2012-20967. Airworthiness Directives; The Boeing Company Airplanes  

  • Start Preamble

    AGENCY:

    Federal Aviation Administration (FAA), DOT.

    ACTION:

    Notice of proposed rulemaking (NPRM).

    SUMMARY:

    We propose to adopt a new airworthiness directive (AD) for certain The Boeing Company Model 737-600, -700, -800, and -900ER series airplanes. This proposed AD was prompted by incorrect wire support clamps installed within the left environmental cooling systems (ECS) bay, which could allow wiring to come in contact with the exposed metal of the improper clamp. This proposed AD would require inspections to identify the part number of the wire support clamp, related investigative actions, and corrective actions if necessary. We are proposing this AD to prevent electrical arcing and a potential ignition source, which in combination with flammable fuel vapors could result in a fuel tank explosion, and consequent loss of the airplane.

    DATES:

    We must receive comments on this proposed AD by October 11, 2012.

    ADDRESSES:

    You may send comments, using the procedures found in 14 CFR 11.43 and 11.45, by any of the following methods:

    • Federal eRulemaking Portal: Go to http://www.regulations.gov. Follow the instructions for submitting comments.
    • Fax: 202-493-2251.
    • Mail: U.S. Department of Transportation, Docket Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New Jersey Avenue SE., Washington, DC 20590.
    • Hand Delivery: Deliver to Mail address above between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays.

    For service information identified in this proposed AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P.O. Box 3707, MC 2H-65, Seattle, Washington 98124-2207; telephone 206-544-5000, extension 1; fax 206-766-5680; Internet https://www.myboeingfleet.com. You may review copies of the referenced service information at the FAA, Transport Airplane Directorate, 1601 Start Printed Page 51721Lind Avenue SW., Renton, Washington. For information on the availability of this material at the FAA, call 425-227-1221.

    Examining the AD Docket

    You may examine the AD docket on the Internet at http://www.regulations.gov;​; or in person at the Docket Management Facility between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. The AD docket contains this proposed AD, the regulatory evaluation, any comments received, and other information. The street address for the Docket Office (phone: 800-647-5527) is in the ADDRESSES section. Comments will be available in the AD docket shortly after receipt.

    Start Further Info

    FOR FURTHER INFORMATION CONTACT:

    Georgios Roussos, Aerospace Engineer, Systems and Equipment Branch, ANM-130S, FAA, Seattle Aircraft Certification Office, 1601 Lind Avenue SW., Renton, WA 98057-3356; phone: 425-917-6482; fax: 425-917-6590; email: georgios.roussos@faa.gov.

    End Further Info End Preamble Start Supplemental Information

    SUPPLEMENTARY INFORMATION:

    Comments Invited

    We invite you to send any written relevant data, views, or arguments about this proposal. Send your comments to an address listed under the ADDRESSES section. Include “Docket No. FAA-2012-0860; Directorate Identifier 2012-NM-123-AD” at the beginning of your comments. We specifically invite comments on the overall regulatory, economic, environmental, and energy aspects of this proposed AD. We will consider all comments received by the closing date and may amend this proposed AD because of those comments.

    We will post all comments we receive, without change, to http://www.regulations.gov,, including any personal information you provide. We will also post a report summarizing each substantive verbal contact we receive about this proposed AD.

    Discussion

    We reviewed reports of incorrect wire support clamps installed within the left ECS bay, which is a flammable leakage zone. Use of incorrect wire support clamps that are not fully cushioned could allow electrical power wiring to come in contact with the exposed metal of the improper clamp. Power wiring shorts to the exposed metal of the wire support clamp could produce electrical arcing. We are proposing this AD to prevent electrical arcing and a potential ignition source, which in combination with flammable fuel vapors, could result in a fuel tank explosion, and consequent loss of the airplane.

    Relevant Service Information

    We reviewed Boeing Special Attention Service Bulletin 737-28-1303, dated April 26, 2012. The service information describes procedures for a detailed inspection of certain wire support clamps to identify part number TA0930034-10 wire support clamp and related investigative actions to verify that the flange cushions completely surround the two metal strap sections of the wire support clamp and to detect any possible chafing of the wire bundle within the left side ECS bay, and corrective actions if necessary. Corrective actions include replacing the discrepant clamp with a new or serviceable TA0930034-10 wire support clamp if the part number is incorrect or if the flange cushions do not completely surround the two metal strap sections of the wire support clamp, and repairing or replacing chafed wiring.

    FAA's Determination

    We are proposing this AD because we evaluated all the relevant information and determined the unsafe condition described previously is likely to exist or develop in other products of these same type designs.

    Proposed AD Requirements

    This proposed AD would require accomplishing the actions specified in the service information described previously.

    Costs of Compliance

    We estimate that this proposed AD affects 297 airplanes of U.S. registry.

    We estimate the following costs to comply with this proposed AD:

    Estimated Costs

    ActionLabor costParts costCost per productNumber of airplanesCost on U.S. operators
    Inspection Group 1 airplanes10 work-hours × $85 per hour = $850$0$850185$157,250
    Inspection Group 2 airplanes2 work-hours × $85 per hour = $170017011219,040

    We estimate the following costs to do any necessary replacements that would be required based on the results of the proposed inspection. We have no way of determining the number of aircraft that might need these replacements.

    On-Condition Costs

    ActionLabor costParts costCost per product
    Replacement of wire support clamp1 work-hour × $85 per hour = $85$3$88

    According to the manufacturer, some of the costs of this proposed AD may be covered under warranty, thereby reducing the cost impact on affected individuals. We do not control warranty coverage for affected individuals. As a result, we have included all costs in our cost estimate.

    We have received no definitive data that would enable us to provide cost estimates for the on-condition repair of chafed or damaged wiring specified in this proposed AD.

    Authority for This Rulemaking

    Title 49 of the United States Code specifies the FAA's authority to issue rules on aviation safety. Subtitle I, section 106, describes the authority of the FAA Administrator. Subtitle VII: Aviation Programs, describes in more detail the scope of the Agency's authority.

    We are issuing this rulemaking under the authority described in Subtitle VII, Part A, Subpart III, Section 44701: Start Printed Page 51722“General requirements.” Under that section, Congress charges the FAA with promoting safe flight of civil aircraft in air commerce by prescribing regulations for practices, methods, and procedures the Administrator finds necessary for safety in air commerce. This regulation is within the scope of that authority because it addresses an unsafe condition that is likely to exist or develop on products identified in this rulemaking action.

    Regulatory Findings

    We determined that this proposed AD would not have federalism implications under Executive Order 13132. This proposed AD would not have a substantial direct effect on the States, on the relationship between the national Government and the States, or on the distribution of power and responsibilities among the various levels of government.

    For the reasons discussed above, I certify this proposed regulation:

    (1) Is not a “significant regulatory action” under Executive Order 12866,

    (2) Is not a “significant rule” under the DOT Regulatory Policies and Procedures (44 FR 11034, February 26, 1979),

    (3) Will not affect intrastate aviation in Alaska, and

    (4) Will not have a significant economic impact, positive or negative, on a substantial number of small entities under the criteria of the Regulatory Flexibility Act.

    Start List of Subjects

    List of Subjects in 14 CFR Part 39

    • Air transportation
    • Aircraft
    • Aviation safety
    • Incorporation by reference
    • Safety
    End List of Subjects

    The Proposed Amendment

    Accordingly, under the authority delegated to me by the Administrator, the FAA proposes to amend 14 CFR part 39 as follows:

    Start Part

    PART 39—AIRWORTHINESS DIRECTIVES

    1. The authority citation for part 39 continues to read as follows:

    Start Authority

    Authority: 49 U.S.C. 106(g), 40113, 44701.

    End Authority
    [Amended]

    2. The FAA amends § 39.13 by adding the following new airworthiness directive (AD):

    The Boeing Company: Docket No. FAA-2012-0860; Directorate Identifier 2012-NM-123-AD.

    (a) Comments Due Date

    We must receive comments by October 11, 2012.

    (b) Affected ADs

    None.

    (c) Applicability

    This AD applies to The Boeing Company Model 737-600, -700, -800, and -900ER series airplanes; certificated in any category; as identified in Boeing Special Attention Service Bulletin 737-28-1303, dated April 26, 2012.

    (d) Subject

    Joint Aircraft System Component (JASC)/Air Transport Association (ATA) of America Code 28, Fuel System.

    (e) Unsafe Condition

    This AD was prompted by incorrect wire support clamps installed within the left environmental cooling systems (ECS) bay, which could allow wiring to come in contact with the exposed metal of the improper clamp. We are issuing this AD to prevent electrical arcing and a potential ignition source, which in combination with flammable fuel vapors could result in a fuel tank explosion, and consequent loss of the airplane.

    (f) Compliance

    Comply with this AD within the compliance times specified, unless already done.

    (g) Inspection and Corrective Actions

    Within 60 months after the effective date of this AD, do a detailed inspection for part number TA0930034-10 wire support clamp, and do all applicable related investigative and corrective actions, in accordance with the Accomplishment Instructions of Boeing Special Attention Service Bulletin 737-28-1303, dated April 26, 2012. Do all applicable related investigative and corrective actions before further flight.

    (h) Parts Installation Prohibition

    As of the effective date of this AD, no person may install a wire support clamp that is not part number (P/N) TA0930034-10 within the left ECS bay of any airplane.

    (i) Alternative Methods of Compliance (AMOCs)

    (1) The Manager, Seattle Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in the Related Information section of this AD. Information may be emailed to: 9-ANM-Seattle-ACO-AMOC-Requests@faa.gov.

    (2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office.

    (j) Related Information

    (1) For more information about this AD, contact Georgios Roussos, Aerospace Engineer, Systems and Equipment Branch, ANM-130S, FAA, Seattle Aircraft Certification Office, 1601 Lind Avenue SW., Renton, WA 98057-3356; phone: 425-917-6482; fax: 425-917-6590; email: georgios.roussos@faa.gov.

    (2) For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P. O. Box 3707, MC 2H-65, Seattle, Washington 98124-2207; telephone 206-544-5000, extension 1; fax 206-766-5680; Internet https://www.myboeingfleet.com. You may review copies of the referenced service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, Washington. For information on the availability of this material at the FAA, call 425-227-1221.

    Start Signature

    Issued in Renton, Washington, on August 17, 2012.

    Ali Bahrami,

    Manager, Transport Airplane Directorate, Aircraft Certification Service.

    End Signature End Part End Supplemental Information

    [FR Doc. 2012-20967 Filed 8-24-12; 8:45 am]

    BILLING CODE 4910-13-P

Document Information

Comments Received:
0 Comments
Published:
08/27/2012
Department:
Federal Aviation Administration
Entry Type:
Proposed Rule
Action:
Notice of proposed rulemaking (NPRM).
Document Number:
2012-20967
Dates:
We must receive comments on this proposed AD by October 11, 2012.
Pages:
51720-51722 (3 pages)
Docket Numbers:
Docket No. FAA-2012-0860, Directorate Identifier 2012-NM-123-AD
RINs:
2120-AA64: Airworthiness Directives
RIN Links:
https://www.federalregister.gov/regulations/2120-AA64/airworthiness-directives
Topics:
Air transportation, Aircraft, Aviation safety, Incorporation by reference, Safety
PDF File:
2012-20967.pdf
Supporting Documents:
» U.S. DOT/FAA - See Attachment
» U.S. DOT/FAA - See Attachments
CFR: (1)
14 CFR 39.13