbiddenC
    Magnesium dross, wet or hotForbidden
    Magnesium fluorosilicate6.1UN2853III6.1IB8, IP3153213240100 kg200 kgA26
    Magnesium granules, coated, particle size not less than 149 microns4.3UN2950III4.3A1, A19, IB8, IP415121324025 kg100 kgA
    Magnesium hydride4.3UN2010I4.3A19, N40None211242Forbidden15 kgE
    Magnesium or Magnesium alloys with more than 50 percent magnesium in pellets, turnings or ribbons4.1UN1869III4.1A1, IB8, IP315121324025 kg100 kgA39
    Magnesium nitrate5.1UN1474III5.1A1, IB8, IP315221324025 kg100 kgA
    Magnesium perchlorate5.1UN1475II5.1IB6, IP21522122425 kg25 kgA56, 58, 106
    Magnesium peroxide5.1UN1476II5.1IB6, IP21522122425 kg25 kgA13, 75, 106
    Magnesium phosphide4.3UN2011I4.3, 6.1A19, N40None211NoneForbidden15 kgE40, 85
    Magnesium, powder or Magnesium alloys, powder4.3UN1418I4.3, 4.2A19, B56None211244Forbidden15 kgA39
    II4.3, 4.2A19, B56, IB5, IP2None21224115 kg50 kgA39
    III4.3, 4.2A19, B56, IB8, IP4None21324125 kg100 kgA39
    Magnesium scrap, see Magnesium, etc. (UN 1869)
    Start Printed Page 33380
    Magnesium silicide4.3UN2624II4.3A19, A20, IB7, IP215121224115 kg50 kgB85, 103
    Magnetized material, see § 173.21
    Maleic anhydride8UN2215III8IB8, IP3, T4, TP115421324025 kg100 kgA
    Malononitrile6.1UN2647II6.1IB8, IP2, IP4None21224225 kg100 kgA12
    Mancozeb (manganese ethylenebisdithiocarbamate complex with zinc) see Maneb
    Maneb or Maneb preparations with not less than 60 percent maneb4.2UN2210III4.2, 4.357, A1, A19, IB6None21324225 kg100 kgA34
    Maneb stabilized or Maneb preparations, stabilized against self-heating4.3UN2968III4.354, A1, A19, IB8, IP415121324225 kg100 kgB34
    Manganese nitrate5.1UN2724III5.1A1, IB8, IP315221324025 kg100 kgA
    Manganese resinate4.1UN1330III4.1A1, IB615121324025 kg100 kgA
    Mannitan tetranitrateForbidden
    Mannitol hexanitrate (dry)Forbidden
    Mannitol hexanitrate, wetted or Nitromannite, wetted with not less than 40 percent water, or mixture of alcohol and water, by mass1.1DUN0133II1.1D121None62NoneForbiddenForbidden10
    Marine pollutants, liquid or solid, n.o.s., see Environmentally hazardous substances, liquid or solid, n.o.s.
    Matches, block, see Matches, 'strike anywhere'
    Matches, fusee4.1UN2254III4.1186186NoneForbiddenForbiddenA
    Matches, safety (book, card or strike on box)4.1UN1944III4.1186186None25 kg100 kgA
    Matches, strike anywhere4.1UN1331III4.1186186NoneForbiddenForbiddenB
    Matches, wax, Vesta4.1UN1945III4.1186186None25 kg100 kgB
    Matting acid, see Sulfuric acid
    Medicine, liquid, flammable, toxic, n.o.s.3UN3248II3, 6.136, IB2None202None1 L5 LB40
    III3, 6.136, IB3150203None5 L5 LA
    Medicine, liquid, toxic, n.o.s.6.1UN1851II6.11532022435 L5 LC40
    III6.11532032415 L5 LC40
    Medicine, solid, toxic, n.o.s.6.1UN3249II6.136153212None5 kg5 kgC40
    III6.136153213None5 kg5 kgC40
    Memtetrahydrophthalic anhydride, see Corrosive liquids, n.o.s.
    Mercaptans, liquid, flammable, n.o.s. or Mercaptan mixture, liquid, flammable, n.o.s.3UN3336I3T11, TP21502012431 L30 LE95
    II3IB2, T7, TP1, TP8, TP281502022425 L60 LB95
    III3B1, B52, IB3, T4, TP1, TP2915020324160 L220 LB95
    Mercaptans, liquid, flammable, toxic, n.o.s. or Mercaptan mixtures, liquid, flammable, toxic, n.o.s.3UN1228II3, 6.1IB2, T11, TP2, TP27None202243Forbidden60 LB40, 95
    III3, 6.1B1, IB3, T7, TP1, TP281502032425 L220 LA40, 95
    Mercaptans, liquid, toxic, flammable, n.o.s. or Mercaptan mixtures, liquid, toxic, flammable, n.o.s. , flash point not less than 23 degrees C6.1UN3071II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LC40, 121
    5-Mercaptotetrazol-1-acetic acid1.4CUN0448II1.4CNone62NoneForbidden75 kg09
    Mercuric arsenate6.1UN1623II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercuric chloride6.1UN1624II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercuric compounds, see Mercury compounds, etc
    Mercuric nitrate6.1UN1625II6.1IB8, IP2, IP4, N73None21224225 kg100 kgA
    +Mercuric potassium cyanide6.1UN1626I6.1IB7, IP1, N74, N75None2112425 kg50 kgA26
    Mercuric sulfocyanate, see Mercury thiocyanate
    Mercurol, see Mercury nucleate
    Mercurous azideForbidden
    Mercurous compounds, see Mercury compounds, etc
    Mercurous nitrate6.1UN1627II6.1IB8, IP2, IP4None21224225 kg100 kgA
    A WMercury8UN2809III816416424035 kg35 kgB40, 97
    Mercury acetate6.1UN1629II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercury acetylideForbidden
    Mercury ammonium chloride6.1UN1630II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercury based pesticides, liquid, flammable, toxic , flash point less than 23 degrees C3UN2778I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Mercury based pesticides, liquid, toxic6.1UN3012I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    Start Printed Page 33381
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Mercury based pesticides, liquid, toxic, flammable, flash point not less than 23 degrees C6.1UN3011I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3IB3, T7, TP2, TP2815320324260 L220 LA40
    Mercury based pesticides, solid, toxic6.1UN2777I6.1IB7, IP1None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Mercury benzoate6.1UN1631II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercury bromides6.1UN1634II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercury compounds, liquid, n.o.s.6.1UN2024I6.1None2012431 L30 LB40
    II6.1IB2None2022435 L60 LB40
    III6.1IB315320324160 L220 LB40
    Mercury compounds, solid, n.o.s.6.1UN2025I6.1IB7, IP1None2112425 kg50 kgA
    II6.1IB8, IP2, IP4None21224225 kg100 kgA
    III6.1IB8, IP3153213240100 kg200 kgA
    AMercury contained in manufactured articles8UN2809III8None164NoneNo limitNo limitB40, 97
    Mercury cyanide6.1UN1636II6.1IB8, IP2, IP4, N74, N75None21224225 kg100 kgA26
    Mercury fulminate, wetted with not less than 20 percent water, or mixture of alcohol and water, by mass1.1AUN0135II1.1A111, 117None62NoneForbiddenForbidden12
    Mercury gluconate6.1UN1637II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercury iodide, solid6.1UN1638II6.1IB2, IP2, IP4None21224225 kg100 kgA
    Mercury iodide aquabasic ammonobasic (Iodide of Millon's base)Forbidden
    Mercury iodide, solution6.1UN1638II6.1IB8, IP2, IP4None2022435 L60 LA
    Mercury nitrideForbidden
    Mercury nucleate6.1UN1639II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercury oleate6.1UN1640II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercury oxide6.1UN1641II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercury oxycyanideForbidden
    Mercury oxycyanide, desensitized6.1UN1642II6.1IB8, IP2, IP4None21224225 kg100 kgA26, 91
    Mercury potassium iodide6.1UN1643II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercury salicylate6.1UN1644II6.1IB8, IP2, IP4None21224225 kg100 kgA
    +Mercury sulfates6.1UN1645II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mercury thiocyanate6.1UN1646II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Mesityl oxide3UN1229III3B1, IB3, T2, TP1None20324260 L220 LA
    Metal alkyl halides, water-reactive n.o.s. or Metal aryl halides, water-reactive, n.o.s.4.2UN3049I4.2, 4.3B9, B11, T21, TP2, TP7None181244ForbiddenForbiddenD
    Metal alkyl hydrides, water-reactive, n.o.s. or Metal aryl hydrides, water-reactive, n.o.s.4.2UN3050I4.2, 4.3B9, B11, T21, TP2, TP7None181244ForbiddenForbiddenD
    Metal alkyls, water-reactive, n.o.s. or Metal aryls, water-reactive n.o.s.4.2UN2003I4.2, 4.3B11, T21, TP2, TP7None181244ForbiddenForbiddenD
    Metal carbonyls, n.o.s.6.1UN3281I6.15, T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP1, TP2815320324160 L220 LA40
    Metal catalyst, dry4.2UN2881I4.2N34None187None25 kg100 kgC
    II4.2IB6, IP2, N34None187242Forbidden50 kgC
    III4.2IB8, IP3, N34None18724125 kg100 kgC
    Metal catalyst, wetted with a visible excess of liquid4.2UN1378II4.2A2, A8, IB1, N34None212NoneForbidden50 kgC
    Metal hydrides, flammable, n.o.s.4.1UN3182II4.1A1, IB415121224015 kg50 kgE
    III4.1A1, IB415121324025 kg100 kgE
    Metal hydrides, water reactive, n.o.s.4.3UN1409I4.3A19, N34, N40None211242Forbidden15 kgD
    II4.3A19, IB4, N34, N4015121224215 kg50 kgD
    Metal powder, self-heating, n.o.s.4.2UN3189II4.2IB6, IP2None21224115 kg50 kgC
    III4.2IB8, IP3None21324125 kg100 kgC
    Metal powders, flammable, n.o.s.4.1UN3089II4.1IB8, IP2, IP415121224015 kg50 kgB
    III4.1IB615121324025 kg100 kgB
    Metal salts of methyl nitramine (dry)Forbidden
    GMetal salts of organic compounds, flammable, n.o.s.4.1UN3181II4.1A1, IB8, IP2, IP415121224015 kg50 kgB40
    III4.1A1, IB8, IP315121324025 kg100 kgB40
    Metaldehyde4.1UN1332III4.1A1, IB8, IP315121324025 kg100 kgA
    GMetallic substance, water-reactive, n.o.s.4.3UN3208I4.3IB4None211242Forbidden15 kgE40
    II4.3IB7, IP215121224215 kg50 kgE40
    Start Printed Page 33382
    III4.3IB8, IP415121324125 kg100 kgE40
    GMetallic substance, water-reactive, self-heating, n.o.s.4.3UN3209I4.3, 4.2None211242Forbidden15 kgE40
    II4.3, 4.2IB5, IP2None21224215 kg50 kgE40
    III4.3, 4.2IB8, IP4None21324225 kg100 kgE40
    Methacrylaldehyde, stabilized3UN2396II3, 6.145, IB2, T7, TP1, TP13None2022431 L60 LE40
    Methacrylic acid, stabilized8UN2531II8IB3, T4, TP1, TP181542022421 L30 LA
    +Methacrylonitrile, stabilized3UN3079I3, 6.12, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD12, 40, 48
    Methallyl alcohol3UN2614III3B1, IB3, T2, TP115020324260 L220 LA
    Methane and hydrogen, mixtures, see Hydrogen and methane, mixtures, etc
    Methane, compressed or Natural gas, compressed (with high methane content)2.1UN19712.1306302302Forbidden150 kgE40
    Methane, refrigerated liquid (cryogenic liquid) or Natural gas, refrigerated liquid (cryogenic liquid), with high methane content)2.1UN19722.1T75, TP5NoneNone318ForbiddenForbiddenD40
    Methanesulfonyl chloride6.1UN3246I6.1, 82, 25, B9, B14, B32, B74, T20, TP2, TP12, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    + IMethanol3UN1230II3, 6.1IB2, T7, TP21502022421 L60 LB40
    DMethanol3UN1230II3IB2, T7, TP21502022421 L60 LB40
    Methazoic acidForbidden
    4-Methoxy-4-methylpentan-2-one3UN2293III3B1, IB3, T2, TP115020324260 L220 LA
    1-Methoxy-2-propanol3UN3092III3B1, IB3, T2, TP115020324260 L220 LA
    +Methoxymethyl isocyanate3UN2605I3, 6.11, B9, B14, B30, B72, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenD40
    Methyl acetate3UN1231II3IB2, T4, TP11502022425 L60 LB
    Methyl acetylene and propadiene mixtures, stabilized2.1UN10602.1T50306304314, 315Forbidden150 kgB40
    Methyl acrylate, stabilized3UN1919II3IB2, T4, TP1, TP131502022425 L60 LB
    Methyl alcohol, see Methanol
    Methyl allyl chloride3UN2554II3IB2, T4, TP1, TP131502022425 L60 LE
    Methyl amyl ketone, see Amyl methyl ketone
    Methyl bromide2.3UN10622.33, B14, T50None193314, 315Forbidden25 kgD40
    Methyl bromide and chloropicrin mixtures with more than 2 percent chloropicrin, see Chloropicrin and methyl bromide mixtures
    Methyl bromide and chloropicrin mixtures with not more than 2 percent chloropicrin, see Methyl bromide
    Methyl bromide and ethylene dibromide mixtures, liquid6.1UN1647I6.12, B9, B14, B32, B74, N65, T20, TP2, TP13, TP38, TP44None227244ForbiddenForbiddenC40
    Methyl bromoacetate6.1UN2643II6.1IB2, T7, TP2None2022435 L60 LD40
    2-Methyl-1-butene3UN2459I3T11, TP2None2012431 L30 LE
    2-Methyl-2-butene3UN2460II3IB2, IP8, T7, TP1None2022425 L60 LE
    3-Methyl-1-butene3UN2561I3T11, TP2None2012431 L30 LE
    Methyl tert-butyl ether3UN2398II3IB2, T7, TP11502022425 L60 LE
    Methyl butyrate3UN1237II3IB2, T4, TP11502022425 L60 LB
    Methyl chloride, or Refrigerant gas R 402.1UN10632.1T50306304314, 3155 kg100 kgD40
    Methyl chloride and chloropicrin mixtures, see Chloropicrin and methyl chloride mixtures
    Methyl chloride and methylene chloride mixtures2.1UN19122.1T50306304314, 315Forbidden150 kgD40
    Methyl chloroacetate6.1UN2295I6.1, 3T14, TP2, TP13None2012431 L30 LD
    Methyl chlorocarbonate, see Methyl chloroformate
    Methyl chloroform, see 1,1,1-Trichloroethane
    Methyl chloroformate6.1UN1238I6.1, 3, 81, B9, B14, B30, B72, N34, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenD21, 40, 100
    Methyl chloromethyl ether6.1UN1239I6.1, 31, B9, B14, B30, B72, T22, TP2, TP38, TP44None226244ForbiddenForbiddenD40
    Methyl 2-chloropropionate3UN2933III3B1, IB3, T2, TP115020324260 L220 LA
    Methyl dichloroacetate6.1UN2299III6.1IB3, T4, TP115320324160 L220 LA
    Start Printed Page 33383
    Methyl ethyl ether, see Ethyl methyl ether
    Methyl ethyl ketone, see Ethyl methyl ketone
    Methyl ethyl ketone peroxide, in solution with more than 9 percent by mass active oxygenForbidden
    2-Methyl-5-ethylpyridine6.1UN2300III6.1IB3, T4, TP115320324160 L220 LA
    Methyl fluoride, or Refrigerant gas R 412.1UN24542.1306304314, 315Forbidden150 kgE40
    Methyl formate3UN1243I3T11, TP21502012431 L30 LE
    2-Methyl-2-heptanethiol6.1UN3023I6.1, 32, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40, 102
    Methyl iodide6.1UN2644I6.12, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenA12, 40
    Methyl isobutyl carbinol3UN2053III3B1, IB3, T2, TP115020324260 L220 LA
    Methyl isobutyl ketone3UN1245II3IB2, T4, TP11502022425 L60 LB
    Methyl isobutyl ketone peroxide, in solution with more than 9 percent by mass active oxygenForbidden
    Methyl isocyanate6.1UN2480I6.1, 31, B9, B14, B30, B72, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenD26, 40
    Methyl isopropenyl ketone, stabilized3UN1246II3IB2, T4, TP11502022425 L60 LB
    Methyl isothiocyanate6.1UN2477I6.1, 32, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenA
    Methyl isovalerate3UN2400II3IB2, T4, TP11502022425 L60 LB
    Methyl magnesium bromide, in ethyl ether4.3UN1928I4.3, 3None201243Forbidden1 LD
    Methyl mercaptan2.3UN10642.3, 2.13, B7, B9, B14, T50None304314, 315Forbidden25 kgD40
    Methyl mercaptopropionaldehyde, see Thia-4-pentanal
    Methyl methacrylate monomer, stabilized3UN1247II3IB2, T4, TP11502022425 L60 LB40
    Methyl nitramine (dry)Forbidden
    Methyl nitrateForbidden
    Methyl nitriteForbidden
    Methyl norbornene dicarboxylic anhydride, see Corrosive liquids, n.o.s.
    Methyl orthosilicate6.1UN2606I6.1, 32, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenE40
    DMethyl phosphonic dichloride6.1NA9206I6.1, 82, A3, B9, B14, B32, B74, N34, N43, T20, TP4, TP12, TP13, TP38, TP45None227244ForbiddenForbiddenC
    Methyl phosphonothioic dichloride, anhydrous, see Corrosive liquid, n.o.s.
    DMethyl phosphonous dichloride, pyrophoric liquid6.1NA2845I6.1, 4.22, B9, B14, B16, B32, B74, T20, TP4, TP12, TP13, TP38, TP45None227244ForbiddenForbiddenD18
    Methyl picric acid (heavy metal salts of)Forbidden
    Methyl propionate3UN1248II3IB2, T4, TP11502022425 L60 LB
    Methyl propyl ether3UN2612II3IB2, IP8, T7, TP21502022425 L60 LE40
    Methyl propyl ketone3UN1249II3IB2, T4, TP11502022425 L60 LB
    Methyl sulfate, see Dimethyl sulfate
    Methyl sulfide, see Dimethyl sulfide
    Methyl trichloroacetate6.1UN2533III6.1IB3, T4, TP115320324160 L220 LA
    Methyl trimethylol methane trinitrateForbidden
    Methyl vinyl ketone, stabilized6.1UN1251I6.1, 3, 81, 25, B9, B14, B30, B72, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenB40
    Methylal3UN1234II3IB2, IP8, T7, TP2None2022425 L60 LE
    Methylamine, anhydrous2.1UN10612.1T50306304314, 315Forbidden150 kgB40
    Methylamine, aqueous solution3UN1235II3, 8B1, IB2, T7, TP11502022431 L5 LE41
    Methylamine dinitramine and dry salts thereofForbidden
    Methylamine nitroformForbidden
    Methylamine perchlorate (dry)Forbidden
    Methylamyl acetate3UN1233III3B1, IB3, T2, TP115020324260 L220 LA
    N-Methylaniline6.1UN2294III6.1IB3, T4, TP115320324160 L220 LA
    alpha-Methylbenzyl alcohol6.1UN2937III6.1IB3, T4, TP115320324160 L220 LA
    3-Methylbutan-2-one3UN2397II3IB2, T4, TP11502022425 L60 LB
    Start Printed Page 33384
    N-Methylbutylamine3UN2945II3, 8IB2, T7, TP1None2022431 L5 LB40
    Methylchlorosilane2.3UN25342.3, 2.1, 82, A2, A3, A7, B9, B14, N34None226314, 315ForbiddenForbiddenD17, 40
    Methylcyclohexane3UN2296II3B1, IB2, T4, TP11502022425 L60 LB
    Methylcyclohexanols, flammable3UN2617III3B1, IB3, T2, TP115020324260 L220 LA
    Methylcyclohexanone3UN2297III3B1, IB3, T2, TP115020324260 L220 LA
    Methylcyclopentane3UN2298II3IB2, T4, TP11502022425 L60 LB
    DMethyldichloroarsine6.1NA1556I6.12, T20, TP4, TP12, TP13, TP38, TP45None192NoneForbiddenForbiddenD40
    Methyldichlorosilane4.3UN1242I4.3, 8, 3A2, A3, A7, B6, B77, N34, T10, TP2, TP7, TP13None201243Forbidden1 LD21, 28, 40, 49, 100
    Methylene chloride, see Dichloromethane
    Methylene glycol dinitrateForbidden
    2-Methylfuran3UN2301II3IB2, T4, TP11502022425 L60 LE
    a-Methylglucoside tetranitrateForbidden
    a-Methylglycerol trinitrateForbidden
    5-Methylhexan-2-one3UN2302III3B1, IB3, T2, TP115020324260 L220 LA
    Methylhydrazine6.1UN1244I6.1, 3, 81, B7, B9, B14, B30, B72, B77, N34, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenD21, 40, 49, 100
    4-Methylmorpholine or n-methylmorpholine3UN2535II3, 8B6, IB2, T7, TP1None2022431 L5 LB40
    Methylpentadienes3UN2461II3IB2, T4, TP11502022425 L60 LE
    2-Methylpentan-2-ol3UN2560III3B1, IB3, T2, TP115020324260 L220 LA
    Methylpentanes, see Hexanes
    Methylphenyldichlorosilane8UN2437II8IB2, T7, TP2, TP131542022421 L30 LC40
    1-Methylpiperidine3UN2399II3, 8IB2, T7, TP1None2022431 L5 LB
    Methyltetrahydrofuran3UN2536II3IB2, T4, TP11502022425 L60 LB
    Methyltrichlorosilane3UN1250I3, 8A7, B6, B77, N34, T11, TP2, TP13None201243Forbidden2.5 LB40
    alpha-Methylvaleraldehyde3UN2367II3B1, IB2, T4, TP11502022425 L60 LB
    Mine rescue equipment containing carbon dioxide, see Carbon dioxide
    Mines with bursting charge1.1FUN0136II1.1F62NoneForbiddenForbidden08
    Mines with bursting charge1.1DUN0137II1.1D62NoneForbiddenForbidden03
    Mines with bursting charge1.2DUN0138II1.2D62NoneForbiddenForbidden03
    Mines with bursting charge1.2FUN0294II1.2F62NoneForbiddenForbidden08
    Mixed acid, see Nitrating acid, mixtures etc
    Mobility aids, see Battery powered equipment or Battery powered vehicle'
    DModel rocket motor1.4CNA0276II1.4C51None62NoneForbidden75 kg06
    DModel rocket motor1.4SNA0323II1.4S51None62None25 kg100 kg05
    Molybdenum pentachloride8UN2508III8IB8, IP3, T4, TP115421324025 kg100 kgC40
    Monochloroacetone (unstabilized)Forbidden
    Monochloroethylene, see Vinyl chloride, stabilized
    Monoethanolamine, see Ethanolamine, solutions
    Monoethylamine, see Ethylamine
    Morpholine8UN2054I8, 3T10, TP2None201243.5 L2.5 LC25,40
    Morpholine, aqueous, mixture, see Corrosive liquids, n.o.s.
    Motor fuel anti-knock compounds see Motor fuel anti-knock mixtures
    +Motor fuel anti-knock mixtures6.1UN1649I6.1, 314, B9, B90, T14, TP2, TP13None201244Forbidden30 LD25, 40
    Motor spirit, see Gasoline
    Muriatic acid, see Hydrochloric acid
    Musk xylene, see 5-tert-Butyl-2,4,6-trinitro-m-xylene
    Naphtha see Petroleum distillates n.o.s.
    Naphthalene, crude or Naphthalene, refined4.1UN1334III4.1A1, IB8, IP315121324025 kg100 kgA
    Naphthalene diozonideForbidden
    beta-Naphthylamine6.1UN1650II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA
    alpha-Naphthylamine6.1UN2077III6.1IB8, IP3, T3, TP1153213240100 kg200 kgA
    Naphthalene, molten4.1UN2304III4.1A1, IB1, T1, TP3151213241ForbiddenForbiddenC
    NaphthylamineperchlorateForbidden
    Naphthylthiourea6.1UN1651II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Naphthylurea6.1UN1652II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Natural gases (with high methane content), see Methane, etc. (UN 1971, UN 1972)
    Neohexane, see Hexanes
    Start Printed Page 33385
    Neon, compressed2.2UN10652.230630230275 kg150 kgA
    Neon, refrigerated liquid (cryogenic liquid)2.2UN19132.2T75, TP5320316None50 kg500 kgB
    New explosive or explosive device, see §§ 173.51 and 173.56
    Nickel carbonyl6.1UN1259I6.1, 31None198NoneForbiddenForbiddenD18, 40
    Nickel cyanide6.1UN1653II6.1IB8, IP2, IP4, N74, N75None21224225 kg100 kgA26
    Nickel nitrate5.1UN2725III5.1A1, IB8, IP315221324025 kg100 kgA
    Nickel nitrite5.1UN2726III5.1A1, IB8, IP315221324025 kg100 kgA56, 58
    Nickel picrateForbidden
    Nicotine6.1UN1654II6.1IB2None2022435 L60 LA
    Nicotine compounds, liquid, n.o.s. or Nicotine preparations, liquid, n.o.s.6.1UN3144I6.1A4None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP1, TP2815320324160 L220 LB40
    Nicotine compounds, solid, n.o.s. or Nicotine preparations, solid, n.o.s.6.1UN1655I6.1IB7, IP1None2112425 kg50 kgB
    II6.1IB8, IP2, IP4None21224225 kg100 kgA
    III6.1IB8, IP3153213240100 kg200 kgA
    Nicotine hydrochloride or Nicotine hydrochloride solution6.1UN1656II6.1IB2, IP2, IP4None2022435 L60 LA
    Nicotine salicylate6.1UN1657II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Nicotine sulfate, solid6.1UN1658II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Nicotine sulfate, solution6.1UN1658II6.1IB2, T7, TP2None2022435 L60 LA
    Nicotine tartrate6.1UN1659II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Nitrated paper (unstable)Forbidden
    Nitrates, inorganic, aqueous solution, n.o.s.5.1UN3218II5.158, IB2, T4, TP11522022421 L5 LB46
    III5.158, IB2, T4, TP11522032412.5 L30 LB46
    Nitrates, inorganic, n.o.s.5.1UN1477II5.1IB8, IP2, IP41522122405 kg25 kgA46
    III5.1IB8, IP315221324025 kg100 kgA46
    Nitrates of diazonium compoundsForbidden
    Nitrating acid mixtures, spent with more than 50 percent nitric acid8UN1826I8, 5.1T10, TP2, TP12, TP13None158243Forbidden2.5 LD40, 66
    Nitrating acid mixtures spent with not more than 50 percent nitric acid8UN1826II8B2, IB2, T8, TP2, TP12None158242Forbidden30 LD40
    Nitrating acid mixtures with more than 50 percent nitric acid8UN1796I8, 5.1T10, TP2, TP12, TP13None158243Forbidden2.5 LD40, 66
    Nitrating acid mixtures with not more than 50 percent nitric acid8UN1796II8B2, IB2, T8, TP2, TP12, TP13None158242Forbidden30 LD40
    Nitric acid other than red fuming, with more than 70 percent nitric acid8UN2031I8, 5.1B47, B53, T10, TP2, TP12, TP13None158243Forbidden2.5 LD44, 66, 89, 90, 110, 111
    Nitric acid other than red fuming, with not more than 70 percent nitric acid8UN2031II8B2, B47, B53, IB2, T8, TP2, TP12None158242Forbidden30 LD44, 66, 89, 90, 110, 111
    +Nitric acid, red fuming8UN2032I8, 5.1, 6.12, B9, B32, B74, T20, TP2, TP12, TP13, TP38, TP45None227244ForbiddenForbiddenD40, 66, 74, 89, 90
    Nitric oxide, compressed2.3UN16602.3, 5.1, 81, B37, B46, B50, B60, B77None337NoneForbiddenForbiddenD40, 89, 90
    Nitric oxide and dinitrogen tetroxide mixtures or Nitric oxide and nitrogen dioxide mixtures2.3UN19752.3, 5.1, 81, B7, B9, B14, B45, B46, B61, B66, B67, B77None337NoneForbiddenForbiddenD40, 89, 90
    GNitriles, flammable, toxic, n.o.s.3UN3273I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LE40, 52
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40, 52
    GNitriles, toxic, flammable, n.o.s.6.1UN3275I6.1, 35, T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    GNitriles, toxic, n.o.s.6.1UN3276I6.15, T14, TP2, TP13, TP27None2012431 L30 LB
    II6.1IB2, T11, TP2, TP27None2022435 L60 LB
    III6.1IB3, T7, TP1, TP2815320324160 L220 LA
    Nitrites, inorganic, aqueous solution, n.o.s.5.1UN3219II5.1IB1, T4, TP11522022421 L5 LB46, 56, 58
    III5.1IB2, T4, TP11522032412.5 L30 LB46, 56, 58
    Nitrites, inorganic, n.o.s.5.1UN2627II5.133, IB8, IP4152212None5 kg25 kgA46, 56, 58
    3-Nitro-4-chlorobenzotrifluoride6.1UN2307II6.1IB2, T7, TP2None2022435 L60 LA40
    6-Nitro-4-diazotoluene-3-sulfonic acid (dry)Forbidden
    Nitro isobutane triol trinitrateForbidden
    Start Printed Page 33386
    N-Nitro-N-methylglycolamide nitrateForbidden
    2-Nitro-2-methylpropanol nitrateForbidden
    Nitro urea1.1DUN0147II1.1DNone62NoneForbiddenForbidden10
    N-NitroanilineForbidden
    +Nitroanilines (o-; m-; p-;)6.1UN1661II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA
    +Nitroanisole6.1UN2730III6.1IB8, IP3, T4, TP1153213240100 kg200 kgA
    +Nitrobenzene6.1UN1662II6.1IB2, T7, TP2None2022435 L60 LA40
    m-Nitrobenzene diazonium perchlorateForbidden
    Nitrobenzenesulfonic acid8UN2305II8IB21542022421 L30 LA
    Nitrobenzol, see Nitrobenzene
    5-Nitrobenzotriazol1.1DUN0385II1.1DNone62NoneForbiddenForbidden10
    Nitrobenzotrifluorides6.1UN2306II6.1IB2, T7, TP2None2022435 L60 LA40
    Nitrobromobenzenes liquid6.1UN2732III6.1IB3, T4, TP115320324160 L220 LA
    Nitrobromobenzenes solid6.1UN2732III6.1IB8, IP3, T4, TP1153213240100 kg200 kgA
    Nitrocellulose, dry or wetted with less than 25 percent water (or alcohol), by mass1.1DUN0340II1.1DNone62NoneForbiddenForbidden1327E
    Nitrocellulose membrane filters, with not more than 12.6% nitrogen, by dry mass4.1UN3270II4.143, A11512122401 kg15 kgD
    Nitrocellulose, plasticized with not less than 18 percent plasticizing substance, by mass1.3CUN0343II1.3CNone62NoneForbiddenForbidden10
    Nitrocellulose, solution, flammable with not more than 12.6 percent nitrogen, by mass, and not more than 55 percent nitrocellulose3UN2059II3IB2, T4, TP1, TP81502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Nitrocellulose, unmodified or plasticized with less than 18 percent plasticizing substance, by mass1.1DUN0341II1.1DNone62NoneForbiddenForbidden1327E
    Nitrocellulose, wetted with not less than 25 percent alcohol, by mass1.3CUN0342II1.3CNone62NoneForbiddenForbidden10
    Nitrocellulose with alcohol with not less than 25 percent alcohol by mass, and with not more than 12.6 percent nitrogen, by dry mass4.1UN2556II4.1151212None1 kg15 kgD28
    Nitrocellulose, with not more than 12.6 percent nitrogen, by dry mass, or Nitrocellulose mixture with pigment or Nitrocellulose mixture with plasticizer or Nitrocellulose mixture with pigment and plasticizer4.1UN2557II4.144151212None1 kg15 kgD28
    Nitrocellulose with water with not less than 25 percent water, by mass4.1UN2555II4.1151212None15 kg50 kgE28
    Nitrochlorobenzene, see Chloronitrobenzenes etc
    Nitrocresols6.1UN2446III6.1IB8, IP3153213240100 kg200 kgA
    Nitroethane3UN2842III3B1, IB3, T2, TP115020324260 L220 LA
    Nitroethyl nitrateForbidden
    Nitroethylene polymerForbidden
    Nitrogen, compressed2.2UN10662.2306302314, 31575 kg150 kgA
    Nitrogen dioxide, see Dinitrogen tetroxide
    Nitrogen fertilizer solution, see Fertilizer ammoniating solution etc
    Nitrogen, mixtures with rare gases, see Rare gases and nitrogen mixtures
    Nitrogen peroxide, see Dinitrogen tetroxide
    Nitrogen, refrigerated liquid cryogenic liquid2.2UN19772.2T75, TP532031631850 kg500 kgD
    Nitrogen tetroxide and nitric oxide mixtures, see Nitric oxide and nitrogen tetroxide mixtures
    Nitrogen tetroxide, see Dinitrogen tetroxide
    Nitrogen trichlorideForbidden
    Nitrogen trifluoride, compressed2.2UN24512.2, 5.1None302None75 kg150 kgD40
    Nitrogen triiodideForbidden
    Nitrogen triiodide monoamineForbidden
    Nitrogen trioxide2.3UN24212.3, 5.1, 81None336245ForbiddenForbiddenD40, 89, 90
    Start Printed Page 33387
    Nitroglycerin, desensitized with not less than 40 percent non-volatile water insoluble phlegmatizer, by mass1.1DUN0143II1.1D, 6.1125None62NoneForbiddenForbidden1321E
    Nitroglycerin, liquid, not desensitizedForbidden
    Nitroglycerin mixture, desensitized, liquid, flammable, n.o.s. with not more than 30 percent nitroglycerin, by mass3UN33433129None214NoneForbiddenForbiddenD
    Nitroglycerin mixture, desensitized, liquid, n.o.s. with not more than 30% nitroglycerin, by mass3UN3357II3142None2022435 L60 LE
    Nitroglycerin mixture, desensitized, solid, n.o.s. with more than 2 percent but not more than 10 percent nitroglycerin, by mass4.1UN3319II4.1118NoneNoneNoneForbidden0.5 kgE
    Nitroglycerin, solution in alcohol, with more than 1 percent but not more than 5 percent nitroglycerin3UN3064II3N8None202NoneForbidden5 LE
    Nitroglycerin, solution in alcohol, with more than 1 percent but not more than 10 percent nitrogylcerin1.1DUN0144II1.1DNone62NoneForbiddenForbidden1021E
    Nitroglycerin solution in alcohol with not more than 1 percent nitroglycerin3UN1204II3IB2, N34None202None5 L60 LB
    Nitroguanidine nitrateForbidden
    Nitroguanidine or Picrite, dry or wetted with less than 20 percent water, by mass1.1DUN0282II1.1DNone62NoneForbiddenForbidden10
    Nitroguanidine, wetted or Picrite, wetted with not less than 20 percent water, by mass4.1UN1336I4.123, A8, A19, A20, N41None211None1 kg15 kgE28
    1-NitrohydantoinForbidden
    Nitrohydrochloric acid8UN1798I8A3, B10, N41, T10, TP2, TP12, TP13None201243Forbidden2.5 LD40, 66, 74, 89, 90
    Nitromannite (dry)Forbidden
    Nitromannite, wetted, see Mannitol hexanitrate, etc
    Nitromethane3UN1261II3150202NoneForbiddenForbiddenA
    Nitromuriatic acid, see Nitrohydrochloric acid
    Nitronaphthalene4.1UN2538III4.1A1, IB8, IP315121324025 kg100 kgA
    +Nitrophenols (o-; m-; p-;)6.1UN1663III6.1IB8, IP3, T4, TP3153213240100 kg200 kgA
    m-Nitrophenyldinitro methaneForbidden
    Nitropropanes3UN2608III3B1, IB3, T2, TP115020324260 L220 LA
    p-Nitrosodimethylaniline4.2UN1369II4.2A19, A20, IB6, IP2, N34None21224115 kg50 kgD34
    Nitrostarch, dry or wetted with less than 20 percent water, by mass1.1DUN0146II1.1DNone62NoneForbiddenForbidden10
    Nitrostarch, wetted with not less than 20 percent water, by mass4.1UN1337I4.123, A8, A19, A20, N41None211None1 kg15 kgD28
    Nitrosugars (dry)Forbidden
    Nitrosyl chloride2.3UN10692.3, 83, B14None304314, 315ForbiddenForbiddenD40
    Nitrosylsulfuric acid8UN2308II8A3, A6, A7, B2, IB2, N34, T8, TP2, TP121542022421 L30 LD40, 66, 74, 89, 90
    Nitrotoluenes, liquid o-; m-; p-;6.1UN1664II6.1IB2, IP2, IP4, T7, TP2None2022435 L60 LA
    Nitrotoluenes, solid m-, or p-6.1UN1664II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA
    Nitrotoluidines (mono)6.1UN2660III6.1IB8, IP3153213240100 kg200 kgA
    Nitrotriazolone or NTO1.1DUN0490II1.1DNone62NoneForbiddenForbidden10
    Nitrous oxide and carbon dioxide mixtures, see Carbon dioxide and nitrous oxide mixtures
    Nitrous oxide2.2UN10702.2, 5.1306304314, 31575 kg150 kgA40
    Nitrous oxide, refrigerated liquid2.2UN22012.2, 5.1B6, T75, TP5, TP22None304314, 315ForbiddenForbiddenB40
    Nitroxylenes, (o-; m-; p-)6.1UN1665II6.1IB2, IP2, IP4, T7, TP2None2022435 L60 LA
    Nitroxylol, see Nitroxylenes
    Nonanes3UN1920III3B1, IB3, T2, TP115020324260 L220 LA
    Non-flammable gas, n.o.s., see Compressed gas, etc. or Liquefied gas, etc
    Nonliquefied gases, see Compressed gases, etc
    Nonliquefied hydrocarbon gas, see Hydrocarbon gas mixture, compressed, n.o.s.
    Start Printed Page 33388
    Nonyltrichlorosilane8UN1799II8A7, B2, B6, IB2, N34, T7, TP2, TP13None202242Forbidden30 LC40
    Nordhausen acid, see Sulfuric acid, fuming etc
    2,5-Norbornadiene, stabilized, see Bicyclo 2,2,1 hepta-2,5-diene stabilized
    Octadecyltrichlorosilane8UN1800II8A7, B2, B6, IB2, N34, T7, TP2, TP13None202242Forbidden30 LC40
    Octadiene3UN2309II3B1, IB2, T4, TP11502022425 L60 LB
    1,7-Octadine-3,5-diyne-1,8-dimethoxy-9-octadecynoic acidForbidden
    Octafluorobut-2-ene or Refrigerant gas R 13182.2UN24222.2None304314, 31575 kg150 kgA
    Octafluorocyclobutane, or Refrigerant gas RC 13182.2UN19762.2T50None304314, 31575 kg150 kgA
    Octafluoropropane or Refrigerant gas R 2182.2UN24242.2T50None304314, 31575 kg150 kgA
    Octanes3UN1262II3IB2, T4, TP11502022425 L60 LB
    Octogen, etc. see Cyclotetramethylene tetranitramine, etc.
    Octolite or Octol, dry or wetted with less than 15 percent water, by mass1.1DUN0266II1.1DNone62NoneForbiddenForbidden10
    Octonal1.1DUN04961.1DNone62NoneForbiddenForbidden10
    Octyl aldehydes3UN1191III3B1, IB3, T2, TP115020324260 L220 LA
    Octyltrichlorosilane8UN1801II8A7, B2, B6, IB2, N34, T7, TP2, TP13None202242Forbidden30 LC40
    Oil gas, compressed2.3UN10712.3, 2.16None304314, 315Forbidden25 kgD40
    Oleum, see Sulfuric acid, fuming
    Organic peroxide type A, liquid or solidForbidden
    GOrganic peroxide type B, liquid5.2UN3101II5.2, 153152225NoneForbiddenForbiddenD12, 40
    GOrganic peroxide type B, liquid, temperature controlled5.2UN3111II5.2, 153None225NoneForbiddenForbiddenD2, 40
    GOrganic peroxide type B, solid5.2UN3102II5.2, 153152225NoneForbiddenForbiddenD12, 40
    GOrganic peroxide type B, solid, temperature controlled5.2UN3112II5.2, 153None225NoneForbiddenForbiddenD2, 40
    GOrganic peroxide type C, liquid5.2UN3103II5.2152225None5 L10 LD12, 40
    GOrganic peroxide type C, liquid, temperature controlled5.2UN3113II5.2None225NoneForbiddenForbiddenD2, 40
    GOrganic peroxide type C, solid5.2UN3104II5.2152225None5 kg10 kgD12, 40
    GOrganic peroxide type C, solid, temperature controlled5.2UN3114II5.2None225NoneForbiddenForbiddenD2, 40
    GOrganic peroxide type D, liquid5.2UN3105II5.2152225None5 L10 LD12, 40
    GOrganic peroxide type D, liquid, temperature controlled5.2UN3115II5.2None225NoneForbiddenForbiddenD2, 40
    GOrganic peroxide type D, solid5.2UN3106II5.2152225None5 kg10 kgD12, 40
    GOrganic peroxide type D, solid, temperature controlled5.2UN3116II5.2None225NoneForbiddenForbiddenD2, 40
    GOrganic peroxide type E, liquid5.2UN3107II5.2152225None10 L25 LD12, 40
    GOrganic peroxide type E, liquid, temperature controlled5.2UN3117II5.2None225NoneForbiddenForbiddenD2, 40
    GOrganic peroxide type E, solid5.2UN3108II5.2152225None10 kg25 kgD12, 40
    GOrganic peroxide type E, solid, temperature controlled5.2UN3118II5.2None225NoneForbiddenForbiddenD2, 40
    GOrganic peroxide type F, liquid5.2UN3109II5.2IB52, IP5, T2315222522510 L25 LD12, 40
    GOrganic peroxide type F, liquid, temperature controlled5.2UN3119II5.2IB52, IP5, T23None225225ForbiddenForbiddenD2, 40
    GOrganic peroxide type F, solid5.2UN3110II5.2IB52, T2315222522510 kg25 kgD12, 40
    GOrganic peroxide type F, solid, temperature controlled5.2UN3120II5.2T23None225225ForbiddenForbiddenD2, 40
    DOrganic phosphate, mixed with compressed gas or Organic phosphate compound, mixed with compressed gas or Organic phosphorus compound, mixed with compressed gas2.3NA19552.33None334NoneForbiddenForbiddenD40
    Organic pigments, self-heating4.2UN3313II4.2IB8, IP4None21224115 kg50 kgC
    III4.2IB8, IP3None21324125 kg100 kgC
    Organoarsenic compound, n.o.s.6.1UN3280I6.15, IB7, IP1, T14, TP2, TP27None2112425 kg50 kgB
    II6.1IB8, IP2, IP4, T11, TP2, TP27None21224225 kg100 kgB
    III6.1IB8, IP3, T7, TP1, TP28153213240100 kg200 kgA
    Organochlorine pesticides liquid, flammable, toxic , flash point less than 23 degrees C3UN2762I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Organochlorine pesticides, liquid, toxic6.1UN2996I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    Start Printed Page 33389
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Organochlorine pesticides, liquid, toxic, flammable, flash point not less than 23 degrees C6.1UN2995I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1B1, IB3, T7, TP2, TP2815320324260 L220 LA40
    Organochlorine pesticides, solid toxic6.1UN2761I6.1IB7, IP1None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    GOrganometallic compound or Compound solution or Compound dispersion, water-reactive, flammable, n.o.s.4.3UN3207I4.3, 3T13, TP2, TP7None201244Forbidden1 LE40
    II4.3, 3IB1, IP2, T7, TP2, TP7None2022431 L5 LE40
    III4.3, 3IB2, IP4, T7, TP2, TP7None2032425 L60 LE40
    GOrganometallic compound, toxic n.o.s.6.1UN3282I6.1IB7, IP1, T14, TP2, TP27None2112425 kg50 kgB
    II6.1IB8, IP2, IP4, T11, TP2, TP27None21224225 kg100 kgB
    III6.1IB8, IP3, T7, TP1, TP28153213240100 kg200 kgA
    Organophosphorus compound, toxic, flammable, n.o.s.6.1UN3279I6.1, 35, T14, TP2, TP13None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    Organophosphorus compound, toxic n.o.s.6.1UN3278I6.15, IB7, T14, TP2, TP13, TP27None2012431 L30 LB
    II6.1IB2, T11, TP2, TP27None2022435 L60 LB
    III6.1IB3, T7, TP1, TP2815320324160 L220 LA
    Organophosphorus pesticides, liquid, flammable, toxic , flash point less than 23 degrees C3UN2784I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Organophosphorus pesticides, liquid, toxic6.1UN3018I6.1N76, T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, N76, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, N76, T7, TP2, TP2815320324160 L220 LA40
    Organophosphorus pesticides, liquid, toxic, flammable, flash point not less than 23 degrees C6.1UN3017I6.1, 3N76, T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, N76, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3B1, IB3, N76, T7, TP2, TP2815320324260 L220 LA40
    Organophosphorus pesticides, solid, toxic6.1UN2783I6.1IB7, IP1, N77None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4, N77None21224225 kg100 kgA40
    III6.1IB8, IP3, N77153213240100 kg200 kgA40
    Organotin compounds, liquid, n.o.s.6.1UN2788I6.1A3, N33, N34, T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1A3, IB2, N33, N34, T11, TP2, TP13, TP27None2022435 L60 LA40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Organotin compounds, solid, n.o.s.6.1UN3146I6.1A5, IB7, IP1None2112425 kg50 kgB40
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Organotin pesticides, liquid, flammable, toxic , flash point less than 23 degrees C3UN2787I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Organotin pesticides, liquid, toxic6.1UN3020I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Start Printed Page 33390
    Organotin pesticides, liquid, toxic, flammable, flash point not less than 23 degrees C6.1UN3019I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3B1, IB3, T7, TP2, TP2815320324260 L220 LA40
    Organotin pesticides, solid, toxic6.1UN2786I6.1IB7, IP1None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Orthonitroaniline, see Nitroanilines etc
    Osmium tetroxide6.1UN2471I6.1A8, IB7, IP1, N33, N34None2112425 kg50 kgB40
    D GOther regulated substances, liquid, n.o.s.9NA3082III9IB3, T2, TP1155203241No limitNo limitA
    D GOther regulated substances, solid, n.o.s.9NA3077III9B54, IB8, IP2155213240No limitNo limitA
    GOxidizing liquid, corrosive, n.o.s.5.1UN3098I5.1, 8None201244Forbidden2.5 LD13, 56, 58, 69, 106
    II5.1, 8IB1None2022431 L5 LB34, 56, 58, 69, 106
    III5.1, 8IB21522032422.5 L30 LB34, 56, 58, 69, 106
    GOxidizing liquid, n.o.s.5.1UN3139I5.1127, A2None201243Forbidden2.5 LD56, 58, 69, 106
    II5.1127, A2, IB21522022421 L5 LB56, 58, 69, 106
    III5.1127, A2, IB21522032412.5 L30 LB56, 58, 69, 106
    GOxidizing liquid, toxic, n.o.s.5.1UN3099I5.1, 6.1None201244Forbidden2.5 LD56, 58, 69, 106
    II5.1, 6.1IB1None2022431 L5 LB56, 58, 95, 106
    III5.1, 6.1IB21522032422.5 L30 LB56, 58, 95, 106
    GOxidizing solid, corrosive, n.o.s.5.1UN3085I5.1, 8None2112421 kg15 kgD13, 56, 58, 69, 106
    II5.1, 8IB6, IP2None2122425 kg25 kgB13, 34, 56, 58, 69, 106
    III5.1, 8IB8, IP315221324025 kg100 kgB13, 34, 56, 58, 69, 106
    GOxidizing solid, flammable, n.o.s.5.1UN3137I5.1, 4.1None214214ForbiddenForbidden
    GOxidizing solid, n.o.s.5.1UN1479I5.1IB6, IP1None2112421 kg15 kgD56, 58, 69, 106
    II5.1IB8, IP2, IP41522122405 kg25 kgB56, 58, 69, 106
    III5.1IB8, IP315221324025 kg100 kgB56, 58, 69, 106
    GOxidizing solid, self-heating, n.o.s.5.1UN3100II5.1, 4.2None214214ForbiddenForbidden
    GOxidizing solid, toxic, n.o.s.5.1UN3087I5.1, 6.1None2112421 kg15 kgD56, 58, 69, 106
    II5.1, 6.1IB6, IP2None2122425 kg25 kgB56, 58, 69, 95, 106
    III5.1, 6.1IB8, IP315221324025 kg100 kgB56, 58, 69, 95, 106
    GOxidizing solid, water-reactive, n.o.s.5.1UN31215.1, 4.3None214214ForbiddenForbidden
    Oxygen and carbon dioxide mixtures, see Carbon dioxide and oxygen mixtures
    Oxygen, compressed2.2UN10722.2, 5.1A52306302314, 31575 kg150 kgA
    Oxygen difluoride, compressed2.3UN21902.3, 5.1, 81None304NoneForbiddenForbiddenD13, 40, 89, 90
    Oxygen generator, chemical (including when contained in associated equipment, e.g., passenger service units (PSUs), portable breathing equipment (PBE), etc).5.1UN3356II5.160, A51None212NoneForbidden25 kg grossD56, 58, 69, 106
    +Oxygen generator, chemical, spent9NA3356III961None213NoneForbiddenForbiddenA
    Oxygen, mixtures with rare gases, see Rare gases and oxygen mixtures
    Oxygen, refrigerated liquid (cryogenic liquid)2.2UN10732.2, 5.1T75, TP5, TP22320316318ForbiddenForbiddenD
    Start Printed Page 33391
    Paint including paint, lacquer, enamel, stain, shellac solutions, varnish, polish, liquid filler, and liquid lacquer base3UN1263I3T11, TP1, TP81502012431 L30 LE
    II3B52, IB2, T4, TP1, TP81501732425 L60 LB
    III3B1, B52, IB3, T2, TP115017324260 L220 LA
    Paint or Paint related material8UN3066II8B2, IB2, T7, TP21541732421 L30 LA
    III8B52, IB3, T4, TP11541732415 L60 LA
    Paint related material including paint thinning, drying, removing, or reducing compound3UN1263I3T11, TP1, TP81502012431 L30 LE
    II3B52, IB2, T4, TP1, TP81501732425 L60 LB
    III3B1, B52, IB3, T2, TP115017324260 L220 LA
    Paper, unsaturated oil treated incompletely dried (including carbon paper)4.2UN1379III4.2IB8, IP3None213241ForbiddenForbiddenA
    Paraformaldehyde4.1UN2213III4.1A1, IB8, IP315121324025 kg100 kgA
    Paraldehyde3UN1264III3B1, IB3, T2, TP115020324260 L220 LA
    Paranitroaniline, solid, see Nitroanilines etc
    DParathion and compressed gas mixture2.3NA19672.33None334245ForbiddenForbiddenE40
    Paris green, solid, see Copper acetoarsenite
    A WPCB, see Polychlorinated biphenyls
    +Pentaborane4.2UN1380I4.2, 6.11None205245ForbiddenForbiddenD
    Pentachloroethane6.1UN1669II6.1IB2, T7, TP2None2022435 L60 LA40
    Pentachlorophenol6.1UN3155II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Pentaerythrite tetranitrate (dry)Forbidden
    Pentaerythrite tetranitrate mixture, desensitized, solid, n.o.s. with more than 10 percent but not more than 20 percent PETN, by mass4.1UN3344II4.1118None214NoneForbiddenForbiddenE40
    Pentaerythrite tetranitrate or Pentaerythritol tetranitrate or PETN, with not less than 7 percent wax by mass1.1DUN0411II1.1DNone62NoneForbiddenForbidden10
    Pentaerythrite tetranitrate, wetted or Pentaerythritol tetranitrate, wetted, or PETN, wetted with not less than 25 percent water, by mass, or Pentaerythrite tetranitrate, or Pentaerythritol tetranitrate or PETN, desensitized with not less than 15 percent phlegmatizer by mass1.1DUN0150II1.1D121None62NoneForbiddenForbidden10
    Pentaerythritol tetranitrate, see Pentaerythrite tetranitrate, etc
    Pentafluoroethane or Refrigerant gas R 1252.2UN32202.2T50306304314, 31575 kg150 kgA
    Pentamethylheptane3UN2286III3B1, IB3, T2, TP115020324260 L220 LA
    Pentane-2,4-dione3UN2310III3, 6.1B1, IB3, T4, TP115020324260 L220 LA
    Pentanes3UN1265I3T11, TP21502012431 L30 LE
    II3IB2, IP8, T4, TP11502022425 L60 LE
    Pentanitroaniline (dry)Forbidden
    Pentanols3UN1105II3IB2, T4, TP1, TP291502022425 L60 LB
    III3B1, B3, IB3, T2, TP115020324260 L220 LA
    1-Pentene (n-amylene)3UN1108I3T11, TP21502012431 L30 LE
    1-Pentol8UN2705II8B2, IB2, T7, TP21542022421 L30 LB38
    Pentolite, dry or wetted with less than 15 percent water, by mass1.1DUN0151II1.1DNone62NoneForbiddenForbidden10
    Pepper spray, see Aerosols, etc. or Self-defense spray, non-pressurized
    Perchlorates, inorganic, aqueous solution, n.o.s.5.1UN3211II5.1IB2, T4, TP11522022421 L5 LB46, 56, 58
    III5.1IB2, T4, TP11522022412.5 L30 LB56, 58, 69, 106
    Pepper spray, see Aerosols, etc. or Self-defense spray, non-pressurizedIII5.11522032412.5 L30 LB56, 58, 69, 106
    Perchlorates, inorganic, n.o.s.5.1UN1481II5.1IB6, IP21522122425 kg25 kgA46, 56
    III5.1IB8, IP315221324025 kg100 kgA46, 56
    Perchloric acid, with more than 72 percent acid by massForbidden
    Perchloric acid with more than 50 percent but not more than 72 percent acid, by mass5.1UN1873I5.1, 8A2, A3, N41, T10, TP1, TP12None201243Forbidden2.5 LD66
    Start Printed Page 33392
    Perchloric acid with not more than 50 percent acid by mass8UN1802II8, 5.1IB2, N41, T7, TP2None202243Forbidden30 LC66
    Perchloroethylene, see Tetrachloroethylene
    Perchloromethyl mercaptan6.1UN1670I6.12, A3, A7, B9, B14, B32, B74, N34, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Perchloryl fluoride2.3UN30832.3, 5.12, B9, B14None302314, 315ForbiddenForbiddenD40
    Percussion caps, see Primers, cap type
    Perfluoro-2-butene, see Octafluorobut-2-ene
    Perfluoro(ethyl vinyl ether)2.1UN31542.1306302, 304, 305314, 315Forbidden150 kgE40
    Perfluoro(methyl vinyl ether)2.1UN31532.1T50306302, 304, 305314, 315Forbidden150 kgE40
    Perfumery products with flammable solvents3UN1266II3IB2, T4, TP1, TP815020224215 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Permanganates, inorganic, aqueous solution, n.o.s.5.1UN3214II5.126, IB2, T4, TP11522022421 L5 LD56, 58, 69, 106, 107
    Permanganates, inorganic, n.o.s.5.1UN1482II5.126, A30, IB6, IP21522122425 kg25 kgD56, 58, 69, 106, 107
    III5.126, A30, IB8, IP315221324025 kg100 kgD56, 58, 69, 106, 107
    Peroxides, inorganic, n.o.s.5.1UN1483II5.1A7, A20, IB6, IP2, N34None2122425 kg25 kgA13, 75, 106
    III5.1A7, A20, IB8, IP3, N3415221324025 kg100 kgA13, 75, 106
    Peroxyacetic acid, with more than 43 percent and with more than 6 percent hydrogen peroxideForbidden
    Persulfates, inorganic, aqueous solution, n.o.s.5.1UN3216III5.1IB2, T4, TP1, TP291522032412.5 L30 LA
    Persulfates, inorganic, n.o.s.5.1UN3215III5.1IB8, IP315221324025 kg100 kgA
    GPesticides, liquid, flammable, toxic, flash point less than 23 degrees C3UN3021I3, 6.1B5, T14, TP2, TP13, TP27None201243Forbidden30 LB
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB
    GPesticides, liquid, toxic, flammable, n.o.s. flash point not less than 23 degrees C6.1UN2903I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3B1, IB3, T7, TP215320324260 L220 LA40
    GPesticides, liquid, toxic, n.o.s.6.1UN2902I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    GPesticides, solid, toxic, n.o.s.6.1UN2588I6.1IB7None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    PETN, see Pentaerythrite tetranitrate
    PETN/TNT, see Pentolite, etc
    Petrol, see Gasoline
    Petroleum crude oil3UN1267I3T11, TP1, TP8None2012431 L30 LE
    II3IB2, T4, TP1, TP81502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Petroleum distillates, n.o.s. or Petroleum products, n.o.s.3UN1268I3T11, TP1, TP81502012431 L30 LE
    II3IB2, T7, TP1, TP8, TP281502022425 L60 LB
    III3B1, IB3, T4, TP1, TP2915020324260 L220 LA
    Petroleum gases, liquefied or Liquefied petroleum gas2.1UN10752.1T50306304314, 315Forbidden150 kgE40
    DPetroleum oil3NA1270I3T11, TP1, TP9None2012431 L30 LE
    II3IB2, T7, TP1, TP8, TP281502022425 L60 LB
    III3B1, IB3, T4, TP1, TP2915020324260 L220 LA
    Phenacyl bromide6.1UN2645II6.1IB8, IP2, IP4None21224225 kg100 kgB40
    +Phenetidines6.1UN2311III6.1IB3, T4, TP115320324160 L220 LA
    Phenol, molten6.1UN2312II6.1B14, T7, TP3None202243ForbiddenForbiddenB40
    Start Printed Page 33393
    +Phenol, solid6.1UN1671II6.1IB8, IP2, IP4, N78, T6, TP2None21224225 kg100 kgA
    Phenol solutions6.1UN2821II6.1IB2, T7, TP2None2022435 L60 LA
    III6.1IB3, T4, TP115320324160 L220 LA
    Phenolsulfonic acid, liquid8UN1803II8B2, IB2, N41, T7, TP21542022421 L30 LC14
    Phenoxyacetic acid derivative pesticide, liquid, flammable, toxic flash point less than 23 degrees C.3UN3346I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Phenoxyacetic acid derivative pesticide, liquid, toxic6.1UN3348I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP271532022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Phenoxyacetic acid derivative pesticide, liquid, toxic, flammable, flash point not less than 23 degrees C6.1UN3347I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP271532022435 L60 LB40
    III6.1, 3IB3, T7, TP2, TP2815320324160 L220 LA40
    Phenoxyacetic acid derivative pesticide, solid, toxic6.1UN3345I6.1IB7, IP1None2112425 kg50 kgA40
    II6.1IB8, IP2, IP415321224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Phenyl chloroformate6.1UN2746II6.1, 8IB2, T7, TP2, TP13None2022431 L30 LA12, 13, 21, 25, 40, 100
    Phenyl isocyanate6.1UN2487I6.1, 32, B9, B14, B32, B74, B77, N33, N34, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    Phenyl mercaptan6.1UN2337I6.1, 32, B9, B14, B32, B74, B77, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenB26, 40
    Phenyl phosphorus dichloride8UN2798II8B2, B15, IB2, T7, TP2154202242Forbidden30 LB40
    Phenyl phosphorus thiodichloride8UN2799II8B2, B15, IB2, T7, TP2154202242Forbidden30 LB40
    Phenyl urea pesticides, liquid, toxic6.1UN3002I6.1T14, TP2, TP27None2012431 L30 LB40
    II6.1T7, TP2None2022435 L60 LB40
    III6.1T4, TP115320324160 L220 LA40
    Phenylacetonitrile, liquid6.1UN2470III6.1IB3, T4, TP115320324160 L220 LA26
    Phenylacetyl chloride8UN2577II8B2, IB2, T7, TP21542022421 L30 LC40
    Phenylcarbylamine chloride6.1UN1672I6.12, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD40
    m-Phenylene diaminediperchlorate (dry)Forbidden
    +Phenylenediamines (o-, m-, p-)6.1UN1673III6.1IB8, IP3, T7, TP1153213240100 kg200 kgA
    Phenylhydrazine6.1UN2572II6.1IB2, T7, TP2None2022435 L60 LA40
    Phenylmercuric acetate6.1UN1674II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Phenylmercuric compounds, n.o.s.6.1UN2026I6.1IB7, IP1None2112425 kg50 kgA
    II6.1IB8, IP2, IP4None21224225 kg100 kgA
    III6.1IB8, IP3153213240100 kg200 kgA
    Phenylmercuric hydroxide6.1UN1894II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Phenylmercuric nitrate6.1UN1895II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Phenyltrichlorosilane8UN1804II8A7, B6, IB2, N34, T7, TP2None202242Forbidden30 LC40
    Phosgene2.3UN10762.3, 81, B7, B46None192314ForbiddenForbiddenD40
    9-Phosphabicyclononanes or Cyclooctadiene phosphines4.2UN2940II4.2A19, IB6, IP2None21224115 kg50 kgA
    Phosphine2.3UN21992.3, 2.11None192245ForbiddenForbiddenD40
    Phosphoric acid8UN1805III8A7, IB3, IP3, N34, T4, TP11542032415 L60 LA
    Phosphoric acid triethyleneimine, see Tris-(1-aziridiyl)phosphine oxide, solution
    Phosphoric anhydride, see Phosphorus pentoxide
    Phosphorous acid8UN2834III8IB8, IP3, T3, TP115421324025 kg100 kgA48
    Phosphorus, amorphous4.1UN1338III4.1A1, A19, B1, B9, B26, IB8, IP3None21324325 kg100 kgA74
    Phosphorus bromide, see Phosphorus tribromide
    Phosphorus chloride, see Phosphorus trichloride
    Start Printed Page 33394
    Phosphorus heptasulfide, free from yellow or white phosphorus4.1UN1339II4.1A20, IB4, N34None21224015 kg50 kgB74
    Phosphorus oxybromide8UN1939II8B8, IB8, IP2, IP4, N41, N43, T7, TP2None212240Forbidden50 kgC12, 40
    Phosphorus oxybromide, molten8UN2576II8B2, B8, IB1, N41, N43, T7, TP3, TP13None202242ForbiddenForbiddenC40
    +Phosphorus oxychloride8UN1810II8, 6.12, A7, B9, B14, B32, B74, B77, N34, T20, TP2, TP38, TP45None227244ForbiddenForbiddenC40
    Phosphorus pentabromide8UN2691II8A7, IB8, IP2, IP4, N34154212240Forbidden50 kgB12, 40
    Phosphorus pentachloride8UN1806II8A7, IB8, IP2, IP4, N34None212240Forbidden50 kgC40
    Phosphorus pentafluoride, compressed2.3UN21982.3, 82, B9, B14None302, 304314, 315ForbiddenForbiddenD40
    Phosphorus pentasulfide, free from yellow or white phosphorus4.3UN1340II4.3, 4.1A20, B59, IB415121224215 kg50 kgB74
    Phosphorus pentoxide8UN1807II8A7, IB8, IP2, IP4, N3415421224015 kg50 kgA
    Phosphorus sesquisulfide, free from yellow or white phosphorus4.1UN1341II4.1A20, IB4, N34None21224015 kg50 kgB74
    Phosphorus tribromide8UN1808II8A3, A6, A7, B2, B25, IB2, N34, N43, T7, TP2None202242Forbidden30 LC40
    Phosphorus trichloride6.1UN1809I6.1, 82, B9, B14, B15, B32, B74, B77, N34, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenC40
    Phosphorus trioxide8UN2578III8IB8, IP315421324025 kg100 kgA12
    Phosphorus trisulfide, free from yellow or white phosphorus4.1UN1343II4.1A20, IB4, N34None21224015 kg50 kgB74
    Phosphorus, white dry or Phosphorus, white, under water or Phosphorus white, in solution or Phosphorus, yellow dry or Phosphorus, yellow, under water or Phosphorus, yellow, in solution4.2UN1381I4.2, 6.1B9, B26, N34, T9, TP3None188243ForbiddenForbiddenE
    Phosphorus white, molten4.2UN2447I4.2, 6.1B9, B26, N34, T21, TP3, TP7, TP26None188243ForbiddenForbiddenD
    Phosphorus (white or red) and a chlorate, mixtures ofForbidden
    Phosphoryl chloride, see Phosphorus oxychloride
    Phthalic anhydride with more than .05 percent maleic anhydride8UN2214III8IB8, IP3, T4, TP315421324025 kg100 kgA
    Picolines3UN2313III3B1, IB3, T4, TP115020324260 L220 LA40
    Picric acid, see Trinitrophenol, etc
    Picrite, see Nitroguanidine, etc
    Picryl chloride, see Trinitrochlorobenzene
    Pine oil3UN1272III3B1, IB3, T2, TP115020324260 L220 LA
    alpha-Pinene3UN2368III3B1, IB3, T2, TP115020324260 L220 LA
    Piperazine8UN2579III8IB8, IP3, T4, TP115421324025 kg100 kgA12
    Piperidine8UN2401I8, 3T10, TP2None2012430.5 L2.5 LB
    Pivaloyl chloride, see Trimethylacetyl chloride
    Plastic molding compound in dough, sheet or extruded rope form evolving flammable vapor9UN3314III932, IB8, IP6155221221100 kg200 kgA85, 87
    Plastic solvent, n.o.s., see Flammable liquids, n.o.s.
    Plastics, nitrocellulose-based, self-heating, n.o.s.4.2UN2006III4.2None213NoneForbiddenForbiddenC
    Poisonous gases, n.o.s., see Compressed or liquefied gases, flammable or toxic, n.o.s.
    Polyalkylamines, n.o.s., see Amines, etc
    Polychlorinated biphenyls, liquid9UN2315II99, 81, 140, IB3, T4, TP1155202241100 L220 LA95
    Polychlorinated biphenyls, solid9UN2315II99, 81, 140, IB7155212240100 kg200 kgA95
    Polyester resin kit3UN3269340152225None5 kg5 kgB
    Polyhalogenated biphenyls, liquid or Polyhalogenated terphenyls liquid9UN3151II9IB3155204241100 L220 LA95
    Polyhalogenated biphenyls, solid or Polyhalogenated terphenyls, solid9UN3152II9IB8, IP2, IP4155204241100 kg200 kgA95
    Start Printed Page 33395
    Polymeric beads, expandable, evolving flammable vapor9UN2211IIINone32, IB8, IP6155221221100 kg200 kgA85, 87
    Potassium4.3UN2257I4.3A19, A20, B27, IB1, IP1, N6, N34, T9, TP3, TP7None211244Forbidden15 kgD
    Potassium arsenate6.1UN1677II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Potassium arsenite6.1UN1678II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Potassium bisulfite solution, see Bisulfites, aqueous solutions, n.o.s.
    Potassium borohydride4.3UN1870I4.3A19, N40None211242Forbidden15 kgE
    Potassium bromate5.1UN1484II5.1IB8, IP41522122425 kg25 kgA56, 58, 106
    Potassium carbonylForbidden
    Potassium chlorate5.1UN1485II5.1A9, IB8, IP4, N341522122425 kg25 kgA56, 58, 106
    Potassium chlorate, aqueous solution5.1UN2427II5.1A2, IB2, T4, TP11522022411 L5 LB56, 58, 106
    III5.1A2, IB2, T4, TP11522032412.5 L30 LB56, 58, 69, 106
    Potassium chlorate mixed with mineral oil, see Explosive, blasting, type C
    Potassium cuprocyanide6.1UN1679II6.1IB8, IP2, IP4None21224225 kg100 kgA26
    Potassium cyanide6.1UN1680I6.1B69, B77, IB7, IP1, N74, N75, T14, TP2, TP13None2112425 kg50 kgB52
    Potassium dichloro isocyanurate or Potassium dichloro-s-triazinetrione, see Dichloroisocyanuric acid, dry or Dichloroisocyanuric acid salts etc
    Potassium dithionite or Potassium hydrosulfite4.2UN1929II4.2A8, A19, A20, IB6, IP2None21224115 kg50 kgE13
    Potassium fluoride6.1UN1812III6.1IB8, IP3, T4, TP1153213240100 kg200 kgA26
    Potassium fluoroacetate6.1UN2628I6.1IB7, IP1None2112425 kg50 kgE
    Potassium fluorosilicate6.1UN2655III6.1IB8, IP3153213240100 kg200 kgA26
    Potassium hydrate, see Potassium hydroxide, solid
    Potassium hydrogen fluoride, see Potassium hydrogen difluoride
    Potassium hydrogen fluoride solution, see Corrosive liquid, n.o.s.
    Potassium hydrogen sulfate8UN2509II8A7, IB8, IP2, IP4, N3415421224015 kg50 kgA
    Potassium hydrogendifluoride, solid8UN1811II8, 6.1IB8, IP2, IP4, N3, N34, T7, TP215421224015 kg50 kgA25, 26, 40
    Potassium hydrogendifluoride, solution8UN1811II8, 6.1IB8, IP2, IP4, N3, N34, T7, TP21542022431 L30 LA25, 26, 40
    Potassium hydrosulfite, see Potassium dithionite
    Potassium hydroxide, liquid, see Potassium hydroxide solution
    Potassium hydroxide, solid8UN1813II8IB8, IP2, IP415421224015 kg50 kgA
    Potassium hydroxide, solution8UN1814II8B2, IB2, T7, TP21542022421 L30 LA
    III8IB3, T4, TP11542032415 L60 LA
    Potassium hypochlorite, solution, see Hypochlorite solutions, etc
    Potassium, metal alloys4.3UN1420I4.3A19, A20, B27, IB4, IP1None211244Forbidden15 kgD
    Potassium metal, liquid alloy, see Alkali metal alloys, liquid, n.o.s.
    Potassium metavanadate6.1UN2864II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Potassium monoxide8UN2033II8IB8, IP2, IP415421224015 kg50 kgA
    Potassium nitrate5.1UN1486III5.1A1, A29, IB8, IP315221324025 kg100 kgA
    Potassium nitrate and sodium nitrite mixtures5.1UN1487II5.1B78, IB8, IP41522122405 kg25 kgA56, 58
    Potassium nitrite5.1UN1488II5.1IB8, IP41522122425 kg25 kgA56, 58
    Potassium perchlorate, solid5.1UN1489II5.1IB6, IP21522122425 kg25 kgA56, 58, 106
    Potassium perchlorate, solution5.1UN1489II5.1IB2, T4, TP11522022421 L5 LA56, 58, 106
    Potassium permanganate5.1UN1490II5.1IB8, IP41522122405 kg25 kgD56, 58, 69, 106, 107
    Potassium peroxide5.1UN1491I5.1A20, IB6, IP1, N34None211NoneForbidden15 kgB13, 75, 106
    Potassium persulfate5.1UN1492III5.1A1, A29, IB8, IP315221324025 kg100 kgA
    Potassium phosphide4.3UN2012I4.3, 6.1A19, N40None211NoneForbidden15 kgE40, 85
    Potassium selenate, see Selenates or Selenites
    Potassium selenite, see Selenates or Selenites
    Start Printed Page 33396
    Potassium sodium alloys4.3UN1422I4.3A19, B27, IB4, IP1, N34, N40, T9, TP3, TP7None211244Forbidden15 kgD
    Potassium sulfide, anhydrous or Potassium sulfide with less than 30 percent water of crystallization4.2UN1382II4.2A19, A20, B16, IB6, IP2, N34None21224115 kg50 kgA
    Potassium sulfide, hydrated with not less than 30 percent water of crystallization8UN1847II8IB8, IP2, IP415421224015 kg50 kgA26
    Potassium superoxide5.1UN2466I5.1A20, IB6, IP1None211NoneForbidden15 kgB13, 75, 106
    Powder cake, wetted or Powder paste, wetted with not less than 17 percent alcohol by mass1.1CUN0433II1.1CNone62NoneForbiddenForbidden10
    Powder cake, wetted or Powder paste, wetted with not less than 25 percent water, by mass1.3CUN0159II1.3CNone62NoneForbiddenForbidden10
    Powder paste, see Powder cake, etc
    Powder, smokeless1.1CUN0160II1.1CNone62NoneForbiddenForbidden26E
    Powder, smokeless1.3CUN0161II1.3CNone62NoneForbiddenForbidden26E
    Power device, explosive, see Cartridges, power device
    Primers, cap type1.4SUN0044IINoneNone62None25 kg100 kg05
    Primers, cap type1.1BUN0377II1.1BNone62NoneForbiddenForbidden11
    Primers, cap type1.4BUN0378II1.4BNone62NoneForbidden75 kg06
    Primers, small arms, see Primers, cap type
    Primers, tubular1.3GUN0319II1.3GNone62NoneForbiddenForbidden07
    Primers, tubular1.4GUN0320II1.4GNone62NoneForbidden75 kg06
    Primers, tubular1.4SUN0376IINoneNone62None25 kg100 kg05
    Printing ink, flammable or Printing ink related material (including printing ink thinning or reducing compound), flammable3UN1210I3T11, TP1, TP81501732431 L30 LE
    II3IB2, T4, TP1, TP81501732425 L60 LB
    III3B1, IB3, T2, TP115017324260 L220 LA
    Projectiles, illuminating, see Ammunition, illuminating, etc
    Projectiles, inert with tracer1.4SUN0345II1.4S62None25 kg100 kg01
    Projectiles, inert, with tracer1.3GUN0424II1.3G62NoneForbiddenForbidden03
    Projectiles, inert, with tracer1.4GUN0425II1.4G62NoneForbidden75 kg02
    Projectiles, with burster or expelling charge1.2DUN0346II1.2D62NoneForbiddenForbidden03
    Projectiles, with burster or expelling charge1.4DUN0347II1.4D62NoneForbidden75 kg02
    Projectiles, with burster or expelling charge1.2FUN0426II1.2F62NoneForbiddenForbidden08
    Projectiles, with burster or expelling charge1.4FUN0427II1.4F62NoneForbiddenForbidden08
    Projectiles, with burster or expelling charge1.2GUN0434II1.2G62NoneForbiddenForbidden03
    Projectiles, with burster or expelling charge1.4GUN0435II1.4G62NoneForbidden75 kg02
    Projectiles, with bursting charge1.1FUN0167II1.1F62NoneForbiddenForbidden08
    Projectiles, with bursting charge1.1DUN0168II1.1D62NoneForbiddenForbidden03
    Projectiles, with bursting charge1.2DUN0169II1.2D62NoneForbiddenForbidden03
    Projectiles, with bursting charge1.2FUN0324II1.2F62NoneForbiddenForbidden08
    Projectiles, with bursting charge1.4DUN0344II1.4D62NoneForbidden75 kg02
    Propadiene, stabilized2.1UN22002.1None304314, 315Forbidden150 kgB40
    Propadiene mixed with methyl acetylene, see Methyl acetylene and propadiene mixtures, stabilized
    Propane see also Petroleum gases, liquefied2.1UN19782.119, T50306304314, 315Forbidden150 kgE40
    Propanethiols3UN2402II3IB2, T4, TP1, TP131502022425 L60 LE95, 102
    n-Propanol or Propyl alcohol, normal3UN1274II3B1, IB2, T4, TP11502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Propellant, liquid1.3CUN0495II1.3C37None62NoneForbiddenForbidden10
    Propellant, liquid1.1CUN0497II1.1C37None62NoneForbiddenForbidden10
    Propellant, solid1.1CUN0498II1.1CNone62NoneForbiddenForbidden26E
    Propellant, solid1.3CUN0499II1.3CNone62NoneForbiddenForbidden26E
    Propellant, solid1.4CUN05011.4CNone62NoneForbiddenForbiddenA24E
    Propionaldehyde3UN1275II3IB2, T7, TP11502022425 L60 LE
    Propionic acid8UN1848III8IB3, T4, TP11542032415 L60 LA
    Propionic anhydride8UN2496III8IB3, T4, TP11542032415 L60 LA
    Propionitrile3UN2404II3, 6.1IB2, T7, TP1, TP13None202243Forbidden60 LE40
    Propionyl chloride3UN1815II3, 8IB1, T7, TP1None2022431 L5 LB40
    n-Propyl acetate3UN1276II3IB2, T4, TP11502022425 L60 LB
    Propyl alcohol, see Propanol
    n-Propyl benzene3UN2364III3B1, IB3, T2, TP115020324260 L220 LA
    Propyl chloride3UN1278II3IB2, IP8, N34, T7, TP2None202242Forbidden60 LE
    Start Printed Page 33397
    n-Propyl chloroformate6.1UN2740I6.1, 3, 82, A3, A6, A7, B9, B14, B32, B74, B77, N34, T20, TP2, TP13, TP38, TP44None227244ForbiddenForbiddenB21, 40, 100
    Propyl formates3UN1281II3IB2, T4, TP11502022425 L60 LB
    n-Propyl isocyanate6.1UN2482I6.1, 31, B9, B14, B30, B72, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenD40
    Propyl mercaptan, see Propanethiols
    n-Propyl nitrate3UN1865II3IB2, IP7150202None5 L60 LD
    Propylamine3UN1277II3, 8IB2, N34, T7, TP1None2022431 L5 LE40
    Propylene see also Petroleum gases, liquefied2.1UN10772.119, T50306304314, 315Forbidden150 kgE40
    Propylene chlorohydrin6.1UN2611II6.1, 3IB2, T7, TP2, TP13None2022435 L60 LA12, 40, 48
    Propylene oxide3UN1280I3A3, N34, T11, TP2, TP7None2012431 L30 LE40
    Propylene tetramer3UN2850III3B1, IB3, T2, TP115020324260 L220 LA
    1,2-Propylenediamine8UN2258II8, 3A3, A6, IB2, N34, T7, TP2None2022431 L30 LA40
    Propyleneimine, stabilized3UN1921I3, 6.1A3, N34, T14, TP2, TP13None2012431 L30 LB40
    Propyltrichlorosilane8UN1816II8, 3A7, B2, B6, IB2, N34, T7, TP2, TP13None202243Forbidden30 LC40
    Prussic acid, see Hydrogen cyanide
    Pyrethroid pesticide, liquid, flammable, toxic, flash point less than 23 degrees C3UN3350I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Pyrethroid pesticide, liquid toxic6.1UN3352I6.1T14, TP2, TP13, TP27None2112421 L30 LA40
    II6.1IB2, T11, TP2, TP271532122425 L60 LA40
    III6.1IB3, T7, TP2, TP2815321324060 L220 LA40
    Pyrethroid pesticide, liquid, toxic, flammable, flash point not less than 23 degrees C6.1UN3351I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3IB3, T7, TP2, TP2815320324160 L220 LB40
    Pyrethroid pesticide, solid, toxic6.1UN3349I6.1IB7, IP1None2112425 kg50 kgA40
    II6.1IB8, IP2, IP415321224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Pyridine3UN1282II3IB2, T4, TP2None2022425 L60 LB21, 100
    Pyridine perchlorateForbidden
    GPyrophoric liquid, inorganic, n.o.s.4.2UN3194I4.2None181244ForbiddenForbiddenD18
    GPyrophoric liquids, organic, n.o.s.4.2UN2845I4.2B11, T22, TP2, TP7None181244ForbiddenForbiddenD18
    GPyrophoric metals, n.o.s., or Pyrophoric alloys, n.o.s.4.2UN1383I4.2B11None187242ForbiddenForbiddenD
    GPyrophoric organometallic compound, water-reactive, n.o.s.4.2UN3203I4.2, 4.3T21, TP2, TP7None187242ForbiddenForbiddenD18
    GPyrophoric solid, inorganic, n.o.s.4.2UN3200I4.2None187242ForbiddenForbiddenD
    GPyrophoric solids, organic, n.o.s.4.2UN2846I4.2None187242ForbiddenForbiddenD
    Pyrosulfuryl chloride8UN1817II8B2, IB2, T8, TP2, TP121542022421 L30 LC40
    Pyroxylin solution or solvent, see Nitrocellulose
    Pyrrolidine3UN1922II3, 8IB2, T7, TP1None2022431 L5 LB40
    Quebrachitol pentanitrateForbidden
    Quicklime, see Calcium oxide
    Quinoline6.1UN2656III6.1IB3, T4, TP115320324160 L220 LA12
    R 12, see Dichlorodifluoromethane
    R 12B1, see Chlorodifluorobromomethane
    R 13, see Chlorotrifluoromethane
    R 13B1, see Bromotrifluoromethane
    R 14, see Tetrafluoromethane
    R 21, see Dichlorofluoromethane
    R 22, see Chlorodifluoromethane
    R 114, see Dichlorotetrafluoroethane
    R 115, see Chloropentafluoroethane
    R 116, see Hexafluoroethane
    R 124, see Chlorotetrafluoroethane
    R 133a, see Chlorotrifluoroethane
    Start Printed Page 33398
    R 152a, see Difluoroethane
    R 500, see Dichlorodifluoromethane and difluorethane, etc
    R 502, see Chlorodifluoromethane and chloropentafluoroethane mixture, etc
    R 503, see Chlorotrifluoromethane and trifluoromethane, etc
    DRadioactive material, excepted package-articles manufactured from natural or depleted uranium or natural thorium7UN2910None422, 426422, 426422, 426A
    IRadioactive material, excepted package-articles manufactured from natural uranium or depleted uranium or natural thorium7UN2909None422, 426422, 426422, 426A
    DRadioactive material, excepted package-empty package or empty packaging7UN2910Empty428428428A
    IRadioactive material, excepted package-empty packaging7UN2908Empty422, 428422, 428422, 428A
    DRadioactive material, excepted package-instruments or articles7UN2910None422, 424422, 424422, 424A
    IRadioactive material, excepted package-instruments or articles7UN2911None422, 424422, 424422, 424A
    Radioactive material, excepted package-limited quantity of material7UN2910None421, 422421, 422421, 422A
    DRadioactive material, fissile, n.o.s.7UN29187453417417A40, 95
    IRadioactive material, low specific activity (LSA-I) non fissile or fissile-excepted7UN29127T5, TP4, W7421, 422, 428427427A95
    IRadioactive material, low specific activity (LSA-II) non fissile or fissile-excepted7UN33217T5, TP4, W7421, 422, 428427427A95
    IRadioactive material, low specific activity (LSA-III) non fissile or fissile excepted7UN33227T5, TP4, W7421, 422, 428427427A95
    DRadioactive material, low specific activity, n.o.s. or Radioactive material, LSA, n.o.s.7UN29127T5, TP4421, 428427427A
    DRadioactive material, n.o.s.7UN29827421, 428415, 416415, 416A40, 95
    DRadioactive material, special form, n.o.s.7UN29747421, 424415, 416415, 416A
    DRadioactive material, surface contaminated object or Radioactive material, SCO7UN29137421, 424, 426427427A
    IRadioactive material, surface contaminated objects (SCO-I or SCO-II) non fissile or fissile-excepted7UN29137421, 422, 428427427A95
    IRadioactive material, transported under special arrangement, non fissile or fissile excepted7UN29197139
    IRadioactive material, transported under special arrangement, fissile7UN33317139
    IRadioactive material, Type A package, fissile non-special form7UN33277W7, W8453417417A95
    IRadioactive material, Type A package non-special form, non fissile or fissile-excepted7UN29157W7, W8415415A95
    IRadioactive material, Type A package, special form non fissile or fissile-excepted7UN33327W7, W8415, 476415, 476A95
    IRadioactive material, Type A package, special form, fissile7UN33337W7, W8453417, 476417, 476A
    IRadioactive material, Type B(M) package, fissile7UN33297453417417A
    IRadioactive material, Type B(M) package non fissile or fissile-excepted7UN29177416416A95
    IRadioactive material, Type B(U) package, fissile7UN33287453417417A
    IRadioactive material, Type B(U) package non fissile or fissile-excepted7UN29167416416A95
    IRadioactive material, uranium hexafluoride non fissile or fissile-excepted7UN29787, 8423420, 427420, 427A95
    IRadioactive material, uranium hexafluoride, fissile7UN29777, 8453417, 420417, 420A
    Start Printed Page 33399
    Railway torpedo, see Signals, railway track, explosive
    Rare gases and nitrogen mixtures, compressed2.2UN19812.2306302None75 kg150 kgA
    Rare gases and oxygen mixtures, compressed2.2UN19802.279306302None75 kg150 kgA
    Rare gases mixtures, compressed2.2UN19792.2306302None75 kg150 kgA
    RC 318, see Octafluorocyclobutane
    RDX and cyclotetramethylenetetranitramine, wetted or desensitized see RDX and HMX mixtures, wetted or desensitized
    RDX and HMX mixtures, wetted with not less than 15 percent water by mass or RDX and HMX mixtures, desensitized with not less than 10 percent phlegmatizer by mass1.1DUN0391II1.1DNone62NoneForbiddenForbidden10
    RDX and Octogen mixtures, wetted or desensitized see RDX and HMX mixtures, wetted or desensitized etc
    RDX, see Cyclotrimethylene trinitramine, etc
    Receptacles, small, containing gas (gas cartridges) flammable, without release device, not refillable and not exceeding 1 L capacity2.1UN20372.1306304None1 kg15 kgB40
    Receptacles, small, containing gas (gas cartridges) non-flammable, without release device, not refillable and not exceeding 1 L capacity2.2UN20372.2306304None1 kg15 kgB40
    Red phosphorus, see Phosphorus, amorphous
    Refrigerant gas R 404A2.2UN33372.2T50306304314, 31575 kg150 kgA
    Refrigerant gas R 407A2.2UN33382.2T50306304314, 31575 kg150 kgA
    Refrigerant gas R 407B2.2UN33392.2T50306304314, 31575 kg150 kgA
    Refrigerant gas R 407C2.2UN33402.2T50306304314, 31575 kg150 kgA
    GRefrigerant gases, n.o.s.2.2UN10782.2T50306304314, 31575 kg150 kgA
    DRefrigerant gases, n.o.s. or Dispersant gases, n.o.s.2.1NA19542.1T50306304314, 315Forbidden150 kgD40
    Refrigerating machines, containing flammable, non-toxic, liquefied gas2.1UN33582.1306306306ForbiddenForbiddenC40
    Refrigerating machines, containing non-flammable, non-toxic, liquefied gas or ammonia solution (UN2672)2.2UN28572.2A53306, 307306306, 307450 kg450 kgA
    Regulated medical waste6.2UN3291II6.2A13, A14134197NoneNo limitNo limitE
    Release devices, explosive1.4SUN0173II1.4SNone62None25 kg100 kg05
    Resin solution, flammable3UN1866I3B52, T11, TP1, TP81502012431 L30 LE
    II3B52, IB2, T4, TP1, TP81501732425 L60 LB
    III3B1, B52, IB3, T2, TP115017324260 L220 LA
    Resorcinol6.1UN2876III6.1IB8, IP3153213240100 kg200 kgA
    Rifle grenade, see Grenades, hand or rifle, etc
    Rifle powder, see Powder, smokeless (UN 0160)
    Rivets, explosive1.4SUN0174II1.4SNone62None25 kg100 kg05
    Road asphalt or tar liquid, see Tars, liquid, etc
    Rocket motors1.3CUN0186II1.3C109None62NoneForbidden220 kg03
    Rocket motors1.1CUN0280II1.1C109None62NoneForbiddenForbidden03
    Rocket motors1.2CUN0281II1.2C109None62NoneForbiddenForbidden03
    Rocket motors, liquid fueled1.2JUN0395II1.2J109None62NoneForbiddenForbidden0423E
    Rocket motors, liquid fueled1.3JUN0396II1.3J109None62NoneForbiddenForbidden0423E
    Rocket motors with hypergolic liquids with or without an expelling charge1.3LUN0250II1.3L109None62NoneForbiddenForbidden088E, 14E, 15E
    Rocket motors with hypergolic liquids with or without an expelling charge1.2LUN0322II1.2L109None62NoneForbiddenForbidden088E, 14E, 15E
    Rockets, line-throwing1.2GUN0238II1.2GNone62NoneForbiddenForbidden07
    Rockets, line-throwing1.3GUN0240II1.3GNone62NoneForbidden75 kg07
    Rockets, line-throwing1.4GUN0453II1.4GNone62NoneForbidden75 kg06
    Rockets, liquid fueled with bursting charge1.1JUN0397II1.1JNone62NoneForbiddenForbidden0423E
    Rockets, liquid fueled with bursting charge1.2JUN0398II1.2JNone62NoneForbiddenForbidden0423E
    Start Printed Page 33400
    Rockets, with bursting charge1.1FUN0180II1.1FNone62NoneForbiddenForbidden08
    Rockets, with bursting charge1.1EUN0181II1.1ENone62NoneForbiddenForbidden03
    Rockets, with bursting charge1.2EUN0182II1.2ENone62NoneForbiddenForbidden03
    Rockets, with bursting charge1.2FUN0295II1.2FNone62NoneForbiddenForbidden08
    Rockets, with expelling charge1.2CUN0436II1.2CNone62NoneForbiddenForbidden03
    Rockets, with expelling charge1.3CUN0437II1.3CNone62NoneForbiddenForbidden03
    Rockets, with expelling charge1.4CUN0438II1.4CNone62NoneForbidden75 kg02
    Rockets, with inert head1.3CUN0183II1.3CNone62NoneForbiddenForbidden03
    Rockets, with inert head1.2CUN05021.2None62NoneForbiddenForbiddenB1E, 5E
    Rosin oil3UN1286II3IB2, T4, TP11502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Rubber solution3UN1287II3IB2, T4, TP1, TP81502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Rubidium4.3UN1423I4.322, A7, A19, IB1, IP1, N34, N40, N45None211242Forbidden15 kgD
    Rubidium hydroxide8UN2678II8IB8, IP2, IP4, T7, TP215421224015 kg50 kgA
    Rubidium hydroxide solution8UN2677II8B2, IB2, T7, TP21542022421 L30 LA
    III8IB3, T4, TP11542032415 L60 LA
    Safety fuse, see Fuse, safety
    Sand acid, see Fluorosilicic acid
    Seed cake, containing vegetable oil solvent extractions and expelled seeds, with not more than 10 percent of oil and when the amount of moisture is higher than 11 percent, with not more than 20 percent of oil and moisture combined4.2UN1386IIINoneIB8, IP3, IP6, N7None213241ForbiddenForbiddenA13
    ISeed cake with more than 1.5 percent oil and not more than 11 percent moisture4.2UN1386IIINoneIB8, IP3, IP6, N7None213241ForbiddenForbiddenE13
    ISeed cake with not more than 1.5 percent oil and not more than 11 percent moisture4.2UN2217IIINoneIB8, IP3, IP6, N7None213241ForbiddenForbiddenA13
    Selenates or Selenites6.1UN2630I6.1IB7, IP1None2112425 kg50 kgE
    Selenic acid8UN1905I8IB7, IP1, N34None211242Forbidden25 kgA
    Selenium compound, n.o.s.6.1UN3283I6.1IB7, IP1, T14, TP2, TP27None2112425 kg50 kgB
    II6.1IB8, IP2, IP4, T11, TP2, TP27None21224225 kg100 kgB
    III6.1IB8, IP3, T7, TP1, TP28153213240100 kg200 kgA
    Selenium disulfide6.1UN2657II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Selenium hexafluoride2.3UN21942.3, 81None302NoneForbiddenForbiddenD40
    Selenium nitrideForbidden
    Selenium oxychloride8UN2879I8, 6.1A3, A6, A7, N34, T10, TP2, TP12, TP13None2012430.5 L2.5 LE40
    Self-defense spray, aerosol, see Aerosols, etc
    + A DSelf-defense spray, non-pressurized9NA3334III9A37155203NoneNo limitNo limitA
    GSelf-heating liquid, corrosive, inorganic, n.o.s.4.2UN3188II4.2, 8IB2None2022431 L5 LC
    III4.2, 8IB2None2032415 L60 LC
    GSelf-heating liquid, corrosive, organic, n.o.s.4.2UN3185II4.2, 8IB2None2022431 L5 LC
    III4.2, 8IB2None2032415 L60 LC
    GSelf-heating liquid, inorganic, n.o.s.4.2UN3186II4.2IB2None2022421 L5 LC
    III4.2IB2None2032415 L60 LC
    GSelf-heating liquid, organic, n.o.s.4.2UN3183II4.2IB2None2022421 L5 LC
    III4.2IB2None2032415 L60 LC
    GSelf-heating liquid, toxic, inorganic, n.o.s.4.2UN3187II4.2, 6.1IB2None2022431 L5 LC
    III4.2, 6.1IB2None2032415 L60 LC
    GSelf-heating liquid, toxic, organic, n.o.s.4.2UN3184II4.2, 6.1IB2None2022431 L5 LC
    III4.2, 6.1IB2None2032415 L60 LC
    GSelf-heating solid, corrosive, inorganic, n.o.s.4.2UN3192II4.2, 8IB5, IP2None21224215 kg50 kgC
    III4.2, 8IB8, IP3None21324225 kg100 kgC
    GSelf-heating, solid, corrosive, organic, n.o.s.4.2UN3126II4.2, 8IB5, IP2None21224215 kg50 kgC
    III4.2, 8IB8, IP3None21324225 kg100 kgC
    GSelf-heating solid, inorganic, n.o.s.4.2UN3190II4.2IB6, IP2None21224115 kg50 kgC
    III4.2IB8, IP3None21324125 kg100 kgC
    GSelf-heating, solid, organic, n.o.s.4.2UN3088II4.2IB6, IP2None21224115 kg50 kgC
    III4.2IB8, IP3None21324125 kg100 kgC
    GSelf-heating, solid, oxidizing, n.o.s.4.2UN31274.2, 5.1None214214ForbiddenForbidden
    GSelf-heating solid, toxic, inorganic, n.o.s.4.2UN3191II4.2, 6.1IB5, IP2None21224215 kg50 kgC
    III4.2, 6.1IB8, IP3None21324225 kg100 kgC
    Start Printed Page 33401
    GSelf-heating, solid, toxic, organic, n.o.s.4.2UN3128II4.2, 6.1IB5, IP2None21224215 kg50 kgC
    III4.2, 6.1IB8, IP3None21324225 kg100 kgC
    Self-propelled vehicle, see Engines or Batteries etc
    GSelf-reactive liquid type B4.1UN3221II4.153None224NoneForbiddenForbiddenD61
    GSelf-reactive liquid type B, temperature controlled4.1UN3231II4.153None224NoneForbiddenForbiddenD2, 61
    GSelf-reactive liquid type C4.1UN3223II4.1None224None5 L10 LD61
    GSelf-reactive liquid type C, temperature controlled4.1UN3233II4.1None224NoneForbiddenForbiddenD2, 61
    GSelf-reactive liquid type D4.1UN3225II4.1None224None5 L10 LD61
    GSelf-reactive liquid type D, temperature controlled4.1UN3235II4.1None224NoneForbiddenForbiddenD2, 61
    GSelf-reactive liquid type E4.1UN3227II4.1None224None10 L25 LD61
    GSelf-reactive liquid type E, temperature controlled4.1UN3237II4.1None224NoneForbiddenForbiddenD2, 61
    GSelf-reactive liquid type F4.1UN3229II4.1None224None10 L25 LD61
    GSelf-reactive liquid type F, temperature controlled4.1UN3239II4.1None224NoneForbiddenForbiddenD2, 61
    GSelf-reactive solid type B4.1UN3222II4.153None224NoneForbiddenForbiddenD61
    GSelf-reactive solid type B, temperature controlled4.1UN3232II4.153None224NoneForbiddenForbiddenD2, 61
    GSelf-reactive solid type C4.1UN3224II4.1None224None5 kg10 kgD61
    GSelf-reactive solid type C, temperature controlled4.1UN3234II4.1None224NoneForbiddenForbiddenD2, 61
    GSelf-reactive solid type D4.1UN3226II4.1None224None5 kg10 kgD61
    GSelf-reactive solid type D, temperature controlled4.1UN3236II4.1None224NoneForbiddenForbiddenD2, 61
    GSelf-reactive solid type E4.1UN3228II4.1None224None10 kg25 kgD61
    GSelf-reactive solid type E, temperature controlled4.1UN3238II4.1None224NoneForbiddenForbiddenD2, 61
    GSelf-reactive solid type F4.1UN3230II4.1None224None10 kg25 kgD61
    GSelf-reactive solid type F, temperature controlled4.1UN3240II4.1None224NoneForbiddenForbiddenD2, 61
    Shale oil3UN1288I3T11, TP1, TP8, TP27None2012431 L30 LB
    II3IB2, T4, TP1, TP81502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Shaped charges, see Charges, shaped, etc
    Signal devices, hand1.4GUN0191II1.4GNone62NoneForbidden75 kg06
    Signal devices, hand1.4SUN0373II1.4SNone62None25 kg100 kg05
    Signals, distress, ship1.1GUN0194II1.1GNone62NoneForbiddenForbidden07
    Signals, distress, ship1.3GUN0195II1.3GNone62NoneForbidden75 kg07
    Signals, highway, see Signal devices, hand
    Signals, railway track, explosive1.1GUN0192II1.1GNone62NoneForbiddenForbidden07
    Signals, railway track, explosive1.4SUN0193II1.4SNone62None25 kg100 kg05
    Signals, railway track, explosive1.3GUN04921.3GNone62NoneForbiddenForbidden07
    Signals, railway track, explosive1.4GUN04931.4GNone62NoneForbidden75 kg06
    Signals, ship distress, water-activated, see Contrivances, water-activated, etc
    Signals, smoke1.1GUN0196II1.1GNone62NoneForbiddenForbidden07
    Signals, smoke1.4GUN0197II1.4GNone62NoneForbidden75 kg06
    Signals, smoke1.2GUN0313II1.2GNone62NoneForbiddenForbidden07
    Signals, smoke1.3GUN0487II1.3GNone62NoneForbiddenForbidden07
    Silane, compressed2.1UN22032.1None302NoneForbiddenForbiddenE40, 57, 104
    Silicofluoric acid, see Fluorosilicic acid
    Silicon chloride, see Silicon tetrachloride
    Silicon powder, amorphous4.1UN1346III4.1A1, IB8, IP3None21324025 kg100 kgA
    Silicon tetrachloride8UN1818II8A3, A6, B2, B6, IB2, T7, TP2, TP71542022421 L30 LC40
    Silicon tetrafluoride, compressed2.3UN18592.3, 82None302NoneForbiddenForbiddenD40
    Silver acetylide (dry)Forbidden
    Silver arsenite6.1UN1683II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Silver azide (dry)Forbidden
    Silver chlorite (dry)Forbidden
    Silver cyanide6.1UN1684II6.1IB8, IP2, IP4None21224225 kg100 kgA26, 40
    Silver fulminate (dry)Forbidden
    Silver nitrate5.1UN1493II5.1IB8, IP41522122425 kg25 kgA
    Silver oxalate (dry)Forbidden
    Silver picrate (dry)Forbidden
    Silver picrate, wetted with not less than 30 percent water, by mass4.1UN1347I4.1None211NoneForbiddenForbiddenD28, 36
    Sludge, acid8UN1906II8A3, A7, B2, IB2, N34, T8, TP2, TP12None202242Forbidden30 LC14
    DSmokeless powder for small arms (100 pounds or less)4.1NA3178I4.116None171NoneForbidden7.3 kgA
    Soda lime with more than 4 percent sodium hydroxide8UN1907III8IB8, IP315421324025 kg100 kgA
    Start Printed Page 33402
    Sodium4.3UN1428I4.3A7, A8, A19, A20, B9, B48, B68, IB4, IP1, N34, T9, TP3, TP7, TP46None211244Forbidden15 kgD
    Sodium aluminate, solid8UN2812III8IB8, IP315421324025 kg100 kgA
    Sodium aluminate, solution8UN1819II8B2, IB2, T7, TP21542022421 L30 LA
    III8IB3, T4, TP11542032415 L60 LA
    Sodium aluminum hydride4.3UN2835II4.3A8, A19, A20, IB1151212242Forbidden50 kgE
    Sodium ammonium vanadate6.1UN2863II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Sodium arsanilate6.1UN2473III6.1IB8, IP3153213240100 kg200 kgA
    Sodium arsenate6.1UN1685II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Sodium arsenite, aqueous solutions6.1UN1686II6.1IB2, T7, TP2None2022435 L60 LA
    III6.1IB3, T4, TP215320324160 L220 LA
    Sodium arsenite, solid6.1UN2027II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Sodium azide6.1UN1687II6.1IB8, IP2, IP4None21224225 kg100 kgA36, 52, 91
    Sodium bifluoride, see Sodium hydrogendifluoride
    Sodium bisulfite, solution, see Bisulfites, aqueous solutions, n.o.s.
    Sodium borohydride4.3UN1426I4.3N40None211242Forbidden15 kgE
    Sodium borohydride and sodium hydroxide solution, with not more than 12 percent sodium borohydride and not more than 40 percent sodium hydroxide by mass8UN3320II8B2, IB2, N34, T7, TP21542022421 L30 LA26
    III8B2, IB3, N34, T4, TP21542032415 L60 LA
    Sodium bromate5.1UN1494II5.1IB8, IP41522122425 kg25 kgA56, 58, 106
    Sodium cacodylate6.1UN1688II6.1IB8, IP2, IP4None21224225 kg100 kgA26
    Sodium chlorate5.1UN1495II5.1A9, IB8, IP4, N34, T4, TP11522122405 kg25 kgA56, 58, 106
    Sodium chlorate, aqueous solution5.1UN2428II5.1A2, IB2, T4, TP11522022411 L5 LB56, 58, 106
    III5.1A2, IB2, T4, TP11522032412.5 L30 LB56, 58, 69, 106
    Sodium chlorate mixed with dinitrotoluene, see Explosive blasting, type C
    Sodium chlorite5.1UN1496II5.1A9, IB8, IP2, IP4, N34, T4, TP1None2122425 kg25 kgA56, 58, 106
    Sodium chloroacetate6.1UN2659III6.1IB8, IP3153213240100 kg200 kgA
    Sodium cuprocyanide, solid6.1UN2316I6.1IB7, IP1None2112425 kg50 kgA26
    Sodium cuprocyanide, solution6.1UN2317I6.1T14, TP2, TP13None2012431 L30 LB26, 40
    Sodium cyanide6.1UN1689I6.1B69, B77, IB7, IP1, N74, N75, T14, TP2, TP13None2112425 kg50 kgB52
    Sodium dichloroisocyanurate or Sodium dichloro-s-triazinetrione, see Dichloroisocyanuric acid etc
    Sodium dinitro-o-cresolate, dry or wetted with less than 15 percent water, by mass1.3CUN0234II1.3CNone62NoneForbiddenForbidden105E
    Sodium dinitro-o-cresolate, wetted with not less than 15 percent water, by mass4.1UN1348I4.1, 6.123, A8, A19, A20, N41None211None1 kg15 kgE28, 36
    Sodium dithionite or Sodium hydrosulfite4.2UN1384II4.2A19, A20, IB6, IP2None21224115 kg50 kgE13
    Sodium fluoride6.1UN1690III6.1IB8, IP3, T4, TP1153213240100 kg200 kgA26
    Sodium fluoroacetate6.1UN2629I6.1IB7, IP1None2112425 kg50 kgE
    Sodium fluorosilicate6.1UN2674III6.1IB8, IP3153213240100 kg200 kgA26
    Sodium hydrate, see Sodium hydroxide, solid
    Sodium hydride4.3UN1427I4.3A19, N40None211242Forbidden15 kgE
    Sodium hydrogendifluoride, solid8UN2439II8IB8, IP2, IP4, N3, N3415421224015 kg50 kgA12, 25, 26, 40
    Sodium hydrogendifluoride solution8UN2439II8IB8, IP2, IP4, N3, N341542022421 L30 LA12, 25, 26, 40
    Sodium hydrosulfide, with less than 25 percent water of crystallization4.2UN2318II4.2A7, A19, A20, IB6, IP2None21224115 kg50 kgA
    Sodium hydrosulfide with not less than 25 percent water of crystallization8UN2949II8A7, IB8, IP2, IP4, T7, TP215421224015 kg50 kgA26
    Sodium hydrosulfite, see Sodium dithionite
    Sodium hydroxide, solid8UN1823II8IB8, IP2, IP415421224015 kg50 kgA
    Sodium hydroxide solution8UN1824II8B2, IB2, N34, T7, TP21542022421 L30 LA
    III8IB3, N34, T4, TP11542032415 L60 LA
    Sodium hypochlorite, solution, see Hypochlorite solutions etc
    Start Printed Page 33403
    Sodium metal, liquid alloy, see Alkali metal alloys, liquid, n.o.s.
    Sodium methylate4.2UN1431II4.2, 8A19, IB5, IP2None21224215 kg50 kgB
    Sodium methylate solutions in alcohol3UN1289II3, 8IB2, T7, TP1, TP8None2022431 L5 LB
    III3, 8B1, IB3, T4, TP11502032425 L60 LA
    Sodium monoxide8UN1825II8IB8, IP2, IP415421224015 kg50 kgA
    Sodium nitrate5.1UN1498III5.1A1, A29, IB8, IP315221324025 kg100 kgA
    Sodium nitrate and potassium nitrate mixtures5.1UN1499III5.1A1, A29, IB8, IP315221324025 kg100 kgA
    Sodium nitrite5.1UN1500III5.1, 6.1A1, A29, IB8, IP315221324025 kg100 kgA56, 58
    Sodium pentachlorophenate6.1UN2567II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Sodium perchlorate5.1UN1502II5.1IB6, IP21522122425 kg25 kgA56, 58, 106
    Sodium permanganate5.1UN1503II5.1IB6, IP21522122425 kg25 kgD56, 58, 69, 106, 107
    Sodium peroxide5.1UN1504I5.1A20, IB6, IP1, N34None211NoneForbidden15 kgB13, 75, 106
    Sodium peroxoborate, anhydrous5.1UN3247II5.1IB8, IP41522122405 kg25 kgA13, 25, 106
    Sodium persulfate5.1UN1505III5.1A1, IB8, IP315221324025 kg100 kgA
    Sodium phosphide4.3UN1432I4.3, 6.1A19, N40None211NoneForbidden15 kgE40, 85
    Sodium picramate, dry or wetted with less than 20 percent water, by mass1.3CUN0235II1.3CNone62NoneForbiddenForbidden105E
    Sodium picramate, wetted with not less than 20 percent water, by mass4.1UN1349I4.123, A8, A19, N41None211NoneForbidden15 kgE28, 36
    Sodium picryl peroxideForbidden
    Sodium potassium alloys, see Potassium sodium alloys
    Sodium selenate, see Selenates or Selenites
    Sodium sulfide, anhydrous or Sodium sulfide with less than 30 percent water of crystallization4.2UN1385II4.2A19, A20, IB6, IP2, N34None21224115 kg50 kgA
    Sodium sulfide, hydrated with not less than30 percent water8UN1849II8IB8, IP2, IP4, T7, TP215421224015 kg50 kgA26
    Sodium superoxide5.1UN2547I5.1A20, IB6, IP1, N34None211NoneForbidden15 kgE13, 75, 106
    Sodium tetranitrideForbidden
    GSolids containing corrosive liquid, n.o.s.8UN3244II849, IB515421224015 kg50 kgB40
    GSolids containing flammable liquid, n.o.s.4.1UN3175II4.147, IB6, IP215121224015 kg50 kgB
    GSolids containing toxic liquid, n.o.s.6.1UN3243II6.148, IB2None21224025 kg100 kgB40
    Sounding devices, explosive1.2FUN0204II1.2FNone62NoneForbiddenForbidden08
    Sounding devices, explosive1.1FUN0296II1.1FNone62NoneForbiddenForbidden08
    Sounding devices, explosive1.1DUN0374II1.1DNone62NoneForbiddenForbidden07
    Sounding devices, explosive1.2DUN0375II1.2DNone62NoneForbiddenForbidden07
    Spirits of salt, see Hydrochloric acid
    Squibs, see Igniters etc
    Stannic chloride, anhydrous8UN1827II8B2, IB2, T7, TP21542022421 L30 LC
    Stannic chloride, pentahydrate8UN2440III8IB8, IP315421324025 kg100 kgA
    Stannic phosphide4.3UN1433I4.3, 6.1A19, N40None211242Forbidden15 kgE40, 85
    Steel swarf, see Ferrous metal borings, etc
    Stibine2.3UN26762.3, 2.11None304NoneForbiddenForbiddenD40
    Storage batteries, wet, see Batteries, wet etc
    Strontium arsenite6.1UN1691II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Strontium chlorate5.1UN1506II5.1A1, A9, IB8, IP2, IP4, N341522122425 kg25 kgA56, 58, 106
    Strontium nitrate5.1UN1507III5.1A1, A29, IB8, IP315221324025 kg100 kgA
    Strontium perchlorate5.1UN1508II5.1IB6, IP21522122425 kg25 kgA56, 58, 106
    Strontium peroxide5.1UN1509II5.1IB6, IP21522122425 kg25 kgA13, 75, 106
    Strontium phosphide4.3UN2013I4.3, 6.1A19, N40None211NoneForbidden15 kgE40, 85
    Strychnine or Strychnine salts6.1UN1692I6.1IB7, IP1None2112425 kg50 kgA40
    Styphnic acid, see Trinitroresorcinol, etc
    Styrene monomer, stabilized3UN2055III3B1, IB3, T2, TP115020324260 L220 LA
    GSubstances, explosive, n.o.s.1.1LUN0357II1.1L101None62NoneForbiddenForbidden8E, 14E, 15E, 17E
    GSubstances, explosive, n.o.s.1.2LUN0358II1.2L101None62NoneForbiddenForbidden8E, 14E, 15E, 17E
    Start Printed Page 33404
    GSubstances, explosive, n.o.s.1.3LUN0359II1.3L101None62NoneForbiddenForbidden8E, 14E, 15E, 17E
    GSubstances, explosive, n.o.s.1.1AUN0473II1.1A101, 111None62NoneForbiddenForbidden12
    GSubstances, explosive, n.o.s.1.1CUN0474II1.1C101None62NoneForbiddenForbidden10
    GSubstances, explosive, n.o.s.1.1DUN0475II1.1D101None62NoneForbiddenForbidden10
    GSubstances, explosive, n.o.s.1.1GUN0476II1.1G101None62NoneForbiddenForbidden08
    GSubstances, explosive, n.o.s.1.3CUN0477II1.3C101None62NoneForbiddenForbidden10
    GSubstances, explosive, n.o.s.1.3GUN0478II1.3G101None62NoneForbiddenForbidden08
    GSubstances, explosive, n.o.s.1.4CUN0479II1.4C101None62NoneForbidden75 kg09
    6Substances, explosive, n.o.s.1.4DUN0480II1.4D101None62NoneForbidden75 kg09
    GSubstances, explosive, n.o.s.1.4SUN0481II1.4S101None62None25 kg75 kg05
    GSubstances, explosive, n.o.s.1.4GUN0485II1.4G101None62NoneForbidden75 kg08
    GSubstances, explosive, very insensitive, n.o.s., or Substances, EVI, n.o.s.1.5DUN0482II1.5D101None62NoneForbiddenForbidden10
    Substituted nitrophenol pesticides, liquid, flammable, toxic , flash point less than 23 degrees C3UN2780I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Substituted nitrophenol pesticides, liquid, toxic6.1UN3014I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Substituted nitrophenol pesticides, liquid, toxic, flammable flash point not less than 23 degrees C6.1UN3013I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3B1, IB3, T7, TP2, TP2815320324260 L220 LA40
    Substituted nitrophenol pesticides, solid, toxic6.1UN2779I6.1IB7, IP1None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Sucrose octanitrate (dry)Forbidden
    Sulfamic acid8UN2967III8IB8, IP315421324025 kg100 kgA
    DSulfur9NA1350III930, IB8, IP2NoneNone240No limitNo limitA19, 74
    ISulfur4.1UN1350III4.130, IB8, IP3, T1, TP1NoneNone240No limitNo limitA19, 74
    Sulfur and chlorate, loose mixtures ofForbidden
    Sulfur chlorides8UN1828I85, A3, B10, B77, N34, T20, TP2, TP12None201243Forbidden2.5 LC40
    Sulfur dichloride, see Sulfur chlorides
    Sulfur dioxide2.3UN10792.3, 83, B14, T50, TP19None304314, 315Forbidden25 kgD40
    Sulfur dioxide solution, see Sulfurous acid
    Sulfur hexafluoride2.2UN10802.2306304314, 31575 kg150 kgA
    DSulfur, molten9NA2448III9IB3, T1, TP3None213247ForbiddenForbiddenC61
    ISulfur, molten4.1UN2448III4.1IB1, T1, TP3None213247ForbiddenForbiddenC61
    Sulfur tetrafluoride2.3UN24182.3, 81None302245ForbiddenForbiddenD40
    +Sulfur trioxide, stabilized8UN1829I8, 6.12, A7, B9, B14, B32, B49, B74, B77, N34, T20, TP4, TP12, TP13, TP25, TP26, TP38, TP45None227244ForbiddenForbiddenA40
    Sulfuretted hydrogen, see Hydrogen sulfide
    Sulfuric acid, fuming with less than 30 percent free sulfur trioxide8UN1831I8A3, A7, B84, N34, T20, TP2, TP12, TP13None201243Forbidden2.5 LC14, 40
    +Sulfuric acid, fuming with 30 percent or more free sulfur trioxide8UN1831I8, 6.12, A3, A6, A7, B9, B14, B32, B74, B77, B84, N34, T20, TP2, TP12, TP13None227244ForbiddenForbiddenC14, 40
    Sulfuric acid, spent8UN1832II8A3, A7, B2, B83, B84, IB2, N34, T8, TP2, TP12None202242Forbidden30 LC14
    Sulfuric acid with more than 51 percent acid8UN1830II8A3, A7, B3, B83, B84, IB2, N34, T8, TP2, TP121542022421 L30 LC14
    Sulfuric acid with not more than 51% acid8UN2796II8A3, A7, B2, B15, IB2, N6, N34, T8, TP2, TP121542022421 L30 LB
    Start Printed Page 33405
    Sulfuric and hydrofluoric acid mixtures, see Hydrofluoric and sulfuric acid mixtures
    Sulfuric anhydride, see Sulfur trioxide, stabilized
    Sulfurous acid8UN1833II8B3, IB2, T7, TP21542022421 L30 LB40
    +Sulfuryl chloride8UN1834I8, 6.11, A3, B6, B9, B10, B14, B30, B74, B77, N34, T22, TP2, TP12, TP38, TP44None226244ForbiddenForbiddenC40
    Sulfuryl fluoride2.3UN21912.34None304314, 315Forbidden25 kgD40
    Tars, liquid including road asphalt and oils, bitumen and cut backs3UN1999II3B13, IB2, T3, TP3, TP291502022425 L60 LB
    III3B1, B13, IB3, T1, TP315020324260 L220 LA
    Tear gas candles6.1UN1700II6.1, 4.1None340NoneForbidden50 kgD40
    Tear gas cartridges, see Ammunition, tear-producing, etc
    DTear gas devices with more than 2 percent tear gas substances, by mass6.1NA1693I6.1None340NoneForbiddenForbiddenD40
    II6.1None340NoneForbiddenForbiddenD40
    Tear gas devices, with not more than 2 percent tear gas substances, by mass, see Aerosols, etc
    Tear gas grenades, see Tear gas candles
    GTear gas substances, liquid, n.o.s.6.1UN1693I6.1None201NoneForbiddenForbiddenD40
    II6.1IB2None202NoneForbidden5 LD40
    GTear gas substances, solid, n.o.s.6.1UN1693I6.1None211NoneForbidden15 kgD40
    II6.1IB8, IP2, IP4None212NoneForbidden25 kgD40
    Tellurium compound, n.o.s.6.1UN3284I6.1IB7, IP1, T14, TP2, TP27None2112425 kg50 kgB
    II6.1IB8, IP2, IP4, T11, TP2, TP27None21224225 kg100 kgB
    III6.1IB8, IP3, T7, TP1, TP28153213240100 kg200 kgA
    Tellurium hexafluoride2.3UN21952.3, 81None302NoneForbiddenForbiddenD40
    Terpene hydrocarbons, n.o.s.3UN2319III3B1, IB3, T4, TP1, TP2915020324260 L220 LA
    Terpinolene3UN2541III3B1, IB3, T2, TP115020324260 L220 LA
    Tetraazido benzene quinoneForbidden
    Tetrabromoethane6.1UN2504III6.1IB3, T4, TP115320324160 L220 LA
    Tetrachloroethane6.1UN1702II6.1IB2, N36, T7, TP2None2022435 L60 LA40
    Tetrachloroethylene6.1UN1897III6.1IB3, N36, T4, TP115320324160 L220 LA40
    Tetraethyl dithiopyrophosphate6.1UN1704II6.1IB8, IP2, IP4None21224225 kg100 kgD40
    Tetraethyl silicate3UN1292III3B1, IB3, T2, TP115020324260 L220 LA
    Tetraethylammonium perchlorate (dry)Forbidden
    Tetraethylenepentamine8UN2320III8IB3, T4, TP11542032415 L60 LA
    1,1,1,2-Tetrafluoroethane or Refrigerant gas R 134a2.2UN31592.2T50306304314, 31575 kg150 kgA
    Tetrafluoroethylene, stabilized2.1UN10812.1306304NoneForbidden150 kgE40
    Tetrafluoromethane, compressed or Refrigerant gas R 142.2UN19822.2None302None75 kg150 kgA
    1,2,3,6-Tetrahydrobenzaldehyde3UN2498III3B1, IB3, T2, TP115020324260 L220 LA
    Tetrahydrofuran3UN2056II3IB2, T4, TP1None2022425 L60 LB
    Tetrahydrofurfurylamine3UN2943III3B1, IB3, T2, TP115020324260 L220 LA
    Tetrahydrophthalic anhydrides with more than 0.05 percent of maleic anhydride8UN2698III8IB8, IP315421324025 kg100 kgA
    1,2,3,6-Tetrahydropyridine3UN2410II3IB2, T4, TP11502022425 L60 LB
    Tetrahydrothiophene3UN2412II3IB2, T4, TP11502022425 L60 LB
    Tetramethylammonium hydroxide8UN1835II8B2, IB2, T7, TP21542022421 L30 LA
    Tetramethylene diperoxide dicarbamideForbidden
    Tetramethylsilane3UN2749I3T14, TP2None201243Forbidden30 LD
    Tetranitro diglycerinForbidden
    Tetranitroaniline1.1DUN0207II1.1DNone62NoneForbiddenForbidden10
    +Tetranitromethane5.1UN1510I5.1, 6.12, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP44None227NoneForbiddenForbiddenD40, 66, 106
    2,3,4,6-TetranitrophenolForbidden
    2,3,4,6-Tetranitrophenyl methyl nitramineForbidden
    2,3,4,6-TetranitrophenylnitramineForbidden
    Tetranitroresorcinol (dry)Forbidden
    2,3,5,6-Tetranitroso-1,4-dinitrobenzeneForbidden
    2,3,5,6-Tetranitroso nitrobenzene (dry)Forbidden
    Tetrapropylorthotitanate3UN2413III3B1, IB3, T4, TP115020324260 L220 LA
    Tetrazene, see Guanyl nitrosaminoguanyltetrazene
    Start Printed Page 33406
    Tetrazine (dry)Forbidden
    Tetrazol-1-acetic acid1.4CUN0407II1.4CNone62NoneForbidden75 kg09
    1H-Tetrazole1.1DUN05041.1DNone62NoneForbiddenForbiddenB1E, 5E
    Tetrazolyl azide (dry)Forbidden
    Tetryl, see Trinitrophenylmethylnitramine
    Thallium chlorate5.1UN2573II5.1, 6.1IB6, IP2None2122425 kg25 kgA56, 58, 106
    Thallium compounds, n.o.s.6.1UN1707II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Thallium nitrate6.1UN2727II6.1, 5.1IB6, IP2None2122425 kg25 kgA
    4-Thiapentanal6.1UN2785III6.1IB3, T4, TP115320324160 L220 LD25, 49
    Thioacetic acid3UN2436II3IB2, T4, TP11502022425 L60 LB
    Thiocarbamate pesticide, liquid, flammable, toxic, flash point less than 23 degrees C3UN2772I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP13, TP27None2022431 L60 LB40
    Thiocarbamate pesticide, liquid, toxic, flammable, flash point not less than 23 degrees C6.1UN3005I6.1, 3T14, TP2, TP13None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3IB3, T7, TP2, TP2815320324260 L220 LA40
    Thiocarbamate pesticide, liquid, toxic6.1UN3006I6.1T14, TP2, TP13None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Thiocarbamate pesticides, solid, toxic6.1UN2771I6.1IB7, IP1None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Thiocarbonylchloride, see Thiophosgene
    Thioglycol6.1UN2966II6.1IB2, T7, TP2None2022435 L60 LA
    Thioglycolic acid8UN1940II8A7, B2, IB2, N34, T7, TP21542022421 L30 LA
    Thiolactic acid6.1UN2936II6.1IB2, T7, TP2None2022435 L60 LA
    Thionyl chloride8UN1836I8A7, B6, B10, N34, T10, TP2, TP12, TP13None201243ForbiddenForbiddenC40
    Thiophene3UN2414II3IB2, T4, TP11502022425 L60 LB40
    +Thiophosgene6.1UN2474II6.12, A7, B9, B14, B32, B74, N33, N34, T20, TP2, TP38, TP45None227244ForbiddenForbiddenB26, 40
    Thiophosphoryl chloride8UN1837II8A3, A7, B2, B8, B25, IB2, N34, T7, TP2None202242Forbidden30 LC40
    Thiourea dioxide4.2UN3341II4.2IB6, IP2None21224115 kg50 kgD
    III4.2IB8, IP3None21324125 kg100 kgD
    DThorium metal, pyrophoric7UN29757, 4.2None418NoneForbiddenForbiddenD
    DThorium nitrate, solid7UN29767, 5.1None419NoneForbidden15 kgA
    Tin chloride, fuming, see Stannic chloride, anhydrous
    Tin perchloride or Tin tetrachloride, see Stannic chloride, anhydrous
    Tinctures, medicinal3UN1293II3IB2, T4, TP1, TP81502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Tinning flux, see Zinc chloride
    Titanium disulphide4.2UN3174III4.2IB8, IP3None21324125 kg100 kgA
    Titanium hydride4.1UN1871II4.1A19, A20, IB4, N34None21224115 kg50 kgE
    Titanium powder, dry4.2UN2546I4.2None211242ForbiddenForbiddenD
    II4.2A19, A20, IB6, IP2, N5, N34None21224115 kg50 kgD
    III4.2IB8, IP3None21324125 kg100 kgD
    Titanium powder, wetted with not less than 25 percent water (a visible excess of water must be present) (a) mechanically produced, particle size less than 53 microns; (b) chemically produced, particle size less than 840 microns4.1UN1352II4.1A19, A20, IB6, IP2, N34None21224015 kg50 kgE
    Titanium sponge granules or Titanium sponge powders4.1UN2878III4.1A1, IB8, IP3None21324025 kg100 kgD
    +Titanium tetrachloride8UN1838II8, 6.12, A3, A6, B7, B9, B14, B32, B74, B77, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenC40
    Titanium trichloride mixtures8UN2869II8A7, IB8, IP2, IP4, N3415421224015 kg50 kgA40
    III8A7, IB8, IP3, N3415421324025 kg100 kgA40
    Start Printed Page 33407
    Titanium trichloride, pyrophoric or Titanium trichloride mixtures, pyrophoric4.2UN2441I4.2, 8A7, A8, A19, A20, N34None181244ForbiddenForbiddenD40
    TNT mixed with aluminum, see Tritonal
    TNT, see Trinitrotoluene, etc
    Toluene3UN1294II3IB2, T4, TP11502022425 L60 LB
    +Toluene diisocyanate6.1UN2078II6.1IB2, T7, TP2, TP13None2022435 L60 LD25, 40
    Toluene sulfonic acid, see Alkyl, or Aryl sulfonic acid etc
    +Toluidines liquid6.1UN1708II6.1IB2, T7, TP2None2022435 L60 LA
    +Toluidines solid6.1UN1708II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA
    2,4-Toluylenediamine or 2,4-Toluenediamine6.1UN1709III6.1IB8, IP3, T4, TP1153213240100 kg200 kgA
    Torpedoes, liquid fueled, with inert head1.3JUN0450II1.3J62NoneForbiddenForbidden0423E
    Torpedoes, liquid fueled, with or without bursting charge1.1JUN0449II1.1J62NoneForbiddenForbidden0423E
    Torpedoes with bursting charge1.1EUN0329II1.1E62NoneForbiddenForbidden03
    Torpedoes with bursting charge1.1FUN0330II1.1F62NoneForbiddenForbidden08
    Torpedoes with bursting charge1.1DUN0451II1.1D62NoneForbiddenForbidden03
    GToxic liquid, corrosive, inorganic, n.o.s.6.1UN3289I6.1, 8T14, TP2, TP13, TP27None2012430.5 L2.5 LA
    II6.1, 8IB2, T11, TP2, TP27None2022431 L30 LA
    GToxic liquid, corrosive, inorganic, n.o.s. Inhalation Hazard, Packing Group I, Zone A6.1UN3289I6.1, 81, B9, B14, B30, B72, T22, TP2, TP13, TP27, TP38, TP44None226244ForbiddenForbiddenB40
    GToxic liquid, corrosive, inorganic, n.o.s. Inhalation Hazard, Packing Group I, Zone B6.1UN3289I6.1, 82, B9, B14, B32, B74, T20, TP2, TP13, TP27, TP38, TP45None227244ForbiddenForbiddenB40
    GToxic liquid, inorganic, n.o.s.6.1UN3287I6.1T14, TP2, TP13, TP27None2012431 L30 LA
    II6.1IB2, T11, TP2, TP27None2022435 L60 LA
    III6.1IB3, T7, TP1, TP2815320324160 L220 LA
    GToxic liquid, inorganic, n.o.s. Inhalation Hazard, Packing Group I, Zone A6.1UN3287I6.11, B9, B14, B30, B72, T22, TP2, TP13, TP27, TP38, TP44None226244ForbiddenForbiddenB40
    GToxic liquid, inorganic, n.o.s. Inhalation Hazard, Packing Group I, Zone B6.1UN3287I6.12, B9, B14, B32, B74, T20, TP2, TP13, TP27, TP38, TP45None227244ForbiddenForbiddenB40
    GToxic liquids, corrosive, organic, n.o.s.6.1UN2927I6.1, 8T14, TP2, TP13, TP27None2012430.5 L2.5 LB40
    II6.1, 8IB2, T11, TP2, TP27None2022431 L30 LB40
    GToxic liquids, corrosive, organic, n.o.s., inhalation hazard, Packing Group I, Zone A6.1UN2927I6.1, 81, B9, B14, B30, B72, T22, TP2, TP13, TP27, TP38, TP44None226244ForbiddenForbiddenD40
    GToxic liquids, corrosive, organic, n.o.s., inhalation hazard, Packing Group I, Zone B6.1UN2927I6.1, 82, B9, B14, B32, B74, T20, TP2, TP13, TP27, TP38, TP45None227244ForbiddenForbiddenD40
    GToxic liquids, flammable, organic, n.o.s.6.1UN2929I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    GToxic liquids, flammable, organic, n.o.s., inhalation hazard, Packing Group I, Zone A6.1UN2929I6.1, 31, B9, B14, B30, B72, T22, TP2, TP13, TP27, TP38, TP44None226244ForbiddenForbiddenD40
    GToxic liquids, flammable, organic, n.o.s., inhalation hazard, Packing Group I, Zone B6.1UN2929I6.1, 32, B9, B14, B32, B74, T20, TP2, TP13, TP27, TP38, TP45None227244ForbiddenForbiddenD40
    GToxic, liquids, organic, n.o.s.6.1UN2810I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP1, TP2815320324160 L220 LA40
    GToxic, liquids, organic, n.o.s. Inhalation hazard, Packing Group I, Zone A6.1UN2810I6.11, B9, B14, B30, B72, T22, TP2, TP13, TP27, TP38, TP44None226244ForbiddenForbiddenD40
    GToxic, liquids, organic, n.o.s. Inhalation hazard, Packing Group I, Zone B6.1UN2810I6.12, B9, B14, B32, B74, T20, TP2, TP13, TP27, TP38, TP45None227244ForbiddenForbiddenD40
    Start Printed Page 33408
    GToxic liquids, oxidizing, n.o.s.6.1UN3122I6.1, 5.1A4None201243Forbidden2.5 LC
    II6.1, 5.1IB2None2022431 L5 LC
    GToxic liquids, oxidizing, n.o.s. Inhalation hazard, Packing Group I, Zone A6.1UN3122I6.1, 5.11, B9, B14, B30, B72, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenC
    GToxic liquids, oxidizing, n.o.s. Inhalation Hazard, Packing Group I, Zone B6.1UN3122I6.1, 5.12, B9, B14, B32, T20, TP2, TP13, TP38, TP44None227244ForbiddenForbiddenC
    GToxic liquids, water-reactive, n.o.s.6.1UN3123I6.1, 4.3A4None201243Forbidden1 LE40
    II6.1, 4.3IB2None2022431 L5 LE40
    GToxic liquids, water-reactive, n.o.s. Inhalation hazard, packing group I, Zone A6.1UN3123I6.1, 4.31, B9, B14, B30, B72, T22, TP2, TP13, TP38, TP44None226244ForbiddenForbiddenE40
    GToxic liquids, water-reactive, n.o.s. Inhalation hazard, packing group I, Zone B6.1UN3123I6.1, 4.32, B9, B14, B32, B74, T20, TP2, TP13, TP38, TP44None227244ForbiddenForbiddenE40
    GToxic solid, corrosive, inorganic, n.o.s.6.1UN3290I6.1, 8IB7None2112421 kg25 kgA
    II6.1, 8IB6, IP2None21224215 kg50 kgA
    GToxic solid, inorganic, n.o.s.6.1UN3288I6.1IB7None2112425 kg50 kgA
    II6.1IB8, IP2, IP4None21224225 kg100 kgA
    III6.1IB8, IP3153213240100 kg200 kgA
    GToxic solids, corrosive, organic, n.o.s.6.1UN2928I6.1, 8IB7None2112421 kg25 kgB40
    II6.1, 8IB6, IP2None21224215 kg50 kgB40
    GToxic solids, flammable, organic, n.o.s.6.1UN2930I6.1, 4.1IB6None2112421 kg15 kgB
    II6.1, 4.1IB8, IP2, IP4None21224215 kg50 kgB
    GToxic solids, organic, n.o.s.6.1UN2811I6.1IB7None2112425 kg50 kgB
    II6.1IB8, IP2, IP4None21224225 kg100 kgB
    III6.1IB8, IP3153213240100 kg200 kgA
    GToxic solids, oxidizing, n.o.s.6.1UN3086I6.1, 5.1None2112421 kg15 kgC
    II6.1, 5.1IB6, IP2None21224215 kg50 kgC
    GToxic solids, self-heating, n.o.s.6.1UN3124I6.1, 4.2A5None2112425 kg15 kgD40
    II6.1, 4.2IB6, IP2None21224215 kg50 kgD40
    GToxic solids, water-reactive, n.o.s.6.1UN3125I6.1, 4.3A5None2112425 kg15 kgD40
    II6.1, 4.3IB6, IP2None21224215 kg50 kgD40
    DToy Caps1.4SNA0337II1.4SNone62None25 kg100 kg05
    Tracers for ammunition1.3GUN0212II1.3GNone62NoneForbiddenForbidden07
    Tracers for ammunition1.4GUN0306II1.4GNone62NoneForbidden75 kg06
    Tractors, see Vehicle, etc
    Tri-(b-nitroxyethyl) ammonium nitrateForbidden
    Triallyl borate6.1UN2609III6.1IB315320324160 L220 LA13
    Triallylamine3UN2610III3, 8B1, IB3, T4, TP1None2032425 L60 LA40
    Triazine pesticides, liquid, flammable, toxic, flash point less than 23 degrees C3UN2764I3, 6.1T14, TP2, TP13, TP27None201243Forbidden30 LB40
    II3, 6.1IB2, T11, TP2, TP13, TP27None2022431 L60 LB40
    Triazine pesticides, liquid, toxic6.1UN2998I6.1T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1IB3, T7, TP2, TP2815320324160 L220 LA40
    Triazine pesticides, liquid, toxic, flammable, flash point not less than 23 degrees C6.1UN2997I6.1, 3T14, TP2, TP13, TP27None2012431 L30 LB40
    II6.1, 3IB2, T11, TP2, TP13, TP27None2022435 L60 LB40
    III6.1, 3IB3, T7, TP2, TP2815320324260 L220 LA40
    Triazine pesticides, solid, toxic6.1UN2763I6.1IB7, IP1None2112425 kg50 kgA40
    II6.1IB8, IP2, IP4None21224225 kg100 kgA40
    III6.1IB8, IP3153213240100 kg200 kgA40
    Tributylamine6.1UN2542II6.1IB2, T7, TP2None2022435 L60 LA
    Tributylphosphane4.2UN3254I4.2None211242ForbiddenForbiddenD
    Trichloro-s-triazinetrione dry, with more than 39 percent available chlorine, see Trichloroisocyanuric acid, dry
    Trichloroacetic acid8UN1839II8A7, IB8, IP2, IP4, N3415421224015 kg50 kgA
    Trichloroacetic acid, solution8UN2564II8A3, A6, A7, B2, IB2, N34, T7, TP21542022421 L30 LB
    III8A3, A6, A7, IB3, N34, T4, TP11542032415 L60 LB8
    +Trichloroacetyl chloride8UN2442II8, 6.12, A3, A7, B9, B14, B32, B74, N34, T20, TP2, TP38, TP45None227244ForbiddenForbiddenD40
    Trichlorobenzenes, liquid6.1UN2321III6.1IB3, T4, TP115320324160 L220 LA
    Trichlorobutene6.1UN2322II6.1IB2, T7, TP2None2022435 L60 LA25, 40
    1,1,1-Trichloroethane6.1UN2831III6.1IB3, N36, T4, TP115320324160 L220 LA40
    Trichloroethylene6.1UN1710III6.1IB3, N36, T4, TP115320324160 L220 LA40
    Start Printed Page 33409
    Trichloroisocyanuric acid, dry5.1UN2468II5.1IB8, IP41522122405 kg25 kgA13
    Trichloromethyl perchlorateForbidden
    Trichlorosilane4.3UN1295I4.3, 3, 8A7, N34, T14, TP2, TP7, TP13None201244ForbiddenForbiddenD21, 28, 40, 49, 100
    Tricresyl phosphate with more than 3 percent ortho isomer6.1UN2574II6.1A3, IB2, N33, N34, T7, TP2None2022435 L60 LA
    Triethyl phosphite3UN2323III3B1, IB3, T2, TP115020324260 L220 LA
    Triethylamine3UN1296II3, 8IB2, T7, TP1None2022431 L5 LB40
    Triethylenetetramine8UN2259II8B2, IB2, T7, TP21542022421 L30 LB40
    Trifluoroacetic acid8UN2699I8A3, A6, A7, B4, N3, N34, T10, TP2, TP12None2012430.5 L2.5 LB12, 40
    Trifluoroacetyl chloride2.3UN30572.3, 82, B7, B9, B14, T50, TP21None304314, 315ForbiddenForbiddenD40
    Trifluorochloroethylene, stabilized2.3UN10822.3, 2.13, B14, T50None304314, 315ForbiddenForbiddenD40
    1,1,1-Trifluoroethane, compressed or Refrigerant gas R 143a2.1UN20352.1T50306304314, 315Forbidden150 kgB40
    Trifluoromethane or Refrigerant gas R 232.2UN19842.2306304314, 31575 kg150 kgA
    Trifluoromethane, refrigerated liquid2.2UN31362.2T75, TP5306None314, 31550 kg500 kgD
    2-Trifluoromethylaniline6.1UN2942III6.1IB315320324160 L220 LA
    3-Trifluoromethylaniline6.1UN2948II6.1IB2, T7, TP2None2022435 L60 LA40
    Triformoxime trinitrateForbidden
    Triisobutylene3UN2324III3B1, IB3, T4, TP115020324260 L220 LA
    Triisopropyl borate3UN2616II3IB2, T4, TP11502022425 L60 LA
    III3B1, IB3, T2, TP115020324260 L220 LA
    DTrimethoxysilane6.1NA9269I6.1, 32, B9, B14, B32, B74, T20, TP4, TP12, TP13, TP38, TP45None227244ForbiddenForbiddenE40
    Trimethyl borate3UN2416II3IB2, T7, TP11502022425 L60 LB
    Trimethyl phosphite3UN2329III3B1, IB3, T2, TP115020324260 L220 LA
    1,3,5-Trimethyl-2,4,6-trinitrobenzeneForbidden
    Trimethylacetyl chloride6.1UN2438I6.1, 8, 32, A3, A6, A7, B3, B9, B14, B32, B74, N34, T20, TP2, TP13, TP38, TP45None227244ForbiddenForbiddenD25, 40
    Trimethylamine, anhydrous2.1UN10832.1T50306304314, 315Forbidden150 kgB40
    Trimethylamine, aqueous solutions with not more than 50 percent trimethylamine by mass3UN1297I3, 8T11, TP1None2012430.5 L2.5 LD40, 41
    II3, 8B1, IB2, T7, TP1None2022431 L5 LB40, 41
    III3, 8B1, IB3, T7, TP11502032425 L60 LA40, 41
    1,3,5-Trimethylbenzene3UN2325III3B1, IB3, T2, TP1None20324260 L220 LA
    Trimethylchlorosilane3UN1298II3, 8A3, A7, B77, IB2, N34, T7, TP2, TP13None2022431 L5 LE40
    Trimethylcyclohexylamine8UN2326III8IB3, T4, TP11542032415 L60 LA
    Trimethylene glycol diperchlorateForbidden
    Trimethylhexamethylene diisocyanate6.1UN2328III6.1IB3, T4, TP2, TP1315320324160 L220 LB
    Trimethylhexamethylenediamines8UN2327III8IB3, T4, TP11542032415 L60 LA
    Trimethylol nitromethane trinitrateForbidden
    Trinitro-meta-cresol1.1DUN0216II1.1DNone62NoneForbiddenForbidden105E
    2,4,6-Trinitro-1,3-diazobenzeneForbidden
    2,4,6-Trinitro-1,3,5-triazido benzene (dry)Forbidden
    Trinitroacetic acidForbidden
    TrinitroacetonitrileForbidden
    Trinitroamine cobaltForbidden
    Trinitroaniline or Picramide1.1DUN0153II1.1DNone62NoneForbiddenForbidden10
    Trinitroanisole1.1DUN0213II1.1DNone62NoneForbiddenForbidden10
    Trinitrobenzene, dry or wetted with less than 30 percent water, by mass1.1DUN0214II1.1DNone62NoneForbiddenForbidden10
    Trinitrobenzene, wetted with not less than 30 percent water, by mass4.1UN1354I4.123, A2, A8, A19, N41None211None0.5 kg0.5 kgE28
    Trinitrobenzenesulfonic acid1.1DUN0386II1.1DNone62NoneForbiddenForbidden105E
    Trinitrobenzoic acid, dry or wetted with less than 30 percent water, by mass1.1DUN0215II1.1DNone62NoneForbiddenForbidden10
    Trinitrobenzoic acid, wetted with not less than 30 percent water, by mass4.1UN1355I4.123, A2, A8, A19, N41None211None0.5 kg0.5 kgE28
    Trinitrochlorobenzene or Picryl chloride1.1DUN0155II1.1DNone62NoneForbiddenForbidden10
    TrinitroethanolForbidden
    TrinitroethylnitrateForbidden
    Trinitrofluorenone1.1DUN0387II1.1DNone62NoneForbiddenForbidden10
    TrinitromethaneForbidden
    1,3,5-TrinitronaphthaleneForbidden
    Start Printed Page 33410
    Trinitronaphthalene1.1DUN0217II1.1DNone62NoneForbiddenForbidden10
    Trinitrophenetole1.1DUN0218II1.1DNone62NoneForbiddenForbidden10
    Trinitrophenol or Picric acid, dry or wetted with less than 30 percent water, by mass1.1DUN0154II1.1DNone62NoneForbiddenForbidden105E
    Trinitrophenol, wetted with not less than 30 percent water, by mass4.1UN1344I4.123, A8, A19, N41None211None1 kg15 kgE28, 36
    2,4,6-Trinitrophenyl guanidine (dry)Forbidden
    2,4,6-Trinitrophenyl nitramineForbidden
    2,4,6-Trinitrophenyl trimethylol methyl nitramine trinitrate (dry)Forbidden
    Trinitrophenylmethylnitramine or Tetryl1.1DUN0208II1.1DNone62NoneForbiddenForbidden10
    Trinitroresorcinol or Styphnic acid, dry or wetted with less than 20 percent water, or mixture of alcohol and water, by mass1.1DUN0219II1.1DNone62NoneForbiddenForbidden105E
    Trinitroresorcinol, wetted or Styphnic acid, wetted with not less than 20 percent water, or mixture of alcohol and water by mass1.1DUN0394II1.1DNone62NoneForbiddenForbidden105E
    2,4,6-Trinitroso-3-methyl nitraminoanisoleForbidden
    Trinitrotetramine cobalt nitrateForbidden
    Trinitrotoluene and Trinitrobenzene mixtures or TNT and trinitrobenzene mixtures or TNT and hexanitrostilbene mixtures or Trinitrotoluene and hexanitrostilnene mixtures1.1DUN0388II1.1DNone62NoneForbiddenForbidden10
    Trinitrotoluene mixtures containing Trinitrobenzene and Hexanitrostilbene or TNT mixtures containing trinitrobenzene and hexanitrostilbene1.1DUN0389II1.1DNone62NoneForbiddenForbidden10
    Trinitrotoluene or TNT, dry or wetted with less than 30 percent water, by mass1.1DUN0209II1.1DNone62NoneForbiddenForbidden10
    Trinitrotoluene, wetted with not less than 30 percent water, by mass4.1UN1356I4.123, A2, A8, A19, N41None211None0.5 kg0.5 kgE28
    Tripropylamine3UN2260III3, 8B1, IB3, T4, TP11502032425 L60 LA40
    Tripropylene3UN2057II3IB2, T4, TP11502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Tris-(1-aziridinyl)phosphine oxide, solution6.1UN2501II6.1IB2, T7, TP2None2022435 L60 LA
    III6.1IB3, T4, TP115320324160 L220 LA
    Tris, bis-bifluoroamino diethoxy propane (TVOPA)Forbidden
    Tritonal1.1DUN0390II1.1DNone62NoneForbiddenForbidden10
    Tungsten hexafluoride2.3UN21962.3, 82None338NoneForbiddenForbiddenD40
    Turpentine3UN1299III3B1, IB3, T2, TP115020324260 L220 LA
    Turpentine substitute3UN1300I3T11, TP1, TP8, TP27None2012431 L30 LB
    II3IB2, T4, TP11502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Undecane3UN2330III3B1, IB3, T2, TP115020324260 L220 LA
    DUranium hexafluoride, fissile excepted or non-fissile7UN29787, 8423420, 427420, 427
    DUranium hexafluoride, fissile (with more than 1 percent U-235)7UN29777, 8453417, 420417, 420A
    DUranium metal, pyrophoric7UN29797, 4.2None418NoneD
    DUranyl nitrate hexahydrate solution7UN29807, 8421, 427415, 416, 417415, 416, 417D
    DUranyl nitrate, solid7UN29817, 5.1None419NoneForbidden15 kgA
    Urea hydrogen peroxide5.1UN1511III5.1, 8A1, A7, A29, IB8, IP315221324025 kg100 kgA13
    Urea nitrate, dry or wetted with less than 20 percent water, by mass1.1DUN0220II1.1D119None62NoneForbiddenForbidden10
    Urea nitrate, wetted with not less than 20 percent water, by mass4.1UN1357I4.139, A8, A19, N41None211None1 kg15 kgA28
    Urea peroxide, see Urea hydrogen peroxide
    Valeraldehyde3UN2058II3IB2, T4, TP11502022425 L60 LB
    Valeric acid, see Corrosive liquids, n.o.s.
    Valeryl chloride8UN2502II8, 3A3, A6, A7, B2, IB2, N34, T7, TP21542022431 L30 LC40
    Vanadium compound, n.o.s.6.1UN3285I6.1IB7, IP1, T14, TP2, TP27None2112425 kg50 kgB
    Start Printed Page 33411
    II6.1IB8, IP2, IP4, T11, TP2, TP27None21224225 kg100 kgB
    III6.1IB8, IP3, T7, TP1, TP28153213240100 kg200 kgA
    Vanadium oxytrichloride8UN2443II8A3, A6, A7, B2, B16, IB2, N34, T7, TP2154202242Forbidden30 LC40
    Vanadium pentoxide, non-fused form6.1UN2862III6.1IB8, IP3153213240100 kg200 kgA40
    Vanadium tetrachloride8UN2444I8A3, A6, A7, B4, N34, T10, TP2None201243Forbidden2.5 LC40
    Vanadium trichloride8UN2475III8IB8, IP315421324025 kg100 kgA40
    Vanadyl sulfate6.1UN2931II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Vehicle, flammable gas powered9UN31669135220220220ForbiddenNo limitA
    Vehicle, flammable liquid powered9UN31669135220220220No limitNo limitA
    Very signal cartridge, see Cartridges, signal
    Vinyl acetate, stabilized3UN1301II3IB2, T4, TP11502022425 L60 LB
    Vinyl bromide, stabilized2.1UN10852.1T50306304314, 315Forbidden150 kgB40
    Vinyl butyrate, stabilized3UN2838II3IB2, T4, TP11502022425 L60 LB
    Vinyl chloride, stabilized or Vinyl chloride, stabilized2.1UN10862.121, B44, T50306304314, 315Forbidden150 kgB40
    Vinyl chloroacetate6.1UN2589II6.1, 3IB2, T7, TP2None2022435 L60 LA
    Vinyl ethyl ether, stabilized3UN1302I3A3, T11, TP2None2012431 L30 LD
    Vinyl fluoride, stabilized2.1UN18602.1306304314, 315Forbidden150 kgE40
    Vinyl isobutyl ether, stabilized3UN1304II3IB2, T4, TP11502022425 L60 LB
    Vinyl methyl ether, stabilized2.1UN10872.1B44, T50306304314, 315Forbidden150 kgB40
    Vinyl nitrate polymerForbidden
    Vinylidene chloride, stabilized3UN1303I3T12, TP2, TP71502012431 L30 LE40
    Vinylpyridines, stabilized6.1UN3073II6.1, 3, 8IB1, T7, TP2, TP13None2022431 L30 LB40
    Vinyltoluenes, stabilized3UN2618III3B1, IB3, T2, TP115020324260 L220 LA
    Vinyltrichlorosilane, stabilized3UN1305I3, 8A3, A7, B6, N34, T11, TP2, TP13None201243Forbidden2.5 LB40
    Warheads, rocket with burster or expelling charge1.4DUN0370II1.4DNone62NoneForbidden75 kg02
    Warheads, rocket with burster or expelling charge1.4FUN0371II1.4FNone62NoneForbiddenForbidden08
    Warheads, rocket with bursting charge1.1DUN0286II1.1DNone62NoneForbiddenForbidden03
    Warheads, rocket with bursting charge1.2DUN0287II1.2DNone62NoneForbiddenForbidden03
    Warheads, rocket with bursting charge1.1FUN0369II1.1FNone62NoneForbiddenForbidden08
    Warheads, torpedo with bursting charge1.1DUN0221II1.1DNone62NoneForbiddenForbidden03
    GWater-reactive liquid, corrosive, n.o.s.4.3UN3129I4.3, 8None201243Forbidden1 LD
    II4.3, 8IB1None2022431 L5 LE85
    III4.3, 8IB2None2032425 L60 LE
    GWater-reactive liquid, n.o.s.4.3UN3148I4.3None201244Forbidden1 LE40
    II4.3IB1None2022431 L5 LE40
    III4.3IB2None2032425 L60 LE40
    GWater-reactive liquid, toxic, n.o.s.4.3UN3130I4.3, 6.1A4None201243Forbidden1 LD
    II4.3, 6.1IB1None2022431 L5 LE85
    III4.3, 6.1IB2None2032425 L60 LE85
    GWater-reactive solid, corrosive, n.o.s.4.3UN3131I4.3, 8IB4, IP1, N40None211242Forbidden15 kgD
    II4.3, 8IB6, IP215121224215 kg50 kgE85
    III4.3, 8IB8, IP415121324125 kg100 kgE85
    GWater-reactive solid, flammable, n.o.s.4.3UN3132I4.3, 4.1IB4, N40None211242Forbidden15 kgD
    II4.3, 4.1IB415121224215 kg50 kgE
    III4.3, 4.1IB615121324125 kg100 kgE
    GWater-reactive solid, n.o.s.4.3UN2813I4.3IB4, N40None211242Forbidden15 kgE40
    II4.3IB7, IP215121224215 kg50 kgE40
    III4.3IB8, IP415121324125 kg100 kgE40
    GWater-reactive, solid, oxidizing, n.o.s.4.3UN3133II4.3, 5.1None214214ForbiddenForbiddenE40
    III4.3, 5.1None214214ForbiddenForbiddenE40
    GWater-reactive solid, self-heating, n.o.s.4.3UN3135I4.3, 4.2N40None211242Forbidden15 kgE
    II4.3, 4.2IB5, IP2None21224215 kg50 kgE
    III4.3, 4.2IB8, IP4None21324125 kg100 kgE
    GWater-reactive solid, toxic, n.o.s.4.3UN3134I4.3, 6.1A8, IB4, IP1, N40None211242Forbidden15 kgD
    II4.3, 6.1IB5, IP215121224215 kg50 kgE85
    III4.3, 6.1IB8, IP415121324125 kg100 kgE85
    Wheel chair, electric, see Battery powered vehicle or Battery powered equipment
    White acid, see Hydrofluoric acid
    IWhite asbestos (chrysotile, actinolite, anthophyllite, tremolite)9UN2590III9IB8, IP2, IP3155216240200 kg200 kgA34, 40
    Wood preservatives, liquid3UN1306II3IB2, T4, TP1, TP81502022425 L60 LB40
    III3B1, IB3, T2, TP115020324260 L220 LA40
    Xanthates4.2UN3342II4.2IB6, IP2None21224115 kg50 kgD40
    Start Printed Page 33412
    III4.2IB8, IP3None21324125 kg100 kgD40
    Xenon, compressed2.2UN20362.2306302None75 kg150 kgA
    Xenon, refrigerated liquid (cryogenic liquids)2.2UN25912.2T75, TP5320NoneNone50 kg500 kgB
    Xylenes3UN1307II3IB2, T4, TP11502022425 L60 LB
    III3B1, IB3, T2, TP115020324260 L220 LA
    Xylenols6.1UN2261II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA
    Xylidines, solid6.1UN1711II6.1IB8, IP2, IP4, T7, TP2None21224225 kg100 kgA
    Xylidines, solution6.1UN1711II6.1IB2, T7, TP2None2022435 L60 LA
    Xylyl bromide6.1UN1701II6.1A3, A6, A7, IB2, N33, T7, TP2, TP13None340NoneForbidden60 LD40
    p-Xylyl diazideForbidden
    Zinc ammonium nitrite5.1UN1512II5.1IB8, IP4None2122425 kg25 kgE
    Zinc arsenate or Zinc arsenite or Zinc arsenate and zinc arsenite mixtures6.1UN1712II6.1IB8, IP2, IP4None21224225 kg100 kgA
    Zinc ashes4.3UN1435III4.3A1, A19, IB8, IP415121324125 kg100 kgA
    Zinc bisulfite solution, see Bisulfites, aqueous solutions, n.o.s.
    Zinc bromate5.1UN2469III5.1A1, A29, IB8, IP315221324025 kg100 kgA56, 58, 106
    Zinc chlorate5.1UN1513II5.1A9, IB8, IP2, IP4, N341522122425 kg25 kgA56, 58, 106
    Zinc chloride, anhydrous8UN2331III8IB8, IP3None21324025 kg100 kgA
    Zinc chloride, solution8UN1840III8IB3, T4, TP11542032415 L60 LA
    Zinc cyanide6.1UN1713I6.1IB7, IP1None2112425 kg50 kgA26
    Zinc dithionite or Zinc hydrosulfite9UN1931IIINoneIB8155204240100 kg200 kgA49
    Zinc ethyl, see Diethylzinc
    Zinc fluorosilicate6.1UN2855III6.1IB8, IP3153213240100 kg200 kgA26
    Zinc hydrosulfite, see Zinc dithionite
    Zinc muriate solution, see Zinc chloride, solution
    Zinc nitrate5.1UN1514II5.1IB8, IP41522122405 kg25 kgA
    Zinc permanganate5.1UN1515II5.1IB6, IP21522122425 kg25 kgD56, 58, 69, 106, 107
    Zinc peroxide5.1UN1516II5.1IB6, IP21522122425 kg25 kgA13, 75, 106
    Zinc phosphide4.3UN1714I4.3, 6.1A19, N40None211NoneForbidden15 kgE40, 85
    Zinc powder or Zinc dust4.3UN1436I4.3, 4.2A19, IB4, IP1, N40None211242Forbidden15 kgA
    II4.3, 4.2A19, IB7, IP2None21224215 kg50 kgA
    III4.3, 4.2IB8, IP4None21324225 kg100 kgA
    Zinc resinate4.1UN2714III4.1A1, IB615121324025 kg100 kgA
    Zinc selenate, see Selenates or Selenites
    Zinc selenite, see Selenates or Selenites
    Zinc silicofluoride, see Zinc fluorosilicate
    Zirconium, dry, coiled wire, finished metal sheets, strip (thinner than 254 microns but not thinner than 18 microns)4.1UN2858III4.1A1, IB815121324025 kg100 kgA
    Zirconium, dry, finished sheets, strip or coiled wire4.2UN2009III4.2A1, A19, IB8None21324025 kg100 kgD
    Zirconium hydride4.1UN1437II4.1A19, A20, IB4, N34None21224015 kg50 kgE
    Zirconium nitrate5.1UN2728III5.1A1, A29, IB8, IP315221324025 kg100 kgA
    Zirconium picramate, dry or wetted with less than 20 percent water, by mass1.3CUN0236II1.3CNone62NoneForbiddenForbidden105E
    Zirconium picramate, wetted with not less than 20 percent water, by mass4.1UN1517I4.123, N41None211None1 kg15 kgD28, 36
    Zirconium powder, dry4.2UN2008I4.2None211242ForbiddenForbiddenD
    II4.2A19, A20, IB6, IP2, N5, N34None21224115 kg50 kgD
    III4.2IB8, IP3None21324125 kg100 kgD
    Zirconium powder, wetted with not less than 25 percent water (a visible excess of water must be present) (a) mechanically produced, particle size less than 53 microns; (b) chemically produced, particle size less than 840 microns4.1UN1358II4.1A19, A20, IB6, IP2, N34None21224115 kg50 kgE
    Zirconium scrap4.2UN1932III4.2IB8, IP3, N34None213240ForbiddenForbiddenD
    Zirconium suspended in a liquid3UN1308I3None201243ForbiddenForbiddenB
    II3IB2None2022425 L60 LB
    III3B1, IB215020324260 L220 LB
    Start Printed Page 33413
    Zirconium tetrachloride8UN2503III8IB8, IP315421324025 kg100 kgA
    Start Amendment Part

    12. In Appendix B to § 172.101, paragraphs 1. and 2. are revised and the List of Marine Pollutants is amended by removing 94 entries, adding 16 entries and revising 1 entry in appropriate alphabetical order to read as follows:

    End Amendment Part

    Appendix B to § 172.101—List of Marine Pollutants

    1. See § 171.4 of this subchapter for applicability to marine pollutants. This appendix lists potential marine pollutants as defined in § 171.8 of this subchapter.

    2. Marine pollutants listed in this appendix are not necessarily listed by name in the § 172.101 Table. If a marine pollutant not listed by name or by synonym in the § 172.101 Table meets the definition of any hazard Class 1 through 8, then you must determine the class and division of the material in accordance with § 173.2a of this subchapter. You must also select the most appropriate hazardous material description and proper shipping name. If a marine pollutant not listed by name or by synonym in the § 172.101 Table does not meet the definition of any Class 1 through 8, then you must offer it for transportation under the most appropriate of the following two Class 9 entries: “Environmentally hazardous substances, liquid, n.o.s.,” UN3082, or “Environmentally hazardous substances, solid, n.o.s.” UN3077.

    * * * * *

     List of Marine Pollutants

    S.M.P.Marine Pollutant
    (1)(2)
    [Remove:]Acetal Acetaldehyde
    Amyl mercaptans
    Anisole
    Benzaldehyde
    Butyl benzenes
    n-Butyl butyrate
    Butyl mercaptans
    Butylphenols, liquid
    Butylphenols, solid
    Butyraldehyde
    Calcium naphthenate
    Camphor oil
    Chlorotoluenes (ortho-, meta-, para-)
    Coal tar
    Coal tar naphtha
    Creosote (coal tar)
    Creosote (wood tar)
    Cresols (o-; m-; p-)
    Cresylic acid
    Cresylic acid sodium salt
    normal-Decaldehyde
    normal-Decanol
    Decyl acrylate
    1,2-Dichlorobenzene
    Dichlorobenzene (meta; ortho; para)
    Dichlorophenols, liquid
    Dichlorophenols, solid
    2,4-Dichlorophenoxyacetic acid (see also 2,4D)
    2,4 Dichlorophenoxyacetic acid diethanolamine salt
    2,4 Dichlorophenoxyacetic acid dimethylamine salt
    2,4-Dichlorophenoxyacetic acid triisopropylamine salt
    Diethybenzenes (mixed isomers)
    Diisopropylnaphthalene
    Dimethyl disulphide
    Dimethyl glyoxal (butanedione)
    Dimethyl sulphide
    Diphenyl ether
    Diphenyl ether/biphenyl phenyl ether mixtures
    Diphenyl/diphenyl ether (mixtures)
    EPTC (ISO)
    Ethyl acrylate, inhibited
    Ethyl chlorothioformate
    1-Ethyl-2-methylbenzene
    2-Ethylbutyraldehyde
    2-Ethylhexenal
    2,4-Hexadiene aldehyde
    normal-Hexaldehyde
    Iron oxide, spent
    Iron sponge, spent
    Isobutyl aldehyde
    Isobutyl isobutyrate
    Isobutyl priopionate
    Isobutyraldehyde
    Isodecaldehyde
    Isodecanol
    Isononanol
    Isooctanol
    Isopropylbenzene
    Isovaleraldehyde
    1-Methyl-4-ethylbenzene
    2-Methyl-5-ethylpyridine
    Methyl salicylate
    2-Methylbutyraldehyde
    Methylnaphthalenes, liquid
    Methylnaphthalenes, solid
    Methylstyrenes, inhibited
    Naphthalene, crude or refined
    Naphthalene, molten
    Naphthenic acids, liquid
    Naphthenic acids, solid
    Nitrocresols
    Nitrotolueunes (ortho-;meta-;para-), liquid
    Nitrotoluenes (ortho-;meta-;para-), solid
    1-Nonanal
    1-Nonanol
    1-Octanol
    Phenylethylene, inhibited
    alpha-Pinene
    Propanethiols
    Propionaldehyde
    n-Propylbenzene
    Styrene monomer, inhibited
    n-Tetramethylbenzenes
    4-Thiapentanal
    1,2,3-Trimethylbenzene
    1,2,4-Trimethyl benzene
    1,3,5-Trimethyl benzene
    Turpentine
    1-Undecanol
    normal-Valeraldehyde
    Vinylbenzene, inhibited
    Vinyltoluenes, inhibited mixed isomers
    Xylenols
    [Add:]
    *    *    *    *    *
    Acrolein, stabilized
    *    *    *    *    *
    Chlorotoluenes (meta-;para-)
    *    *    *    *    *
    Cyanogen chloride, stabilized
    *    *    *    *    *
    Desmedipham
    *    *    *    *    *
    PPDiclofop-methyl
    *    *    *    *    *
    Dichlorobenzene (meta-; para-)
    *    *    *    *    *
    Diisopropylnaphthalenes, mixed isomers
    *    *    *    *    *
    Ethyl acrylate, stabilized
    *    *    *    *    *
    PPFenchlorazole-ethyl
    *    *    *    *    *
    PPFenoxapro-ethyl
    Start Printed Page 33414
    PPFenoxaprop-P-ethyl
    *    *    *    *    *
    Linuron
    *    *    *    *    *
    PPSilafluofen
    *    *    *    *    *
    PP1,2,3—Trichlorobenzene
    *    *    *    *    *
    Vinylidene chloride, stabilized
    Vinyltoluenes, stabilized
    *    *    *    *    *
    [Revise:]
    PPDodecyl hydroxypropyl sulfide
    *    *    *    *    *
    Start Amendment Part

    13. In § 172.102:

    End Amendment Part Start Amendment Part

    a. In paragraph (c)(1), Special Provisions 43, 110 and 136 are revised and Special Provisions 139, 142 and 143 are added;

    End Amendment Part Start Amendment Part

    b. In paragraph (c)(2), Special Provision A53 is added;

    End Amendment Part Start Amendment Part

    c. Paragraph (c)(3) introductory text and Special Provisions B53 and B69 are revised;

    End Amendment Part Start Amendment Part

    d. In paragraph (c)(3), Special Provisions B100, B101, B103, B104, B105, B106, B108, B109 and B110 are removed;

    End Amendment Part Start Amendment Part

    e. Paragraphs (c)(4) and (c)(7) are revised; and

    End Amendment Part Start Amendment Part

    f. Paragraph (c)(8), Special Provisions W7, W8 and W9 are added in numerical order.

    End Amendment Part

    The additions and revisions read as follows:

    Special provisions.
    * * * * *

    (c) * * *

    (1) * * *

    Code/Special Provisions

    * * * * *

    43 The membrane filters, including paper separators and coating or backing materials, that are present in transport, must not be able to propagate a detonation as tested by one of the tests described in the UN Manual of Tests and Criteria, Part I, Test series 1(a) (see § 171.7 of this subchapter). On the basis of the results of suitable burning rate tests, and taking into account the standard tests in the UN Manual of Tests and Criteria, Part III, subsection 33.2.1 (see § 171.7 of this subchapter), nitrocellulose membrane filters in the form in which they are to be transported that do not meet the criteria for a Division 4.1 material are not subject to the requirements of this subchapter. Packagings must be so constructed that explosion is not possible by reason of increased internal pressure. Nitrocellulose membrane filters covered by this entry, each with a mass not exceeding 0.5 g, are not subject to the requirements of this subchapter when contained individually in an article or a sealed packet.

    * * * * *

    110 Fire extinguishers transported under UN1044 may include installed actuating cartridges (cartridges, power device of Division 1.4C or 1.4S), without changing the classification of Division 2.2, provided the aggregate quantity of deflagrating (propellant) explosives does not exceed 3.2 grams per extinguishing unit.

    * * * * *

    136 This entry only applies to machinery and apparatus containing hazardous materials as in integral element of the machinery or apparatus. It may not be used to describe machinery or apparatus for which a proper shipping name exists in the § 172.101 Table. Except when approved by the Associate Administrator, machinery or apparatus may only contain hazardous materials for which exceptions are referenced in Column (8) of the § 172.101 Table and are provided in part 173, subpart D, of this subchapter. Hazardous materials shipped under this entry are excepted from the labeling requirements of this subchapter unless offered for transportation or transported by aircraft and are not subject to the placarding requirements of part 173, subpart F, of this subchapter. Orientation markings as described in § 172.312 (a)(2) are required when liquid hazardous materials may escape due to incorrect orientation. The machinery or apparatus, if unpackaged, or the packaging in which it is contained shall be marked “Dangerous goods in machinery” or “Dangerous goods in apparatus”, as appropriate, with the identification number UN3363. For transportation by aircraft, machinery or apparatus may not contain any material forbidden for transportation by passenger or cargo aircraft. The Associate Administrator may except from the requirements of this subchapter, equipment, machinery and apparatus provided:

    a. It is shown that it does not pose a significant risk in transportation;

    b. The quantities of hazardous materials do not exceed those specified in § 173.4 of this subchapter; and

    c. The equipment, machinery or apparatus conforms with § 173.222 of this subchapter.

    * * * * *

    139 Use of the “special arrangement” proper shipping names for international shipments must be made under an IAEA Certificate of Competent Authority issued by the Associate Administrator in accordance with the requirements in § 173.471, § 173.472, or § 173.473 of this subchapter. Use of these proper shipping names for domestic shipments may be made only under a DOT exemption, as defined in, and in accordance with the requirements of subpart B of part 107 of this subchapter.

    * * * * *

    142 These hazardous materials may not be classified and transported unless authorized by the Associate Administrator. The Associate Administrator will base the authorization on results from Series 2 tests and a Series 6(c) test from the UN Manual of Tests and Criteria (see § 171.7 of this subchapter) on packages as prepared for transport in accordance with the requirements of this subchapter.

    143 These articles may contain:

    a. Division 2.2 compressed gases, including oxygen;

    b. Signal devices (Class 1) which may include smoke and illumination signal flares. Signal devices must be packed in plastic or fiberboard inner packagings;

    c. Electric storage batteries;

    d. First aid kits; or

    e. Strike anywhere matches.

    (2) * * *

    Code/Special Provisions

    * * * * *

    A53 Refrigerating machines and refrigerating machine components are not subject to the requirements of this subchapter when containing less than 12 kg (26.4 pounds) of a non-flammable gas or when containing 12 L (3 gallons) or less of ammonia solution (UN2672) (see § 173.307 of this subchapter).

    (3) “B” codes. These provisions apply only to bulk packagings, other than IBCs:

    Code/Special Provisions

    * * * * *

    B53 Packagings must be made of either aluminum or steel.

    * * * * *

    B69 Dry sodium cyanide or potassium cyanide may be shipped in sift-proof weather-resistant metal covered hopper cars, covered motor vehicles, portable tanks or non-specification bins. Siftproof, water-resistant, fiberboard IBCs are permitted when transported in closed freight containers or transport vehicles. Bins must be approved by the Associate Administrator.

    * * * * *

    (4) Table 1, Table 2, and Table 3—IB Codes, Organic Peroxide IBC Code, and IP Special IBC Packing Provisions. These provisions apply only to transportation in IBCs. IBCs may be used for the transportation of hazardous materials when no IBC code is assigned in the § 172.101 Table for the specific material only when approved by the Associate Administrator. Tables 1, 2, and 3 follow:Start Printed Page 33415

    Table 1.—IB Codes (IBC Codes)

    IBC CodeAuthorized IBCs
    IB1Authorized IBCs: Metal (31A, 31B and 31N).
    Additional Requirement: Only liquids with a vapor pressure less than or equal to 110 kPa at 50°C (1.1 bar at 122°F), or 130 kPa at 55°C (1.3 bar at 131°F) are authorized.
    IB2Authorized IBCs: Metal (31A, 31B and 31N); Rigid plastics (31H1 and 31H2); Composite (31HZ1).
    Additional Requirement: Only liquids with a vapor pressure less than or equal to 110 kPa at 50°C (1.1 bar at 122°F), or 130kPa at 55°C (1.3 bar at 131°F) are authorized.
    IB3Authorized IBCs: Metal (31A, 31B and 31N); Rigid plastics (31H1 and 31H2); Composite (31HZ1 and 31HA2, 31HB2, 31HN2, 31HD2 and 31HH2).
    Additional Requirement: Only liquids with a vapor pressure less than or equal to 110 kPa at 50°C (1.1 bar at 122°F), or 130 kPa at 55°C (1.3 bar at 131 °F) are authorized.
    IB4Authorized IBCs: Metal (11A, 11B, 11N, 21A, 21B, 21N, 31A, 31B and 31N).
    IB5Authorized IBCs: Metal (11A, 11B, 11N, 21A, 21B, 21N, 31A, 31B and 31N); Rigid plastics (11H1, 11H2, 21H1, 21H2, 31H1 and 31H2); Composite (11HZ1, 21HZ1 and 31HZ1).
    IB6Authorized IBCs: Metal (11A, 11B, 11N, 21A, 21B, 21N, 31A, 31B and 31N); Rigid plastics (11H1, 11H2, 21H1, 21H2, 31H1 and 31H2); Composite (11HZ1, 11HZ2, 21HZ1, 21HZ2, 31HZ1 and 31HZ2).
    Additional Requirement: Composite IBCs 11HZ2 and 21HZ2 may not be used when the hazardous materials being transported may become liquid during transport.
    IB7Authorized IBCs: Metal (11A, 11B, 11N, 21A, 21B, 21N, 31A, 31B and 31N); Rigid plastics (11H1, 11H2, 21H1, 21H2, 31H1 and 31H2); Composite (11HZ1, 11HZ2, 21HZ1, 21HZ2, 31HZ1 and 31HZ2); Wooden (11C, 11D and 11F).
    Additional Requirement: Liners of wooden IBCs must be sift-proof.
    IB8 Authorized IBCs: Metal (11A, 11B, 11N, 21A, 21B, 21N, 31A, 31B and 31N); Rigid plastics (11H1, 11H2, 21H1, 21H2, 31H1 and 31H2); Composite (11HZ1, 11HZ2, 21HZ1, 21HZ2, 31HZ1 and 31HZ2); Fiberboard (11G); Wooden (11C, 11D and 11F); Flexible (13H1, 13H2, 13H3, 13H4, 13H5, 13L1, 13L2, 13L3, 13L4, 13M1 or 13M2).
    IB99IBCs are only authorized if approved by the Associate Administrator.

    Table 2.—Organic Peroxide IBC Code (IB52)

    [This IBC Code applies to organic peroxides of type F. For formulations not listed in this table, only IBCs that are approved by the Associate Administrator may be used.]

    UN No.Organic peroxideType of IBCMaximum quantity (liters)Control temperatureEmergency temperature
    3109ORGANIC PEROXIDE, TYPE F, LIQUID
    tert-Butyl hydroperoxide, not more than 72% with water31A1250
    tert-Butyl peroxyacetate, not more than 32% in diluent type A31A 31HA11250 1000
    tert-Butyl peroxy-3,5,5-trimethylhexanoate, not more than 32% in diluent type A31A 31HA11250 1000
    Cumyl hydroperoxide, not more than 90% in diluent type A31HA11250
    Dibenzoyl peroxide, not more than 42% as a stable dispersion31H11000
    Di-tert-butyl peroxide, not more than 52% in diluent type A31A 31HA11250 1000
    1,1-Di-(tert-butylperoxy) cyclohexane, not more than 42% in diluent type A31H11000
    Dilauroyl peroxide, not more than 42%, stable dispersion, in water31HA11000
    Isopropyl cumyl hydroperoxide, not more than 72% in diluent type A31HA11250
    p-Menthyl hydroperoxide, not more than 72% in diluent type A31HA11250
    Peroxyacetic acid, stabilized, not more than 17%31H1 31HA1 31A1500 1500 1500
    3110Organic peroxide type F, solid31A 31H1 31HA1
    Dicumyl peroxide31A 31H1 31HA1
    3119ORGANIC PEROXIDE, TYPE F, LIQUID, TEMPERATURE CONTROLLED
    tert-Butyl peroxy-2-ethylhexanoate, not more than 32% in diluent type B31HA1 31A1000 1250+30°C +30°C+35°C +35°C
    tert-Butyl peroxyneodecanoate, not more than 32% in diluent type A31A12500°C+10°C
    tert-Butyl peroxyneodecanoate, not more than 42% stable dispersion, in water31A1250−5°C+5°C
    tert-Butyl peroxypivalate, not more than 27% in diluent type B31HA1 31A1000 1250+10°C +10°C+15°C +15°C
    Cumyl peroxyneodecanoate, not more than 52%, stable dispersion, in water31A1250−15°C−5°C
    Di-(4-tert-butylcyclohexyl) peroxydicarbonate, not more than 42%, stable dispersion, in water31HA11000+30°C+35°C
    Dicetyl peroxydicarbonate, not more than 42%, stable dispersion, in water31HA11000+30°C+35°C
    Di-(2-ethylhexyl) peroxydicarbonate, not more than 52%, stable dispersion, in water31A1250−20°C−10°C
    Dimyristyl peroxydicarbonate, not more than 42%, stable dispersion, in water31HA11000+15°C+20°C
    Start Printed Page 33416
    Di-(3,5,5-trimethylhexanoyl) peroxide, not more than 38% in diluent type A31HA1 31A1000 1250+10°C +10°C+15°C +15°C
    Di-(3,5,5-trimethylhexanoyl) peroxide, not more than 52%, stable dispersion, in water31A1250+10°C+15°C
    1,1,3,3-Tetramethylbutyl peroxyneodecanoate, not more than 52%, stable dispersion, in water31A1250−5°C+5°C

    Table 3.—IP Codes

    IP1 IBCs must be packed in closed freight containers or a closed transport vehicle.
    IP2 When IBCs other than metal or rigid plastics IBCs are used, they must be offered for transportation in a closed freight container or a closed transport vehicle.
    IP3 Flexible IBCs must be sift-proof and water-resistant or must be fitted with a sift-proof and water-resistant liner.
    IP4 Flexible, fiberboard or wooden IBCs must be sift-proof and water-resistant or be fitted with a sift-proof and water-resistant liner.
    IP5 IBCs must have a device to allow venting. The inlet to the venting device must be located in the vapor space of the IBC under maximum filling conditions.
    IP6 Non-specification bulk bins are authorized.
    IP7 For UN identification numbers 1327, 1363, 1364, 1365, 1386, 1841, 2211, 2217, 2793 and 3314, IBCs are not required to meet the IBC performance tests specified in part 178, subpart N of this subchapter.
    * * * * *

    (7) “T” codes. (i) These provisions apply to the transportation of hazardous materials in UN portable tanks. Portable tank instructions specify the requirements applicable to a portable tank when used for the transportation of a specific hazardous material. These requirements must be met in addition to the design and construction specifications in part 178 of this subchapter. Portable tank instructions T1 through T22 specify the applicable minimum test pressure, the minimum shell thickness (in reference steel), bottom opening requirements and pressure relief requirements. In T23, the organic peroxides and self-reactive substances which are authorized to be transported in portable tanks are listed along with the applicable control and emergency temperatures. Liquefied compressed gases are assigned to portable tank instruction T50. T50 provides the maximum allowable working pressures, bottom opening requirements, pressure relief requirements and degree of filling requirements for liquefied compressed gases permitted for transport in portable tanks. Refrigerated liquefied gases which are authorized to be transported in portable tanks are specified in tank instruction T75.

    (ii) The following table specifies the portable tank requirements applicable to T Codes T1 through T22. Column 1 specifies the T Code. Column 2 specifies the minimum test pressure, in bar (1 bar = 14.5 psig), at which the periodic hydrostatic testing required by § 180.605 of this subchapter must be conducted. Column 3 specifies the section reference for minimum shell thickness or, alternatively, the minimum shell thickness value. Column 4 specifies the applicability of § 178.275(g)(3) of this subchapter for the pressure relief devices. When the word “Normal” is indicated, § 178.275(g)(3) of this subchapter does not apply. Column 5 references the applicable requirements for bottom openings in part 178 of this subchapter or references “Prohibited” which means bottom openings are prohibited. The table follows:

    Table of Portable Tank T Coder T1-T22

    [Portable tank code T1-T22 apply to liquid and solid hazardous materials of Classes 3 through 9 which are transported in portable tanks.]

    Portable tank instructionMinimum test pressure (bar)Minimum shell thickness (in mm-reference steel) (See § 178.274(d))Pressure-relief requirements (See § 178.275(g))Bottom opening requirements (See § 178.275(d))
    (1)(2)(3)(4)(5)
    T11.5§ 178.274(d)(2)Normal§ 178.275(d)(2).
    T21.5§ 178.274(d)(2)Normal§ 178.275(d)(3).
    T32.65§ 178.274(d)(2)Normal§ 178.275(d)(2).
    T42.65§ 178.274(d)(2)Normal§ 178.275(d)(3).
    T52.65§ 178.274(d)(2)§ 178.275(g)(3)Prohibited.
    T64§ 178.274(d)(2)Normal§ 178.275(d)(2).
    T74§ 178.274(d)(2)Normal§ 178.275(d)(3).
    T84§ 178.274(d)(2)NormalProhibited.
    T946 mmNormalProhibited.
    T1046 mm§ 178.275(g)(3)Prohibited.
    T116§ 178.274(d)(2)Normal§ 178.275(d)(3).
    T126§ 178.274(d)(2)§ 178.275(g)(3)§ 178.275(d)(3).
    Start Printed Page 33417
    T1366 mmNormalProhibited.
    T1466 mm§ 178.275(g)(3)Prohibited.
    T1510§ 178.274(d)(2)Normal§ 178.275(d)(3).
    T1610§ 178.274(d)(2)§ 178.275(g)(3)§ 178.275(d)(3).
    T17106 mmNormal§ 178.275(d)(3).
    T18106 mm§ 178.275(g)(3)§ 178.275(d)(3).
    T19106 mm§ 178.275(g)(3)Prohibited.
    T20108 mm§ 178.275(g)(3)Prohibited.
    T211010 mmNormalProhibited.
    T221010 mm§ 178.275(g)(3)Prohibited.

    (iii) The following table specifies the portable tank requirements applicable to T23 for self-reactive substances of Division 4.1 and organic peroxides of Division 5.2 which are authorized to be transported in portable tanks:

    Portable Tank Code T23

    [Portable tank code T23 applies to self-reactive substances of Division 4.1 and organic peroxides of Division 5.2.]

    UN No.Hazardous materialMinimum test pressure (bar)Minimum shell thickness (mm-reference steel) See . . .Bottom opening requirements See . . .Pressure-relief requirements See . . .Filling limitsControl tempereature
    3109Organic peroxide, Type F, liquid4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)
    tert-Butyl hydroperoxide, not more than 72% with water. *Provided that steps have been taken to achieve the safety equivalence of 65% tert-Butyl hydroperoxide and 35% water4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)
    Cumyl hydro-peroxide, not more than 90% in diluent type A4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)
    Di-tert-butyl peroxide, not more than 32% in diluent type A4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)
    Isopropyl cumyl hydro-peroxide, not more than 72% in diluent type A4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)
    p-Menthyl hydro-peroxide, not more than 72% in diluent type A4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)
    Pinanyl hydro-peroxide, not more than 50% in diluent type A4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)
    3110Organic peroxide, Type F, solid4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)
    Dicumyl peroxide. *Maximum quantity per portable tank 2,000 kg
    3119Organic peroxide, Type F, liquid, temperature controlled4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)As approved by Assoc. Admin.
    tert-Butyl peroxyacetate, not more than 32% in diluent tyupe B4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)+30°C
    tert-Butyl peroxy-2-ethylhexanoate, not more than 32% in diluent type B4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)+15°C
    tert-Butyl peroxypivalate, not more than 27% in diluent type B4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)−5°C
    Start Printed Page 33418
    tert-Butyl peroxy-3,5,5-trimethyl-hexanoate, not more than 32% in dileunt type B4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)+35°C
    Di-(3,5,5-trimethyl-hexanoyl) peroxide, not more htan 38% in diluent type A4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)0°C
    3120Organix peroxide, Type F, solid, temperature controlled4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)As approved by Assoc. Admin.
    3229Self-reactive liquid Type F4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)
    3230Self-reactive solid Type F4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)
    3239Self-reactive liquid Type F, temperature controlled4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)As approved by Assoc. Admin.
    3240Self-reactive solid Type F, temperature controlled4§ 178.274(d)(2)§ 178.275(d)(3)§ 178.275(g)(1)Not more than 90% at 59° F (15°C)As approved by Assoc. Admin.

    (iv) The following portable tank instruction applies to portable tanks used for the transportation of liquefied compressed gases. The T50 table provides the UN identification number and proper shipping name for each liquefied compressed gas authorized to be transported in a T50 portable tank. The table provides maximum allowable working pressures, bottom opening requirements, pressure relief device requirements and degree of filling requirements for each liquefied compressed gases permitted for transportation in a T50 portable tank. In the minimum test pressure column, “small” means a portable tank with a diameter of 1.5 meters or less when measured at the widest part of the shell, “sunshield” means a portable tank with a shield covering at least the upper third of the shell, “bare” means no sunshield or insulation is provided, and “insulated” means a complete cladding of sufficient thickness of insulating material necessary to provide a minimum conductance of not more than 0.67 w/m2/k. In the pressure relief requirements column, the word “Normal” denotes that a frangible disc as specified in § 178.276(e)(3) of this subchapter is not required. The T50 table follows:

    Portable Tank Code T50

    [Portable tank code T50 applies to liquefied compressed gases.]

    UN No.Non-refrigerated liquefied compressed gasesMax. allowable working pressure (bar) small; bare; sunshield; insulatedOpenings below liquid levelPressure relief requirements (see § 178.27(e))Maximum filling density (kg/l)
    1005Ammonia, anhydrous29.0 25.7 22.0 19.7Allowed§ 178.276(e)(3)0.53
    1009Bromotrifluoromethane or Refrigerant gas R 13B138.0 34.0 30.0 27.5AllowedNormal1.13
    1010Butadienes, stabilized7.5 7.0 7.0 7.0AllowedNormal0.55
    1011Butane7.0 7.0 7.0 7.0AllowedNormal0.51
    Start Printed Page 33419
    1012Butylene8.0 7.0 7.0 7.0AllowedNormal0.53
    1017Chlorine19.0 17.0 15.0 13.5Not Allowed§ 178.276(e)(3)1.25
    1018Chlorodifluoromethane or Refrigerant gas R 2226.0 24.0 21.0 19.0AllowedNormal1.03
    1020Chloropentafluoroethane or Refrigerant gas R 11523.0 20.0 18.0 16.0AllowedNormal1.06
    10211-Chloro-1,2,2,2-tetrafluoroethane or Refrigerant gas R 12410.3 9.8 7.9 7.0AllowedNormal1.2
    1027Cyclopropane18.0 16.0 14.5 13.0AllowedNormal0.53
    1028Dichlorodifluoromethane or Refrigerant gas R 1216.0 15.0 13.0 11.5AllowedNormal1.15
    1029Dichlorofluoromethane or Refrigerant gas R 217.0 7.0 7.0 7.0AllowedNormal1.23
    10301,1-Difluoroethane or Refrigerant gas R 152a16.0 14.0 12.4 11.0AllowedNormal0.79
    1032Dimethylamine, anhydrous7.0 7.0 7.0 7.0AllowedNormal0.59
    1033Dimethyl ether15.5 13.8 12.0 10.6AllowedNormal0.58
    1036Ethylamine7.0 7.0 7.0 7.0AllowedNormal0.61
    1037Ethyl chloride7.0 7.0 7.0 7.0AllowedNormal0.8
    Start Printed Page 33420
    1040Ethylene oxide with nitrogen up to a total pressure of 1MPa (10 bar) at 50 °COnly authorized in 10 bar insulated portable tanksNot allowed§ 178.276(e)(3)0.78
    1041Ethylene oxide and carbon dioxide mixture with more than 9% but not more than 87% ethylene oxideSee MAWP defination in § 178.276(a)AllowedNormalSee § 173.32(f)
    1055Isobutylene8.1 7.0 7.0 7.0AllowedNormal0.52
    1060Methyl acetylene and propadiene mixture, stabilized28.0 24.5 22.0 20.0AllowedNormal0.43
    1061Methylamine, anhydrous10.8 9.6 7.8 7.0AllowedNormal0.58
    1062Methyl bromide7.0 7.0 7.0 7.0Not allowed§ 178.276(e)(3)1.51
    1063Methyl chloride or Refrigerant gas R 4014.5 12.7 11.3 10.0AllowedNormal0.81
    1064Methyl mercaptan7.0 7.0 7.0 7.0Not allowed§ 178.276(e)(3)0.78
    1067Dinitrogen tetroxide7.0 7.0 7.0 7.0Not allowed§ 178.276(e)(3)1.3
    1075Petroleum gas, liquefiedSee MAWP definition in § 178.276(a)AllowedNormalSee § 173.32(f)
    1077Propylene28.0 24.5 22.0 20.0AllowedNormal0.43
    1078Refrigerant gas, n.o.s.See MAWP definition in § 178.276(a)AllowedNormalSee § 173.32(f)
    1079Sulphur dioxide11.6 10.3 8.5 7.6Not allowed§ 178.276(e)(3)1.23
    1082Trifluorochloroethylene, stabilized or Refrigerant gas R 111317.0 15.0 13.1 11.6Not allowed§ 178.276(e)(3)1.13
    Start Printed Page 33421
    1083Trimethylamine, anhydrous7.0 7.0 7.0 7.0AllowedNormal0.56
    1085Vinyl bromide, stabilized7.0 7.0 7.0 7.0AllowedNormal1.37
    1086Vinyl chloride, stabilized10.6 9.3 8.0 7.0AllowedNormal0.81
    1087Vinyl methyl ether, stabilized7.0 7.0 7.0 7.0AllowedNormal0.67
    1581Chloropicrin and methyl bromide mixture7.0 7.0 7.0 7.0Not Allowed§ 178.276(e)(3)1.51
    1582Chloropicrin and methyl chloride mixture19.2 16.9 15.1 13.1Not allowed§ 178.276(e)(3)0.81
    1858Hexafluoropropylene compressed or Refrigerant gas R 121619.2 16.9 15.1 13.1AllowedNormal1.11
    1912Methyl chloride and methylene chloride mixture15.2 13.0 11.6 10.1AllowedNormal0.811954
    NA 1954Insecticide gases, flammable, n.o.s.See MAWP definition in § 178.276(a)AllowedNormal§ 173.32(f)
    19581,2-Dichloro-1,1,2,2-tetrafluoroethane or Refrigerant gas R 1147.0 7.0 7.0 7.0AllowedNormal1.3
    1965Hydrocarbon gas, mixture liquefied, n.o.s.See MAWP definition in 178.276(a)AllowedNormalSee § 173.32(f)
    1969Isobutane8.5 7.5 7.0 7.0AllowedNormal0.49
    1973Chlorodifluoromethane and chloropentafluoroethane mixture with fixed boiling point, with approximately 49% chlorodifluoromethane or Refrigerant gas R 50228.3 25.3 22.8 20.3AllowedNormal1.05
    1974Chlorodifluorobromomethane or Refrigerant gas R 12B17.4 7.0 7.0 7.0AllowedNormal1.61
    Start Printed Page 33422
    1976Octafluorocyclobutane or Refrigerant gas RC 3188.8 7.8 7.0 7.0AllowedNormal1.34
    1978Propane22.5 20.4 18.0 16.5AllowedNormal0.42
    19831-Chloro-2,2,2-trifluoroethane or Refrigerant gas R 133a7.0 7.0 7.0 7.0AllowedNormal1.18
    20351,1,1-Trifluoroethane compressed or Refrigerant gas R 143a31.0 27.5 24.2 21.8AllowedNormal0.76
    2424Octafluoropropane or Refrigerant gas R 21823.1 20.8 18.6 16.6AllowedNormal1.07
    25171-Chloro-1,1-difluoroethane or Refrigerant gas R 142b8.9 7.8 7.0 7.0AllowedNormal0.99
    2602Dichlorodifluoromethane and difluoroethane azeotropic mixture with approximately 74% dichlorodifluoromethane or Refrigerant gas R 50020.0 18.0 16.0 14.5AllowedNormal1.01
    3057Trifluoroacetyl chloride14.6 12.9 11.3 9.9Not allowed§ 178.276(e)(3)1.17
    3070Ethylene oxide and dichlorodifluoromethane mixture with not more than 12.5% ethylene oxide14.0 12.0 11.0 9.0Allowed§ 178.276(e)(3)1.09
    3153Perfluoro (methyl vinyl ether)14.3 13.4 11.2 10.2AllowedNormal1.14
    31591,1,1,2-Tetrafluoroethane or Refrigerant gas R 134a17.7 15.7 13.8 12.1AllowedNormal1.04
    3161Liquefied gas, flammable, n.o.s.See MAWP definition in § 178.276(a)AllowedNormal§ 173.32(f)
    3163Liquefied gas, n.o.s.See MAWP definition in § 178.276(a)AllowedNormal§ 173.32(f)
    Start Printed Page 33423
    3220Pentafluoroethane or Refrigerant gas R 12534.4 30.8 27.5 24.5AllowedNormal0.95
    3252Difluoromethane or Refrigerant gas R 3243.0 39.0 34.4 30.5AllowedNormal0.78
    3296Heptafluoropropane or Refrigerant gas R 22716.0 14.0 12.5 11.0AllowedNormal1.2
    3297Ethylene oxide and chlorotetrafluoroethane mixture, with not more than 8.8% ethylene oxide8.1 7.0 7.0 7.0AllowedNormal1.16
    3298Ethylene oxide and pentafluoroethane mixture, with not more than 7.9% ethylene oxide25.9 23.4 20.9 18.6AllowedNormal1.02
    3299Ethylene oxide and tetrafluoroethane mixture, with not more than 5.6% ethylene oxide16.7 14.7 12.9 11.2AllowedNormal1.03
    3318Ammonia solution, relative density less than 0.880 at 15 °C in water, with more than 50% ammoniaSee MAWP definition in 178.276(a)Allowed§ 178.276(e)(3)§ 173.32(f)
    3337Refrigerant gas R 404A31.6 28.3 25.3 22.5AllowedNormal0.84
    3338Refrigerant gas R 407A31.3 28.1 25.1 22.4AllowedNormal0.95
    3339Refrigerant gas R 407B33.0 29.6 26.5 23.6AllowedNormal0.95
    3340Refrigerant gas R 407C29.9 26.8 23.9 21.3AllowedNormal0.95

    (v) When portable tank instruction T75 is referenced in Column (7) of the § 172.101 Table, the applicable refrigerated liquefied gases are authorized to be transported in portable tanks in accordance with the requirements of § 178.277 of this subchapter.

    (vi) UN and IM portable tank codes/special provisions. When a specific portable tank instruction is specified by a T Code in Column (7) of the § 172.101 Table for a specific hazardous material, a Specification portable tank conforming to an alternative tank instruction may be used if:

    (A) the alternative portable tank has a higher or equivalent test pressure (for example, 4 bar when 2.65 bar is specified);

    (B) the alternative portable tank has greater or equivalent wall thickness (for example, 10 mm when 6 mm is specified);

    (C) the alternative portable tank has a pressure relief device as specified in the T Code. If a frangible disc is required in series with the reclosing pressure relief device for the specified portable tank, the alternative portable tank must be fitted with a frangible disc in series with the reclosing pressure relief device; and

    (D) With regard to bottom openings—Start Printed Page 33424

    (1) When two effective means are specified, the alternative portable tank is fitted with bottom openings having two or three effective means of closure or no bottom openings; or

    (2) When three effective means are specified, the portable tank has no bottom openings or three effective means of closure; or

    (3) When no bottom openings are authorized, the alternative portable tank must ot have bottom openings.

    (vii) When a hazardous material is not assigned a portable tank T Code or TP 9 is referenced in Column (7) of the § 172.101 Table, the hazardous material may only be transported in a portable tank if approved by the Associate Administrator.

    (viii) Portable tank special provisions are assigned to certain hazardous materials to specify requirements that are in addition to those provided by the portable tank instructions or the requirements in part 178 of this subchapter. Portable tank special provisions are designated with the abbreviation TP (tank provision) and are assigned to specific hazardous materials in Column (7) of the § 172.101 Table. The following is a list of the portable tank special provisions:

    Code/Special Provisions

    TP1 The maximum degree of filling must not exceed the degree of filling determined by the following:

    Where:

    tr is the maximum mean bulk temperature during transport, and tf is the temperature in degrees celsius of the liquid during filling.

    TP2 a. The maximum degree of filling must not exceed the degree of filling determined by the following:

    Where:

    tr is the maximum mean bulk temperature during transport,

    tf is the temperature in degrees celsius of the liquid during filling, and

    α is the mean coefficient of cubical expansion of the liquid between the mean temperature of the liquid during filling (tf) and the maximum mean bulk temperature during transportation (tr) both in degrees celsius.

    b. For liquids transported under ambient conditions α may be calculated using the formula:

    Where:

    d15 and d50 are the densities (in units of mass per unit volume) of the liquid at 15°C (59°F) and 50°C (122°F), respectively.

    TP3 For liquids transported under elevated temperature, the maximum degree of filling is determined by the following:

    Where:

    dt is the density of the material at the maximum mean bulk temperature during transport; and

    df is the density of the material at the temperature in degrees celsius of the liquid during filling; and

    df is the density of the liquid at the mean temperature of the liquid during filling, and dt is the maximum mean bulk temperature during transport.

    TP4 The maximum degree of filling for portable tanks must not exceed 90%.

    TP5 For a portable tank used for the transport of flammable refrigerated liquefied gases or refrigerated liquefied oxygen, the maximum rate at which the portable tank may be filled must not exceed the liquid flow capacity of the primary pressure relief system rated at a pressure not exceeding 120 percent of the portable tank's design pressure. For portable tanks used for the transport of refrigerated liquefied helium and refrigerated liquefied atmospheric gas (except oxygen), the maximum rate at which the tank is filled must not exceed the liquid flow capacity of the pressure relief device rated at 130 percent of the portable tank's design pressure. Except for a portable tank containing refrigerated liquefied helium, a portable tank shall have an outage of at least two percent below the inlet of the pressure relief device or pressure control valve, under conditions of incipient opening, with the portable tank in a level attitude. No outage is required for helium.

    TP6 To prevent the tank from bursting in an event, including fire engulfment (the conditions prescribed in CGA pamphlet S-1.2 (see § 171.7 of this subchapter) may be used to consider the fire engulfment condition), it must be equipped with pressure relief devices that are adequate in relation to the capacity of the tank and the nature of the hazardous material transported.

    TP7 The vapor space must be purged of air by nitrogen or other means.

    TP8 A portable tank having a minimum test pressure of 1.5 bar (150 kPa) may be used when the flash point of the hazardous material transported is greater than 0°C (32°F).

    TP9 A hazardous material assigned to special provision TP9 in Column (7) of the § 172.101 Table may only be transported in a portable tank if approved by the Associate Administrator.

    TP10 The portable tank must be fitted with a lead lining at least 5 mm (0.2 inches) thick. The lead lining must be tested annually to ensure that it is intact and functional. Another suitable lining material may be used if approved by the Associate Administrator.

    TP12 This material is considered highly corrosive to steel.

    TP13 Self-contained breathing apparatus must be provided when this hazardous material is transported by sea.

    TP16 The portable tank must be protected against over and under pressurization which may be experienced during transportation. The means of protection must be approved by the approval agency designated to approve the portable tank in accordance with the procedures in part 107, subpart E, of this subchapter. The pressure relief device must be preceded by a frangible disk in accordance with the requirements in § 178.275(g)(3) of this subchapter to prevent crystallization of the product in the pressure relief device.

    TP17 Only inorganic non-combustible materials may be used for thermal insulation of the tank.

    TP18 The temperature of this material must be maintained between 18°C (64.4°F) and 40°C (104°F) while in transportation. Portable tanks containing solidified methacrylic acid must not be reheated during transportation.

    TP19 The calculated wall thickness must be increased by 3 mm at the time of construction. Wall thickness must be verified ultrasonically at intervals midway between periodic hydraulic tests (every 2.5 years). The portable tank must not be used if the wall thickness is less than that prescribed by the applicable T code in Column (7) of the Table for this material.

    TP20 This hazardous material must only be transported in insulated tanks under a nitrogen blanket.

    TP21 The wall thickness must not be less than 8 mm. Portable tanks must be hydraulically tested and internally inspected at intervals not exceeding 2.5 years.

    TP22 Lubricants for portable tank fittings (for example, gaskets, shut-off valves, flanges) must be oxygen compatible.

    TP24 The portable tank may be fitted with a device to prevent the build up of excess pressure due to the slow decomposition of the hazardous material being transported. The device must be in the vapor space when the tank is filled under maximum filling conditions. This device must also prevent an unacceptable amount of leakage of liquid in the case of overturning.

    TP25 Sulphur trioxide 99.95% pure and above may be transported in tanks without an inhibitor provided that it is maintained at a temperature equal to or above 32.5°C (90.5°F).

    TP26 The heating device must be exterior to the shell. For UN 3176, this requirement only applies when the hazardous material reacts dangerously with water.

    TP27 A portable tank having a minimum test pressure of 4 bar (400 kPa) may be used provided the calculated test pressure is 4 bar or less based on the MAWP of the hazardous material, as defined in § 178.275 of this subchapter, where the test pressure is 1.5 times the MAWP.

    TP28 A portable tank having a minimum test pressure of 2.65 bar (265 kPa) may be used provided the calculated test pressure is 2.65 bar or less based on the MAWP of the Start Printed Page 33425hazardous material, as defined in § 178.275 of this subchapter, where the test pressure is 1.5 times the MAWP.

    TP29 A portable tank having a minimum test pressure of 1.5 bar (150.0 kPa) may be used provided the calculated test pressure is 1.5 bar or less based on the MAWP of the hazardous materials, as defined in § 178.275 of this subchapter, where the test pressure is 1.5 times the MAWP.

    TP30 This hazardous material may only be transported in insulated tanks.

    TP31 This hazardous material may only be transported in tanks in the solid state.

    TP37 IM portable tanks are only authorized for the shipment of hydrogen peroxide solutions in water containing 72% or less hydrogen peroxide by weight. Pressure relief devices shall be designed to prevent the entry of foreign matter, the leakage of liquid and the development of any dangerous excess pressure. In addition, the portable tank must be designed so that internal surfaces may be effectively cleaned and passivated. Each tank must be equipped with pressure relief devices conforming to the following requirements:

    Concentration of hydrogen per peroxide solutionTotal 1
    52% or less11
    Over 52%, but not greater than 60%22
    Over 60%, but not greater than 72%32
    1 Total venting capacity in standard cubic feet hour (S.C.F.H.) per pound of hydrogen peroxide solution.

    TP38 Each portable tank must be insulated with an insulating material so that the overall thermal conductance at 15.5 °C (60 °F) is no more than 1.5333 kilojoules per hour per square meter per degree Celsius (0.075 Btu per hour per square foot per degree Fahrenheit) temperature differential. Insulating materials may not promote corrosion to steel when wet.

    TP44 Each portable tank must be made of stainless steel, except that steel other than stainless steel may be used in accordance with the provisions of § 173.24b(b) of this subchapter. Thickness of stainless steel for tank shell and heads must be the greater of 7.62 mm (0.300 inch) or the thickness required for a portable tank with a design pressure at least equal to 1.5 times the vapor pressure of the hazardous material at 46 °C (115 °F).

    TP45 Each portable tank must be made of stainless steel, except that steel other than stainless steel may be used in accordance with the provisions of 173.24b(b) of this subchapter. Thickness of stainless steel for portable tank shells and heads must be the greater of 6.35 mm (0.250 inch) or the thickness required for a portable tank with a design pressure at least equal to 1.3 times the vapor pressure of the hazardous material at 46 °C (115 °F).

    TP46 Portable tanks in sodium metal service are not required to be hydrostatically retested.

    (8) * * *

    Code/Special Provisions

    W7 Vessel stowage category for uranyl nitrate hexahydrate solution is “D” as defined in § 172.101(k)(4).

    W8 Vessel stowage category for pyrophoric thorium metal or pyrophoric uranium metal is “D” as defined in § 172.101(k)(4).

    W9 When offered for transportation by water, the following Specification packagings are not authorized unless approved by the Associate Administrator: woven plastic bags, plastic film bags, textile bags, paper bags, IBCs and bulk packagings.

    * * * * *
    Start Amendment Part

    14. In § 172.202, paragraphs (a)(4) and (e) are revised to read as follows:

    End Amendment Part
    Description of hazardous material on shipping papers.

    (a) * * *

    (4) The packing group in Roman numerals, as designated for the hazardous material in Column 5 of the § 172.101 Table. Class 1 (explosives) materials, self-reactive substances, organic peroxides and entries that are not assigned a packing group are excepted from this requirement. The packing group may be preceded by the letters “PG” (for example, “PG II”); and

    * * * * *

    (e) Except for those materials in the UN Recommendations, the ICAO Technical Instructions, or the IMDG Code (see § 171.7 of this subchapter), a material that is not a hazardous material according to this subchapter may not be offered for transportation or transported when its description on a shipping paper includes a hazard class or an identification number specified in the § 172.101 Table.

    Start Amendment Part

    15. In § 172.203, paragraph (d)(11) is revised, new paragraphs (i)(5) and (i)(6) are added, and paragraph (n) is revised to read as follows:

    End Amendment Part
    Additional description requirements.
    * * * * *

    (d) * * *

    (11) For a shipment of low specific activity material or surface contaminated objects, the appropriate group notation of LSA-I, LSA-II, LSA-III, SCO-I, or SCO-II, unless the group notation is contained in the proper shipping name as described in the § 172.101 Table.

    * * * * *

    (i) * * *

    (5) Minimum flash point if 61°C or below (in °C closed cup (c.c.) in association with the basic description.

    (6) Subsidiary hazards not communicated in the proper shipping name shown either following the hazard class or division in parentheses, or in association with the basic description.

    * * * * *

    (n) Elevated temperature materials. If a liquid material in a package meets the definition of an elevated temperature material in § 171.8 of this subchapter, and the fact that it is an elevated temperature material is not disclosed in the proper shipping name (for example, when the words “Molten” or “Elevated temperature” are part of the proper shipping name), the word “HOT” must immediately precede the proper shipping name of the material on the shipping paper.

    * * * * *
    [Amended]
    Start Amendment Part

    16. In § 172.330, in paragraph (a)(1)(ii), the following changes are made:

    End Amendment Part

    a. The proper shipping name, “Acrolein, inhibited” is revised to read “Acrolein, stabilized”.

    b. The proper shipping name, “Chloroprene, inhibited” is revised to read “Chloroprene, stabilized”.

    c. The proper shipping name, “Sulfur trioxide, inhibited” is revised to read “Sulfur trioxide, stabilized”.

    Start Amendment Part

    17. In § 172.402, paragraph (b) is revised to read as follows:

    End Amendment Part
    Additional labeling requirements.
    * * * * *

    (b) Display of hazard class on labels. The appropriate hazard class or division number must be displayed in the lower corner of a primary hazard label and a subsidiary hazard label. A subsidiary label meeting the specifications of this section which were in effect on September 30, 2001, such as, a label without the hazard class or division number displayed in the lower corner of the label) may continue to be used as a subsidiary label in domestic transportation by rail or highway until October 1, 2005, provided the color tolerances are maintained and are in accordance with the display requirements in this subchapter.

    * * * * *
    [Amended]
    Start Amendment Part

    18. In § 172.405, the following changes are made:

    End Amendment Part

    a. In paragraph (a) introductory text, the wording “subsidiary label when—” is removed and the wording “subsidiary label.” is added in its place.

    b. Paragraphs (a)(1) and (a)(2) are removed.

    Start Amendment Part

    19-20. In § 172.411, the section heading, the text of paragraph (c) preceding the labels, and paragraph (d) Start Printed Page 33426are revised and, in paragraph (c), the wording “EXPLOSIVE SUBSIDIARY LABEL:” and the explosive subsidiary label following it are removed, to read as follows:

    End Amendment Part

    § 172.411 EXPLOSIVE 1.1, 1.2, 1.3, 1.4, 1.5 and 1.6 labels.

    * * * * *

    (c) Except for size and color, the EXPLOSIVE 1.4, EXPLOSIVE 1.5 and EXPLOSIVE 1.6 labels must be as follows:

    * * * * *

    (d) In addition to complying with § 172.407, the background color on the EXPLOSIVE 1.4, EXPLOSIVE 1.5, EXPLOSIVE 1.6 and EXPLOSIVE subsidiary label must be orange. The “*” shall be replaced with the appropriate compatibility group. The compatibility group letter must be shown as a capitalized Roman letter. Division numerals must measure at least 30 mm (1.2 inches) in height and at least 5 mm (0.2 inches) in width.

    Start Amendment Part

    21. In § 172.502, paragraph (b)(1) is revised to read as follows:

    End Amendment Part
    Prohibited and permissive placarding.
    * * * * *

    (b) * * * (1) The restrictions in paragraph (a) of this section do not apply to a bulk packaging, freight container, unit load device, transport vehicle or rail car which is placarded in conformance with TDG Regulations, the IMDG Code or the UN Recommendations (see § 171.7 of this subchapter).

    * * * * *
    Start Amendment Part

    22. In § 172.504, in paragraph (g), a sentence is added at the end of the existing text and paragraphs (g)(1) through (g)(4) are added to read as follows:

    End Amendment Part
    General placarding requirements.
    * * * * *

    (g) * * * When more than one compatibility group placard is required for Class 1 materials, only one placard is required to be displayed as follows:

    (1) Explosive articles of compatibility groups C, D or E may be placarded displaying compatibility group E.

    (2) Explosive articles of compatibility groups C, D, E or N may be placarded displaying compatibility group D.

    (3) Explosive substances of compatibility groups C and D may be placarded displaying compatibility group D.

    (4) Explosive articles of compatibility groups C, D, E or G, except for fireworks, may be placarded displaying compatibility group E.

    [Amended]
    Start Amendment Part

    23. In § 172.512, in paragraph (a)(3), the wording “ICAO Technical Instructions” is removed and “ICAO Technical Instructions (see § 171.7 of this subchapter)” is added in its place.

    End Amendment Part Start Amendment Part

    24. In § 172.519, paragraph (b)(4) is revised to read as follows:

    End Amendment Part
    General specifications for placards.
    * * * * *

    (b) * * *

    (4) For a placard corresponding to the primary or subsidiary hazard class of a material, the hazard class or division number must be displayed in the lower corner of the placard. However, a permanently affixed subsidiary placard meeting the specifications of this section which were in effect on September 30, 2001, (such as, a placard without the hazard class or division number displayed in the lower corner of the placard) and which was installed prior to September 30, 2001, may continue to be used as a subsidiary placard in domestic transportation by rail or highway, provided the color tolerances are maintained and are in accordance with the display requirements in this subchapter. Stocks of non-permanently affixed subsidiary placards in compliance with the requirements in effect on September 30, 2001, may continue to be used in domestic transportation by rail or highway until October 1, 2005, or until current stocks are depleted, whichever occurs first.

    * * * * *
    Start Part

    PART 173—SHIPPERS—GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS

    End Part Start Amendment Part

    25. The authority citation for part 173 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 49 U.S.C. 5101-5127, 44701; 49 CFR 1.53.

    End Authority Start Amendment Part

    26. In § 173.2a, in paragraph (b), in the Precedence of Hazard Table, in the first column, the first three entries are amended by adding a footnote reference “ 2” immediately following “I”, “II”, and “III”, respectively, and footnote 2 at the end of the Precedence of Hazard Table is revised to read as follows:

    End Amendment Part
    Classification of a material having more than one hazard.
    * * * * *

    (b) * * *

    Precedence of Hazard Table

    *    *    *    *    *
    *    *    *    *    *
    *    *    *    *    *
    2 Materials of Division 4.1 other than self-reactive substances and solid desensitized explosives, and materials of Class 3 other than liquid desensitized explosives.
    * * * * *
    Start Amendment Part

    27. In § 173.4, paragraph (a)(1) introductory text is revised to read as follows:

    End Amendment Part
    Small quantity exceptions.

    (a) * * *

    (1) The maximum quantity of material per inner receptacle or article is limited to—

    * * * * *
    Start Amendment Part

    28. In § 173.24b, paragraph (e) is added to read as follows:

    End Amendment Part
    Additional general requirements for bulk packagings.
    * * * * *

    (e) UN portable tanks. (1) A UN portable tank manufactured in the United States must conform in all details to the applicable requirements in parts 172, 173, 178 and 180 of this subchapter.

    (2) UN portable tanks manufactured outside the United States. A UN portable tank manufactured outside the United States, in accordance with national or international regulations based on the UN Recommendations on the Transport of Dangerous Goods which is an authorized packaging under § 173.24 of this subchapter, may be filled, offered and transported in the United States, if the § 172.101 Table of this subchapter authorizes the hazardous material for transportation in the UN portable tank and it conforms to the applicable T codes, and tank provision codes, or other special provisions assigned to the hazardous material in Column (7) of the Table when manufactured in a country other than the United States. In addition, the portable tank must be—

    (i) Conform to applicable provisions in the UN Recommendations on the Transport of Dangerous Goods (see § 171.7 of this subchapter) and the requirements of this subpart;

    (ii) Be capable of passing the prescribed tests and inspections in part 180 of this subchapter applicable to the UN portable tank specification;

    (iii) Be designed and manufactured according to the ASME Code (see § 171.7 of this subchapter) or a pressure vessel design code approved by the Associate Administrator;

    (iv) Be approved by the Associate Administrator when the portable tank is Start Printed Page 33427designed and constructed under the provisions of an alternative arrangement (see § 178.274(a)(2) of this subchapter); and

    (v) The competent authority of the country of manufacture must provide reciprocal treatment for UN portable tanks manufactured in the United States.

    [Amended]
    Start Amendment Part

    29. In § 173.31, in paragraph (b)(2)(ii), in the first sentence, the wording “chloroprene, inhibited” is revised to read “chloroprene, stabilized'.

    End Amendment Part Start Amendment Part

    30. Section 173.32 is revised to read as follows:

    End Amendment Part
    Requirements for the use of portable tanks.

    (a) General requirements. No person may offer a hazardous material for transportation in a portable tank except as authorized by this subchapter.

    (1) Except as otherwise provided in this subpart, no person may use a portable tank for the transportation of a hazardous material unless it meets the requirements of this subchapter.

    (2) No person may fill and offer for transportation a portable tank when the prescribed periodic test or inspection under subpart G of part 180 of this subchapter has become due until the test or inspection has been successfully completed. This requirement does not apply to any portable tank filled prior to the test or inspection due date.

    (3) When a portable tank is used as a cargo tank motor vehicle, it must conform to all the requirements prescribed for cargo tank motor vehicles. (See § 173.33.)

    (b) Substitute packagings. A particular Specification portable tank may be substituted for another portable tank as follows:

    (1) An IM or UN portable tank may be used whenever an IM or UN portable tank having less stringent requirements is authorized provided the portable tank meets or exceeds the requirements for pressure-relief devices, bottom outlets and any other special provisions specified in § 172.102(c)(7)(vi) of this subchapter.

    (2) Where a Specification IM101 or IM102 portable tank is prescribed, a UN portable tank or Specification 51 portable tank otherwise conforming to the special commodity requirements of § 172.102(c)(7) of this subchapter for the material to be transported may be used.

    (3) A DOT Specification 51 portable tank may be used whenever a DOT Specification 56, 57, or 60 portable tank is authorized. A DOT Specification 60 portable tank may be used whenever a DOT Specification 56 or 57 portable tank is authorized. A higher integrity tank used instead of a specified portable tank must meet the same design profile; for example, a DOT Specification 51 portable tank must be lined if used instead of a lined DOT Specification 60 portable tank.

    (c) Grandfather provisions for portable tanks— (1) Continued use of Specification 56 and 57 portable tanks. Continued use of an existing portable tank constructed to DOT Specification 56 or 57 is authorized only for a portable tank constructed before October 1, 1996. A stainless steel portable tank internally lined with polyethylene that was constructed on or before October 1, 1996, and that meets all requirements of DOT Specification 57 except for being equipped with a polypropylene discharge ball valve and polypropylene secondary discharge opening closure, may be marked as a Specification 57 portable tank and used in accordance with the provisions of this section.

    (2) A DOT Specification 51, IM 101, or IM 102 portable tank may not be manufactured after January 1, 2003; however, such tanks may continue to be used for the transportation of a hazardous material provided they meet the requirements of this subchapter, including the specification requirements and the requirements of this subchapter for the transportation of the particular hazardous material (see § 171.14(d)(4) of this subchapter), and provided it conforms to the periodic inspection and tests specified for the particular portable tank in subpart G of part 180 of this subchapter. After January 1, 2003, all newly manufactured portable tanks must conform to the requirements for the design, construction and approval of UN portable tanks as specified in §§ 178.273, 178.274, 178.275, 178.276, 178.277 and part 180, subpart G, of this subchapter.

    (3) A DOT Specification portable tank manufactured prior to January 1, 1992 that is equipped with a non-reclosing pressure relief device may continue in service for the hazardous materials for which it is authorized. Except for a DOT Specification 56 or 57 portable tank, a DOT Specification portable tank manufactured after January 1, 1992, used for materials meeting the definition for Division 6.1 liquids, Packing Group I or II, Class 2 gases, or Class 3 or 4 liquids, must be equipped with a reclosing pressure relief valve having adequately sized venting capacity unless otherwise specified in this subchapter (see §§ 178.275(f)(4) and 178.277 of this subchapter).

    (4) Any portable tank container constructed prior to May 15, 1950, complying with the requirements of either the ASME Code for Unfired Pressure Vessels, 1946 Edition, or the API ASME Code for Unfired Pressure Vessels, 1943 Edition (see § 171.7 of this subchapter), may be used for the transportation of liquefied compressed gas, provided it fulfills all the requirements of the part and specifications for the particular gas or gases to be transported. Such portable tanks must be marked “ICC Specification 51X” on the plate required by the specification, except as modified by any or all of the following:

    (i) Portable tanks designed and constructed in accordance with Pars. U-68, U-69, or U-201 of the ASME Code (see § 171.7 of this subchapter) may be used. Portable tanks designed and constructed in accordance with Par. U-68 or Par. U-69 may be re-rated at a working pressure 25 percent in excess of the design pressure for which the portable tank was originally constructed. If the portable tank is re-rated, the re-rated pressure must be marked on the plate as follows: “Re-rated working pressure—psig”.

    Note to Paragraph (c)(4)(i):

    For purposes of setting safety relief valves, pressure control valves, establishing retest pressure and maximum and minimum design pressures, the re-rated working pressure must be considered as the equivalent of the design pressure as defined in the specification.

    (ii) Loading and unloading accessories, valves, piping, fittings, safety and gauging devices, do not have to comply with the requirements for the particular location on the portable tank.

    (5) Any ICC Specification 50 portable tank fulfilling the requirements of that specification may be continued in service for transportation of a liquefied petroleum gas if it is retested every five years in accordance with the requirements in § 180.605 of this subchapter. Use of existing portable tanks is authorized. New construction is not authorized.

    (d) Determination of an authorized portable tank. Prior to filling and offering a portable tank for transportation, the shipper must ensure that the portable tank conforms to the authorized specification and meets the applicable requirements in this subchapter for the hazardous material. The shipper must ensure that the MAWP, design pressure or test pressure of the portable tank, as applicable, is appropriate for the hazardous material being transported. Determination of the applicable pressure must take into account the maximum pressure used to load or unload the hazardous material, the vapor pressure, static head and surge pressures of the hazardous Start Printed Page 33428material and the temperatures that the hazardous material will experience during transportation.

    (e) External inspection prior to filling. Each portable tank must be given a complete external inspection prior to filling. Any unsafe condition must be corrected prior to its being filled and offered for transportation. The external inspection shall include a visual inspection of:

    (1) The shell, piping, valves and other appurtenances for corroded areas, dents, defects in welds and other defects such as missing, damaged, or leaking gaskets;

    (2) All flanged connections or blank flanges for missing or loose nuts and bolts;

    (3) All emergency devices for corrosion, distortion, or any damage or defect that could prevent their normal operation;

    (4) All required markings on the tank for legibility; and

    (5) Any device for tightening manhole covers to ensure such devices are operative and adequate to prevent leakage at the manhole cover.

    (f) Loading requirements. (1) A hazardous material may not be loaded into a portable tank if the hazardous material would:

    (i) Damage the portable tank;

    (ii) React with the portable tank; or

    (iii) Otherwise compromise its product retention capability.

    (2) A hazardous material may not be loaded in a DOT Specification 51, DOT Specification 60, an IM or UN portable tank unless the portable tank has a pressure relief device that provides total relieving capacity meeting the requirements of this subchapter.

    (3) Except during a pressure test, a portable tank may not be subjected to a pressure greater than its marked maximum allowable working pressure or, when appropriate, its marked design pressure.

    (4) A portable tank may not be loaded to a gross mass greater than the maximum allowable gross mass specified on its identification plate.

    (5) Except for a non-flowable solid or a liquid with a viscosity of 2,680 centistokes (millimeters squared per second) or greater at 20°C (68°F), an IM or UN portable tank, or compartment thereof, having a volume greater than 7,500 L (1,980 gallons) may not be loaded to a filling density of more than 20% and less than 80% by volume. This filling restriction does not apply if a portable tank is divided by partitions or surge plates into compartments of not more than 7,500 L (1,980 gallons) capacity; this portable tank must not be offered for transportation in an ullage condition liable to produce an unacceptable hydraulic force due to surge.

    (6) The outage for a portable tank may not be less than 2% at a temperature of 50 °C (122 °F) unless otherwise specified in this subchapter. For UN portable tanks, the applicable maximum filling limits apply as specified according to the assigned TP codes in Column (7) of the § 172.101 Table of this subchapter except when transported domestically.

    (7) Each tell-tale indicator or pressure gauge located in the space between a frangible disc and a safety relief valve mounted in series must be checked after the tank is filled and prior to transportation to ensure that the frangible disc is leak free. Any leakage through the frangible disc must be corrected prior to offering the tank for transportation.

    (8) During filling, the temperature of the hazardous materials shall not exceed the limits of the design temperature range of the portable tank.

    (9) The maximum mass of liquefied compressed gas per liter (gallon) of shell capacity (kg/L or lbs./gal.) may not exceed the density of the liquefied compressed gas at 50 °C (122 °F). The portable tank must not be liquid full at 60 °C (140 °F).

    (g) Additional requirements for specific modal transport. In addition to other applicable requirements, the following apply:

    (1) A portable tank containing a hazardous material may not be loaded on to a highway or rail transport vehicle unless loaded entirely within the horizontal outline thereof, without overhang or projection of any part of the tank assembly. In addition, for unloading a portable tank, see § 177.834(i)(2) of this subchapter.

    (2) An IM or UN portable tank used for the transportation of flammable liquids by rail may not be fitted with non-reclosing pressure relief devices except in series with reclosing pressure relief valves.

    (3) A portable tank or Specification 106A or 110A multi-unit tank car containing a hazardous material may not be offered for transportation aboard a passenger vessel unless:

    (i) The vessel is operating under a change to its character of vessel certification as defined in § 171.8 of this subchapter; and

    (ii) The material is permitted to be transported aboard a passenger vessel in the § 172.101 Table of this subchapter.

    (h) Additional general commodity-specific requirements. In addition to other applicable requirements, the following requirements apply:

    (1) Each uninsulated portable tank used for the transportation of a liquefied compressed gas must have an exterior surface finish that is significantly reflective, such as a light-reflecting color if painted, or a bright reflective metal or other material if unpainted.

    (2) If a hazardous material is being transported in a molten state, the portable tank must be thermally insulated with suitable insulation material of sufficient thickness that the overall thermal conductance is not more than 0.080 Btu per hour per square foot per degree Fahrenheit differential.

    (i) Additional requirements for portable tanks other than IM specification and UN portable tanks. (1) The bursting strength of any piping and fittings must be at least four times the design pressure of the tank, and at least four times the pressure to which, in any instance, it may be subjected in service by the action of a pump or other device (not including safety relief valves) that may subject piping to pressures greater than the design pressure of the tank.

    (2) Pipe joints must be threaded, welded or flanged. If threaded pipe is used, the pipe and pipe fittings must not be lighter than Schedule 80 weight. Where copper tubing is permitted, joints must be brazed or be of equally strong metal union type. The melting point of brazing material may not be lower than 1,000 °F (537.8 °C). The method of joining tubing must not decrease the strength of the tubing such as by the cutting of threads.

    (3) Non-malleable metals may not be used in the construction of valves or fittings.

    (4) Suitable provision must be made in every case to allow for expansion, contraction, jarring and vibration of all pipe. Slip joints may not be used for this purpose.

    (5) Piping and fittings must be grouped in the smallest practicable space and must be protected from damage as required by the specification.

    (6) All piping, valves and fittings on every portable tank must be leakage tested with gas or air after installation and proved tight at not less than the design pressure of the portable tank on which they are used. In the event of replacement, all such piping, valves, or fittings must be tested in accordance with the requirements of this section before the portable tank is returned to transportation service. The requirements of this section apply to all hoses used on portable tanks, except that hoses may be tested either before or after installation on the portable tank.

    (7) All materials used in the construction of portable tanks and their appurtenances may not be subject to Start Printed Page 33429destructive attack by the contents of the portable tank.

    (8) No aluminum, copper, silver, zinc nor their alloys may be used. Brazed joints may not be used. All parts of a portable tank and its appurtenances used for anhydrous ammonia must be steel.

    (9) Each outlet of a portable tank used for the transportation of non-refrigerated liquefied compressed gases, except carbon dioxide, must be provided with a suitable automatic excess-flow valve (see definition in § 178.337-1(g) of this subchapter). The valve must be located inside the portable tank or at a point outside the portable tank where the line enters or leaves the portable tank. The valve seat must be located inside the portable tank or may be located within a welded flange or its companion flange, or within a nozzle or within a coupling. The installation must be made in such a manner as to reasonably assure that any undue strain which causes failure requiring functioning of the valve shall cause failure in such a manner that it will not impair the operation of the valve.

    (i) A safety device connection or liquid level gauging device that is constructed so that the outward flow of the tank contents will not exceed that passed by an opening of 0.1397 cm (0.0550 inches) is not required to be equipped with excess-flow valves.

    (ii) An excess-flow valve must close automatically if the flow reaches the rated flow of gas or liquid specified by the original valve manufacturer when piping mounted directly on the valve is sheared off before the first valve, pump, or fitting downstream from the excess flow valve.

    (iii) An excess-flow valve may be designed with a by-pass, not to exceed a 0.1016 cm (0.040 inches) diameter opening to allow equalization of pressure.

    (iv) Filling and discharge lines must be provided with manually operated shut-off valves located as close to the tank as practical. Unless this valve is manually operable at the valve, the line must also have a manual shut-off valve. The use of “Stop-Check” valves to satisfy with one valve the requirements of this section is forbidden. For portable tanks used for refrigerated liquefied gases, a “stop check” valve may be used on the vapor side of the pressure buildup circuit.

    (10) Each portable tank used for carbon dioxide or nitrous oxide must be lagged with a suitable insulation material of such thickness that the overall thermal conductance is not more than 0.08 Btu per square foot per degree Fahrenheit differential in temperature per hour. The conductance must be determined at 60° Fahrenheit. Insulation material used on portable tanks for nitrous oxide must be noncombustible.

    (11) Refrigerating or heating coils must be installed in portable tanks used for carbon dioxide and nitrous oxide. Such coils must be tested externally to at least the same pressure as the test pressure of the portable tank. The coils must also be tested internally to at least twice the working pressure of the heating or refrigerating system to be used, but in no case less than the test pressure of the portable tank. Such coils must be securely anchored. In the event of leakage, the refrigerant or heating medium to be circulated through the coil or coils must have no adverse chemical reaction with the portable tank or its contents.

    (12) Excess flow valves are not required for portable tanks used for the transport of refrigerated liquefied gases.

    [Removed]
    Start Amendment Part

    31. Section 173.32a is removed.

    End Amendment Part
    [Removed]
    Start Amendment Part

    32. Section 173.32b is removed.

    End Amendment Part
    [Removed]
    Start Amendment Part

    33. § 173.32c is removed.

    End Amendment Part
    [Amended]
    Start Amendment Part

    34. In § 173.34, in the paragraph (e)(13) table, in the second column, the following changes are made:

    End Amendment Part

    a. In the second entry, the wording “Butadiene, inhibited” is revised to read “Butadiene, stabilized'.

    b. In the ninth entry, the wording “Ethyleneimine, inhibited” is revised to read “Ethyleneimine, stabilized'.

    35. In § 173.61, paragraph (e)(3) is revised and a new paragraph (e)(8) is added to read as follows:

    Mixed packaging requirements.
    * * * * *

    (e) * * *

    (3) Explosives of compatibility group S may be packaged together with explosives of any other compatibility group except A or L, and the combined package may be treated as belonging to any of the packaged compatibility groups except S.

    * * * * *

    (8) Explosive articles of compatibility group G, except for fireworks and articles requiring special packaging, may be packaged together with explosive articles of compatibility groups C, D or E and the combined package shall be treated as belonging to compatibility group E.

    Start Amendment Part

    36. In § 173.62, in paragraph (b), in the Explosives Table, two entries are added in appropriate alphanumerical order and in paragraph (c), in the Explosives Packing Instructions Table, in the fourth column, for the packing instruction entry 144, under the Boxes entry “plastics, expanded (4H1)” add an entry for Drums to read as follows:

    End Amendment Part
    Specific packaging requirements for explosives.
    * * * * *

    (b) * * *

    Explosives Table

    ID#PI
    *    *    *    *    *
    UN0502130
    UN0504112(c)
    *    *    *    *    *

    (c) * * *

    Table of Packing Methods

    Packing instructionInner packagingsIntermediate packagingsOuter packagings
    *         *         *         *         *         *         *
    144 * * ** * ** * ** * *
    Drums.
    Steel, removable head (1A2).
    Aluminum, removable head (1B2).
    Plastics, removable head (1H2).
    Plywood (1D).
    *         *         *         *         *         *         *
    Start Printed Page 33430 Start Amendment Part

    37. In addition, in § 173.62, in paragraph (c), in the Explosives Packing Instructions Table, in the fourth column, the following changes are made in appropriate packaging specification number order:

    End Amendment Part

    a. For packing instruction entries, 112(a), 112(b), 112(c), 113, 115, 116, 130, 131, 134, 135, 136, 138, 140, 141 and 142, under the word “Drums”, the wording “plywood (1D)” is added in the alpha-numeric order of the parenthetical.

    b. For the packing instruction entries, 112(c), 113, 115, 134, 138 and 140, under the word “Drums”, the wording “plastics, removable head (1H2)” is added in the alpha-numeric order of the parenthetical.

    c. For the packing instruction entries, 134 and 138, under the word “Drums”, the wording “fiberboard (1G)” is added in the alpha-numeric order of the parenthetical.

    d. For the packing instruction entries, 112(c) and 113, under the word “Boxes”, the wording “aluminum (4B)” is added in the alpha-numeric order of the parenthetical.

    e. For the packing instruction entry, 144, under the word “Boxes”, the wording “plastics, solid (4H2)” is added in the alpha-numeric order of the parenthetical.

    Start Amendment Part

    38. In § 173.150, paragraph (d)(2) is revised to read as follows:

    End Amendment Part
    Exceptions for Class 3 (flammable) and combustible liquids.
    * * * * *

    (d) * * *

    (2) Is in an inner packaging of five liters (1.3 gallons) or less for transportation on passenger-carrying aircraft and conforms to § 175.10(a)(17) of this subchapter as checked or carry-on baggage; or

    * * * * *
    Start Amendment Part

    39. In § 173.162, paragraphs (a) introductory text and (a)(1) are revised to read as follows:

    End Amendment Part
    Gallium.

    (a) Except when packaged in cylinders or steel flasks, gallium must be packaged in packagings which meet the requirements of part 178 of this subchapter at the Packing Group I performance level for transportation by aircraft, and at the Packing Group III performance level for transport by highway, rail or vessel, as follows:

    (1) In combination packagings intended to contain liquids consisting of glass, earthenware or rigid plastic inner packagings with a maximum net mass of 15 kg (33 pounds) each. The inner packagings must be packed in wood boxes (4C1, 4C2, 4D, 4F), fiberboard boxes (4G), plastic boxes (4H1, 4H2), fiber drums (1G) or removable head steel and plastic drums or jerricans (1A2, 1H2, 3A2 or 3H2) with sufficient cushioning materials to prevent breakage. Either the inner packagings or the outer packagings must have an inner liner that is leakproof or bags of strong leakproof and puncture-resistant material impervious to the contents and completely surrounding the contents to prevent it from escaping from the package, irrespective of its position.

    * * * * *
    Start Amendment Part

    40. Section 173.185 is revised to read as follows:

    End Amendment Part
    Lithium batteries and cells.

    (a) Except as otherwise provided in this subpart, a lithium cell or battery is authorized for transportation only if it conforms to the provisions of this section. For the purposes of this subchapter, “lithium content” means the mass of lithium in the anode of a lithium metal or lithium alloy cell, except in the case of a lithium ion cell or battery where the “equivalent lithium content” in grams is calculated to be 0.3 times the rated capacity in ampere-hours.

    (b) Exceptions. Cells and batteries are not subject to the requirements of this subchapter if they meet the following requirements:

    (1) Each cell with a liquid cathode may contain not more than 0.5 g of lithium content. Each cell with a solid cathode may contain not more than 1.0 g of lithium content. Each lithium ion cell may contain not more than 1.5 g of equivalent lithium content;

    (2) Each battery with a liquid cathode may contain an aggregate quantity of not more than 1.0 g of lithium content. Each battery with a solid cathode may contain an aggregate quantity of not more than 2.0 g of lithium content. Each lithium-ion battery may contain an aggregate quantity of not more than 8.0 grams of equivalent lithium content;

    (3) Each cell or battery containing a liquid cathode must be hermetically sealed;

    (4) Cells and batteries must be packed in such a way so as to prevent short circuits and must be packed in strong packagings, except when installed in equipment; and

    (5) If when fully charged, the aggregate lithium content of the anodes in a liquid cathode battery is more than 0.5 g, or the aggregate lithium content of the anodes in a solid cathode battery is more than 1.0 g, then the battery may not contain a liquid or gas that is a hazardous material according to this subchapter unless the liquid or gas, if free, would be completely absorbed or neutralized by other materials in the battery.

    (c) Additional exceptions. Cells and batteries also are not subject to this subchapter if they meet the following requirements:

    (1) The lithium content of the anode of each cell, when fully charged, is not more than 5 g;

    (2) The aggregate lithium content of the anodes of each battery, when fully charged, is not more than 25 g;

    (3) Each cell or battery is of the type proven to be non-dangerous by testing in accordance with tests in the UN Manual of Tests and Criteria (see § 171.7 of this subchapter). Such testing must be carried out on each type of cell or battery prior to the initial transport of that type; and

    (4) Cells and batteries are designed or packed in such a way as to prevent short circuits under conditions normally encountered in transportation.

    (d) Cells and batteries and equipment containing cells and batteries which were first transported prior to January 1, 1995, and were assigned to Class 9 on the basis of the requirements of this subchapter in effect on October 1, 1993, may continue to be transported in accordance with the applicable requirements in effect on October 1, 1993.

    (e) Cells and batteries may be transported as items of Class 9 if they meet the requirements in paragraphs (e)(1) through (e)(7) of this section:

    (1) Each cell and battery must be equipped with an effective means of preventing external short circuits.

    (2) Each cell and battery must incorporate a safety venting device or be designed in a manner that will preclude a violent rupture under conditions normally incidental to transportation.

    (3) Batteries containing cells or series of cells connected in parallel must be equipped with diodes to prevent reverse current flow.

    (4) Cells and batteries must be packed in inner packagings in such a manner as to effectively prevent short circuits and to prevent movement which could lead to short circuits.

    (5) Cells and batteries must be packaged in packagings conforming to the requirements of part 178 of this subchapter at the Packing Group II performance level: Inner packagings must be packed within metal boxes (4A or 4B), wooden boxes (4C1, 4C2, 4D or 4F), fiberboard boxes (4G), solid plastic boxes (4H2), fiber drums (1G), metal drums (1A2 or 1B2), plywood drums (1D), plastic jerricans (3H2), or metal jerricans (3A2 or 3B2).Start Printed Page 33431

    (6) Each cell or battery must be of the type proven to meet the lithium battery requirements in the UN Manual of Tests and Criteria (see § 171.7 of this subchapter).

    (7) Except as provided in paragraph (h) of this section, cells or batteries may not be offered for transportation or transported if any cell has been discharged to the extent that the open circuit voltage is less than two volts or is less than 2/3 of the voltage of the fully charged cell, whichever is less.

    (f) Equipment containing or packed with cells and batteries meeting the requirements of paragraph (b) or (c) of this section is excepted from all other requirements of this subchapter.

    (g) Equipment containing or packed with cells and batteries may be transported as items of Class 9 if the batteries and cells meet all requirements of paragraph (e) of this section and are packaged as follows:

    (1) Equipment containing cells and batteries must be packed in a strong outer packaging that is waterproof or has a waterproof liner, unless the equipment is made waterproof by nature of its construction. The equipment must be secured within the outer packaging and be packed as to effectively prevent movement, short circuits, and accidental operation during transport; and

    (2) Cells and batteries packed with equipment must be packed in inner packagings conforming to (e)(5) of this section in such a manner as to effectively prevent movement and short circuits.

    (h) Cells and batteries, for disposal, may be offered for transportation or transported to a permitted storage facility and disposal site by motor vehicle when they meet the following requirements:

    (1) Be equipped with an effective means of preventing external short circuits; and

    (2) Be packed in a strong outer packaging conforming to the requirements of §§ 173.24 and 173.24a. The packaging need not conform to performance requirements of part 178 of this subchapter.

    (i) Cells and batteries and equipment containing or packed with cells and batteries which do not comply with the provisions of this section may be transported only if they are approved by the Associate Administrator.

    (j) For testing purposes, when not contained in equipment, cells and batteries may be offered for transportation or transported by highway as items of Class 9. Packaging must conform with paragraph (e)(5) of this section.

    Start Amendment Part

    41. In § 173.224, paragraph (b)(4) is revised; in the table following paragraph (b)(7), the following entry is added in appropriate alphabetical order; and paragraph (d) is removed to read as follows:

    End Amendment Part
    Packaging and control and emergency temperatures for self-reactive materials.
    * * * * *

    (b) * * *

    (4) Packing method. Column 4 specifies the highest packing method which is authorized for the self-reactive material. A packing method corresponding to a smaller package size may be used, but a packing method corresponding to a larger package size may not be used. The Table of Packing Methods in § 173.225(d) defines the packing methods. Bulk packagings are authorized as specified in § 173.225(d) for Type F self-reactive substances. Additional bulk packagings are authorized if approved by the Associate Administrator.

    * * * * *

    (7) * * *

    Self-Reactive Materials Table

    Self-reactive substanceIndentification no.Concentration (%)Packing methodControl temperature—(°C)(Emergency temperatureNotes
    (1)(2)(3)(4)(5)(6)(7)
    *         *         *         *         *         *         *
    2,2'-Azodi(isobutyronitrile) as a water based paste3224≤50%OP6
    *         *         *         *         *         *         *
    Start Amendment Part

    42. In § 173.225, in paragraph (b), in the Organic Peroxide Table, the following entries are removed and added in the appropriate alphabetical order; in Column (8), Notes “7” and “10” are removed each place they appear; and in the “NOTES” immediately following the Table, Notes “7” and “10” are removed and reserved and Note “26” is added in the appropriate numerical order; and paragraphs (e) introductory text, (e)(3) and (e)(5) are revised to read as follows:

    End Amendment Part
    Packaging requirements and other provisions for organic peroxides.
    * * * * *

    (b) * * *

    Organic Peroxide Table

    Technical nameID No.Concentration (mass %)Diluent (mass %)Water (mass %)Packing methodTemperature (°C)Notes
    ABIControlEmergency
    (1)(2)(3)(4a)(4b)(4c)(5)(6)(7a)(7b)(8)
    *         *         *         *         *         *         *
    [REMOVE:]
    tert-Amyl peroxybenzoateUN3105≤96≥4OP7
    *         *         *         *         *         *         *
    tert-Butyl peroxy-2-ethylhexanoateUN3119≤32≥68Bulk+10+1514
    *         *         *         *         *         *         *
    tert-Butyl peroxyneodecanoate [as a stable dispersion in water]UN3117≤42OP80+10
    Start Printed Page 33432
    *         *         *         *         *         *         *
    tert-Butyl peroxyneoheptanoateUN3115≤77≥23OP7+10+15
    *         *         *         *         *         *         *
    tert-Butyl peroxypivalateUN3119≤27≥73Bulk−5+514
    *         *         *         *         *         *         *
    Cumyl peroxyneoheptanoateUN3115≤77≥23OP70+10
    *         *         *         *         *         *         *
    Cyclohexanone peroxide(s)UN3105≤72≥28OP75
    *         *         *         *         *         *         *
    1,1-Di-(tert-butylperoxy)-3,5,5-trimethylcyclohexaneUN3101>90-100OP5
    1,1-Di-(tert-butylperoxy)-3,5,5-trimethylcyclohexaneUN3103>57-90≥10OP5
    1,1-Di-(tert-butylperoxy)-3,5,5-trimethylcyclohexaneUN3106≤57≥43OP7
    1,1-Di-(tert-butylperoxy)-3,5,5-trimethylcyclohexaneUN3107≤57≥43OP8
    1,1-Di-(tert-butylperoxy)-3,5,5-trimethylcyclohexaneUN3107≤32≥26≥42OP8
    *         *         *         *         *         *         *
    Di-(2-ethylhexyl)peroxydicarbonateUN3115≤77OP7−15−5
    *         *         *         *         *         *         *
    Diisopropyl peroxydicarbonateUN3115≤52≥48OP7−100
    *         *         *         *         *         *         *
    2,5-Dimethyl-2,5-di-(2-ethylhexanoylperoxy)hexaneUN3115≤100OP7+20+25
    *         *         *         *         *         *         *
    Dimyristyl peroxydicarbonate [as a stable dispersion in water]UN3119≤42IBC+15+25
    *         *         *         *         *         *         *
    Di-n-propyl peroxydicarbonateUN3113≤100OP4−25−15
    *         *         *         *         *         *         *
    Di-(3,5,5-trimethylhexanoyl)peroxideUN3119≤38≥62Bulk−10014
    *         *         *         *         *         *         *
    Isopropyl sec-butyl peroxydicarbonate [and]Di-sec-butyl peroxydi-carbonate [and]Di-isopropyl peroxydicarbonateUN3115≤32 +≤15-18 +≤12-15≥38OP7−20−10
    *         *         *         *         *         *         *
    2,4,4-Trimethylpentyl-2-peroxyneodecanoateUN3115≤72≥28OP7−5+5
    2,4,4-Trimethylpentyl-2-phenoxynedecanoate [as a stable dispersion in water].UN3119≤52OP8−5+5
    2,4,4-Trimethylpentyl-2-peroxy phenoxyacetateUN3115≤37≥63OP7−100
    *         *         *         *         *         *         *
    [ADD:]
    tert-Amyl peroxybenzoateUN3103≤100OP5
    *         *         *         *         *         *         *
    tert-Butyl peroxy-2-ethylhexanoateUN3119≤32≥68Bulk+15+2014
    *         *         *         *         *         *         *
    tert-Butyl peroxyneodecanoate [as a stable dispersion in water]UN3117≤52OP80+10
    *         *         *         *         *         *         *
    tert-Butyl peroxyneodecanoate [as a stable dispersion in water]UN3119≤42IBC−5+5
    *         *         *         *         *         *         *
    tert-Butyl peroxyneodecanoateUN3119≤32≥68IBC0+10
    *         *         *         *         *         *         *
    tert-Butyl peroxyneoheptanoateUN3115≤77≥23OP70+10
    *         *         *         *         *         *         *
    tert-Butyl peroxypivalateUN3119≤27≥73Bulk+5+1014
    *         *         *         *         *         *         *
    Cumyl peroxyneodecanoate [as a stable dispersion in water]UN3119≤52IBC−15−5
    *         *         *         *         *         *         *
    Cumyl peroxyneoheptanoateUN3115≤77≥23OP7−100
    Start Printed Page 33433
    *         *         *         *         *         *         *
    Cyclohexanone peroxide(s)UN3105≤72≥28OP75
    *         *         *         *         *         *         *
    1,1-Di-(tert-butylperoxy)-3,3,5-trimethylcyclohexaneUN3101>90-100OP5
    *         *         *         *         *         *         *
    1,1-Di-(tert-butylperoxy)-3,3,5-trimethylcyclohexaneUN3103>57-90≥10OP5
    *         *         *         *         *         *         *
    1,1-Di-(tert-butylperoxy)-3,3,5-trimethylcyclohexaneUN3105≤77≥23OP7
    *         *         *         *         *         *         *
    1,1-Di-(tert-butylperoxy)-3,3,5-trimethylcyclohexaneUN3106≤57≥43OP7
    *         *         *         *         *         *         *
    1,1-Di-(tert-butylperoxy)-3,3,5-trimethylcyclohexaneUN3107≤57≥43OP8
    *         *         *         *         *         *         *
    1,1-Di-(tert-butylperoxy)-3,3,5-trimethylcyclohexaneUN3107≤32≥26≥42OP8
    *         *         *         *         *         *         *
    2,2-Di-(4,4-di-(tert-butylperoxy cyclohexyl) propaneUN3107≤22≥78OP8
    *         *         *         *         *         *         *
    Di-(2-ethylhexyl) peroydicarbonate [as a stable dispersion in water]UN3119≤52IBC−20−10
    *         *         *         *         *         *         *
    Di-(2-ethoxyethyl) peroxydicarbonateUN3115≤52≥48OP7−100
    *         *         *         *         *         *         *
    Di-(2-ethylhexyl) peroxydicarbonateUN3115≤77≥23OP7−15−5
    *         *         *         *         *         *         *
    Di-(2-ethylhexyl) peroxydicarbonate [as a stable dispersion in water]UN3117≤62OP8−15−5
    *         *         *         *         *         *         *
    Diisopropyl peroxydicarbonateUN3115≤52≥48OP7−20−10
    *         *         *         *         *         *         *
    Di-(3-methoxybutyl) peroxydicarbonateUN3115≤52≥48OP7−5+5
    *         *         *         *         *         *         *
    Di-(3-methylbenzoyl) peroxide + Benzoyl (3-methylbenzoyl) peroxide +Dibenzoyl peroxideUN3115≤20 +≤18 +≤ 4≥58OP7+35+40
    *         *         *         *         *         *         *
    2,5 Dimethyl 2,5 di-2-ethylhexanoylperoxy hexaneUN3113≤100OP5+20+25
    *         *         *         *         *         *         *
    2,5-Dimethyl-2,5-di-(tert-butylperoxy)hexaneUN3108≤77≥23OP8
    *         *         *         *         *         *         *
    2,5-Dimethyl-2,5-di-(tert-butylperoxy)hexyne-3UN3101>86-100OP5
    *         *         *         *         *         *         *
    Dimyristyl peroxydicarbonate [as a stable dispersion in water]UN3119≤42IBC+15+20
    *         *         *         *         *         *         *
    Di-n-propyl peroxydicarbonateUN3113≤100OP3−25−15
    *         *         *         *         *         *         *
    Di-n-propyl peroxydicarbonateUN3113≤77≥23OP5−20−10
    *         *         *         *         *         *         *
    tert-Hexyl peroxyneodecanoateUN3115≤71≥29OP70+10
    *         *         *         *         *         *         *
    tert-Hexyl peroxypivalateUN3115≤72≥28OP7+10+15
    *         *         *         *         *         *         *
    Methyl ethyl ketone peroxide(s)UN3105≤37≥55≥8OP75
    *         *         *         *         *         *         *
    1,1,3,3-Tetramethylbutyl peroxyneodecanoateUN3115≤72≥28OP7-5+5
    Start Printed Page 33434
    1,1,3,3-Tetramethylbutyl peroxyneodecanoate [as a stable dispersion in water].UN3119≤52IBC−5+5
    1,1,3,3-Tetramethylbutyl peroxy phenoxyacetateUN3115≤37≥63OP7−100
    *         *         *         *         *         *         *
    3,6,9-Triethyl-3,6,9-trimethyl-1,4,7-triperoxonaneUN3105≤42≥58OP726
    *         *         *         *         *         *         *
    Notes:
    *    *    *    *    *
      26. Available oxygen must be ≤ 7.6%.
    *    *    *    *    *

    (e) Bulk packagings for organic peroxides. The following bulk packagings are authorized:

    * * * * *

    (3) Portable tanks. The following requirements apply to portable tanks intended for the transport of Type F organic peroxides or Type F self-reactive substances. DOT 51, 57, IM 101 portable tanks, and UN portable tanks that conform to the requirements of T23 (see § 172.102(c)(7) of this subchapter), when T23 is specified in Column (7) of the § 171.101 Table of this subchapter for the Type F organic peroxide or Type F self-reactive substance. Type F organic peroxide or self-reactive substance formulations other than those indicated in T23 may be transported in portable tanks if approved by the Associate Administrator. The following conditions also apply:

    (i) The portable tank must be designed for a test pressure of at least 0.4 MPa (4 bar).

    (ii) Portable tanks must be fitted with temperature-sensing devices.

    (iii) Portable tanks must be fitted with pressure relief devices and emergency-relief devices. Vacuum-relief devices may also be used. Pressure relief devices must operate at pressures determined according to both the properties of the hazardous material and the construction characteristics of the portable tank. Fusible elements are not allowed in the shell.

    (iv) The pressure relief devices must consist of reclosing devices fitted to prevent significant build-up within the portable tank of the decomposition products and vapors released at a temperature of 50 °C (122 °F). The capacity and start-to-discharge pressure of the relief devices must be in accordance with the applicable requirements of this subchapter specified for the portable tank. The start-to-discharge pressure must in no case be such that liquid would escape from the pressure relief devices if the portable tank were overturned.

    (v)(A) The emergency-relief devices may be of the reclosing or frangible types, or a combination of the two, designed to vent all the decomposition products and vapors evolved during a period of not less than one hour of complete fire engulfment as calculated by the following formula:

    Where:

    q = heat absorption (W)

    A = wetted area (m2)

    F = insulation factor (-)

    (B) Insulation factor (F) in the formula in paragraph (e)(3)(v)(A) of this section equals 1 for non-insulated vessels and for insulated vessels F is calculated using the following formula:

    Where:

    U = K/L = heat transfer coefficient of the insulation (W·m2·K1); where K = heat conductivity of insulation layer (W·m1·K1), and L = thickness of insulation layer (m).

    TPO = temperature of material at relieving conditions (K).

    (vi) The start-to-discharge pressure of emergency-relief devices must be higher than that specified for the pressure relief devices in paragraph (e)(3)(iv) of this section. The emergency-relief devices must be sized and designed in such a way that the maximum pressure in the shell never exceeds the test pressure of the portable tank.

    Note to Paragraph (e)(3)(vi):

    An example of a method to determine the size of emergency-relief devices is given in Appendix 5 of the UN Manual of Tests and Criteria (incorporated by reference, see § 171.7 of this subchapter).

    (vii) For insulated portable tanks, the capacity and setting of emergency-relief devices must be determined assuming a loss of insulation from 1 percent of the surface area.

    (viii) Vacuum-relief devices and reclosing devices on portable tanks used for flammable hazardous materials must be provided with flame arresters. Any reduction of the relief capacity caused by the flame arrester must be taken into account and the appropriate relief capacity must be provided.

    (ix) Service equipment such as devices and external piping must be designed and constructed so that no hazardous material remains in them after filling the portable tank.

    (x) Portable tanks may be either insulated or protected by a sun-shield. If the SADT of the hazardous material in the portable tank is 55 °C (131°F) or less, the portable tank must be completely insulated. The outer surface must be finished in white or bright metal.

    (xi) The degree of filling must not exceed 90% at 15 °C (59 °F).

    (xii) DOT 57 metal portable tanks are authorized only for tert-butyl cumyl peroxide, di-(2-tert-butylperoxyisopropyl-benzene(s), dicumyl peroxide and mixtures of two or more of these peroxides. DOT 57 portable tanks must conform to the venting requirements of paragraph (e)(5) of this section. These portable tanks are not subject to the requirements of Start Printed Page 33435paragraphs (e)(3)(ii) and (e)(3)(iv) of this section.

    * * * * *

    (5) IBCs. IBCs are authorized subject to the conditions and limitations of this section provided the IBC type is authorized according to IB52 (see § 172.102(c)(4) of this subchapter), as applicable, and the IBC conforms to the requirements in subpart O of part 178 of this subchapter at the Packing Group II performance level. The following additional requirements also apply:

    (i) IBCs shall be provided with a device to allow venting during transportation. The inlet to the pressure relief device shall be sited in the vapor space of the IBC under maximum filling conditions during transportation.

    (ii) To prevent explosive rupture of metal IBCs or composite IBCs with complete metal casing, the emergency-relief devices shall be designed to vent all the decomposition products and vapors evolved during self-accelerating decomposition or during a period of not less than one hour of complete fire-engulfment as calculated by the formula in paragraph (e)(3)(v) of this section. The control and emergency temperatures specified in IB52 are based on a non-insulated IBC.

    Start Amendment Part

    43. In § 173.240, paragraphs (c) and (d) are revised to read as follows:

    End Amendment Part
    Bulk packaging for certain low hazard solid materials.
    * * * * *

    (c) Portable tanks and closed bulk bins. DOT 51, 56, 57 and 60 portable tanks; IMO type 1, 2 and 5, and IM 101 and IM 102 portable tanks; UN portable tanks; marine portable tanks conforming to 46 CFR part 64; and sift-proof non-DOT Specification portable tanks and closed bulk bins are authorized.

    (d) IBCs. IBCs are authorized subject to the conditions and limitations of this section provided the IBC type is authorized according to the IBC packaging code specified for the specific hazardous material in Column (7) of the § 172.101 Table of this subchapter and the IBC conforms to the requirements in subpart O of part 178 of this subchapter at the Packing Group performance level as specified in Column (5) of the § 172.101 Table of this subchapter for the material being transported.

    (1) IBCs may not be used for the following hazardous materials:

    (i) Packing Group I liquids; and

    (ii) Packing Group I solids that may become liquid during transportation.

    (2) The following IBCs may not be used for Packing Group II and III solids that may become liquid during transportation:

    (i) Wooden: 11C, 11D and 11F;

    (ii) Fiberboard: 11G;

    (iii) Flexible: 13H1, 13H2, 13H3, 13H4, 13H5, 13L1, 13L2, 13L3, 13L4, 13M1 and 13M2; and

    (iv) Composite: 11HZ2 and 21HZ2.

    Start Amendment Part

    44. In § 173.241, paragraphs (c) and (d) are revised to read as follows:

    End Amendment Part
    Bulk packagings for certain low hazard liquid and solid materials.
    * * * * *

    (c) Portable tanks. DOT Specification 51, 56, 57 and 60 portable tanks; IMO type 1, 2 and 5, and IM 101 and IM 102 portable tanks; UN portable tanks; marine portable tanks conforming to 46 CFR part 64; and non-DOT Specification portable tanks suitable for transport of liquids are authorized.

    (d) IBCs. IBCs are authorized subject to the conditions and limitations of this section provided the IBC type is authorized according to the IBC packaging code specified for the specific hazardous material in Column (7) of the § 172.101 Table of this subchapter and the IBC conforms to the requirements in subpart O of part 178 of this subchapter at the Packing Group performance level as specified in Column (5) of the § 172.101 Table for the material being transported.

    (1) IBCs may not be used for the following hazardous materials:

    (i) Packing Group I liquids; and

    (ii) Packing Group I solids that may become liquid during transportation.

    (2) The following IBCs may not be used for Packing Group II and III solids that may become liquid during transportation:

    (i) Wooden: 11C, 11D and 11F;

    (ii) Fiberboard: 11G;

    (iii) Flexible: 13H1, 13H2, 13H3, 13H4, 13H5, 13L1, 13L2, 13L3, 13L4, 13M1 and 13M2; and

    (iv) Composite: 11HZ2 and 21HZ2.

    Start Amendment Part

    45. In § 173.242, paragraphs (c) introductory text and (d) are revised to read as follows:

    End Amendment Part
    Bulk packagings for certain medium hazard liquids and solids, including solids with dual hazards.
    * * * * *

    (c) Portable tanks. DOT Specification 51, 56, 57 and 60 portable tanks; Specification IM and UN portable tanks when a T Code is specified in Column (7) of the § 172.101 Hazardous Materials Table for a specific hazardous material; and marine portable tanks conforming to 46 CFR part 64 are authorized. DOT Specification 57 portable tanks used for the transport by vessel of Class 3, Packaging Group II materials must conform to the following:

    * * * * *

    (d) IBCs. IBCs are authorized subject to the conditions and limitations of this section provided the IBC type is authorized according to the IBC packaging code specified for the specific hazardous material in Column (7) of the § 172.101 Table of this subchapter and the IBC conforms to the requirements in subpart O of part 178 of this subchapter at the Packing Group performance level as specified in Column (5) of the § 172.101 Table of this subchapter for the material being transported.

    (1) IBCs may not be used for the following hazardous materials:

    (i) Packing Group I liquids; and

    (ii) Packing Group I solids that may become liquid during transportation.

    (2) The following IBCs may not be used for Packing Group II and III solids that may become liquid during transportation:

    (i) Wooden: 11C, 11D and 11F;

    (ii) Fiberboard: 11G;

    (iii) Flexible: 13H1, 13H2, 13H3, 13H4, 13H5, 13L1, 13L2, 13L3, 13L4, 13M1 and 13M2; and

    (iv) Composite: 11HZ2 and 21HZ2.

    Start Amendment Part

    46. In § 173.243, paragraphs (c) and (d) are revised to read as follows:

    End Amendment Part
    Bulk packaging for certain high hazard liquids and dual hazard materials which pose a moderate hazard.
    * * * * *

    (c) Portable tanks. DOT Specification 51 and 60 portable tanks; UN portable tanks when a T code is specified in Column (7) of the § 172.101 Table of this subchapter for a specific hazardous material; and marine portable tanks conforming to 46 CFR part 64 with design pressure of at least 172.4 kPa (25 psig) are authorized.

    (d) IBCs. IBCs are authorized subject to the conditions and limitations of this section provided the IBC type is authorized according to the IBC packaging code specified for the specific hazardous material in Column (7) of the § 172.101 Table of this subchapter and the IBC conforms to the requirements in subpart O of part 178 of this subchapter at the Packing Group performance level as specified in Column (5) of the § 172.101 Table of this subchapter for the material being transported.

    (1) IBCs may not be used for the following hazardous materials:

    (i) Packing Group I liquids; and

    (ii) Packing Group I solids that may become liquid during transportation.

    (2) The following IBCs may not be used for Packing Group II and III solids that may become liquid during transportation:

    (i) Wooden: 11C, 11D and 11F;

    (ii) Fiberboard: 11G;

    (iii) Flexible: 13H1, 13H2, 13H3, 13H4, 13H5, 13L1, 13L2, 13L3, 13L4, 13M1 and 13M2; andStart Printed Page 33436

    (iv) Composite: 11HZ2 and 21HZ2.

    * * * * *
    Start Amendment Part

    47. In § 173.247, paragraph (c) is revised to read as follows:

    End Amendment Part
    Bulk packaging for certain elevated temperature materials (Class 9) and certain flammable elevated temperature materials (Class 3).
    * * * * *

    (c) Portable tanks. DOT Specification 51, 56, 57 and 60 portable tanks; IM 101 and IM 102 portable tanks; UN portable tanks; marine portable tanks conforming to 46 CFR part 64; metal IBCs and non-specification portable tanks equivalent in structural design and accident damage resistance to specification packagings are authorized.

    * * * * *
    [Amended]
    Start Amendment Part

    48. In § 173.301, in paragraph (d)(2), in the first sentence, the wording “tetrafluoroethylene, inhibited” is revised to read “tetrafluoroethylene, stabilized”.

    End Amendment Part
    [Amended]
    Start Amendment Part

    49. In § 173.304, the following changes are made:

    End Amendment Part

    a. In the paragraph (a)(2) table, in the first column, in the second to the last entry, the wording “Vinyl fluoride, inhibited” is revised to read “Vinyl fluoride, stabilized”.

    b. In paragraph (b), in the first sentence, the wording “vinyl fluoride, inhibited” is revised to read “vinyl fluoride, stabilized”.

    Start Amendment Part

    50. In § 173.306, paragraph (a)(4)(iii) is revised to read as follows:

    End Amendment Part
    Limited quantities of compressed gases.
    * * * * *

    (4) ** *

    (iii) Non-pressurized gases, flammable must be packed in hermetically-sealed glass or metal inner packagings of not more than 5 L (1.3 gallons) and overpacked in a strong outer packaging.

    * * * * *
    [Amended]
    Start Amendment Part

    51. In § 173.314, the following changes are made:

    End Amendment Part

    a. In the paragraph (c) table, in the first column, the last entry, “Vinyl fluoride, inhibited” is revised to read “Vinyl fluoride, stabilized”.

    b. In paragraph (g) introductory text, the wording “vinyl fluoride, inhibited” is revised to read “vinyl fluoride, stabilized”.

    Start Amendment Part

    52. In § 173.315:

    End Amendment Part

    a. The text of paragraph (a) preceding the table is revised;

    b. In the paragraph (a) table, in the first column, the entry “Butadiene, inhibited” is revised to read “'Butadiene, stabilized” and the second to the last entry “Vinyl fluoride, inhibited” is revised to read “Vinyl fluoride, stabilized”;

    c. In paragraph (b) introductory text, the wording “butadiene, inhibited” is revised to read “butadiene, stabilized”;

    d. In the paragraph (h) table, in the first column, the sixth entry, “Butadiene, inhibited” is revised to read “Butadiene, stabilized”;

    e. Paragraphs (i)(1)(iii), (i)(3), (i)(4) and (i)(8) are revised; and

    f. Paragraph (i)(7) is removed and reserved.

    The revisions read as follows:

    Compressed gases in cargo tanks and portable tanks.

    (a) Liquefied compressed gases that are transported in UN portable tanks must be loaded and offered for transportation in accordance with portable tank provision T50 in § 172.102 of this subchapter. A liquefied compressed gas offered for transportation in a cargo tank motor vehicle or a portable tank must be prepared in accordance with this section, § 173.32, § 173.33 and subpart E or subpart G of part 180 of this subchapter, as applicable. For cryogenic liquids, see § 173.318. For marking requirements, see §§ 172.326 and 172.328 of this subchapter. Except for UN portable tanks, a liquefied compressed gas must be loaded and offered for transportation in accordance with the following table:

    * * * * *

    (i) * * *

    (1) * * *

    (iii) For an insulated tank, the required relieving capacity of the relief devices must be the same as for an uninsulated tank, unless the insulation will remain in place and will be effective under fire conditions. In this case, except for UN portable tanks, each insulated tank must be covered by a sheet metal jacket of not less than 16 gauge thickness. For UN portable tanks where the relieving capacity of the valves has been reduced on the basis of the insulation system, the insulation system must remain effective at all temperatures less than 649°C (1200.2°F) and be jacketed with a material having a melting point of 700 °C (1292.0 °F) or greater.

    * * * * *

    (3) Each safety relief valve on a portable tank, other than a UN portable tank, must be set to start-to-discharge at pressure no higher than 110% of the tank design pressure and no lower than the design pressure specified in paragraph (a) of this section for the gas transported. For UN portable tanks used for liquefied compressed gases and constructed in accordance with the requirements of § 178.276 of this subchapter, the pressure relief device(s) must conform to § 178.276(e) of this subchapter.

    (4) Except for UN portable tanks, each safety relief valve must be plainly and permanently marked with the pressure in p.s.i.g. at which it is set to discharge, with the actual rate of discharge of the device in cubic feet per minute of the gas or of air at 60 °F (15.6 °C) and 14.7 p.s.i.a., and with the manufacturer's name or trade name and catalog number. The start-to-discharge valve marking must be visible after the valve is installed. The rated discharge capacity of the device must be determined at a pressure of 120% of the design pressure of the tank. For UN portable tanks, each pressure relief device must be clearly and permanently marked as specified in § 178.274(f)(1) of this subchapter.

    * * * * *

    (8) Each safety relief valve outlet must be provided with a protective device to prevent the entrance and accumulation of dirt and water. This device must not impede flow through the valve. Pressure relief devices must be designed to prevent the entry of foreign matter, the leakage of liquid and the development of any dangerous excess pressure.

    * * * * *
    Start Amendment Part

    53. In § 173.320, paragraph (c) is revised to read as follows:

    End Amendment Part
    Cryogenic liquids; exceptions.
    * * * * *

    (c) For transportation aboard aircraft, see the ICAO Technical Instructions, Packing Instruction P202 and the packaging specifications in part 6, Chapter 5. (See § 171.7 of this subchapter for ICAO Technical Instructions.)

    Start Part

    PART 175—CARRIAGE BY AIRCRAFT

    End Part Start Amendment Part

    54. The authority citation for part 175 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 49 U.S.C. 5101-5127; 49 CFR 1.53.

    End Authority Start Amendment Part

    55. In § 175.10, paragraphs (a)(10) and (a)(16) are revised, and paragraph (a)(17) is added to read as follows:

    End Amendment Part
    Exceptions.

    (a) * * *

    (10) Safety matches or a lighter intended for use by an individual when carried on one's person. However, lighters containing unabsorbed liquid Start Printed Page 33437fuel (other than liquefied gas), lighter fuel, and lighter refills are not permitted on one's person or in checked or carry-on baggage.

    * * * * *

    (16) Perfumes and colognes, purchased through duty-free sales, carried by passengers or crew in carry-on baggage.

    (17) Alcoholic beverages containing:

    (i) Not more than 24% alcohol by volume; or

    (ii) More than 24% and not more than 70% alcohol by volume when in retail packagings not exceeding 5 liters (1.3 gallons) carried by a crew member or passenger in checked or carry-on baggage, with a total net quantity per person of 5 liters (1.3 gallons) for such beverages.

    * * * * *
    Start Amendment Part

    56. In § 175.33, paragraph (a) introductory text is revised to read as follows:

    End Amendment Part
    Notification of pilot-in-command.

    (a) Except as provided in § 175.10, when a hazardous material subject to the provisions of this subchapter is carried in an aircraft, the operator of the aircraft must provide the pilot-in-command with accurate and legible written information as early as practicable before departure of the aircraft, which specifies at least the following:

    * * * * *
    Start Amendment Part

    57. § 175.78 is revised to read as follows:

    End Amendment Part
    Stowage compatibility of cargo.

    (a) For stowage on an aircraft, in a cargo facility, or in any other area at an airport designated for the stowage of hazardous materials, packages containing hazardous materials which might react dangerously with one another may not be placed next to each other or in a position that would allow a dangerous interaction in the event of leakage.

    (b) As a minimum, the segregation instructions prescribed in the following Segregation Table must be followed to maintain acceptable segregation between packages containing hazardous materials with different hazards. The Segregation Table instructions apply whether or not the class or division is the primary or subsidiary risk. The Segregation Table follows:

    Segregation Table

    Hazard labelClass or division
    1234.24.35.15.28
    1Note 1Note 2Note 2Note 2Note 2Note 2Note 2Note 2
    2Note 2
    3Note 2X
    4.2Note 2X
    4.3Note 2X
    51Note 2XX
    5.2Note 2
    8Note 2X

    (c) Instructions for using the Segregation Table are as follows:(1) The dots at the intersection of a row and column indicate that no restrictions apply.

    (2) The letter “X” at the intersection of a row and column indicates that packages containing these classes of hazardous materials may not be stowed next to or in contact with each other, or in a position which would allow interaction in the event of leakage of the contents.

    (3) Note 1. “Note 1” at the intersection of a row and column means the following:

    (i) For explosives in compatibility groups A through K and N —

    (A) Packages bearing the same compatibility group letter and the same division number may be stowed together.

    (B) Explosives of the same compatibility group, but different divisions may be stowed together provided the whole shipment is treated as belonging to the division having the smaller number. However, when explosives of Division 1.5 Compatibility Group D are stowed together with explosives of Division 1.2 Compatibility Group D, the whole shipment must be treated as Division 1.1, Compatibility Group D.

    (C) Packages bearing different compatibility group letters may not be stowed together whether or not they belong to the same division, except as provided in paragraphs (c)(3)(ii) and (iii) of this section.

    (ii) Explosives in Compatibility Group L may not be stowed with explosives in other compatibility groups. They may only be stowed with the same type of explosives in Compatibility Group L.

    (iii) Explosives of Division 1.4, Compatibility Group S, may be stowed with explosives of all compatibility groups except for Compatibility Groups A and L.

    (iv) Other than explosives of Division 1.4, Compatibility Group S (see paragraph (c)(3)(iii) of this section), and Compatibility Groups C, D and E that may be stowed together, explosives that do not belong in the same compatibility group may not be stowed together.

    (A) Any combination of substances in Compatibility Groups C and D must be assigned to the most appropriate compatibility group shown in the § 172.101 Table of this subchapter.

    (B) Explosives in Compatibility Group N may be stowed together with explosives in Compatibility Groups C, D or E when the combination is assigned Compatibility Group D.

    (4) Note 2. “Note 2” at the intersection of a row and column means that other than explosives of Division 1.4, Compatibility Group S, explosives may not be stowed together with that class.

    (5) Packages containing hazardous materials with multiple hazards in the Start Printed Page 33438class or divisions, which require segregation in accordance with the Segregation Table need not be segregated from other packages bearing the same UN number.

    (6) A package labeled “BLASTING AGENT” may not be stowed next to or in a position that will allow contact with a package of special fireworks or railway torpedoes.

    Start Amendment Part

    58. In § 175.85, paragraph (a) is revised to read as follows:

    End Amendment Part
    Cargo location.

    (a) Except as provided in § 175.10, no person may carry a hazardous material subject to the requirements of this subchapter in the cabin of a passenger-carrying aircraft or on the flight deck of any aircraft. Hazardous materials may be carried in a main deck cargo compartment of a passenger aircraft provided that the compartment is inaccessible to passengers and that it meets all certification requirements for a Class B aircraft cargo compartment in 14 CFR 25.857(b) or for a Class C aircraft cargo compartment in 14 CFR 25.857(c).

    * * * * *
    Start Part

    PART 176—CARRIAGE BY VESSEL

    End Part Start Amendment Part

    59. The authority citation for part 176 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 49 U.S.C. 5101-5127; 49 CFR 1.53.

    End Authority Start Amendment Part

    60. In § 176.2, the following definition is added in appropriate alphabetical order to read as follows:

    End Amendment Part
    Definitions.
    * * * * *

    INF cargo means packaged irradiated nuclear fuel, plutonium or high-level radioactive wastes as those terms are defined in the “International Code for the Safe Carriage of Packaged Irradiated Nuclear Fuel, Plutonium and High-Level Radioactive Wastes on Board Ships' (INF Code) (contained in IMDG Code, 2000 edition, see § 171.7 of this subchapter).

    * * * * *
    Start Amendment Part

    61. In § 176.63, a new paragraph (e) is added to read as follows:

    End Amendment Part
    Stowage locations.
    * * * * *

    (e) Closed cargo transport unit, for the purpose of stowage of Class 1 (explosive) materials on board a vessel, means a clean, substantial, weatherproof box structure which can be secured to the ship's structure and includes a closed freight container, a closed vehicle, a closed rail wagon or a portable magazine. When this stowage is specified, stowage in small compartments such as deckhouses and mast lockers or oversized weatherproof packages (overpacks) are acceptable alternatives. The floor of any closed cargo transport unit or compartment shall be constructed of wood, close boarded or arranged so that goods are stowed on sparred gratings, wooden pallets or dunnage. Provided that the necessary additional specifications are met, a closed cargo transport unit may be used for Class 1 (explosive) magazine stowage type “A,” “B” or “C,” but not as a portable magazine.

    Start Amendment Part

    62. In § 176.84, in paragraph (b) Table of provisions, the entries “4” and “5” are revised; paragraph (c)(1) is revised; paragraph (c)(2), the List of Notes is revised; and paragraph (c)(3) is removed to read as follows:

    End Amendment Part
    Other requirements for stowage and segregation for cargo vessels and passenger vessels.
    * * * * *

    (b) Table of provisions:

    CodeProvisions
    *    *    *    *    *
    4Stow “Separated from” liquid organic materials.
    5Stow “Separated from” powdered metals and their compounds.
    *    *    *    *    *

    (c) * * * (1) Explosive substances and explosive articles must be stowed in accordance with Column (10A) and Column (10B) of the 172.101 Table of this subchapter.

    (2) * * *

    NotesProvisions
    5EStow “away from” lead and its compounds.
    7EStowage category “04” for projectiles or cartridges for guns, cannons or mortars; Stowage category “08” for other types.
    8EWhen under deck, special stowage is required.
    14EOn deck, cargo transport unit must be steel.
    15EOn deck, cargo transport unit must be leakproof.
    17EOn deck stowage is recommended.
    19EStow “away from” Explosive, blasting, type C, UN0083 which contain chlorates or perchlorates.
    20EStowage category “03” for projectiles or cartridges for guns, cannons or mortars; Stowage category “07” for other types; magazines must be of steel construction that prevents leakage.
    21ECargo space ventilation must be carefully controlled to avoid excessive condensation.
    22EWhen containing chlorates or perchlorates, stow “away from” explosives containing ammonium nitrate or other ammonium salts.
    23ESegregate from other Class 1 (explosive) materials in the same manner as is required for flammable liquids.
    26EStowage category “13” and, for on deck stowage, non-metallic lining of closed cargo transport unit is required when not in effectively sealed, sift-proof packages; Stowage category “10” permitted when in effectively sealed, sift-proof packages.
    0127EFor closed cargo transport unit, a non-metallic lining is required.
    [Amended]
    Start Amendment Part

    63. In § 176.128, in paragraph (c), the word “UN 0600” is revised to read “UN 0060”.

    End Amendment Part
    [Amended]
    Start Amendment Part

    64. In § 176.136, in paragraph (e), the word “portable” is removed.

    End Amendment Part Start Amendment Part

    65. In § 176.142, paragraph (a) is revised to read as follows:

    End Amendment Part
    Hazardous materials of extreme flammability.

    (a) Except as allowed by paragraph (b) of this section, certain hazardous materials of extreme flammability may not be transported in a vessel carrying Class 1 (explosive) materials. This prohibition applies to the following liquid hazardous materials:

    Carbon disulfideUN1131Class 3
    DiethylzincUN1366Division 4.2
    DimethylzincUN1370Division 4.2
    Magnesium alkylsUN3053Division 4.2
    Methyl phosphonous dichloride, pyrophoric liquidNA2845Division 6.1
    Nickel carbonylUN1259Division 6.1
    Pyrophoric liquid, inorganic, n.o.s.UN3194Division 4.2
    Pyrophoric liquids, organic, n.o.s.UN2845Division 4.2
    Pyrophoric organometallic compound, water-reactive, n.o.s.UN3203Division 4.2
    Start Printed Page 33439
    * * * * *
    Start Amendment Part

    66. A new section § 176.720 is added to subpart M to read as follows:

    End Amendment Part
    Requirements for carriage of INF cargo in international transportation.

    A vessel carrying INF cargo (see § 176.2, under INF cargo definition) in international transportation must meet the requirements of the INF Code (contained in IMDG Code, 2000 edition, see § 171.7 of this subchapter) in addition to all other applicable requirements of this subchapter.

    Start Part

    PART 177—CARRIAGE BY PUBLIC HIGHWAY

    End Part Start Amendment Part

    67. The authority citation for part 177 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 49 U.S.C. 5101-5127; 49 CFR 1.53.

    End Authority Start Amendment Part

    68. In § 177.848, paragraph (g)(3)(vi) is revised to read as follows:

    End Amendment Part
    Segregation of hazardous materials.
    * * * * *

    (g) * * *

    (3) * * *

    (vi) “6” means explosive articles in compatibility group G, other than fireworks and those requiring special handling, may be loaded, transported and stored with other explosive articles of compatibility groups C, D and E, provided that explosive substances (such as those not contained in articles) are not carried in the same vehicle.

    * * * * *
    Start Part

    PART 178—SPECIFICATIONS FOR PACKAGINGS

    End Part Start Amendment Part

    69. The authority citation for part 178 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 49 U.S.C. 5101-5127; 49 CFR 1.53.

    End Authority Start Amendment Part

    70. A new section § 178.273 is added to subpart H to read as follows:

    End Amendment Part
    Approval of Specification IM portable tanks and UN portable tanks.

    (a) Application for approval. (1) An owner or manufacturer of a portable tank shall apply for approval to a designated approval agency authorized to approve the portable tank in accordance with the procedures in subpart E, part 107 of this subchapter.

    (2) Each application for approval must contain the following information:

    (i) Two complete copies of all engineering drawings, calculations, and test data necessary to ensure that the design meets the relevant specification.

    (ii) The manufacturer's serial number that will be assigned to each portable tank.

    (iii) A statement as to whether the design type has been examined by any approval agency previously and judged unacceptable. Affirmative statements must be documented with the name of the approval agency, reason for nonacceptance, and the nature of modifications made to the design type.

    (b) Action by approval agency. The approval agency must perform the following activities:

    (1) Review the application for approval to determine whether it is complete and conforms with the requirements of paragraph (a) of this section. If an application is incomplete, it will be returned to the applicant with an explanation as to why the application is incomplete.

    (2) Review all drawings and calculations to ensure that the design is in compliance with all requirements of the relevant specification. If the application is approved, one set of the approved drawings, calculations, and test data shall be returned to the applicant. The second (inspector's copy) set of approved drawings, calculations, and test data shall be retained by the approval agency. Maintain drawings and approval records for as long as the portable tank remains in service. The drawings and records must be provided to the Department of Transportation (DOT) upon request.

    (3) Witness all tests required for the approval of the portable tank specified in this section and part 180, subpart G of this subchapter.

    (4) Ensure, through appropriate inspection that each portable tank is fabricated in all respects in conformance with the approved drawings, calculations, and test data.

    (5) Determine and ensure that the portable tank is suitable for its intended use and that it conforms to the requirements of this subchapter.

    (6) For UN portable tanks intended for non-refrigerated and refrigerated liquefied gases and Division 6.1 liquids which meet the inhalation toxicity criteria (Zone A or B) as defined in § 173.132 of this subchapter, or that are designated as toxic by inhalation materials in the § 172.101 Table of this subchapter, the approval agency must ensure that:

    (i) The portable tank has been constructed in accordance with the ASME Code, Section VIII, Division 1 (see § 171.7 of this subchapter). ASME Code, Section VIII, Division 2 (see § 171.7 of this subchapter) or other design codes may be used if approved by the Associate Administrator (see § 178.274(b)(1));

    (ii) All applicable provisions of the design and construction have been met to the satisfaction of the designated approval agency in accordance with the rules established in the ASME Code and that the portable tank meets the requirements of the ASME Code and all the applicable requirements specified in this subchapter;

    (iii) The inspector has carried out all the inspections specified by the rules established in the ASME Code; and

    (iv) The portable tank is marked with a U stamp code symbol under the authority of the authorized independent inspector.

    (7) Upon successful completion of all requirements of this subpart, the approval agency must:

    (i) Apply its name, identifying mark or identifying number, and the date upon which the approval was issued, to the metal identification marking plate attached to the portable tank. Any approvals for UN portable tanks authorizing design or construction alternatives (Alternate Arrangements) approved by the Associate Administrator (see § 178.274(a)(2)) must be indicated on the plate as specified in § 178.274(i).

    (ii) Issue an approval certificate for each portable tank or, in the case of a series of identical portable tanks manufactured to a single design type, for each series of portable tanks. The approval certificate must include all the information required to be displayed on the required metal identification plate required by § 178.270-14 of this subchapter for IM portable tanks, § 178.245-6 for Specification 51 steel portable tanks, or § 178.274(i) for UN portable tanks. The approval certificate must certify that the approval agency designated to approve the portable tank has approved the portable tank in accordance with the procedures in subpart E of part 107 of this subchapter and that the portable tank is suitable for its intended purpose and meets the requirements of this subchapter. When a series of portable tanks is manufactured without change in the design type, the certificate may be valid for the entire series of portable tanks representing a single design type. For UN portable tanks, the certificate must refer to the prototype test report, the hazardous material or group of hazardous materials allowed to be transported, the materials of construction of the shell and lining (when applicable) and an approval number. The approval number must consist of the distinguishing sign or mark of the country (“USA” for the United States of America) where the approval was granted and a registration number.Start Printed Page 33440

    (iii) Retain a copy of each approval certificate.

    (8) For UN portable tanks, the approval certificate must also include the following:

    (i) The results of the applicable framework and rail impact test specified in part 180, subpart G, of this subchapter; and

    (ii) The results of the initial inspection and test in § 180.605 of this subchapter.

    (9) The approval agency shall be independent from the manufacturer. The approval agency and the authorized inspector may be the same entity.

    (c) Manufacturers' responsibilities. The manufacturer is responsible for compliance with the applicable specifications for the design and construction of portable tanks. In addition to responsibility for compliance, manufacturers are responsible for ensuring that the contracted approval agency and authorized inspector, if applicable, are qualified, reputable and competent. The manufacturer of a portable tank shall—

    (1) Comply with all the applicable requirements of the ASME Code (see § 171.7 of this subchapter) and of this subpart including, but not limited to, ensuring that the quality control, design calculations and required tests are performed and that all aspects of the portable tank meet the applicable requirements.

    (2) Obtain and use a designated approval agency, if applicable, and obtain and use a DOT-designated approval agency to approve the design, construction and certification of the portable tank.

    (3) Provide a statement in the manufacturers' data report certifying that each portable tank that is manufactured complies with the relevant specification and all the applicable requirements of this subchapter.

    (4) Maintain records of the qualification of portable tanks for at least 5 years and provide copies to the approval agency, the owner or lessee of the tank. Upon request, provide these records to a representative of DOT.

    (d) Denial of application for approval. If an approval agency finds that a portable tank cannot be approved for any reason, it shall notify the applicant in writing and shall provide the applicant with the reasons for which the approval is denied. A copy of the notification letter shall be provided to the Associate Administrator. An applicant aggrieved by a decision of an approval agency may appeal the decision in writing, within 90 days of receipt, to the Associate Administrator.

    (e) Modifications to approved portable tanks. (1) Prior to modification of any approved portable tank which may affect conformance and the safe use of an IM or UN portable tank, which may involve a change to the design type or which may affect its ability to retain the hazardous material in transportation, the person desiring to make such modification shall inform the approval agency that issued the initial approval of the portable tank (or if unavailable another approval agency) of the nature of the modification and request approval of the modification. The person desiring to modify the tank must supply the approval agency with three sets of all revised drawings, calculations, and test data relative to the intended modification.

    (2) A statement as to whether the intended modification has been examined and determined to be unacceptable by any approval agency. The written statement must include the name of the approving agency, the reason for nonacceptance, and the nature of changes made to the modification since its original rejection.

    (3) The approval agency shall review the request for modification, and if it is determined that the proposed modification is in full compliance with the relevant DOT specification, including a UN portable tank, the request shall be approved and the approval agency shall perform the following activities:

    (i) Return one set of the approved revised drawings, calculations, and test data to the applicant. The second and third sets of the approved revised drawings, calculations, and data shall be retained by the approval agency as required in § 107.404(a)(3) of this subchapter.

    (ii) Ensure through appropriate inspection that all modifications conform to the revised drawings, calculations, and test data.

    (iii) Determine the extent to which retesting of the modified tank is necessary based on the nature of the proposed modification, and ensure that all required retests are satisfactorily performed.

    (iv) If modification to an approved tank alters any information on the approval certificate, issue a new approval certificate for the modified tank and ensure that any necessary changes are made to the metal identification plate. A copy of each newly issued approval certificate shall be retained by the approval agency and by the owner of each portable tank.

    (4) If the approval agency determines that the proposed modification is not in compliance with the relevant DOT specification, the approval agency shall deny the request in accordance with paragraph (d) of this section.

    (f) Termination of Approval Certificate. (1) The Associate Administrator may terminate an approval issued under this section if he determines that—

    (i) Information upon which the approval was based is fraudulent or substantially erroneous; or

    (ii) Termination of the approval is necessary to adequately protect against risks to life and property; or

    (iii) The approval was not issued by the approval agency in good faith; or

    (iv) The portable tank does not meet the specification.

    (2) Before an approval is terminated, the Associate Administrator gives the interested party(ies):

    (i) Written notice of the facts or conduct believed to warrant the termination;

    (ii) Opportunity to submit oral and written evidence; and

    (iii) Opportunity to demonstrate or achieve compliance with the applicable requirements.

    (3) If the Associate Administrator determines that a certificate of approval must be terminated to preclude a significant and imminent adverse affect on public safety, he may terminate the certificate immediately. In such circumstances, the opportunities of paragraphs (f)(2) (ii) and (iii) of this section need not be provided prior to termination of the approval, but shall be provided as soon as practicable thereafter.

    Start Amendment Part

    71. Section 178.274 is added to subpart H to read as follows:

    End Amendment Part
    Specifications for UN portable tanks.

    (a) General. (1) Each UN portable tank must meet the requirements of this section. In addition to the requirements of this section, requirements specific to UN portable tanks used for liquid and solid hazardous materials, non-refrigerated liquefied gases and refrigerated liquefied gases are provided in §§ 178.275, 178.276 and 178.277, respectively. Requirements for approval, maintenance, inspection, testing and use are provided in § 178.273 and part 180, subpart G, of this subchapter. Any portable tank which meets the definition of a “container” within the terms of the International Convention for Safe Containers (CSC) must meet the requirements of the CSC as amended and 49 CFR parts 450 through 453 and must have a CSC safety approval plate.

    (2) In recognition of scientific and technological advances, the technical requirements applicable to UN portable Start Printed Page 33441tanks may be varied if approved by the Associate Administrator and the portable tank is shown to provide a level of safety equal to or exceeding the requirements of this subchapter. Portable tanks approved to alternative technical requirements must be marked “Alternative Arrangement” as specified in paragraph (i) of this section.

    (3) Definitions. The following definitions apply for the purposes of design and construction of UN portable tanks under this subpart:

    Alternate Arrangement portable tank means a UN portable tank that has been approved to alternative technical requirements or testing methods other than those specified for UN portable tanks in part 178 or part 180 of this subchapter.

    Approval agency means the designated approval agency authorized to approve the portable tank in accordance with the procedures in subpart E of part 107 of this subchapter.

    Design pressure is defined according to the hazardous materials intended to be transported in the portable tank. See §§ 178.275, 178.276 and 178.277, as applicable.

    Design type means a portable tank or series of portable tanks made of materials of the same material specifications and thicknesses, manufactured by a single manufacturer, using the same fabrication techniques (for example, welding procedures) and made with equivalent structural equipment, closures, and service equipment.

    Fine grain steel means steel which has a ferritic grain size of 6 or finer when determined in accordance with ASTM E 112-96 (see § 171.7 of this subchapter).

    Fusible element means a non-reclosing pressure relief device that is thermally activated and that provides protection against excessive pressure buildup in the portable tank developed by exposure to heat, such as from a fire (see § 178.275(g)).

    Jacket means the outer insulation cover or cladding which may be part of the insulation system.

    Leakage test means a test using gas to subject the shell and its service equipment to an internal pressure.

    Maximum allowable working pressure (MAWP) is defined according to the hazardous materials intended to be transported in the portable tank. See §§ 178.275, 178.276 and 178.277, as applicable.

    Maximum permissible gross mass (MPGM) means the sum of the tare mass of the portable tank and the heaviest hazardous material authorized for transportation.

    Mild steel means a steel with a guaranteed minimum tensile strength of 360 N/mm2 to 440 N/mm2 and a guaranteed minimum elongation at fracture as specified in paragraph (c)(10) of this section.

    Offshore portable tank means a portable tank specially designed for repeated use in the transportation of hazardous materials to, from and between offshore facilities. An offshore portable tank is designed and constructed in accordance with the Guidelines for the Approval of Containers Handled in Open Seas specified in the IMDG Code (see § 171.7 of this subchapter).

    Reference steel means a steel with a tensile strength of 370 N/mm2 and an elongation at fracture of 27%.

    Service equipment means measuring instruments and filling, discharge, venting, safety, heating, cooling and insulating devices.

    Shell means the part of the portable tank which retains the hazardous materials intended for transportation, including openings and closures, but does not include service equipment or external structural equipment.

    Structural equipment means the reinforcing, fastening, protective and stabilizing members external to the shell.

    Test pressure means the maximum gauge pressure at the top of the shell during the hydraulic pressure test equal to not less than 1.5 times the design pressure for liquids and 1.3 for liquefied compressed gases. In some instances a pneumatic test is authorized as an alternative to the hydraulic test. The minimum test pressures for portable tanks intended for specific liquid and solid hazardous materials are specified in the applicable portable tank T codes (such as T1-T23) assigned to these hazardous materials in the § 172.101 Table of this subchapter.

    (b) General design and construction requirements. (1) The design temperature range for the shell must be −40 °C to 50 °C (−40 °F to 122 °F) for hazardous materials transported under normal conditions of transportation, except for portable tanks used for refrigerated liquefied gases where the minimum design temperature must not be higher than the lowest (coldest) temperature (for example, service temperature) of the contents during filling, discharge or transportation. For hazardous materials handled under elevated temperature conditions, the design temperature must not be less than the maximum temperature of the hazardous material during filling, discharge or transportation. More severe design temperatures must be considered for portable tanks subjected to severe climatic conditions (for example, portable tanks transported in arctic regions). Shells must be designed and constructed in accordance with the requirements of the ASME Code, Section VIII, Division 1 (see § 171.7 of this subchapter), except as limited or modified in this subchapter. For portable tanks used for liquid or solid hazardous materials, a design code other than the ASME Code may be used if approved by the Associate Administrator. Portable tanks used for non-refrigerated and refrigerated liquified compressed gases require an ASME certification and U stamp. Shells must be made of metallic materials suitable for forming. Non-metallic materials may be used for the attachments and supports between the shell and jacket, provided their material properties at the minimum and maximum design temperatures are proven to be sufficient. For welded shells, only a material whose weldability has been fully demonstrated may be used. Welds must be of high quality and conform to a level of integrity at least equivalent to the welding requirements specified in Section VIII of the ASME Code for the welding of pressure vessels. When the manufacturing process or the materials make it necessary, the shells must be suitably heat-treated to guarantee adequate toughness in the weld and in the heat-affected zones. In choosing the material, the design temperature range must be taken into account with respect to risk of brittle fracture, stress corrosion cracking, resistance to impact, and suitability for the hazardous materials intended for transportation in the portable tank. When fine grain steel is used, the guaranteed value of the yield strength must be not more than 460 N/mm2 and the guaranteed value of the upper limit of the tensile strength must be not more than 725 N/mm2 according to the material specification. Aluminum may not be used as a construction material for the shells of portable tanks intended for the transport of non-refrigerated liquefied gases. For portable tanks intended for the transport of liquid or solid hazardous materials, aluminum may only be used as a construction material for portable tank shells if approved by the Associate Administrator. Portable tank materials must be suitable for the external environment where they will be transported, taking into account the determined design temperature range. Portable tanks shall be designed to withstand, without loss of contents, at least the internal pressure due to the Start Printed Page 33442contents and the static, dynamic and thermal loads during normal conditions of handling and transportation. The design must take into account the effects of fatigue, caused by repeated application of these loads through the expected life of the portable tank.

    (2) Portable tank shells, fittings, and pipework shall be constructed from materials that are:

    (i) Compatible with the hazardous materials intended to be transported; or

    (ii) Properly passivated or neutralized by chemical reaction, if applicable; or

    (iii) For portable tanks used for liquid and solid materials, lined with corrosion-resistant material directly bonded to the shell or attached by equivalent means.

    (3) Gaskets and seals shall be made of materials that are compatible with the hazardous materials intended to be transported.

    (4) When shells are lined, the lining must be compatible with the hazardous materials intended to be transported, homogeneous, non-porous, free from perforations, sufficiently elastic and compatible with the thermal expansion characteristics of the shell. The lining of every shell, shell fittings and piping must be continuous and must extend around the face of any flange. Where external fittings are welded to the tank, the lining must be continuous through the fitting and around the face of external flanges. Joints and seams in the lining must be made by fusing the material together or by other equally effective means.

    (5) Contact between dissimilar metals which could result in damage by galvanic action must be prevented by appropriate measures.

    (6) The construction materials of the portable tank, including any devices, gaskets, linings and accessories, must not adversely affect or react with the hazardous materials intended to be transported in the portable tank.

    (7) Portable tanks must be designed and constructed with supports that provide a secure base during transportation and with suitable lifting and tie-down attachments.

    (c) Design criteria. (1) Portable tanks and their fastenings must, under the maximum permissible loads and maximum permissible working pressures, be capable of absorbing the following separately applied static forces (for calculation purposes, acceleration due to gravity (g) =9.81m/s2):

    (i) In the direction of travel: 2g (twice the MPGM multiplied by the acceleration due to gravity);

    (ii) Horizontally at right angles to the direction of travel: 1g (the MPGM multiplied by the acceleration due to gravity);

    (iii) Vertically upwards: 1g (the MPGM multiplied by the acceleration due to gravity); and

    (iv) Vertically downwards: 2g (twice the MPGM multiplied by the acceleration due to gravity).

    (2) Under each of the forces specified in paragraph (c)(1) of this section, the safety factor must be as follows:

    (i) For metals having a clearly defined yield point, a design margin of 1.5 in relation to the guaranteed yield strength; or

    (ii) For metals with no clearly defined yield point, a design margin of 1.5 in relation to the guaranteed 0.2% proof strength and, for austenitic steels, the 1% proof strength.

    (3) The values of yield strength or proof strength must be the values according to recognized material standards. When austenitic steels are used, the specified minimum values of yield strength or proof strength according to the material standards may be increased by up to 15% for portable tanks used for liquid and solid hazardous materials, other than toxic by inhalation liquids meeting the criteria of Hazard Zone A or Hazard Zone B (see § 173.133 of this subchapter), when these greater values are attested in the material inspection certificate.

    (4) Portable tanks must be capable of being electrically grounded to prevent dangerous electrostatic discharge when they are used for Class 2 flammable gases or Class 3 flammable liquids, including elevated temperature materials transported at or above their flash point.

    (5) For shells of portable tanks used for liquefied compressed gases, the shell must consist of a circular cross section. Shells must be of a design capable of being stress-analysed mathematically or experimentally by resistance strain gauges as specified in UG-101, Section VIII of the ASME Code (see § 171.7 of this subchapter), or other methods approved by the Associate Administrator.

    (6) Shells must be designed and constructed to withstand a hydraulic test pressure of not less than 1.5 times the design pressure for portable tanks used for liquids and 1.3 times the design pressure for portable tanks used for liquefied compressed gases. Specific requirements are provided for each hazardous material in the applicable T Code or portable tank special provision specified in the § 172.101 Table of this subchapter. The minimum shell thickness requirements must also be taken into account.

    (7) For metals exhibiting a clearly defined yield point or characterized by a guaranteed proof strength (0.2% proof strength, generally, or 1% proof strength for austenitic steels), the primary membrane stress σ (sigma) in the shell must not exceed 0.75 Re or 0.50 Rm, whichever is lower, at the test pressure, where:

    Re = yield strength in N/mm2, or 0.2% proof strength or, for austenitic steels, 1% proof strength;

    Rm = minimum tensile strength in N/mm2.

    (8) The values of Re and Rm to be used must be the specified minimum values according to recognized material standards. When austenitic steels are used, the specified minimum values for Re and Rm according to the material standards may be increased by up to 15% when greater values are attested in the material inspection certificate.

    (9) Steels which have a Re/Rm ratio of more than 0.85 are not allowed for the construction of welded shells. The values of Re and Rm to be used in determining this ratio must be the values specified in the material inspection certificate.

    (10) Steels used in the construction of shells must have an elongation at fracture, in percentage, of not less than 10,000/Rm with an absolute minimum of 16% for fine grain steels and 20% for other steels.

    (11) For the purpose of determining actual values for materials for sheet metal, the axis of the tensile test specimen must be at right angles (transversely) to the direction of rolling. The permanent elongation at fracture must be measured on test specimens of rectangular cross sections in accordance with ISO 6892 (see § 171.7 of this subchapter), using a 50 mm gauge length.

    (d) Minimum shell thickness. (1) The minimum shell thickness must be the greatest thickness of the following:

    (i) the minimum thickness determined in accordance with the requirements of paragraphs (d)(2) through (d)(10) of this section;

    (ii) the minimum thickness determined in accordance with Section VIII of the ASME Code (see § 171.7 of this subchapter) or other approved pressure vessel code; or

    (iii) the minimum thickness specified in the applicable T code or portable tank special provision indicated for each hazardous material in the § 172.101 Table of this subchapter.

    (2) Shells (cylindrical portions, heads and manhole covers) not more than 1.80 m in diameter may not be less than 5 mm thick in the reference steel or of Start Printed Page 33443equivalent thickness in the metal to be used. Shells more than 1.80 m in diameter may not be less than 6 mm (0.2 inches) thick in the reference steel or of equivalent thickness in the metal to be used. For portable tanks used only for the transportation of powdered or granular solid hazardous materials of Packing Group II or III, the minimum thickness requirement may be reduced to 5 mm in the reference steel or of equivalent thickness in the metal to be used regardless of the shell diameter. For vacuum-insulated tanks, the aggregate thickness of the jacket and the shell must correspond to the minimum thickness prescribed in this paragraph, with the thickness of the shell itself not less than the minimum thickness prescribed in paragraph (d)(3) of this section.

    (3) When additional protection against shell damage is provided in the case of portable tanks used for liquid and solid hazardous materials requiring test pressures less than 2.65 bar (265.0 kPa), subject to certain limitations specified in the UN Recommendations (see § 171.7 of this subchapter), the Associate Administrator may approve a reduced minimum shell thickness.

    (4) The cylindrical portions, heads and manhole covers of all shells must not be less than 3 mm (0.1 inch) thick regardless of the material of construction, except for portable tanks used for liquefied compressed gases where the cylindrical portions, ends (heads) and manhole covers of all shells must not be less than 4 mm (0.2 inch) thick regardless of the material of construction.

    (5) When steel is used, that has characteristics other than that of reference steel, the equivalent thickness of the shell and heads must be determined according to the following formula:

    Where:

    e1 = required equivalent thickness (in mm) of the metal to be used;

    e0 = minimum thickness (in mm) of the reference steel specified in the applicable T code or portable tank special provision indicated for each material in the § 172.101 Table of this subchapter;

    d1 = 1.8m, unless the formula is used to determine the equivalent minimum thickness for a portable tank shell that is required to have a minimum thickness of 8mm or 10mm according to the applicable T code indicated in the § 172.101 Table of this subchapter. When reference steel thicknesses of 8mm or 10mm are specified, d1 is equal to the actual diameter of the shell but not less than 1.8m;

    Rm1 = guaranteed minimum tensile strength (in N/mm 2) of the metal to be used;

    A1 = guaranteed minimum elongation at fracture (in %) of the metal to be used according to recognized material standards.

    (6) The wall and all parts of the shell may not have a thickness less than that prescribed in paragraphs (d)(2), (d)(3) and (d)(4) of this section. This thickness must be exclusive of any corrosion allowance.

    (7) There must be no sudden change of plate thickness at the attachment of the heads to the cylindrical portion of the shell.

    (e) Service equipment. (1) Service equipment must be arranged so that it is protected against the risk of mechanical damage by external forces during handling and transportation. When the connections between the frame and the shell allow relative movement between the sub-assemblies, the equipment must be fastened to allow such movement without risk of damage to any working part. The external discharge fittings (pipe sockets, shut-off devices) and the internal stop-valve and its seating must be protected against mechanical damage by external forces (for example, by using shear sections). Each internal self-closing stop-valve must be protected by a shear section or sacrificial device located outboard of the valve. The shear section or sacrificial device must break at no more than 70% of the load that would cause failure of the internal self-closing stop valve. The filling and discharge devices (including flanges or threaded plugs) and any protective caps must be capable of being secured against unintended opening.

    (2) Each filling or discharge opening of a portable tank must be clearly marked to indicate its function.

    (3) Each stop-valve or other means of closure must be designed and constructed to a rated pressure not less than the MAWP of the shell taking into account the temperatures expected during transport. All stop-valves with screwed spindles must close by a clockwise motion of the handwheel. For other stop-valves, the position (open and closed) and direction of closure must be clearly indicated. All stop-valves must be designed to prevent unintentional opening.

    (4) Piping must be designed, constructed and installed to avoid the risk of damage due to thermal expansion and contraction, mechanical shock and vibration. All piping must be of a suitable metallic material. Welded pipe joints must be used wherever possible.

    (5) Joints in copper tubing must be brazed or have an equally strong metal union. The melting point of brazing materials must be no lower than 525°C (977°F). The joints must not decrease the strength of the tubing, such as may happen when cutting threads. Brazed joints are not authorized for portable tanks intended for refrigerated liquefied gases.

    (6) The burst pressure of all piping and pipe fittings must be greater than the highest of four times the MAWP of the shell or four times the pressure to which it may be subjected in service by the action of a pump or other device (except pressure relief devices).

    (7) Ductile metals must be used in the construction of valves and accessories.

    (f) Pressure relief devices.— (1) Marking of pressure relief devices. Every pressure relief device must be clearly and permanently marked with the following:

    (i) the pressure (in bar or kPa) or temperature for fusible elements (in °C) at which it is set to discharge;

    (ii) the allowable tolerance at the discharge pressure for reclosing devices;

    (iii) the reference temperature corresponding to the rated pressure for frangible discs;

    (iv) the allowable temperature tolerance for fusible elements;

    (v) the rated flow capacity of the device in standard cubic meters of air per second (m3/s)determined according to ISO 4126-1 (see § 171.7 of this subchapter); and

    (vi) when practicable, the device must show the manufacturer's name and product number.

    (2) Connections to pressure relief devices. Connections to pressure relief devices must be of sufficient size to enable the required discharge to pass unrestricted to the safety device. No stop-valve may be installed between the shell and the pressure relief devices except where duplicate devices are provided for maintenance or other reasons and the stop-valves serving the devices actually in use are locked open or the stop-valves are interlocked so that at least one of the devices is always in use. There must be no obstruction in an opening leading to a vent or pressure relief device which might restrict or cut-off the flow from the shell to that device. Vents or pipes from the pressure relief device outlets, when used, must deliver the relieved vapor or liquid to the atmosphere in conditions of minimum back-pressure on the relieving devices.

    (3) Location of pressure relief devices. (i) Each pressure relief device inlet must be situated on top of the shell in a position as near the longitudinal and Start Printed Page 33444transverse center of the shell as reasonably practicable. All pressure relief device inlets must, under maximum filling conditions, be situated in the vapor space of the shell and the devices must be so arranged as to ensure that any escaping vapor is not restricted in any manner. For flammable hazardous materials, the escaping vapor must be directed away from the shell in such a manner that it cannot impinge upon the shell. For refrigerated liquefied gases, the escaping vapor must be directed away from the tank and in such a manner that it cannot impinge upon the tank. Protective devices which deflect the flow of vapor are permissible provided the required relief-device capacity is not reduced.

    (ii) Provisions must be implemented to prevent unauthorized persons from access to the pressure relief devices and to protect the devices from damage caused by the portable tank overturning.

    (g) Gauging devices. Unless a portable tank is intended to be filled by weight, it must be equipped with one or more gauging devices. Glass level-gauges and gauges made of other fragile material, which are in direct communication with the contents of the tank are prohibited. A connection for a vacuum gauge must be provided in the jacket of a vacuum-insulated portable tank.

    (h) Portable tank supports, frameworks, lifting and tie-down attachments. (1) Portable tanks must be designed and constructed with a support structure to provide a secure base during transport. The forces and safety factors specified in paragraphs (c)(1) and (c)(2) of this section, respectively, must be taken into account in this aspect of the design. Skids, frameworks, cradles or other similar structures are acceptable.

    (2) The combined stresses caused by portable tank mountings (for example, cradles, framework, etc.) and portable tank lifting and tie-down attachments must not cause stress that would damage the shell in a manner that would compromise its lading retention capability. Permanent lifting and tie-down attachments must be fitted to all portable tanks. Preferably they should be fitted to the portable tank supports but may be secured to reinforcing plates located on the shell at the points of support. Each portable tank must be designed so that the center of gravity of the filled tank is approximately centered within the points of attachment for lifting devices.

    (3) In the design of supports and frameworks, the effects of environmental corrosion must be taken into account.

    (4) Forklift pockets must be capable of being closed off. The means of closing forklift pockets must be a permanent part of the framework or permanently attached to the framework. Single compartment portable tanks with a length less than 3.65 m (12 ft.) need not have forklift pockets that are capable of being closed off provided that:

    (i) The shell, including all the fittings, are well protected from being hit by the forklift blades; and

    (ii) The distance between forklift pockets (measured from the center of each pocket) is at least half of the maximum length of the portable tank.

    (5) During transport, portable tanks must be adequately protected against damage to the shell, and service equipment resulting from lateral and longitudinal impact and overturning, or the shell and service equipment must be constructed to withstand the forces resulting from impact or overturning. External fittings must be protected so as to preclude the release of the shell contents upon impact or overturning of the portable tank on its fittings. Examples of protection include:

    (i) Protection against lateral impact which may consist of longitudinal bars protecting the shell on both sides at the level of the median line;

    (ii) Protection of the portable tank against overturning which may consist of reinforcement rings or bars fixed across the frame;

    (iii) Protection against rear impact which may consist of a bumper or frame;

    (iv) Protection of the shell against damage from impact or overturning by use of an ISO frame in accordance with ISO 1496-3 (see § 171.7 of this subchapter); and

    (v) Protection of the portable tank from impact or damage that may result from overturning by an insulation jacket.

    (i) Marking. (1) Every portable tank must be fitted with a corrosion resistant metal plate permanently attached to the portable tank in a conspicuous place and readily accessible for inspection. When the plate cannot be permanently attached to the shell, the shell must be marked with at least the information required by Section VIII of the ASME Code (see § 171.7 of this subchapter). At a minimum, the following information must be marked on the plate by stamping or by any other equivalent method:

    Country of manufacture

    U N

    Approval Country

    Approval Number

    Alternative Arrangements (see § 178.247(a)(2)) “AA”

    Manufacturer's name or mark

    Manufacturer's serial number

    Approval Agency (Authorized body for the design approval)

    Owner's registration number

    Year of manufacture

    Pressure vessel code to which the shell is designed

    Test pressure____bar gauge.

    MAWP____bar gauge.

    External design pressure (not required for portable tanks used for refrigerated liquefied gases)____bar gauge.

    Design temperature range____°C to____°C. (For portable tanks used for refrigerated liquefied gases, the minimum design temperature must be marked.)

    Water capacity at 20°C/____liters.

    Water capacity of each compartment at 20°C____liters.

    Initial pressure test date and witness identification.

    MAWP for heating/cooling system____bar gauge.

    Shell material(s) and material standard reference(s).

    Equivalent thickness in reference steel____mm.

    Lining material (when applicable).

    Date and type of most recent periodic test(s).

    Month____Year____­ Test pressure____bar gauge.

    Stamp of approval agency that performed or witnessed the most recent test.

    For portable tanks used for refrigerated liquefied gases:

    Either “thermally insulated” or “vacuum insulated”____.

    Effectiveness of the insulation system (heat influx)____Watts (W).

    Reference holding time____days or hours and initial pressure____bar/kPa gauge and degree of filling____in kg for each refrigerated liquefied gas permitted for transportation.

    (2) The following information must be marked either on the portable tank itself or on a metal plate firmly secured to the portable tank:

    Name of the operator.

    Name of hazardous materials being transported and maximum mean bulk temperature (except for refrigerated liquefied gases, the name and temperature are only required when the maximum mean bulk temperature is higher than 50°C).

    Maximum permissible gross mass (MPGM)____kg.

    Unladen (tare) mass____kg.

    Note to Paragraph (i)(2):

    For the identification of the hazardous materials being transported refer to part 172 of this subchapter.

    (3) If a portable tank is designed and approved for open seas operations, such as offshore oil exploration, in accordance with the IMDG Code, the words “OFFSHORE PORTABLE TANK” must be marked on the identification plate.Start Printed Page 33445

    (j) Initial inspection and test. The initial inspection and test of a portable tank must include the following:

    (1) A check of the design characteristics.

    (2) An internal and external examination of the portable tank and its fittings, taking into account the hazardous materials to be transported. For UN portable tanks used for refrigerated liquefied gases, a pressure test using an inert gas may be conducted instead of a hydrostatic test. An internal inspection is not required for a portable tank used for the dedicated transportation of refrigerated liquefied gases that are not filled with an inspection opening.

    (3) A pressure test as specified in paragraph (i) of this section.

    (4) A leakage test.

    (5) A test of the satisfactory operation of all service equipment including pressure relief devices must also be performed. When the shell and its fittings have been pressure-tested separately, they must be subjected to a leakage test after reassembly. All welds, subject to full stress level in the shell, must be inspected during the initial test by radiographic, ultrasonic, or another suitable non-destructive test method. This does not apply to the jacket.

    (6) A UN portable tank that meets the definition of “container” in the CSC (see 49 CFR 450.3(a)(2)) must be subjected to an impact test using a prototype representing each design type. The prototype portable tank must be shown to be capable of absorbing the forces resulting from an impact not less than 4 times (4 g) the maximum permissable gross mass of the fully loaded portable tank at a duration typical of the mechanical shocks experienced in rail transportation. A listing of standards describing methods acceptable for performing the impact test are provided in the UN Recommendations (see § 171.7 of this subchapter). UN portable tanks used for the dedicated transportation of “Helium, refrigerated liquid,” UN1963 and “Hydrogen, refrigerated liquid,” UN1966 that are marked “NOT FOR RAIL TRANSPORT” in letters of a minimum height of 20 cm (8 inches) on at least two sides of the portable tank are excepted from the 4 g impact test.

    (7) The following tests must be completed on a portable tank or a series of portable tanks designed and constructed to a single design type that is also a CSC container without leakage or deformation that would render the portable tank unsafe for transportation and use:

    (i) Longitudinal inertia. The portable tank loaded to its maximum gross weight must be positioned with its longitudinal axis vertical. It shall be held in this position for five minutes by support at the lower end of the base structure providing vertical and lateral restraint and by support at the upper end of the base structure providing lateral restraint only.

    (ii) Lateral inertia. The portable tank loaded to its maximum gross weight must be positioned for five minutes with its transverse axis vertical. It shall be held in this position for five minutes by support at the lower side of the base structure providing vertical and lateral restraint and by support at the upper side of the base structure providing lateral restraint only.

    Start Amendment Part

    72. Section 178.275 is added to subpart H to read as follows:

    End Amendment Part
    Specification for UN Portable Tanks intended for the transportation of liquid and solid hazardous materials.

    (a) In addition to the requirements of § 178.274, this section sets forth definitions and requirements that apply to UN portable tanks intended for the transportation of liquid and solid hazardous materials.

    (b) Definitions and requirements.—(1) Design pressure means the pressure to be used in calculations required by the recognized pressure vessel code. The design pressure must not be less than the highest of the following pressures:

    (i) The maximum effective gauge pressure allowed in the shell during filling or discharge; or

    (ii) The sum of—

    (A) The absolute vapor pressure (in bar) of the hazardous material at 65 °C, minus 1 bar (149 °F, minus 100 kPa);

    (B) The partial pressure (in bar) of air or other gases in the ullage space, resulting from their compression during filling without pressure relief by a maximum ullage temperature of 65 °C (149 °F) and a liquid expansion due to an increase in mean bulk temperature of 35 °C (95 °F); and

    (C) A head pressure determined on the basis of the forces specified in § 178.274(c) of this subchapter, but not less than 0.35 bar (35 kPa).

    (2) Maximum allowable working pressure (MAWP) means a pressure that must not be less than the highest of the following pressures measured at the top of the shell while in operating position:

    (i) The maximum effective gauge pressure allowed in the shell during filling or discharge; or

    (ii) The maximum effective gauge pressure to which the shell is designed which must be not less than the design pressure.

    (c) Service equipment. (1) In addition to the requirements specified in § 178.274, for service equipment, all openings in the shell, intended for filling or discharging the portable tank must be fitted with a manually operated stop-valve located as close to the shell as reasonably practicable. Other openings, except for openings leading to venting or pressure relief devices, must be equipped with either a stop-valve or another suitable means of closure located as close to the shell as reasonably practicable.

    (2) All portable tanks must be fitted with a manhole or other inspection openings of a suitable size to allow for internal inspection and adequate access for maintenance and repair of the interior. Compartmented portable tanks must have a manhole or other inspection openings for each compartment.

    (3) For insulated portable tanks, top fittings must be surrounded by a spill collection reservoir with suitable drains.

    (4) Piping must be designed, constructed and installed to avoid the risk of damage due to thermal expansion and contraction, mechanical shock and vibration. All piping must be of a suitable metallic material. Welded pipe joints must be used wherever possible.

    (d) Bottom openings. (1) Certain hazardous materials may not be transported in portable tanks with bottom openings. When the applicable T code or portable tank special provision, as referenced for materials in the § 172.101 Table of this subchapter, specifies that bottom openings are prohibited, there must be no openings below the liquid level of the shell when it is filled to its maximum permissible filling limit. When an existing opening is closed, it must be accomplished by internally and externally welding one plate to the shell.

    (2) Bottom discharge outlets for portable tanks carrying certain solid, crystallizable or highly viscous hazardous materials must be equipped with at least two serially fitted and mutually independent shut-off devices. Use of only two shut-off devices is only authorized when this paragraph is referenced in the applicable T Code indicated for each hazardous material in the § 172.101 Table of this subchapter. The design of the equipment must be to the satisfaction of the approval agency and must include:

    (i) An external stop-valve fitted as close to the shell as reasonably practicable; and

    (ii) A liquid tight closure at the end of the discharge pipe, which may be a bolted blank flange or a screw cap.

    (3) Except as provided in paragraph (c)(2) of this section, every bottom discharge outlet must be equipped with Start Printed Page 33446three serially fitted and mutually independent shut-off devices. The design of the equipment must include:

    (i) A self-closing internal stop-valve, which is a stop-valve within the shell or within a welded flange or its companion flange, such that:

    (A) The control devices for the operation of the valve are designed to prevent any unintended opening through impact or other inadvertent act;

    (B) The valve is operable from above or below;

    (C) If possible, the setting of the valve (open or closed) must be capable of being verified from the ground;

    (D) Except for portable tanks having a capacity less than 1,000 liters (264.2 gallons), it must be possible to close the valve from an accessible position on the portable tank that is remote from the valve itself within 30 seconds of actuation; and

    (E) The valve must continue to be effective in the event of damage to the external device for controlling the operation of the valve;

    (ii) An external stop-valve fitted as close to the shell as reasonably practicable;

    (iii) A liquid tight closure at the end of the discharge pipe, which may be a bolted blank flange or a screw cap; and

    (iv) For portable tanks used for the transportation of liquid materials that are flammable, pyrophoric, oxidizing or toxic, the remote means of closure must be capable of thermal activation. The thermal means of activation must activate at a temperature of not more than 121 °C (250 °F).

    (e) Pressure relief devices. All portable tanks must be fitted with at least one pressure relief device. All relief devices must be designed, constructed and marked in accordance with the requirements of this subchapter.

    (f) Vacuum-relief devices. (1) A shell which is to be equipped with a vacuum-relief device must be designed to withstand, without permanent deformation, an external pressure of not less than 0.21 bar (21.0 kPa). The vacuum-relief device must be set to relieve at a vacuum setting not greater than -0.21 bar (-21.0 kPa) unless the shell is designed for a higher external over pressure, in which case the vacuum-relief pressure of the device to be fitted must not be greater than the tank design vacuum pressure. A shell that is not fitted with a vacuum-relief device must be designed to withstand, without permanent deformation, an external pressure of not less than 0.4 bar (40.0 kPa).

    (2) Vacuum-relief devices used on portable tanks intended for the transportation of hazardous materials meeting the criteria of Class 3, including elevated temperature hazardous materials transported at or above their flash point, must prevent the immediate passage of flame into the shell or the portable tank must have a shell capable of withstanding, without leakage, an internal explosion resulting from the passage of flame into the shell.

    (g) Pressure relief devices. (1) Each portable tank with a capacity not less than 1,900 liters (501.9 gallons) and every independent compartment of a portable tank with a similar capacity, must be provided with one or more pressure relief devices of the reclosing type. Such portable tanks may, in addition, have a frangible disc or fusible element in parallel with the reclosing devices, except when the applicable T code assigned to a hazardous material requires that the frangible disc precede the pressure relief device, according to paragraph (g)(3) of this section, or when no bottom openings are allowed. The pressure relief devices must have sufficient capacity to prevent rupture of the shell due to over pressurization or vacuum resulting from filling, discharging, heating of the contents or fire.

    (2) Pressure relief devices must be designed to prevent the entry of foreign matter, the leakage of liquid and the development of any dangerous excess pressure.

    (3) When required for certain hazardous materials by the applicable T code or portable tank special provision specified for a hazardous material in the § 172.101 Table of this subchapter, portable tanks must have a pressure relief device consistent with the requirements of this subchapter. Except for a portable tank in dedicated service that is fitted with an approved relief device constructed of materials compatible with the hazardous material, the relief device system must include a frangible disc preceding (such as, between the lading and the reclosing pressure relief device) a reclosing pressure relief device. A pressure gauge or suitable tell-tale indicator for the detection of disc rupture, pin-holing or leakage must be provided in the space between the frangible disc and the pressure relief device to allow the portable tank operator to check to determine if the disc is leak free. The frangible disc must rupture at a nominal pressure 10% above the start-to-discharge pressure of the reclosable pressure relief device.

    (4) Every portable tank with a capacity less than 1,900 liters (501.9 gallons) must be fitted with a pressure relief device which, except as provided in paragraph (g)(3) of this section, may be a frangible disc when this disc is set to rupture at a nominal pressure equal to the test pressure at any temperature within the design temperature range.

    (5) When the shell is fitted for pressure discharge, a suitable pressure relief device must provide the inlet line to the portable tank and set to operate at a pressure not higher than the MAWP of the shell, and a stop-valve must be fitted as close to the shell as practicable to minimize the potential for damage.

    (6) Setting of pressure relief devices. (i) Pressure relief devices must operate only in conditions of excessive rise in temperature. The shell must not be subject to undue fluctuations of pressure during normal conditions of transportation.

    (ii) The required pressure relief device must be set to start to discharge at a nominal pressure of five-sixths of the test pressure for shells having a test pressure of not more than 4.5 bar (450 kPa) and 110% of two-thirds of the test pressure for shells having a test pressure of more than 4.5 bar (450 kPa). A self-closing relief device must close at a pressure not more than 10% below the pressure at which the discharge starts. The device must remain closed at all lower pressures. This requirement does not prevent the use of vacuum-relief or combination pressure relief and vacuum-relief devices.

    (h) Fusible elements. Fusible elements must operate at a temperature between 110°C (230°F) and 149°C (300.2°F) provided that the pressure in the shell at the fusing temperature will not exceed the test pressure. They must be placed at the top of the shell with their inlets in the vapor space and in no case may they be shielded from external heat. Fusible elements must not be utilized on portable tanks with a test pressure which exceeds 2.65 bar (265.0 kPa). Fusible elements used on portable tanks intended for the transport of elevated temperature hazardous materials must be designed to operate at a temperature higher than the maximum temperature that will be experienced during transport and must be designed to the satisfaction of the approval agency.

    (i) Capacity of pressure relief devices. (1) The reclosing pressure relief device required by paragraph (g)(1) of this section must have a minimum cross sectional flow area equivalent to an orifice of 31.75 mm (1.3 inches) diameter. Vacuum-relief devices, when used, must have a cross sectional flow area not less than 284 mm 2 (11.2 inches 2).

    (2) Under conditions of complete fire engulfment of the portable tank, the combined delivery capacity of the relief Start Printed Page 33447devices must be sufficient to limit the pressure in the shell to 20% above the start-to-discharge pressure specified in paragraph (g)(6) of this section. Emergency pressure relief devices may be used to achieve the full relief capacity prescribed. The total required capacity of the relief devices may be determined using the formula in paragraph (i)(2)(i)(A) of this section or the table in paragraph (i)(2)(iii) of this section.

    (i)(A) To determine the total required capacity of the relief devices, which must be regarded as being the sum of the individual capacities of all the contributing devices, the following formula must be used:

    Where:

    Q = minimum required rate of discharge in cubic meters of air per second (m 3/s) at standard conditions: 1 bar and 0°C (273 K);

    F = for uninsulated shells: 1; for insulated shells: U(649-t)/13.6 but in no case is less than 0.25 where: U = thermal conductance of the insulation, in kW·m2 K1, at 38°C; and t = actual temperature of the hazardous material during filling (in °C) or when this temperature is unknown, let t = 15°C. The value of F given in this paragraph (i)(2)(i)(A) for insulated shells may only be used if the insulation is in conformance with paragraph (i)(2)(iv) of this section;

    A = total external surface area of shell in square meters;

    Z = the gas compressibility factor in the accumulating condition (when this factor is unknown, let Z equal 1.0);

    T = absolute temperature in Kelvin (°C + 273) above the pressure relief devices in the accumulating condition;

    L = the latent heat of vaporization of the liquid, in kJ/kg, in the accumulating condition;

    M = molecular weight of the hazardous material.

    (B) The constant C, as shown in the formula in paragraph (i)(2)(i)(A) of this section, is derived from one of the following formula as a function of the ratio k of specific heats:

    Where:

    cp is the specific heat at constant pressure; and

    cv is the specific heat at constant volume.

    (C) When k >1:

    (D) When k = 1 or k is unknown, a value of 0.607 may be used for the constant C. C may also be taken from the following table:

    C Constant Value Table

    k  Ck  Ck  C
    1.00  0.6071.26  0.6601.52  0.704
    1.02  0.6111.28  0.6641.54  0.707
    1.04  0.6151.30  0.6671.56  0.710
    1.06  0.6201.32  0.6711.58  0.713
    1.08  0.6241.34  0.6741.60  0.716
    1.10  0.6281.36  0.6781.62  0.719
    1.12  0.6331.38  0.6811.64  0.722
    1.14  0.6371.40  0.6851.66  0.725
    1.16  0.6411.42  0.6881.68  0.728
    1.18  0.6451.44  0.6911.70  0.731
    1.20  0.6491.46  0.6952.00  0.770
    1.22  0.6521.48  0.6982.20  0.793
    1.24  0.6561.50  0.701

    (ii) As an alternative to the formula in paragraph (i)(2)(i)(A) of this section, relief devices for shells used for transporting liquids may be sized in accordance with the table in paragraph (i)(2)(iii) of this section. The table in paragraph (i)(2)(iii) of this section assumes an insulation value of F = 1 and must be adjusted accordingly when the shell is insulated. Other values used in determining the table in paragraph (i)(2)(iii) of this section are: L = 334.94 kJ/kg; M = 86.7; T = 394 K; Z = 1; and C = 0.607.

    (iii) Minimum emergency vent capacity, Q, in cubic meters per air per second at 1 bar and 0°C (273 K) shown in the following table:

    Minimum Emergency Vent Capacity

    [Q Values]

    A Exposed area (square meters)Q (Cubic meters of air per second)A Exposed area (square meters)Q (Cubic meters of air per second)
    20.23037.52.539
    30.320402.677
    40.40542.52.814
    50.487452.949
    60.56547.53.082
    70.641503.215
    80.71552.53.346
    90.788553.476
    100.85957.53.605
    120.998603.733
    141.13262.53.860
    161.263653.987
    181.39167.54.112
    Start Printed Page 33448
    201.517704.236
    22.51.670754.483
    251.821804.726
    27.51.969854.967
    302.115905.206
    32.52.258955.442
    352.4001005.676

    (iv) Insulation systems, used for the purpose of reducing venting capacity, must be specifically approved by the approval agency. In all cases, insulation systems approved for this purpose must—

    (A) Remain effective at all temperatures up to 649 °C (1200.2 °F); and

    (B) Be jacketed with a material having a melting point of 700 °C (1292 °F) or greater.

    (j) Approval, inspection and testing. Approval procedures for UN portable tanks are specified in § 178.273. Inspection and testing requirements are specified in § 180.605 of this subchapter.

    Start Amendment Part

    73. Section 178.276 is added to subpart H to read as follows:

    End Amendment Part
    Requirements for the design, construction, inspection and testing of portable tanks intended for the transportation of non-refrigerated liquefied compressed gases.

    (a) In addition to the requirements of § 178.274 applicable to UN portable tanks, the following requirements apply to UN portable tanks used for non-refrigerated liquefied compressed gases. In addition to the definitions in § 178.274, the following definitions apply:

    (1) Design pressure means the pressure to be used in calculations required by the ASME Code, Section VIII (see § 171.7 of this subchapter). The design pressure must be not less than the highest of the following pressures:

    (i) The maximum effective gauge pressure allowed in the shell during filling or discharge; or

    (ii) The sum of:

    (A) The maximum effective gauge pressure to which the shell is designed as defined in this paragraph under “MAWP”; and

    (B) A head pressure determined on the basis of the dynamic forces specified in paragraph (h) of this section, but not less than 0.35 bar (35 kPa).

    (2) Design reference temperature means the temperature at which the vapor pressure of the contents is determined for the purpose of calculating the MAWP. The value for each portable tank type is as follows:

    (i) Shell with a diameter of 1.5 meters (4.9 ft.) or less: 65 °C (149 °F); or

    (ii) Shell with a diameter of more than 1.5 meters (4.9 ft.):

    (A) Without insulation or sun shield: 60 °C (140 °F);

    (B) With sun shield: 55 °C (131 °F); and

    (C) With insulation: 50 °C (122 °F).

    (3) Filling density means the average mass of liquefied compressed gas per liter of shell capacity (kg/l).

    (4) Maximum allowable working pressure (MAWP) means a pressure that must be not less than the highest of the following pressures measured at the top of the shell while in operating position, but in no case less than 7 bar (700 kPa):

    (i) The maximum effective gauge pressure allowed in the shell during filling or discharge; or

    (ii) The maximum effective gauge pressure to which the shell is designed, which must be:

    (A) Not less than the pressure specified for each liquefied compressed gas listed in portable tank special provision T50; and

    (B) Not less than the sum of:

    (1) The absolute vapor pressure (in bar) of the liquefied compressed gas at the design reference temperature minus 1 bar; and

    (2) The partial pressure (in bar) of air or other gases in the ullage space which is determined by the design reference temperature and the liquid phase expansion due to the increase of the mean bulk temperature of tr-tf (tf = filling temperature, usually 15 °C, tr = 50 °C maximum mean bulk temperature).

    (b) General design and construction requirements. (1) Shells must be of seamless or welded steel construction, or combination of both, and have a water capacity greater than 450 liters (118.9 gallons). Shells must be designed, constructed, certified and stamped in accordance with the ASME Code, Section VIII (see § 171.7 of this subchapter).

    (2) Portable tanks must be postweld heat-treated and radiographed as prescribed in Section VIII of the ASME Code, except that each portable tank constructed in accordance with part UHT of the ASME Code must be postweld heat-treated. Where postweld heat treatment is required, the portable tank must be treated as a unit after completion of all the welds in and/or to the shell and heads. The method must be as prescribed in the ASME Code. Welded attachments to pads may be made after postweld heat treatment is made. A portable tank used for anhydrous ammonia must be postweld heat-treated. The postweld heat treatment must be as prescribed in the ASME Code, but in no event at less than 1050 °F tank metal temperature. Additionally, portable tanks constructed in accordance with part UHT of the ASME Code must conform to the following requirements:

    (i) Welding procedure and welder performance tests must be made annually in accordance with Section IX of the ASME Code (see § 171.7 of this subchapter). In addition to the essential variables named therein, the following must be considered to be essential variables: number of passes, thickness of plate, heat input per pass, and manufacturer's identification of rod and flux. The number of passes, thickness of plate and heat input per pass may not vary more than 25 percent from the qualified procedure. Records of the qualification must be retained for at least 5 years by the portable tank manufacturer or his designated agent and, upon request, made available to a representative of the Department of Transportation or the owner of the tank.

    (ii) Impact tests must be made on a lot basis. A lot is defined as 100 tons or less of the same heat and having a thickness variation no greater than plus or minus 25 percent. The minimum impact required for full-sized specimens shall Start Printed Page 33449be 20 foot-pounds (or 10 foot-pounds for half-sized specimens) at 0 °F (−17.8 °F) Charpy V-Notch in both the longitudinal and transverse direction. If the lot test does not pass this requirement, individual plates may be accepted if they individually meet this impact requirement.

    (3) When the shells intended for the transportation of non-refrigerated liquefied compressed gases are equipped with thermal insulation, a device must be provided to prevent any dangerous pressure from developing in the insulating layer in the event of a leak, when the protective covering is closed it must be gas tight. The thermal insulation must not inhibit access to the fittings and discharge devices. In addition, the thermal insulation systems must satisfy the following requirements:

    (i) consist of a shield covering not less than the upper third, but not more than the upper half of the surface of the shell, and separated from the shell by an air space of approximately 40 mm (1.7 inches) across; or

    (ii) consist of a complete cladding of insulating materials. The insulation must be of adequate thickness and constructed to prevent the ingress of moisture and damage to the insulation. The insulation and cladding must have a thermal conductance of not more than 0.67 (W·m−2·K−1) under normal conditions of transportation.

    (c) Service equipment. (1) Each opening with a diameter of more than 1.5 mm (0.1 inch) in the shell of a portable tank, except openings for pressure-relief devices, inspection openings and closed bleed holes, must be fitted with at least three mutually independent shut-off devices in series: the first being an internal stop-valve, excess flow valve, integral excess flow valve, or excess flow feature (see § 178.337-1(g)), the second being an external stop-valve and the third being a blank flange, thread cap, plug or equivalent tight liquid closure device.

    (2) When a portable tank is fitted with an excess flow valve, the excess flow valve must be so fitted that its seating is inside the shell or inside a welded flange or, when fitted externally, its mountings must be designed so that in the event of impact it maintains its effectiveness. The excess flow valves must be selected and fitted so as to close automatically when the rated flow, specified by the manufacturer, is reached. Connections and accessories leading to or from such a valve must have a capacity for a flow more than the excess flow valve's rated flow.

    (3) For filling and discharge openings that are located below the liquid level, the first shut-off device must be an internal stop-valve and the second must be a stop-valve placed in an accessible position on each discharge and filling pipe.

    (4) For filling and discharge openings located below the liquid level of portable tanks intended for the transportation of flammable and/or toxic liquefied compressed gases, the internal stop-valve must be a self-closing safety device that fully closes automatically during filling or discharge in the event of fire engulfment. The device shall fully close within 30 seconds of actuation and the thermal means of closure must actuate at a temperature of not more than 121 °C (250 °F). Except for portable tanks having a capacity less than 1,000 liters (264.2 gallons), this device must be operable by remote control.

    (5) In addition to filling, discharge and gas pressure equalizing orifices, shells may have openings in which gauges, thermometers and manometers can be fitted. Connections for such instruments must be made by suitable welded nozzles or pockets and may not be connected by screwed connections through the shell.

    (6) All portable tanks must be fitted with manholes or other inspection openings of suitable size to allow for internal inspection and adequate access for maintenance and repair of the interior.

    (7) Inlets and discharge outlets on chlorine portable tanks. The inlet and discharge outlets on portable tanks used to transport chlorine must meet the requirements of § 178.337-1(c)(2) and must be fitted with an internal excess flow valve. In addition to the internal excess flow valve, the inlet and discharge outlets must be equipped with an external stop valve (angle valve). Excess flow valves must conform to the standards of The Chlorine Institute, Inc. (see § 171.7 of this subchapter) as follows:

    (i) A valve conforming to Drawing 101-7, dated July 1993, must be installed under each liquid angle valve.

    (ii) A valve conforming to Drawing 106-6, dated July 1993, must be installed under each gas angle valve. For portable tanks used to transport non-refrigerated liquefied gases.

    (8) External fittings must be grouped together as close as reasonably practicable. The following openings may be installed at locations other than on the top or end of the tank:

    (i) The openings for liquid level gauging devices, pressure gauges, or for safety devices, may be installed separately at the other location or in the side of the shell;

    (ii) One plugged opening of 2-inch National Pipe Thread or less provided for maintenance purposes may be located elsewhere;

    (iii) An opening of 3-inch National Pipe Size or less may be provided at another location, when necessary, to facilitate installation of condensing coils.

    (9) Filling and discharge connections are not required to be grouped and may be installed below the normal liquid level of the tank if:

    (i) The portable tank is permanently mounted in a full framework for containerized transport;

    (ii) For each portable tank design, a prototype portable tank, meets the requirements of parts 450 through 453 of this title for compliance with the requirements of Annex II of the International Convention for Safe Containers; and

    (iii) Each filling and discharge outlet meets the requirements of paragraph (c)(4) of this section.

    (d) Bottom openings. Bottom openings are prohibited on portable tanks when the portable tank special provision T50 in § 172.102(c)(7) of this subchapter indicates that bottom openings are not allowed. In this case, there may be no openings located below the liquid level of the shell when it is filled to its maximum permissible filling limit.

    (e) Pressure relief devices. (1) Portable tanks must be provided with one or more reclosing pressure relief devices. The pressure relief devices must open automatically at a pressure not less than the MAWP and be fully open at a pressure equal to 110% of the MAWP. These devices must, after discharge, close at a pressure not less than 10% below the pressure at which discharge starts and must remain closed at all lower pressures. The pressure relief devices must be of a type that will resist dynamic forces including liquid surge. A frangible disc may only be used in series with a reclosing pressure relief device.

    (2) Pressure relief devices must be designed to prevent the entry of foreign matter, the leakage of gas and the development of any dangerous excess pressure.

    (3) A portable tank intended for the transportation of certain liquefied compressed gases identified in portable tank special provision T50 in § 172.102 of this subchapter must have a pressure relief device which conforms to the requirements of this subchapter. Unless a portable tank, in dedicated service, is fitted with a relief device constructed of materials compatible with the hazardous material, the relief device must be comprised of a frangible disc Start Printed Page 33450preceded by a reclosing device. The space between the frangible disc and the device must be provided with a pressure gauge or a suitable tell-tale indicator. This arrangement must facilitate the detection of disc rupture, pinholing or leakage which could cause a malfunction of the pressure relief device. The frangible disc must rupture at a nominal pressure 10% above the start-to-discharge pressure of the relief device.

    (4) In the case of portable tanks used for more than one gas, the pressure relief devices must open at a pressure indicated in paragraph (e)(1) of this section for the gas having the highest maximum allowable pressure of the gases allowed to be transported in the portable tank.

    (f) Capacity of relief devices. The combined delivery capacity of the relief devices must be sufficient so that, in the event of total fire engulfment, the pressure inside the shell cannot exceed 120% of the MAWP. Reclosing relief devices must be used to achieve the full relief capacity prescribed. In the case of portable tanks used for more than gas, the combined delivery capacity of the pressure relief devices must be taken for the liquefied compressed gas which requires the highest delivery capacity of the liquefied compressed gases allowed to be transported in the portable tank. The total required capacity of the relief devices must be determined according to the requirements in § 178.275(h). These requirements apply only to liquefied compressed gases which have critical temperatures well above the temperature at the accumulating condition. For gases which have critical temperatures near or below the temperature at the accumulating condition, the calculation of the pressure relief device delivery capacity must consider the additional thermodynamic properties of the gas (for example, CGA S-1.2-1980 (see § 171.7 of this subchapter).

    Start Amendment Part

    74. A new § 178.277 is added to subpart H to read as follows:

    End Amendment Part
    Requirements for the design, construction, inspection and testing of portable tanks intended for the transportation of refrigerated liquefied gases.

    (a) In addition to the requirements of § 178.274 applicable to UN portable tanks, the following requirements and definitions apply to UN portable tanks used for refrigerated liquefied gases:

    Design pressure For the purpose of this section the term “design pressure” is consistent with the definition for design pressure in the ASME Code, Section VIII (see § 171.7 of this subchapter).

    Holding time is the time, as determined by testing, that will elapse from loading until the pressure of the contents, under equilibrium conditions, reaches the lowest set pressure of the pressure limiting device(s) (for example, pressure control valve or pressure relief device). Holding time must be determined as specified in § 178.338-9.

    Maximum allowable working pressure (MAWP) means the maximum effective gauge pressure permissible at the top of the shell of a loaded portable tank in its operating position including the highest effective pressure during filling and discharge;

    Minimum design temperature means the temperature which is used for the design and construction of the shell not higher than the lowest (coldest) service temperature of the contents during normal conditions of filling, discharge and transportation.

    Shell means the part of the portable tank which retains the refrigerated liquefied gas intended for transport, including openings and their closures, but does not include service equipment or external structural equipment.

    Tank means a construction which normally consists of either:

    (1) A jacket and one or more inner shells where the space between the shell(s) and the jacket is exhausted of air (vacuum insulation) and may incorporate a thermal insulation system; or

    (2) A jacket and an inner shell with an intermediate layer of solid thermally insulating material (for example, solid foam).

    (b) General design and construction requirements. (1) Portable tanks must be of seamless or welded steel construction and have a water capacity of more than 450 liters (118.9 gallons). Portable tanks must be designed, constructed, certified and stamped in accordance with Section VIII of the ASME Code (see § 171.7 of this subchapter).

    (2 ) Portable tanks must be postweld heat treated and radiographed as prescribed in the ASME Code except that each tank constructed in accordance with part UHT of the ASME Code must be postweld heat treated. Where postweld heat treatment is required, the tank must be treated as a unit after completion of all the welds to the shell and heads. The method must be as prescribed in the ASME Code. Welded attachments to pads may be made after postweld heat treatment is made. The postweld heat treatment must be as prescribed in Section VIII of the ASME Code, but in no event at less than 1050 °F tank metal temperature.

    (3) Welding procedure and welder performance tests must be made annually in accordance with Section IX of the ASME Code (see § 171.7 of this subchapter). In addition to the essential variables named in the ASME Code, the following must be considered as essential variables: number of passes, thickness of plate, heat input per pass, and the specified rod and flux. The number of passes, thickness of plate and heat input per pass may not vary more than 25% from the procedure qualification. Records of the qualification must be retained for at least 5 years by the portable tank manufacturer and made available to the approval agency and the owner of the portable tank as specified in § 178.273.

    (4) Shells and jackets must be made of metallic materials suitable for forming. Jackets must be made of steel. Non-metallic materials may be used for the attachments and supports between the shell and jacket, provided their material properties at the minimum design temperature are proven to be sufficient. In choosing the material, the minimum design temperature must be taken into account with respect to risk of brittle fracture, to hydrogen embrittlement, to stress corrosion cracking and to resistance to impact.

    (5) Any part of a portable tank, including fittings, gaskets and pipe-work, which can be expected normally to come into contact with the refrigerated liquefied gas transported must be compatible with that refrigerated liquefied gas.

    (6) The thermal insulation system must include a complete covering of the shell with effective insulating materials. External insulation must be protected by a jacket so as to prevent the ingress of moisture and other damage under normal transport conditions.

    (7) When a jacket is so closed as to be gas-tight, a device must be provided to prevent any dangerous pressure from developing in the insulation space.

    (8) Materials which may react with oxygen or oxygen enriched atmospheres in a dangerous manner may not be used in portable tanks intended for the transport of refrigerated liquefied gases having a boiling point below minus 182°C at atmospheric pressure in locations with the thermal insulation where there is a risk of contact with oxygen or with oxygen enriched fluid.

    (9) Insulating materials must not deteriorate to an extent that the effectiveness of the insulation system, as determined in accordance with paragraph (b)(11) of this section, would be reduced in service.

    (10) A reference holding time must be determined for each refrigerated Start Printed Page 33451liquefied gas intended for transport in a portable tank. The reference holding time must be determined by testing in accordance with the requirements of § 178.338-9, considering the following factors:

    (i) The effectiveness of the insulation system, determined in accordance with paragraph (b)(11) of this section;

    (ii) The lowest set pressure of the pressure limiting device;

    (iii) The initial filling conditions;

    (iv) An assumed ambient temperature of 30 °C (86 °F);

    (v) The physical properties of the individual refrigerated liquefied gas intended to be transported.

    (11) The effectiveness of the insulation system (heat influx in watts) may be determined by type testing the portable tank in accordance with a procedure specified in § 178.338-9(c) or by using the holding time test in § 178.338-9(b). This test must consist of either:

    (i) A constant pressure test (for example, at atmospheric pressure) when the loss of refrigerated liquefied gas is measured over a period of time; or

    (ii) A closed system test when the rise in pressure in the shell is measured over a period of time.

    (12) When performing the constant pressure test, variations in atmospheric pressure must be taken into account. When performing either test, corrections must be made for any variation of the ambient temperature from the assumed ambient temperature reference value of 30°C (86°F).

    (13) The jacket of a vacuum-insulated double-wall tank must have either an external design pressure not less than 100 kPa (1 bar) gauge pressure calculated in accordance with the ASME Code or a calculated critical collapsing pressure of not less than 200 kPa (2 bar) gauge pressure. Internal and external reinforcements may be included in calculating the ability of the jacket to resist the external pressure.

    Note to Paragraph (b):

    For the determination of the actual holding time, as indicated by paragraphs (b)(10), (11), (12), and (13), before each journey, refer to § 178.338-9(b).

    (c) Design criteria. For shells with vacuum insulation, the test pressure must not be less than 1.3 times the sum of the MAWP and 100 kPa (1 bar). In no case may the test pressure be less than 300 kPa (3 bar) gauge pressure.

    (d) Service equipment. (1) Each filling and discharge opening in portable tanks used for the transport of flammable refrigerated liquefied gases must be fitted with at least three mutually independent shut-off devices in series: the first being a stop-valve situated as close as reasonably practicable to the jacket, the second being a stop-valve and the third being a blank flange or equivalent device. The shut-off device closest to the jacket must be a self-closing device, which is capable of being closed from an accessible position on the portable tank that is remote from the valve within 30 seconds of actuation. This device must actuate at a temperature of not more than 121 °C (250 °F).

    (2) Each filling and discharge opening in portable tanks used for the transport of non-flammable refrigerated liquefied gases must be fitted with at least two mutually independent shut-off devices in series: the first being a stop-valve situated as close as reasonably practicable to the jacket and the second a blank flange or equivalent device.

    (3) For sections of piping which can be closed at both ends and where liquid product can be trapped, a method of automatic pressure relief must be provided to prevent excess pressure build-up within the piping.

    (4) Each filling and discharge opening on a portable tank must be clearly marked to indicate its function.

    (5) When pressure-building units are used, the liquid and vapor connections to that unit must be provided with a valve as close to the jacket as reasonably practicable to prevent the loss of contents in case of damage to the pressure-building unit. A check valve may be used for this purpose if it is located on the vapor side of the pressure build-up coil.

    (6) The materials of construction of valves and accessories must have satisfactory properties at the lowest operating temperature of the portable tank.

    (7) Vacuum insulated portable tanks are not required to have an inspection opening.

    (e) Pressure relief devices. (1) Every shell must be provided with not less than two independent reclosing pressure relief devices. The pressure relief devices must open automatically at a pressure not less than the MAWP and be fully open at a pressure equal to 110% of the MAWP. These devices must, after discharge, close at a pressure not lower than 10% below the pressure at which discharge starts and must remain closed at all lower pressures. The pressure relief devices must be of the type that will resist dynamic forces including surge.

    (2) Except for portable tanks used for oxygen, portable tanks for non-flammable refrigerated liquefied gases (except oxygen) and hydrogen may in addition have frangible discs in parallel with the reclosing devices as specified in paragraphs (e)(4)(ii) and (e)(4)(iii) of this section.

    (3) Pressure relief devices must be designed to prevent the entry of foreign matter, the leakage of gas and the development of any dangerous excess pressure.

    (4) Capacity and setting of pressure relief devices. (i) In the case of the loss of vacuum in a vacuum-insulated tank or of loss of 20% of the insulation of a portable tank insulated with solid materials, the combined capacity of all pressure relief devices installed must be sufficient so that the pressure (including accumulation) inside the shell does not exceed 120% of the MAWP.

    (ii) For non-flammable refrigerated liquefied gases (except oxygen) and hydrogen, this capacity may be achieved by the use of frangible discs in parallel with the required safety-relief devices. Frangible discs must rupture at nominal pressure equal to the test pressure of the shell.

    (iii) Under the circumstances described in paragraphs (e)(4)(i) and (e)(4)(ii) of this section, together with complete fire engulfment, the combined capacity of all pressure relief devices installed must be sufficient to limit the pressure in the shell to the test pressure.

    (iv) The required capacity of the relief devices must be calculated in accordance with CGA Pamphlet S-1.2 (see § 171.7 of this subchapter).

    Start Amendment Part

    75. In § 178.703, the section heading and paragraph (a)(1) introductory text are revised and in paragraph (a)(1)(ii), a new sentence is added at the end of the paragraph to read as follows:

    End Amendment Part
    Marking of IBCs.

    (a) * * *

    (1) Mark every IBC in a durable and clearly visible manner. The marking may be applied in a single line or in multiple lines provided the correct sequence is followed with the information required by this section in letters, numerals and symbols of at least 12 mm in height. This minimum marking size applies only to IBCs manufactured after October 1, 2001). The following information is required in the sequence presented:

    * * * * *

    (ii) * * * The letter “W” must follow the IBC design type identification code on an IBC when the IBC differs from the requirements in subpart N of this part, or is tested using methods other than those specified in this subpart, and is approved by the Associate Administrator in accordance with the provisions in § 178.801(i).

    * * * * *
    Start Printed Page 33452 Start Amendment Part

    76. In § 178.705, the section heading and paragraph (c)(1)(iv)(A) are revised and a new paragraph (c)(1)(iv)(C) is added to read as follows:

    End Amendment Part
    Standards for metal IBCs.
    * * * * *

    (c) * * *

    (1) * * *

    (iv) * * *

    (A) For a reference steel having a product of Rm X Ao = 10,000, where Ao is the minimum elongation (as a percentage) of the reference steel to be used on fracture under tensile stress, (Rm X Ao = 10,000 X 145; if tensile strength is in U.S. Standard units of pounds per square inch) the wall thickness must not be less than:

    Capacity (C) in liters 1Wall thickness (T) in mm
    Types 11A, 11B, 11NTypes 21A, 21B, 21N, 31A, 31B, 31N
    UnprotectedProtectedUnprotected
    C ≤ 10002.01.52.52.0
    1000 < C ≤ 2000T=C/2000 + 1.5T=C/2000 + 1.0T=C/2000 + 2.0T=C/2000 + 1.5
    2000 < C ≤ 3000T=C/2000 + 1.5T=C/2000 + 1.0T=C/1000 + 1.0T=C/2000 + 1.5
    1 Where: gallons = liters X 0.264.
    * * * * *

    (C) For purposes of the calculation described in paragraph (c)(1)(iv)(B) of this section, the guaranteed minimum tensile strength of the metal to be used (Rm1) must be the minimum value according to material standards. However, for austenitic (stainless) steels, the specified minimum value for Rm, according to the material standards, may be increased by up to 15% when a greater value is provided in the material inspection certificate. When no material standard exists for the material in question, the value of Rm must be the minimum value indicated in the material inspection certificate.

    * * * * *
    Start Amendment Part

    77. In § 178.801, in paragraph (i), two sentences are added at the end of the paragraph to read as follows:

    End Amendment Part
    General requirements.
    * * * * *

    (i) * * * A large packaging, as defined in § 171.8 of this subchapter, may be used if approved by the Associate Administrator. The large packaging must conform to the construction standards, performance testing and packaging marking requirements specified in the UN Recommendations.

    * * * * *
    Start Amendment Part

    78. In § 178.812, paragraph (c)(1) is revised and a new paragraph (c)(3) is added to read as follows:

    End Amendment Part
    Top lift test.
    * * * * *

    (c) Test method. (1) A metal or flexible IBC must be lifted in the manner for which it is designed until clear of the floor and maintained in that position for a period of five minutes.

    * * * * *

    (3) If not tested as indicated in paragraph (c)(1) of this section, a flexible IBC design type must be tested as follows:

    (i) Fill the flexible IBC to 95% full with a material representative of the product to be shipped.

    (ii) Suspend the flexible IBC by its lifting devices.

    (iii) Apply a constant downward force through a specially designed platen. The platen will be a minimum of 60% and a maximum of 80% of the cross sectional surface area of the flexible IBC.

    (iv) The combination of the mass of the filled flexible IBC and the force applied through the platen must be a minimum of six times the maximum net mass of the flexible IBC. The test must be conducted for a period of five minutes.

    (v) Other equally effective methods of top lift testing and preparation may be used with approval of the Associate Administrator.

    * * * * *
    Start Part

    PART 179—SPECIFICATIONS FOR TANK CARS

    End Part Start Amendment Part

    79. The authority citation for part 179 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 49 U.S.C. 5105-5127; 49 CFR 1.53.

    End Authority
    [Amended]
    Start Amendment Part

    80. In § 179.102-4, in the introductory text, the wording “vinyl fluoride, inhibited” is revised to read “vinyl fluoride, stabilized”.

    End Amendment Part Start Part

    PART 180—CONTINUING QUALIFICATION AND MAINTENANCE OF PACKAGINGS

    End Part Start Amendment Part

    81. The authority citation for part 180 continues to read as follows:

    End Amendment Part Start Authority

    Authority: 49 U.S.C. 5101-5127; 49 CFR 1.53.

    End Authority Start Amendment Part

    82. Subpart G is added to part 180 to read as follows:

    End Amendment Part
    Subpart G—Qualification and Maintenance of Portable Tanks
    180.601
    Applicability.
    180.603
    Qualification of portable tanks.
    180.605
    Requirements for periodic testing, inspection and repair of portable tanks.

    Subpart G—Qualification and Maintenance of Portable Tanks

    Applicability.

    This subpart prescribes requirements, in addition to those contained in parts 107, 171, 172, 173, and 178 of this subchapter, applicable to any person responsible for the continuing qualification, maintenance or periodic retesting of a portable tank.

    Qualification of portable tanks.

    (a) Each portable tank used for the transportation of hazardous materials must be an authorized packaging.

    (b) To qualify as an authorized packaging, each portable tank must conform to the requirements of this subchapter and the applicable design specification to which the portable tank was constructed.

    (c) The following portable tanks are authorized for use provided they conform to all applicable safety requirements of this subchapter: 51, 56, 57, 60, IM 101, IM 102 and UN portable tanks.

    (d) A portable tank that also meets the definition of “container” in 49 CFR 450.3(a)(3) must conform to the requirements in parts 450 through 453 of this title for compliance with Annex II of the Convention for Safe Containers (CSC).

    (e) Exemption portable tanks based on DOT 51 portable tanks. The owner of a portable tank constructed in accordance with and used under an exemption issued prior to August 31, 1996, which was in conformance with the requirements for Specification DOT 51 portable tanks with the exception of the Start Printed Page 33453location of fill and discharge outlets, shall examine the portable tank and its design to determine if it meets the outlet requirements in effect on October 1, 1996. If the owner determines that the portable tank is in compliance with all requirements of the DOT 51 specification, the exemption number stenciled on the portable tank shall be removed and the specification plate (or a plate placed adjacent to the specification plate) shall be durably marked “DOT 51-E*****” (where ***** is to be replaced by the exemption number). During the period the portable tank is in service, and for one year thereafter, the owner of the portable tank must retain on file, at its principal place of business, a copy of the last exemption in effect.

    Requirements for periodic testing, inspection and repair of portable tanks.

    (a) A portable tank constructed in accordance with a DOT specification for which a test or inspection specified in this subpart has become due, must be tested or inspected prior to being returned for transportation.

    (b) Conditions requiring test and inspection of portable tanks. Without regard to any other test or inspection requirements, a Specification or UN portable tank must be tested and inspected in accordance with this section prior to further use if any of the following conditions exist:

    (1) The portable tank shows evidence of dents, corroded or abraded areas, leakage, or any other condition that might render it unsafe for transportation service.

    (2) The portable tank has been in an accident and has been damaged to an extent that may adversely affect its ability to retain the hazardous material.

    (3) The portable tank has been out of hazardous materials transportation service for a period of one year or more.

    (4) The portable tank has been modified from its original design specification.

    (5) The portable tank is in an unsafe operating condition based on the existence of probable cause.

    (c) Schedule for periodic inspections and tests. Each Specification portable tank must be tested and inspected in accordance with the following schedule:

    (1) Each IM or UN portable tank must be given an initial inspection and test before being placed into service, a periodic inspection and test at least once every 5 years, and an intermediate periodic inspection and test at least every 2.5 years following the initial inspection and the last 5 year periodic inspection and test.

    (2) Each Specification 51 portable tank must be given a periodic inspection and test at least once every five years.

    (3) Each Specification 56 or 57 portable tank must be given a periodic inspection and test at least once every 2.5 years.

    (4) Each Specification 60 portable tank must be given a periodic inspection and test at the end of the first 4-year period after the original test; at least once every 2 years thereafter up to a total of 12 years of service; and at least once annually thereafter. Retesting is not required on a rubber-lined tank except before each relining.

    (d) Intermediate periodic inspection and test. For IM and UN portable tanks the intermediate 2.5 year periodic inspection and test must include at least an internal and external examination of the portable tank and its fittings taking into account the hazardous materials intended to be transported; a leakage test; and a test of the satisfactory operation of all service equipment. Sheathing, thermal insulation, etc. need only be removed to the extent required for reliable appraisal of the condition of the portable tank. For portable tanks intended for the transportation of a single hazardous material, the internal examination may be waived if it is leakage tested in accordance with the procedures in paragraph (i) of this section prior to each filling, or if approved by the Associate Administrator. Portable tanks used for dedicated transportation of refrigerated liquefied gases that are not fitted with inspection openings are excepted from the internal inspection requirement.

    (e) Periodic inspection and test. The 5 year periodic inspection and test must include an internal and external examination and, unless excepted, a pressure test as specified in this section. Sheathing, thermal insulation, etc. need only to be removed to the extent required for reliable appraisal of the condition of the portable tank. Except for DOT Specification 56 and 57 portable tanks, reclosing pressure relief devices must be removed from the tank and tested separately unless they can be tested while installed on the portable tank. For portable tanks where the shell and equipment have been pressure-tested separately, after assembly they must be subjected together to a leakage test and effectively tested and inspected for corrosion. Portable tanks used for the transportation of refrigerated, liquefied gases are excepted from the requirement for internal inspection and the hydraulic pressure test if the portable tanks are pressure tested using an inert gas as prescribed in § 178.338-16(a) and (b) of this subchapter.

    (f) Exceptional inspection and test. The exceptional inspection and test is necessary when a portable tank shows evidence of damaged or corroded areas, or leakage, or other conditions that indicate a deficiency that could affect the integrity of the portable tank. The extent of the exceptional inspection and test must depend on the amount of damage or deterioration of the portable tank. It must include at least the inspection and a pressure test according to paragraph (e) of this section. Pressure relief devices need not be tested or replaced unless there is reason to believe the relief devices have been affected by the damage or deterioration.

    (g) Internal and external examination. The internal and external examinations must ensure that:

    (1) The shell is inspected for pitting, corrosion, or abrasions, dents, distortions, defects in welds or any other conditions, including leakage, that might render the portable tank unsafe for transportation;

    (2) The piping, valves, and gaskets are inspected for corroded areas, defects, and other conditions, including leakage, that might render the portable tank unsafe for filling, discharge or transportation;

    (3) Devices for tightening manhole covers are operative and there is no leakage at manhole covers or gaskets;

    (4) Missing or loose bolts or nuts on any flanged connection or blank flange are replaced or tightened;

    (5) All emergency devices and valves are free from corrosion, distortion and any damage or defect that could prevent their normal operation. Remote closure devices and self-closing stop-valves must be operated to demonstrate proper operation;

    (6) Required markings on the portable tank are legible and in accordance with the applicable requirements; and

    (7) The framework, the supports and the arrangements for lifting the portable tank are in satisfactory condition.

    (h) Pressure test procedures for specification 51, 57, 60, IM or UN portable tanks. (1) Each Specification 57 portable tank must be leak tested by a minimum sustained air pressure of at least 3 psig applied to the entire tank. Each Specification 51 or 56 portable tank must be tested by a minimum pressure (air or hydrostatic) of at least 2 psig or at least one and one-half times the design pressure (maximum allowable working pressure, or re-rated pressure) of the tank, whichever is greater. The leakage test for portable tanks used for refrigerated liquefied gas must be performed at 90% of MAWP. Leakage tests for all other portable tanks must be at a pressure of at least 25% of Start Printed Page 33454MAWP. During each air pressure test, the entire surface of all joints under pressure must be coated with or immersed in a solution of soap and water, heavy oil, or other material suitable for the purpose of detecting leaks. The pressure must be held for a period of time sufficiently long to assure detection of leaks, but in no case less than five minutes. During the air or hydrostatic test, relief devices may be removed, but all the closure fittings must be in place and the relief device openings plugged. Lagging need not be removed from a lagged tank if it is possible to maintain the required test pressure at constant temperature with the tank disconnected from the source of pressure.

    (2) Each Specification 60 portable tank must be retested by completely filling the tank with water or other liquid having a similar viscosity, the temperature of the liquid must not exceed 37.7°C (100°F) during the test, and applying a pressure of 60 psig. The portable tank must be capable of holding the prescribed pressure for at least 10 minutes without leakage, evidence of impending failure, or failure. All closures shall be in place while the test is made and the pressure shall be gauged at the top of the tank. Safety devices and/or vents shall be plugged during this test.

    (3) Each Specification IM or UN portable tank, except for UN portable tanks used for non-refrigerated and refrigerated liquefied gases, and all piping, valves and accessories, except pressure relief devices, must be hydrostatically tested with water, or other liquid of similar density and viscosity, to a pressure not less than 150% of its maximum allowable working pressure. UN portable tanks used for the transportation of non-refrigerated liquefied gases must be hydrostatically tested with water, or other liquid of similar density and viscosity, to a pressure not less than 130% of its maximum allowable working pressure. UN portable tanks used for the transportation of refrigerated liquefied gases may be tested hydrostatically or pneumatically using an inert gas. For pneumatic testing, due regard for protection of all personnel must be taken because of the potential hazard involved in such a test. The pneumatic test pressure in the portable tank must be reached by gradually increasing the pressure to one-half of the test pressure. Thereafter, the test pressure must be increased in steps of approximately one-tenth of the test pressure until the required test pressure has been reached. The pressure must then be reduced to a value equal to four-fifths of the test pressure and held for a sufficient time to permit inspection of the portable tank for leaks. The minimum test pressure for a portable tank is determined on the basis of the hazardous materials that are intended to be transported in the portable tanks. For liquid, solid and non-refrigerated liquefied gases, the minimum test pressure for specific hazardous materials are specified in the applicable T Codes assigned to a particular hazardous material in the § 172.101 Table of this subchapter. While under pressure the tank shall be inspected for leakage, distortion, or any other condition which might render the tank unsafe for service. A portable tank fails to meet the requirements of the pressure test if, during the test, there is permanent distortion of the tank exceeding that permitted by the applicable specification; if there is any leakage; or if there are any deficiencies that would render the portable tank unsafe for transportation. Any portable tank that fails must be rejected and may not be used again for the transportation of a hazardous material unless the tank is adequately repaired, and, thereafter, a successful test is conducted in accordance with the requirements of this paragraph. An approval agency shall witness the hydrostatic or pneumatic test. Any damage or deficiency that might render the portable tank unsafe for service shall be repaired to the satisfaction of the witnessing approval agency. The repaired tank must be retested to the original pressure test requirements. Upon successful completion of the hydrostatic or pneumatic test, as applicable, the witnessing approval agency shall apply its name, identifying mark or identifying number in accordance with paragraph (k) of this section.

    (i) Rejection criteria. When evidence of any unsafe condition is discovered, the portable tank may not be returned to service until it has been repaired and the pressure test is repeated and passed.

    (j) Repair. The repair of a portable tank is authorized, provided such repairs are made in accordance with the requirements prescribed in the specification for the tank's original design and construction. In addition to any other provisions of the specification, no portable tank may be repaired so as to cause leakage or cracks or so as to increase the likelihood of leakage or cracks near areas of stress concentration due to cooling metal shrinkage in welding operations, sharp fillets, reversal of stresses, or otherwise. No field welding may be done except to non-pressure parts. Any cutting, burning or welding operations on the shell of an IM or UN portable tank must be done with the approval of the approval agency and be done in accordance with the requirements of this subchapter, taking into account the pressure vessel code used for the construction of the shell. A pressure test to the original test pressure must be performed after the work is completed.

    (k) Inspection and test markings. Each IM or UN portable tank must be durably and legibly marked, in English, with the date (month and year) of the last pressure test, the identification markings of the approval agency witnessing the test, when required, and the date of the last visual inspection. The marking must be placed on or near the metal identification plate, in letters not less than 3 mm (0.118 inches) high when on the metal identification plate, and 12 mm (0.5 inches) high when on the portable tank.

    (l) Record retention. The owner of each portable tank or his authorized agent shall retain a written record of the date and results of all required inspections and tests, including an ASME manufacturer's date report, if applicable, and the name and address of the person performing the inspection or test, in accordance with the applicable specification. The manufacturer's data report, including a certificate(s) signed by the manufacturer, and the authorized design approval agency, as applicable, indicating compliance with the applicable specification of the portable tank, must be retained in the files of the owner, or his authorized agent, during the time that such portable tank is used for such service, except for Specifications 56 and 57 portable tanks.

    Start Signature

    Issued in Washington, DC, on May 25, 2001, under authority delegated in 49 CFR part 1.

    Edward A. Brigham,

    Acting Deputy Administrator.

    End Signature End Supplemental Information

    BILLING CODE 4910-60-P

    BILLING CODE 14910 60 S

    [FR Doc. 01-13836 Filed 6-14-01; 9:34 am]

    BILLING CODE 4910-60-P

Document Information

Published:
06/21/2001
Department:
Research and Special Programs Administration
Entry Type:
Rule
Action:
Final rule.
Document Number:
01-13836
Pages:
33315-33454 (140 pages)
Docket Numbers:
Docket No. RSPA-2000-7702 (HM-215D)
RINs:
2137-AD41: Harmonization With United Nations Recommendations, International Maritime Dangerous Goods Code, and International Civil Aviation Organization's Technical Instructions
RIN Links:
https://www.federalregister.gov/regulations/2137-AD41/harmonization-with-united-nations-recommendations-international-maritime-dangerous-goods-code-and-in
Topics:
Air carriers, Education, Exports, Hazardous materials transportation, Hazardous waste, Imports, Incorporation by reference, Labeling, Maritime carriers, Motor carriers, Motor vehicle safety, Packaging and containers, Radioactive materials, Railroad safety, Reporting and recordkeeping requirements, Uranium
PDF File:
01-13836.pdf
CFR: (70)
49 CFR 171.7
49 CFR 171.8
49 CFR 171.10
49 CFR 171.11
49 CFR 171.12
More ...