Code of Federal Regulations (Last Updated: November 8, 2024) |
Title 10 - Energy |
Chapter II—Department of Energy |
SubChapter D—Energy Conservation |
Part 430 - Energy Conservation Program for Consumer Products |
Subpart B - Test Procedures |
Appendix J2 to Subpart B of Part 430 - —Uniform Test Method for Measuring the Energy Consumption of Automatic and Semi-automatic Clothes Washers
-
Appendix J2 to Subpart B of Part 430 - Uniform Test Method for Measuring the Energy Consumption of Automatic and Semi-automatic Clothes Washers
Note:Manufacturers must use the results of testing under this appendix to determine compliance with the relevant standards for clothes washers from § 430.32(g)(4) and from § 431.156(b) as they appeared in January 1, 2022 edition of 10 CFR parts 200-499. Specifically, before November 28, 2022 representations must be based upon results generated either under this appendix as codified on July 1, 2022 or under this appendix as it appeared in the 10 CFR parts 200-499 edition revised as of January 1, 2022. Any representations made on or after November 28, 2022 but before the compliance date of any amended standards for clothes washers must be made based upon results generated using this appendix as codified on July 1, 2022. Manufacturers must use the results of testing under Appendix J to determine compliance with any amended standards for clothes washers provided in 10 CFR 430.32(g) and in § 431.156 that are published after January 1, 2022. Any representations related to energy or water consumption of residential or commercial clothes washers must be made in accordance with the appropriate appendix that applies (i.e., Appendix J or this appendix) when determining compliance with the relevant standard. Manufacturers may also use Appendix J to certify compliance with any amended standards prior to the applicable compliance date for those standards.
0. Incorporation by Reference
DOE incorporated by reference in § 430.3, the entire test standard for IEC 62301. However, only enumerated provisions of this standard are applicable to this appendix, as follows. In cases in which there is a conflict, the language of the test procedure in this appendix takes precedence over the referenced test standard.
0.1 IEC 62301:
(a) Section 4.2 as referenced in section 2.4 of this appendix;
(b) Section 4.3.2 as referenced in section 2.1.2 of this appendix;
(c) Section 4.4 as referenced in section 2.5.3 of this appendix;
(d) Section 5.1 as referenced in section 3.9.2 of this appendix;
(e) Section 5.2 as referenced in section 2.10 of this appendix; and
(f) Section 5.3.2 as referenced in section 3.9.3 of this appendix.
0.2 [Reserved]
1. Definitions
Active mode means a mode in which the clothes washer is connected to a mains power source, has been activated, and is performing one or more of the main functions of washing, soaking, tumbling, agitating, rinsing, and/or removing water from the clothing, or is involved in functions necessary for these main functions, such as admitting water into the washer or pumping water out of the washer. Active mode also includes delay start and cycle finished modes.
Active washing mode means a mode in which the clothes washer is performing any of the operations included in a complete cycle intended for washing a clothing load, including the main functions of washing, soaking, tumbling, agitating, rinsing, and/or removing water from the clothing.
Adaptive water fill control system means a clothes washer automatic water fill control system that is capable of automatically adjusting the water fill level based on the size or weight of the clothes load placed in the clothes container.
Automatic water fill control system means a clothes washer water fill control system that does not allow or require the user to determine or select the water fill level, and includes adaptive water fill control systems and fixed water fill control systems.
Bone-dry means a condition of a load of test cloth that has been dried in a dryer at maximum temperature for a minimum of 10 minutes, removed and weighed before cool down, and then dried again for 10 minute periods until the final weight change of the load is 1 percent or less.
Clothes container means the compartment within the clothes washer that holds the clothes during the operation of the machine.
Cold rinse means the coldest rinse temperature available on the machine, as indicated to the user on the clothes washer control panel.
Combined low-power mode means the aggregate of available modes other than active washing mode, including inactive mode, off mode, delay start mode, and cycle finished mode.
Cycle finished mode means an active mode that provides continuous status display, intermittent tumbling, or air circulation following operation in active washing mode.
Delay start mode means an active mode in which activation of active washing mode is facilitated by a timer.
Energy test cycle means the complete set of wash/rinse temperature selections required for testing, as determined according to section 2.12 of this appendix.
Fixed water fill control system means a clothes washer automatic water fill control system that automatically terminates the fill when the water reaches a pre-defined level that is not based on the size or weight of the clothes load placed in the clothes container, without allowing or requiring the user to determine or select the water fill level.
Inactive mode means a standby mode that facilitates the activation of active mode by remote switch (including remote control), internal sensor, or timer, or that provides continuous status display.
Integrated modified energy factor means the quotient of the cubic foot (or liter) capacity of the clothes container divided by the total clothes washer energy consumption per cycle, with such energy consumption expressed as the sum of:
(a) The machine electrical energy consumption;
(b) The hot water energy consumption;
(c) The energy required for removal of the remaining moisture in the wash load; and
(d) The combined low-power mode energy consumption.
Integrated water factor means the quotient of the total weighted per-cycle water consumption for all wash cycles in gallons divided by the cubic foot (or liter) capacity of the clothes washer.
Load usage factor means the percentage of the total number of wash loads that a user would wash a particular size (weight) load.
Lot means a quantity of cloth that has been manufactured with the same batches of cotton and polyester during one continuous process.
Manual water fill control system means a clothes washer water fill control system that requires the user to determine or select the water fill level.
Modified energy factor means the quotient of the cubic foot (or liter) capacity of the clothes container divided by the total clothes washer energy consumption per cycle, with such energy consumption expressed as the sum of the machine electrical energy consumption, the hot water energy consumption, and the energy required for removal of the remaining moisture in the wash load.
Non-water-heating clothes washer means a clothes washer that does not have an internal water heating device to generate hot water.
Normal cycle means the cycle recommended by the manufacturer (considering manufacturer instructions, control panel labeling, and other markings on the clothes washer) for normal, regular, or typical use for washing up to a full load of normally soiled cotton clothing. For machines where multiple cycle settings are recommended by the manufacturer for normal, regular, or typical use for washing up to a full load of normally soiled cotton clothing, then the Normal cycle is the cycle selection that results in the lowest IMEF or MEFJ2 value.
Off mode means a mode in which the clothes washer is connected to a mains power source and is not providing any active or standby mode function, and where the mode may persist for an indefinite time.
Standby mode means any mode in which the clothes washer is connected to a mains power source and offers one or more of the following user oriented or protective functions that may persist for an indefinite time:
(a) Facilitating the activation of other modes (including activation or deactivation of active mode) by remote switch (including remote control), internal sensor, or timer;
(b) Continuous functions, including information or status displays (including clocks) or sensor-based functions.
(c) A timer is a continuous clock function (which may or may not be associated with a display) that provides regular scheduled tasks (e.g., switching) and that operates on a continuous basis.
Temperature use factor means, for a particular wash/rinse temperature setting, the percentage of the total number of wash loads that an average user would wash with that setting.
User-adjustable adaptive water fill control system means a clothes washer fill control system that allows the user to adjust the amount of water that the machine provides, which is based on the size or weight of the clothes load placed in the clothes container.
Wash time means the wash portion of active washing mode, which begins when the cycle is initiated and includes the agitation or tumble time, which may be periodic or continuous during the wash portion of active washing mode.
Water factor means the quotient of the total weighted per-cycle water consumption for cold wash divided by the cubic foot (or liter) capacity of the clothes washer.
Water-heating clothes washer means a clothes washer where some or all of the hot water for clothes washing is generated by a water heating device internal to the clothes washer.
2. Testing Conditions and Instrumentation
2.1 Electrical energy supply.
2.1.1 Supply voltage and frequency. Maintain the electrical supply at the clothes washer terminal block within 2 percent of 120, 120/240, or 120/208Y volts as applicable to the particular terminal block wiring system and within 2 percent of the nameplate frequency as specified by the manufacturer. If the clothes washer has a dual voltage conversion capability, conduct test at the highest voltage specified by the manufacturer.
2.1.2 Supply voltage waveform. For the combined low-power mode testing, maintain the electrical supply voltage waveform indicated in Section 4, Paragraph 4.3.2 of IEC 62301. If the power measuring instrument used for testing is unable to measure and record the total harmonic content during the test measurement period, total harmonic content may be measured and recorded immediately before and after the test measurement period.
2.2 Supply water. Maintain the temperature of the hot water supply at the water inlets between 130 °F (54.4 °C) and 135 °F (57.2 °C), targeting the midpoint of the range. Maintain the temperature of the cold water supply at the water inlets between 55 °F (12.8 °C) and 60 °F (15.6 °C), targeting the midpoint of the range.
2.3 Water pressure. Maintain the static water pressure at the hot and cold water inlet connection of the clothes washer at 35 pounds per square inch gauge (psig) ± 2.5 psig (241.3 kPa ± 17.2 kPa) when the water is flowing.
2.4 Test room temperature. For all clothes washers, maintain the test room ambient air temperature at 75 ± 5 °F (23.9 ± 2.8 °C) for active mode testing and combined low-power mode testing. Do not use the test room ambient air temperature conditions specified in Section 4, Paragraph 4.2 of IEC 62301 for combined low-power mode testing.
2.5 Instrumentation. Perform all test measurements using the following instruments, as appropriate:
2.5.1 Weighing scales.
2.5.1.1 Weighing scale for test cloth. The scale used for weighing test cloth must have a resolution of no larger than 0.2 oz (5.7 g) and a maximum error no greater than 0.3 percent of the measured value.
2.5.1.2 Weighing scale for clothes container capacity measurement. The scale used for performing the clothes container capacity measurement must have a resolution no larger than 0.50 lbs (0.23 kg) and a maximum error no greater than 0.5 percent of the measured value.
2.5.2 Watt-hour meter. The watt-hour meter used to measure electrical energy consumption must have a resolution no larger than 1 Wh (3.6 kJ) and a maximum error no greater than 2 percent of the measured value for any demand greater than 50 Wh (180.0 kJ).
2.5.3 Watt meter. The watt meter used to measure combined low-power mode power consumption must comply with the requirements specified in Section 4, Paragraph 4.4 of IEC 62301 (incorporated by reference, see § 430.3). If the power measuring instrument used for testing is unable to measure and record the crest factor, power factor, or maximum current ratio during the test measurement period, the crest factor, power factor, and maximum current ratio may be measured and recorded immediately before and after the test measurement period.
2.5.4 Water and air temperature measuring devices. The temperature devices used to measure water and air temperature must have an error no greater than ±1 °F (±0.6 °C) over the range being measured.
2.5.4.1 Non-reversible temperature indicator labels, adhered to the inside of the clothes container, may be used to confirm that an extra-hot wash temperature greater than 135 °F has been achieved during the wash cycle, under the following conditions. The label must remain waterproof, intact, and adhered to the wash drum throughout an entire wash cycle; provide consistent maximum temperature readings; and provide repeatable temperature indications sufficient to demonstrate that a wash temperature of greater than 135 °F has been achieved. The label must have been verified to consistently indicate temperature measurements with an accuracy of ±1 °F if the label provides a temperature indicator at 135 °F. If the label does not provide a temperature indicator at 135 °F, the label must have been verified to consistently indicate temperature measurements with an accuracy of ±1 °F if the next-highest temperature indicator is greater than 135 °F and less than 140 °F, or ±3 °F if the next-highest temperature indicator is 140 °F or greater. If the label does not provide a temperature indicator at 135 °F, failure to activate the next-highest temperature indicator does not necessarily indicate the lack of an extra-hot wash temperature. However, such a result would not be conclusive due to the lack of verification of the water temperature requirement, in which case an alternative method must be used to confirm that an extra-hot wash temperature greater than 135 °F has been achieved during the wash cycle. If using a temperature indicator label to test a front-loading clothes washer, adhere the label along the interior surface of the clothes container drum, midway between the front and the back of the drum, adjacent to one of the baffles. If using a temperature indicator label to test a top-loading clothes washer, adhere the label along the interior surface of the clothes container drum, on the vertical portion of the sidewall, as close to the bottom of the container as possible.
2.5.4.2 Submersible temperature loggers placed inside the wash drum may be used to confirm that an extra-hot wash temperature greater than 135 °F has been achieved during the wash cycle, under the following conditions. The submersible temperature logger must have a time resolution of at least 1 data point every 5 seconds and a temperature measurement accuracy of ±1 °F. Due to the potential for a waterproof capsule to provide a thermal insulating effect, failure to measure a temperature of 135 °F does not necessarily indicate the lack of an extra-hot wash temperature. However, such a result would not be conclusive due to the lack of verification of the water temperature requirement, in which case an alternative method must be used to confirm that an extra-hot wash temperature greater than 135 °F has been achieved during the wash cycle.
2.5.5 Water meter. A water meter must be installed in both the hot and cold water lines to measure water flow and/or water consumption. The water meters must have a resolution no larger than 0.1 gallons (0.4 liters) and a maximum error no greater than 2 percent for the water flow rates being measured. If the volume of hot water for any individual cycle within the energy test cycle is less than 0.1 gallons (0.4 liters), the hot water meter must have a resolution no larger than 0.01 gallons (0.04 liters).
2.5.6 Water pressure gauge. A water pressure gauge must be installed in both the hot and cold water lines to measure water pressure. The water pressure gauges must have a resolution of 1 pound per square inch gauge (psig) (6.9 kPa) and a maximum error no greater than 5 percent of any measured value.
2.6 Bone dryer temperature. The dryer used for bone drying must heat the test cloth load above 210 °F (99 °C).
2.7 Test cloths. The test cloth material and dimensions must conform to the specifications in appendix J3 to this subpart. The energy test cloth and the energy stuffer cloths must be clean and must not be used for more than 60 test runs (after preconditioning as specified in section 5 of appendix J3 to this subpart). All energy test cloth must be permanently marked identifying the lot number of the material. Mixed lots of material must not be used for testing a clothes washer. The moisture absorption and retention must be evaluated for each new lot of test cloth using the standard extractor Remaining Moisture Content (RMC) procedure specified in appendix J3 to this subpart.
2.8 Test load sizes. Use Table 5.1 of this appendix to determine the maximum, minimum, and, when required, average test load sizes based on the clothes container capacity as measured in section 3.1 of this appendix. Test loads must consist of energy test cloths and no more than five energy stuffer cloths per load to achieve the proper weight.
Use the test load sizes and corresponding water fill settings defined in Table 2.8 of this appendix when measuring water and energy consumption. Use only the maximum test load size when measuring RMC.
Table 2.8 - Required Test Load Sizes and Water Fill Settings
Water fill control system type Test load size Water fill setting Manual water fill control system Max
MinMax.
Min.Automatic water fill control system Max
Avg
MinAs determined by the clothes washer. 2.9 Use of test loads.
2.9.1 Test loads for energy and water consumption measurements must be bone dry prior to the first cycle of the test, and dried to a maximum of 104 percent of bone dry weight for subsequent testing.
2.9.2 Prepare the energy test cloths for loading by grasping them in the center, lifting, and shaking them to hang loosely, as illustrated in Figure 2.9.2 of this appendix.
For all clothes washers, follow any manufacturer loading instructions provided to the user regarding the placement of clothing within the clothes container. In the absence of any manufacturer instructions regarding the placement of clothing within the clothes container, the following loading instructions apply.
2.9.2.1 To load the energy test cloths in a top-loading clothes washer, arrange the cloths circumferentially around the axis of rotation of the clothes container, using alternating lengthwise orientations for adjacent pieces of cloth. Complete each cloth layer across its horizontal plane within the clothes container before adding a new layer. Figure 2.9.2.1 of this appendix illustrates the correct loading technique for a vertical-axis clothes washer.
2.9.2.2 To load the energy test cloths in a front-loading clothes washer, grasp each test cloth in the center as indicted in section 2.9.2 of this appendix, and then place each cloth into the clothes container prior to activating the clothes washer.
2.10 Clothes washer installation. Install the clothes washer in accordance with manufacturer's instructions. For combined low-power mode testing, install the clothes washer in accordance with Section 5, Paragraph 5.2 of IEC 62301 (incorporated by reference; see § 430.3), disregarding the provisions regarding batteries and the determination, classification, and testing of relevant modes.
2.11 Clothes washer pre-conditioning.
2.11.1 Non-water-heating clothes washer. If the clothes washer has not been filled with water in the preceding 96 hours, pre-condition it by running it through a cold rinse cycle and then draining it to ensure that the hose, pump, and sump are filled with water.
2.11.2 Water-heating clothes washer. If the clothes washer has not been filled with water in the preceding 96 hours, or if it has not been in the test room at the specified ambient conditions for 8 hours, pre-condition it by running it through a cold rinse cycle and then draining it to ensure that the hose, pump, and sump are filled with water.
2.12 Determining the energy test cycle. To determine the energy test cycle, evaluate the wash/rinse temperature selection flowcharts in the order in which they are presented in this section. Except for Cold Wash/Cold Rinse, use the maximum load size to evaluate each flowchart. The determination of the energy test cycle must take into consideration all cycle settings available to the end user, including any cycle selections or cycle modifications provided by the manufacturer via software or firmware updates to the product, for the basic model under test. The energy test cycle does not include any cycle that is recommended by the manufacturer exclusively for cleaning, deodorizing, or sanitizing the clothes washer.
3. Test Measurements
3.1 Clothes container capacity. Measure the entire volume that a clothes load could occupy within the clothes container during active mode washer operation according to the following procedures:
3.1.1 Place the clothes washer in such a position that the uppermost edge of the clothes container opening is leveled horizontally, so that the container will hold the maximum amount of water. For front-loading clothes washers, the door seal and shipping bolts or other forms of bracing hardware to support the wash drum during shipping must remain in place during the capacity measurement.
If the design of a front-loading clothes washer does not include shipping bolts or other forms of bracing hardware to support the wash drum during shipping, a laboratory may support the wash drum by other means, including temporary bracing or support beams. Any temporary bracing or support beams must keep the wash drum in a fixed position, relative to the geometry of the door and door seal components, that is representative of the position of the wash drum during normal operation. The method used must avoid damage to the unit that would affect the results of the energy and water testing.
For a front-loading clothes washer that does not include shipping bolts or other forms of bracing hardware to support the wash drum during shipping, the laboratory must fully document the alternative method used to support the wash drum during capacity measurement, include such documentation in the final test report, and pursuant to § 429.71 of this chapter, the manufacturer must retain such documentation as part its test records.
3.1.2 Line the inside of the clothes container with a 2 mil thickness (0.051 mm) plastic bag. All clothes washer components that occupy space within the clothes container and that are recommended for use during a wash cycle must be in place and must be lined with a 2 mil thickness (0.051 mm) plastic bag to prevent water from entering any void space.
3.1.3 Record the total weight of the machine before adding water.
3.1.4 Fill the clothes container manually with either 60 °F ± 5 °F (15.6 °C ± 2.8 °C) or 100 °F ± 10 °F (37.8 °C ± 5.5 °C) water, with the door open. For a top-loading vertical-axis clothes washer, fill the clothes container to the uppermost edge of the rotating portion, including any balance ring. Figure 3.1.4.1 of this appendix illustrates the maximum fill level for top-loading clothes washers.
For a front-loading horizontal-axis clothes washer, fill the clothes container to the highest point of contact between the door and the door gasket. If any portion of the door or gasket would occupy the measured volume space when the door is closed, exclude from the measurement the volume that the door or gasket portion would occupy. For a front-loading horizontal-axis clothes washer with a concave door shape, include any additional volume above the plane defined by the highest point of contact between the door and the door gasket, if that area can be occupied by clothing during washer operation. For a top-loading horizontal-axis clothes washer, include any additional volume above the plane of the door hinge that clothing could occupy during washer operation. Figure 3.1.4.2 of this appendix illustrates the maximum fill volumes for all horizontal-axis clothes washer types.
For all clothes washers, exclude any volume that cannot be occupied by the clothing load during operation.
3.1.5 Measure and record the weight of water, W, in pounds.
3.1.6 Calculate the clothes container capacity as follows:
C = W/d
where:
C = Capacity in cubic feet (liters).
W = Mass of water in pounds (kilograms).
d = Density of water (62.0 lbs/ft3 for 100 °F (993 kg/m3 for 37.8 °C) or 62.3 lbs/ft3 for 60 °F (998 kg/m3 for 15.6 °C)).
3.1.7 Calculate the clothes container capacity, C, to the nearest 0.01 cubic foot for the purpose of determining test load sizes per Table 5.1 of this appendix and for all subsequent calculations that include the clothes container capacity.
3.2 Procedure for measuring water and energy consumption values on all automatic and semi-automatic washers.
3.2.1 Perform all energy consumption tests under the energy test cycle.
3.2.2 Perform the test sections listed in Table 3.2.2 in accordance with the wash/rinse temperature selections available in the energy test cycle.
Table 3.2.2 - Test Section Reference
Wash/rinse temperature
selections available in the
energy test cycleCorresponding test section
referenceExtra-Hot/Cold 3.3 Hot/Cold 3.4 Warm/Cold 3.5 Warm/Warm 3.6 Cold/Cold 3.7 Test Sections Applicable to all Clothes Washers Remaining Moisture Content 3.8 Combined Low-Power Mode Power 3.9 3.2.3 Hot and cold water faucets.
3.2.3.1 For automatic clothes washers, open both the hot and cold water faucets.
3.2.3.2 For semi-automatic washers:
(1) For hot inlet water temperature, open the hot water faucet completely and close the cold water faucet;
(2) For warm inlet water temperature, open both hot and cold water faucets completely;
(3) For cold inlet water temperature, close the hot water faucet and open the cold water faucet completely.
3.2.4 Wash/rinse temperature selection. Set the wash/rinse temperature selection control to obtain the desired wash/rinse temperature selection within the energy test cycle.
3.2.5 Wash time setting.
3.2.5.1 If the cycle under test offers a range of wash time settings, the wash time setting shall be the higher of either the minimum or 70 percent of the maximum wash time available for the wash cycle under test, regardless of the labeling of suggested dial locations. If 70 percent of the maximum wash time is not available on a dial with a discrete number of wash time settings, choose the next-highest setting greater than 70 percent.
3.2.5.2 If the clothes washer is equipped with an electromechanical dial or timer controlling wash time that rotates in both directions, reset the dial to the minimum wash time and then turn it in the direction of increasing wash time to reach the appropriate setting. If the appropriate setting is passed, return the dial to the minimum wash time and then turn in the direction of increasing wash time until the appropriate setting is reached.
3.2.6 Water fill levels.
3.2.6.1 Clothes washers with manual water fill control system. Set the water fill selector to the maximum water level available for the wash cycle under test for the maximum test load size and the minimum water level available for the wash cycle under test for the minimum test load size.
3.2.6.2 Clothes washers with automatic water fill control system.
3.2.6.2.1 Not user adjustable. The maximum, minimum, and average water levels as described in the following sections refer to the amount of water fill that is automatically selected by the control system when the respective test loads are used.
3.2.6.2.2 User-adjustable adaptive. Conduct four tests on clothes washers with user-adjustable adaptive water fill controls. Conduct the first test using the maximum test load and with the adaptive water fill control system set in the setting that uses the most water. Conduct the second test using the minimum test load and with the adaptive water fill control system set in the setting that uses the least water. Conduct the third test using the average test load and with the adaptive water fill control system set in the setting that uses the most water. Conduct the fourth test using the average test load and with the adaptive water fill control system set in the setting that uses the least water. Average the results of the third and fourth tests to obtain the energy and water consumption values for the average test load size.
3.2.6.3 Clothes washers with automatic water fill control system and alternate manual water fill control system. If a clothes washer with an automatic water fill control system allows user selection of manual controls as an alternative, test both manual and automatic modes and, for each mode, calculate the energy consumption (HET, MET, and DE) and water consumption (QT) values as set forth in section 4 of this appendix. Then, calculate the average of the two values (one from each mode, automatic and manual) for each variable (HET, MET, DE, and QT) and use the average value for each variable in the final calculations in section 4 of this appendix.
3.2.7 Manufacturer default settings. For clothes washers with electronic control systems, use the manufacturer default settings for any cycle selections, except for
(1) the temperature selection,
(2) the wash water fill levels,
(3) if necessary, the spin speeds on wash cycles used to determine remaining moisture content, or
(4) network settings. If the clothes washer has network capabilities, the network settings must be disabled throughout testing if such settings can be disabled by the end-user and the product's user manual provides instructions on how to do so. For all other cycle selections, the manufacturer default settings must be used for wash conditions such as agitation/tumble operation, soil level, spin speed on wash cycles used to determine energy and water consumption, wash times, rinse times, optional rinse settings, water heating time for water heating clothes washers, and all other wash parameters or optional features applicable to that wash cycle. Any optional wash cycle feature or setting (other than wash/rinse temperature, water fill level selection, spin speed on wash cycles used to determine remaining moisture content, or network settings on clothes washers with network capabilities) that is activated by default on the wash cycle under test must be included for testing unless the manufacturer instructions recommend not selecting this option, or recommend selecting a different option, for washing normally soiled cotton clothing. For clothes washers with control panels containing mechanical switches or dials, any optional settings, except for (1) the temperature selection, (2) the wash water fill levels, or (3) if necessary, the spin speeds on wash cycles used to determine remaining moisture content, must be in the position recommended by the manufacturer for washing normally soiled cotton clothing. If the manufacturer instructions do not recommend a particular switch or dial position to be used for washing normally soiled cotton clothing, the setting switch or dial must remain in its as-shipped position.
3.2.8 For each wash cycle tested, include the entire active washing mode and exclude any delay start or cycle finished modes.
3.2.9 Anomalous Test Cycles. If during a wash cycle the clothes washer: (a) Signals to the user by means of a visual or audio alert that an out-of-balance condition has been detected; or (b) terminates prematurely and thus does not include the agitation/tumble operation, spin speed(s), wash times, and rinse times applicable to the wash cycle under test, discard the test data and repeat the wash cycle. Document in the test report the rejection of data from any wash cycle during testing and the reason for the rejection.
3.3 Extra-Hot Wash/Cold Rinse. Measure the water and electrical energy consumption for each water fill level and test load size as specified in sections 3.3.1 through 3.3.3 of this appendix for the Extra-Hot Wash/Cold Rinse as defined within the energy test cycle.
3.3.1 Maximum test load and water fill. Measure the values for hot water consumption (HmX), cold water consumption (CmX), and electrical energy consumption (EmX) for an Extra-Hot Wash/Cold Rinse cycle, with the controls set for the maximum water fill level. Use the maximum test load size as specified in Table 5.1 of this appendix.
3.3.2 Minimum test load and water fill. Measure the values for hot water consumption (Hmn), cold water consumption (Cmn), and electrical energy consumption (Emn) for an Extra-Hot Wash/Cold Rinse cycle, with the controls set for the minimum water fill level. Use the minimum test load size as specified in Table 5.1 of this appendix.
3.3.3 Average test load and water fill. For a clothes washer with an automatic water fill control system, measure the values for hot water consumption (Hma), cold water consumption (Cma), and electrical energy consumption (Ema) for an Extra-Hot Wash/Cold Rinse cycle. Use the average test load size as specified in Table 5.1 of this appendix.
3.4 Hot Wash/Cold Rinse. Measure the water and electrical energy consumption for each water fill level and test load size as specified in sections 3.4.1 through 3.4.3 of this appendix for the Hot Wash/Cold Rinse temperature selection, as defined within the energy test cycle.
3.4.1 Maximum test load and water fill. Measure the values for hot water consumption (HhX), cold water consumption (ChX), and electrical energy consumption (EhX) for a Hot Wash/Cold Rinse cycle, with the controls set for the maximum water fill level. Use the maximum test load size as specified in Table 5.1 of this appendix.
3.4.2 Minimum test load and water fill. Measure the values for hot water consumption (Hhn), cold water consumption (Chn), and electrical energy consumption (Ehn) for a Hot Wash/Cold Rinse cycle, with the controls set for the minimum water fill level. Use the minimum test load size as specified in Table 5.1 of this appendix.
3.4.3 Average test load and water fill. For a clothes washer with an automatic water fill control system, measure the values for hot water consumption (Hha), cold water consumption (Cha), and electrical energy consumption (Eha) for a Hot Wash/Cold Rinse cycle. Use the average test load size as specified in Table 5.1 of this appendix.
3.5 Warm Wash/Cold Rinse. Measure the water and electrical energy consumption for each water fill level and test load size as specified in sections 3.5.1 through 3.5.3 of this appendix for the applicable Warm Wash/Cold Rinse temperature selection(s), as defined within the energy test cycle.
For a clothes washer with fewer than four discrete Warm Wash/Cold Rinse temperature selections, test all Warm Wash/Cold Rinse selections. For a clothes washer that offers four or more Warm Wash/Cold Rinse selections, test at all discrete selections, or test at the 25 percent, 50 percent, and 75 percent positions of the temperature selection device between the hottest hot (≤135 °F (57.2 °C)) wash and the coldest cold wash. If a selection is not available at the 25, 50 or 75 percent position, in place of each such unavailable selection, use the next warmer setting. For each reportable value to be used for the Warm Wash/Cold Rinse temperature selection, calculate the average of all Warm Wash/Cold Rinse temperature selections tested pursuant to this section.
3.5.1 Maximum test load and water fill. Measure the values for hot water consumption (HwX), cold water consumption (CwX), and electrical energy consumption (EwX) for the Warm Wash/Cold Rinse cycle, with the controls set for the maximum water fill level. Use the maximum test load size as specified in Table 5.1 of this appendix.
3.5.2 Minimum test load and water fill. Measure the values for hot water consumption (Hwn), cold water consumption (Cwn), and electrical energy consumption (Ewn) for the Warm Wash/Cold Rinse cycle, with the controls set for the minimum water fill level. Use the minimum test load size as specified in Table 5.1 of this appendix.
3.5.3 Average test load and water fill. For a clothes washer with an automatic water fill control system, measure the values for hot water consumption (Hwa), cold water consumption (Cwa), and electrical energy consumption (Ewa) for a Warm Wash/Cold Rinse cycle. Use the average test load size as specified in Table 5.1 of this appendix.
3.6 Warm Wash/Warm Rinse. Measure the water and electrical energy consumption for each water fill level and/or test load size as specified in sections 3.6.1 through 3.6.3 of this appendix for the applicable Warm Wash/Warm Rinse temperature selection(s), as defined within the energy test cycle. For a clothes washer with fewer than four discrete Warm Wash/Warm Rinse temperature selections, test all Warm Wash/Warm Rinse selections. For a clothes washer that offers four or more Warm Wash/Warm Rinse selections, test at all discrete selections, or test at 25 percent, 50 percent, and 75 percent positions of the temperature selection device between the hottest hot (≤ 135 °F (57.2 °C)) wash and the coldest cold wash. If a selection is not available at the 25, 50 or 75 percent position, in place of each such unavailable selection use the next warmer setting. For each reportable value to be used for the Warm Wash/Warm Rinse temperature selection, calculate the average of all Warm Wash/Warm Rinse temperature selections tested pursuant to this section.
3.6.1 Maximum test load and water fill. Measure the values for hot water consumption (HwwX), cold water consumption (CwwX), and electrical energy consumption (EwwX) for the Warm Wash/Warm Rinse cycle, with the controls set for the maximum water fill level. Use the maximum test load size as specified in Table 5.1 of this appendix.
3.6.2 Minimum test load and water fill. Measure the values for hot water consumption (Hwwn), cold water consumption (Cwwn), and electrical energy consumption (Ewwn) for the Warm Wash/Warm Rinse cycle, with the controls set for the minimum water fill level. Use the minimum test load size as specified in Table 5.1 of this appendix.
3.6.3 Average test load and water fill. For a clothes washer with an automatic water fill control system, measure the values for hot water consumption (Hwwa), cold water consumption (Cwwa), and electrical energy consumption (Ewwa) for the Warm Wash/Warm Rinse cycle. Use the average test load size as specified in Table 5.1 of this appendix.
3.7 Cold Wash/Cold Rinse. Measure the water and electrical energy consumption for each water fill level and test load size as specified in sections 3.7.1 through 3.7.3 of this appendix for the applicable Cold Wash/Cold Rinse temperature selection, as defined within the energy test cycle.
3.7.1 Maximum test load and water fill. Measure the values for hot water consumption (HcX), cold water consumption (CcX), and electrical energy consumption (EcX) for a Cold Wash/Cold Rinse cycle, with the controls set for the maximum water fill level. Use the maximum test load size as specified in Table 5.1 of this appendix.
3.7.2 Minimum test load and water fill. Measure the values for hot water consumption (Hcn), cold water consumption (Ccn), and electrical energy consumption (Ecn) for a Cold Wash/Cold Rinse cycle, with the controls set for the minimum water fill level. Use the minimum test load size as specified in Table 5.1 of this appendix.
3.7.3 Average test load and water fill. For a clothes washer with an automatic water fill control system, measure the values for hot water consumption (Hca), cold water consumption (Cca), and electrical energy consumption (Eca) for a Cold Wash/Cold Rinse cycle. Use the average test load size as specified in Table 5.1 of this appendix.
3.8 Remaining moisture content (RMC).
3.8.1 The wash temperature must be the same as the rinse temperature for all testing. Use the maximum test load as defined in Table 5.1 of this appendix for testing.
3.8.2 Clothes washers with cold rinse only.
3.8.2.1 Record the actual “bone dry” weight of the test load (WIX), then place the test load in the clothes washer.
3.8.2.2 Set the water level controls to maximum fill.
3.8.2.3 Run the Cold Wash/Cold Rinse cycle.
3.8.2.4 Record the weight of the test load immediately after completion of the wash cycle (WCX).
3.8.2.5 Calculate the remaining moisture content of the maximum test load, RMCX, defined as:
RMCX = (WCX − WIX)/WIX
3.8.2.6 Apply the RMC correction curve described in section 9 of appendix J3 to this subpart to calculate the corrected remaining moisture content, RMCcorr, expressed as a percentage as follows:
RMCcorr = (A × RMCX + B) × 100%
where:
A and B are the coefficients of the RMC correction curve as defined in section 8.7 of appendix J3 to this subpart.
RMCX = As defined in section 3.8.2.5 of this appendix.
3.8.2.7 Use RMCcorr as the final corrected RMC in section 4.3 of this appendix.
3.8.3 Clothes washers with both cold and warm rinse options.
3.8.3.1 Complete sections 3.8.2.1 through 3.8.2.4 of this appendix for a Cold Wash/Cold Rinse cycle. Calculate the remaining moisture content of the maximum test load for Cold Wash/Cold Rinse, RMCCOLD, defined as:
RMCCOLD = (WCX − WIX)/WIX
3.8.3.2 Apply the RMC correction curve described in section 9 of appendix J3 to this subpart to calculate the corrected remaining moisture content for Cold Wash/Cold Rinse, RMCCOLD,corr, expressed as a percentage, as follows:
RMCCOLD,corr = (A × RMCCOLD + B) × 100%
where:
A and B are the coefficients of the RMC correction curve as defined in section 8.7 of appendix J3 to this subpart.
RMCCOLD = As defined in section 3.8.3.1 of this appendix.
3.8.3.3 Complete sections 3.8.2.1 through 3.8.2.4 of this appendix using a Warm Wash/Warm Rinse cycle instead. Calculate the remaining moisture content of the maximum test load for Warm Wash/Warm Rinse, RMCWARM, defined as:
RMCWARM = (WCX−WIX)/WIX
3.8.3.4 Apply the RMC correction curve described in section 9 of appendix J3 to this subpart to calculate the corrected remaining moisture content for Warm Wash/Warm Rinse, RMCWARM,corr, expressed as a percentage, as follows:
RMCWARM,corr = (A × RMCWARM + B) × 100%
where:
A and B are the coefficients of the RMC correction curve as defined in section 8.7 of appendix J3 to this subpart.
RMCWARM = As defined in section 3.8.3.3 of this appendix.
3.8.3.5 Calculate the corrected remaining moisture content of the maximum test load, RMCcorr, expressed as a percentage as follows:
RMCcorr = RMCCOLD,corr × (1 − TUFww) + RMCWARM,corr × (TUFww)
where:
RMCCOLD,corr = As defined in section 3.8.3.2 of this Appendix.
RMCWARM,corr = As defined in section 3.8.3.4 of this Appendix.
TUFww is the temperature use factor for Warm Wash/Warm Rinse as defined in Table 4.1.1 of this appendix.
3.8.3.6 Use RMCcorr as calculated in section 3.8.3.5 as the final corrected RMC used in section 4.3 of this appendix.
3.8.4 Clothes washers that have options such as multiple selections of spin speeds or spin times that result in different RMC values, and that are available within the energy test cycle.
3.8.4.1 Complete sections 3.8.2 or 3.8.3 of this appendix, as applicable, using the maximum and minimum extremes of the available spin options, excluding any “no spin” (zero spin speed) settings. Combine the calculated values RMCcorr,max extraction and RMCcorr,min extraction at the maximum and minimum settings, respectively, as follows:
RMCcorr = 0.75 × RMCcorr,max extraction + 0.25 × RMCcorr,min extraction
where:
RMCcorr, max extraction is the corrected remaining moisture content using the maximum spin setting, calculated according to section 3.8.2 or 3.8.3 of this appendix, as applicable.
RMCcorr, min extraction is the corrected remaining moisture content using the minimum spin setting, calculated according to section 3.8.2 or 3.8.3 of this appendix, as applicable.
3.8.4.2 Use RMCcorr as calculated in section 3.8.4.1 as the final corrected RMC used in section 4.3 of this appendix.
3.8.5 The procedure for calculating the corrected RMC as described in section 3.8.2, 3.8.3, or 3.8.4 of this appendix may be replicated twice in its entirety, for a total of three independent corrected RMC measurements. If three replications of the RMC measurement are performed, use the average of the three corrected RMC measurements as the final corrected RMC in section 4.3 of this appendix.
3.9 Combined low-power mode power. Connect the clothes washer to a watt meter as specified in section 2.5.3 of this appendix. Establish the testing conditions set forth in sections 2.1, 2.4, and 2.10 of this appendix.
3.9.1 Perform combined low-power mode testing after completion of an active mode wash cycle included as part of the energy test cycle; after removing the test load; without changing the control panel settings used for the active mode wash cycle; with the door closed; and without disconnecting the electrical energy supply to the clothes washer between completion of the active mode wash cycle and the start of combined low-power mode testing.
3.9.2 For a clothes washer that takes some time to automatically enter a stable inactive mode or off mode state from a higher power state as discussed in Section 5, Paragraph 5.1, note 1 of IEC 62301 (incorporated by reference; see § 430.3), allow sufficient time for the clothes washer to automatically reach the default inactive/off mode state before proceeding with the test measurement.
3.9.3 Once the stable inactive/off mode state has been reached, measure and record the default inactive/off mode power, Pdefault, in watts, following the test procedure for the sampling method specified in Section 5, Paragraph 5.3.2 of IEC 62301.
3.9.4 For a clothes washer with a switch, dial, or button that can be optionally selected by the end user to achieve a lower-power inactive/off mode state than the default inactive/off mode state measured in section 3.9.3 of this appendix, after performing the measurement in section 3.9.3, activate the switch, dial, or button to the position resulting in the lowest power consumption and repeat the measurement procedure described in section 3.9.3. Measure and record the lowest-power inactive/off mode power, Plowest, in Watts.
3.10 Energy consumption for the purpose of determining the cycle selection(s) to be included in the energy test cycle. This section is implemented only in cases where the energy test cycle flowcharts in section 2.12 require the determination of the wash/rinse temperature selection with the highest energy consumption.
3.10.1 For the wash/rinse temperature selection being considered under this section, establish the testing conditions set forth in section 2 of this appendix. Select the applicable cycle selection and wash/rinse temperature selection. For all wash/rinse temperature selections, the manufacturer default settings shall be used as described in section 3.2.7 of this appendix.
3.10.2 Use the clothes washer's maximum test load size, determined from Table 5.1 of this appendix, for testing under this section.
3.10.3 For clothes washers with a manual fill control system, user-adjustable automatic water fill control system, or automatic water fill control system with alternate manual water fill control system, use the water fill selector setting resulting in the maximum water level available for each cycle selection for testing under this section.
3.10.4 Each wash cycle tested under this section shall include the entire active washing mode and exclude any delay start or cycle finished modes.
3.10.5 Measure each wash cycle's electrical energy consumption (EX) and hot water consumption (HX). Calculate the total energy consumption for each cycle selection (ETX), as follows:
ETX = EX + (HX × T × K)
where:
EX is the electrical energy consumption, expressed in kilowatt-hours per cycle.
HX is the hot water consumption, expressed in gallons per cycle.
T = nominal temperature rise = 75 °F (41.7 °C).
K = Water specific heat in kilowatt-hours per gallon per degree F = 0.00240 kWh/gal - °F (0.00114 kWh/L- °C).
4. Calculation of Derived Results From Test Measurements
4.1 Hot water and machine electrical energy consumption of clothes washers.
4.1.1 Per-cycle temperature-weighted hot water consumption for all maximum, average, and minimum water fill levels tested. Calculate the per-cycle temperature-weighted hot water consumption for the maximum water fill level, VhX, the average water fill level, Vha, and the minimum water fill level, Vhn, expressed in gallons per cycle (or liters per cycle) and defined as:
(a) VhX = [HmX × TUFm] + [HhX × TUFh] + [HwX × TUFw] + [HwwX × TUFww] + [HcX × TUFc]
(b) Vha = [Hma × TUFm] + [Hha × TUFh] + [Hwa × TUFw] + [Hwwa × TUFww] + [Hca × TUFc]
(c) Vhn = [Hmn × TUFm] + [Hhn × TUFh] + [Hwn × TUFw] + [Hwwn × TUFww] + [Hcn × TUFc]
where:
HmX, Hma, and Hmn, are reported hot water consumption values, in gallons per-cycle (or liters per cycle), at maximum, average, and minimum water fill levels, respectively, for the Extra-Hot Wash/Cold Rinse cycle, as measured in sections 3.3.1 through 3.3.3 of this appendix.
HhX, Hha, and Hhn, are reported hot water consumption values, in gallons per-cycle (or liters per cycle), at maximum, average, and minimum water fill levels, respectively, for the Hot Wash/Cold Rinse cycle, as measured in sections 3.4.1 through 3.4.3 of this appendix.
HwX, Hwa, and Hwn, are reported hot water consumption values, in gallons per-cycle (or liters per cycle), at maximum, average, and minimum water fill levels, respectively, for the Warm Wash/Cold Rinse cycle, as measured in sections 3.5.1 through 3.5.3 of this appendix.
HwwX, Hwwa, and Hwwn, are reported hot water consumption values, in gallons per-cycle (or liters per cycle), at maximum, average, and minimum water fill levels, respectively, for the Warm Wash/Warm Rinse cycle, as measured in sections 3.6.1 through 3.6.3 of this appendix.
HcX, Hca, and Hcn, are reported hot water consumption values, in gallons per-cycle (or liters per cycle), at maximum, average, and minimum water fill levels, respectively, for the Cold Wash/Cold Rinse cycle, as measured in sections 3.7.1 through 3.7.3 of this appendix.
TUFm, TUFh, TUFw, TUFww, and TUFc are temperature use factors for Extra-Hot Wash/Cold Rinse, Hot Wash/Cold Rinse, Warm Wash/Cold Rinse, Warm Wash/Warm Rinse, and Cold Wash/Cold Rinse temperature selections, respectively, as defined in Table 4.1.1 of this appendix.
Table 4.1.1 - Temperature Use Factors
Wash/Rinse Temperature Selections Available in the Energy Test Cycle Clothes washers with cold rinse only Clothes washers with both cold and warm rinse C/C H/C
C/CH/C
W/C
C/CXH/C
H/C
C/CXH/C
H/C
W/C
C/CH/C
W/C
W/W
C/CXH/C
H/C
W/W
C/CXH/C
H/C
W/C
W/W
C/CTUFm (Extra-Hot/Cold) 0.14 0.05 0.14 0.05 TUFh (Hot/Cold) 0.63 0.14 * 0.49 0.09 0.14 * 0.22 0.09 TUFw (Warm/Cold) 0.49 0.49 0.22 0.22 TUFww (Warm/Warm) 0.27 0.27 0.27 TUFc (Cold/Cold) 1.00 0.37 0.37 0.37 0.37 0.37 0.37 0.37 4.1.2 Total per-cycle hot water energy consumption for all maximum, average, and minimum water fill levels tested. Calculate the total per-cycle hot water energy consumption for the maximum water fill level, HEmax, the average water fill level, HEavg, and the minimum water fill level, HEmin, expressed in kilowatt-hours per cycle and defined as:
(a) HEmax = [VhX × T × K] = Total energy when a maximum load is tested.
(b) HEavg = [Vha × T × K] = Total energy when an average load is tested.
(c) HEmin = [Vhn × T × K] = Total energy when a minimum load is tested.
where:
VhX, Vha, and Vhn are defined in section 4.1.1 of this appendix.
T = Temperature rise = 75 °F (41.7 °C).
K = Water specific heat in kilowatt-hours per gallon per degree F = 0.00240 kWh/gal- °F (0.00114 kWh/L- °C).
4.1.3 Total weighted per-cycle hot water energy consumption. Calculate the total weighted per-cycle hot water energy consumption, HET, expressed in kilowatt-hours per cycle and defined as:
HET = [HEmax × Fmax] + [HEavg × Favg] + HEmin × Fmin]
where:
HEmax, HEavg, and HEmin are defined in section 4.1.2 of this appendix.
Fmax, Favg, and Fmin are the load usage factors for the maximum, average, and minimum test loads based on the size and type of the control system on the washer being tested, as defined in Table 4.1.3 of this appendix.
Table 4.1.3 - Load Usage Factors
Load usage factor Water fill control system Manual Automatic Fmax = 0.72 0.12 Favg = 0.74 Fmin = 0.28 0.14 4.1.4 Total per-cycle hot water energy consumption using gas-heated or oil-heated water, for product labeling requirements. Calculate for the energy test cycle the per-cycle hot water consumption, HETG, using gas-heated or oil-heated water, expressed in Btu per cycle (or megajoules per cycle) and defined as:
HETG = HET × 1/e × 3412 Btu/kWh or HETG = HET × 1/e × 3.6 MJ/kWh
where:
e = Nominal gas or oil water heater efficiency = 0.75.
HET = As defined in section 4.1.3 of this Appendix.
4.1.5 Per-cycle machine electrical energy consumption for all maximum, average, and minimum test load sizes. Calculate the total per-cycle machine electrical energy consumption for the maximum water fill level, MEmax, the average water fill level, MEavg, and the minimum water fill level, MEmin, expressed in kilowatt-hours per cycle and defined as:
(a) MEmax = [EmX × TUFm] + [EhX × TUFh] + [EwX × TUFw] + [EwwX × TUFww] + [EcX × TUFc]
(b) MEavg = [Ema × TUFm] + [Eha × TUFh] + [Ewa × TUFw] + [Ewwa × TUFww] + [Eca × TUFc]
(c) MEmin = [Emn × TUFm] + [Ehn × TUFh] + [Ewn × TUFw] + [Ewwn × TUFww] + [Ecn × TUFc]
where:
EmX, Ema, and Emn, are reported electrical energy consumption values, in kilowatt-hours per cycle, at maximum, average, and minimum test loads, respectively, for the Extra-Hot Wash/Cold Rinse cycle, as measured in sections 3.3.1 through 3.3.3 of this appendix.
EhX, Eha, and Ehn, are reported electrical energy consumption values, in kilowatt-hours per cycle, at maximum, average, and minimum test loads, respectively, for the Hot Wash/Cold Rinse cycle, as measured in sections 3.4.1 through 3.4.3 of this appendix.
EwX, Ewa, and Ewn, are reported electrical energy consumption values, in kilowatt-hours per cycle, at maximum, average, and minimum test loads, respectively, for the Warm Wash/Cold Rinse cycle, as measured in sections 3.5.1 through 3.5.3 of this appendix.
EwwX, Ewwa, and Ewwn, are reported electrical energy consumption values, in kilowatt-hours per cycle, at maximum, average, and minimum test loads, respectively, for the Warm Wash/Warm Rinse cycle, as measured in sections 3.6.1 through 3.6.3 of this appendix.
EcX, Eca, and Ecn, are reported electrical energy consumption values, in kilowatt-hours per cycle, at maximum, average, and minimum test loads, respectively, for the Cold Wash/Cold Rinse cycle, as measured in sections 3.7.1 through 3.7.3 of this appendix.
TUFm, TUFh, TUFw, TUFww, and TUFc are defined in Table 4.1.1 of this appendix.
4.1.6 Total weighted per-cycle machine electrical energy consumption. Calculate the total weighted per-cycle machine electrical energy consumption, MET, expressed in kilowatt-hours per cycle and defined as:
MET = [MEmax × Fmax] + [MEavg × Favg] + [MEmin × Fmin]
where:
MEmax, MEavg, and MEmin are defined in section 4.1.5 of this appendix.
Fmax, Favg, and Fmin are defined in Table 4.1.3 of this appendix.
4.1.7 Total per-cycle energy consumption when electrically heated water is used. Calculate the total per-cycle energy consumption, ETE, using electrically heated water, expressed in kilowatt-hours per cycle and defined as:
ETE = HET + MET
where:
MET = As defined in section 4.1.6 of this appendix.
HET = As defined in section 4.1.3 of this appendix.
4.2 Water consumption of clothes washers.
4.2.1 Per-cycle water consumption for Extra-Hot Wash/Cold Rinse. Calculate the maximum, average, and minimum total water consumption, expressed in gallons per cycle (or liters per cycle), for the Extra-Hot Wash/Cold Rinse cycle and defined as:
Qmmax = [HmX + CmX]
Qmavg = [Hma + Cma]
Qmmin = [Hmn + Cmn]
where:
HmX, CmX, Hma, Cma, Hmn, and Cmn are defined in section 3.3 of this appendix.
4.2.2 Per-cycle water consumption for Hot Wash/Cold Rinse. Calculate the maximum, average, and minimum total water consumption, expressed in gallons per cycle (or liters per cycle), for the Hot Wash/Cold Rinse cycle and defined as:
Qhmax = [HhX + ChX]
Qhavg = [Hha + Cha]
Qhmin = [Hhn + Chn]
where:
HhX, ChX, Hha, Cha, Hhn, and Chn are defined in section 3.4 of this appendix.
4.2.3 Per-cycle water consumption for Warm Wash/Cold Rinse. Calculate the maximum, average, and minimum total water consumption, expressed in gallons per cycle (or liters per cycle), for the Warm Wash/Cold Rinse cycle and defined as:
Qwmax = [HwX + CwX]
Qwavg = [Hwa + Cwa]
Qwmin = [Hwn + Cwn]
where:
HwX, CwX, Hwa, Cwa, Hwn, and Cwn are defined in section 3.5 of this appendix.
4.2.4 Per-cycle water consumption for Warm Wash/Warm Rinse. Calculate the maximum, average, and minimum total water consumption, expressed in gallons per cycle (or liters per cycle), for the Warm Wash/Warm Rinse cycle and defined as:
Qwwmax = [HwwX + CwwX]
Qwwavg = [Hwwa + Cwwa]
Qwwmin = [Hwwn + Cwwn]
where:
HwwX, CwwX, Hwwa, Cwwa, Hwwn, and Cwwn are defined in section 3.6 of this appendix.
4.2.5 Per-cycle water consumption for Cold Wash/Cold Rinse. Calculate the maximum, average, and minimum total water consumption, expressed in gallons per cycle (or liters per cycle), for the Cold Wash/Cold Rinse cycle and defined as:
Qcmax = [HcX + CcX]
Qcavg = [Hca + Cca]
Qcmin = [Hcn + Ccn]
where:
HcX, CcX, Hca, Cca, Hcn, and Ccn are defined in section 3.7 of this appendix.
4.2.6 Total weighted per-cycle water consumption for Extra-Hot Wash/Cold Rinse. Calculate the total weighted per-cycle water consumption for the Extra-Hot Wash/Cold Rinse cycle, QmT, expressed in gallons per cycle (or liters per cycle) and defined as:
QmT = [Qmmax × Fmax] + [Qmavg × Favg] + [Qmmin × Fmin]
where:
Qmmax, Qmavg, Qmmin are defined in section 4.2.1 of this appendix.
Fmax, Favg, Fmin are defined in Table 4.1.3 of this appendix.
4.2.7 Total weighted per-cycle water consumption for Hot Wash/Cold Rinse. Calculate the total weighted per-cycle water consumption for the Hot Wash/Cold Rinse cycle, QhT, expressed in gallons per cycle (or liters per cycle) and defined as:
QhT = [Qhmax × Fmax] + [Qhavg × Favg] + [Qhmin × Fmin]
where:
Qhmax, Qhavg, Qhmin are defined in section 4.2.2 of this appendix.
Fmax, Favg, Fmin are defined in Table 4.1.3 of this appendix.
4.2.8 Total weighted per-cycle water consumption for Warm Wash/Cold Rinse. Calculate the total weighted per-cycle water consumption for the Warm Wash/Cold Rinse cycle, QwT, expressed in gallons per cycle (or liters per cycle) and defined as:
QwT = [Qwmax × Fmax] + [Qwavg × Favg] + [Qwmin × Fmin]
where:
Qwmax, Qwavg, Qwmin are defined in section 4.2.3 of this appendix.
Fmax, Favg, Fmin are defined in Table 4.1.3 of this appendix.
4.2.9 Total weighted per-cycle water consumption for Warm Wash/Warm Rinse. Calculate the total weighted per-cycle water consumption for the Warm Wash/Warm Rinse cycle, QwwT, expressed in gallons per cycle (or liters per cycle) and defined as:
QwwT = [Qwwmax × Fmax] + [Qwwavg × Favg] + [Qwwmin × Fmin]
where:
Qwwmax, Qwwavg, Qwwmin are defined in section 4.2.4 of this appendix.
Fmax, Favg, Fmin are defined in Table 4.1.3 of this appendix.
4.2.10 Total weighted per-cycle water consumption for Cold Wash/Cold Rinse. Calculate the total weighted per-cycle water consumption for the Cold Wash/Cold Rinse cycle, QcT, expressed in gallons per cycle (or liters per cycle) and defined as:
QcT = [Qcmax × Fmax] + [Qcavg × Favg] + [Qcmin × Fmin]
where:
Qcmax, Qcavg, Qcmin are defined in section 4.2.5 of this appendix.
Fmax, Favg, Fmin are defined in Table 4.1.3 of this appendix.
4.2.11 Total weighted per-cycle water consumption for all wash cycles. Calculate the total weighted per-cycle water consumption for all wash cycles, QT, expressed in gallons per cycle (or liters per cycle) and defined as:
QT = [QmT × TUFm] + [QhT × TUFh] + [QwT × TUFw] + [QwwT × TUFww] + [QcT × TUFc]
where:
QmT, QhT, QwT, QwwT, and QcT are defined in sections 4.2.6 through 4.2.10 of this appendix.
TUFm, TUFh, TUFw, TUFww, and TUFc are defined in Table 4.1.1 of this appendix.
4.2.12 Integrated water factor. Calculate the integrated water factor, IWF, expressed in gallons per cycle per cubic foot (or liters per cycle per liter), as:
IWF = QT/C
where:
QT = As defined in section 4.2.11 of this appendix.
C = As defined in section 3.1.7 of this appendix.
4.3 Per-cycle energy consumption for removal of moisture from test load. Calculate the per-cycle energy required to remove the remaining moisture of the test load, DE, expressed in kilowatt-hours per cycle and defined as:
DE = [(Fmax × Maximum test load weight) + (Favg × Average test load weight) + (Fmin × Minimum test load weight)] × (RMCcorr - 4%) × (DEF) × (DUF)
where:
Fmax, Favg, and Fmin are defined in Table 4.1.3 of this appendix.
Maximum, average, and minimum test load weights are defined in Table 5.1 of this appendix.
RMCcorr = As defined in section 3.8.2.6, 3.8.3.5, or 3.8.4.1 of this Appendix.
DEF = Nominal energy required for a clothes dryer to remove moisture from clothes = 0.5 kWh/lb (1.1 kWh/kg).
DUF = Dryer usage factor, percentage of washer loads dried in a clothes dryer = 0.91.
4.4 Per-cycle combined low-power mode energy consumption. Calculate the per-cycle combined low-power mode energy consumption, ETLP, expressed in kilowatt-hours per cycle and defined as:
ETLP = [(Pdefault × Sdefault) + (Plowest × Slowest)] × Kp/295
where:
Pdefault = Default inactive/off mode power, in watts, as measured in section 3.9.3 of this appendix.
Plowest = Lowest-power inactive/off mode power, in watts, as measured in section 3.9.4 of this appendix for clothes washers with a switch, dial, or button that can be optionally selected by the end user to achieve a lower-power inactive/off mode than the default inactive/off mode; otherwise, Plowest=0.
Sdefault= Annual hours in default inactive/off mode, defined as 8,465 if no optional lowest-power inactive/off mode is available; otherwise 4,232.5.
Slowest= Annual hours in lowest-power inactive/off mode, defined as 0 if no optional lowest-power inactive/off mode is available; otherwise 4,232.5.
Kp = Conversion factor of watt-hours to kilowatt-hours = 0.001.
295 = Representative average number of clothes washer cycles in a year.
8,465 = Combined annual hours for inactive and off mode.
4,232.5 = One-half of the combined annual hours for inactive and off mode.
4.5 Modified energy factor. Calculate the modified energy factor, MEFJ2, expressed in cubic feet per kilowatt-hour per cycle (or liters per kilowatt-hour per cycle) and defined as:
MEFJ2 = C/(ETE + DE)
where:
C = As defined in section 3.1.7 of this appendix.
ETE = As defined in section 4.1.7 of this appendix.
DE = As defined in section 4.3 of this appendix.
4.6 Integrated modified energy factor. Calculate the integrated modified energy factor, IMEF, expressed in cubic feet per kilowatt-hour per cycle (or liters per kilowatt-hour per cycle) and defined as:
IMEF = C/(ETE + DE + ETLP)
where:
C = As defined in section 3.1.7 of this appendix.
ETE = As defined in section 4.1.7 of this appendix.
DE = As defined in section 4.3 of this appendix.
ETLP = As defined in section 4.4 of this appendix.
5. Test Loads
Table 5.1 - Test Load Sizes
Container volume Minimum load Maximum load Average load cu. ft. liter lb kg lb kg lb kg ≥ < ≥ < 0.00-0.80 0.00-22.7 3.00 1.36 3.00 1.36 3.00 1.36 0.80-0.90 22.7-25.5 3.00 1.36 3.50 1.59 3.25 1.47 0.90-1.00 25.5-28.3 3.00 1.36 3.90 1.77 3.45 1.56 1.00-1.10 28.3-31.1 3.00 1.36 4.30 1.95 3.65 1.66 1.10-1.20 31.1-34.0 3.00 1.36 4.70 2.13 3.85 1.75 1.20-1.30 34.0-36.8 3.00 1.36 5.10 2.31 4.05 1.84 1.30-1.40 36.8-39.6 3.00 1.36 5.50 2.49 4.25 1.93 1.40-1.50 39.6-42.5 3.00 1.36 5.90 2.68 4.45 2.02 1.50-1.60 42.5-45.3 3.00 1.36 6.40 2.90 4.70 2.13 1.60-1.70 45.3-48.1 3.00 1.36 6.80 3.08 4.90 2.22 1.70-1.80 48.1-51.0 3.00 1.36 7.20 3.27 5.10 2.31 1.80-1.90 51.0-53.8 3.00 1.36 7.60 3.45 5.30 2.40 1.90-2.00 53.8-56.6 3.00 1.36 8.00 3.63 5.50 2.49 2.00-2.10 56.6-59.5 3.00 1.36 8.40 3.81 5.70 2.59 2.10-2.20 59.5-62.3 3.00 1.36 8.80 3.99 5.90 2.68 2.20-2.30 62.3-65.1 3.00 1.36 9.20 4.17 6.10 2.77 2.30-2.40 65.1-68.0 3.00 1.36 9.60 4.35 6.30 2.86 2.40-2.50 68.0-70.8 3.00 1.36 10.00 4.54 6.50 2.95 2.50-2.60 70.8-73.6 3.00 1.36 10.50 4.76 6.75 3.06 2.60-2.70 73.6-76.5 3.00 1.36 10.90 4.94 6.95 3.15 2.70-2.80 76.5-79.3 3.00 1.36 11.30 5.13 7.15 3.24 2.80-2.90 79.3-82.1 3.00 1.36 11.70 5.31 7.35 3.33 2.90-3.00 82.1-85.0 3.00 1.36 12.10 5.49 7.55 3.42 3.00-3.10 85.0-87.8 3.00 1.36 12.50 5.67 7.75 3.52 3.10-3.20 87.8-90.6 3.00 1.36 12.90 5.85 7.95 3.61 3.20-3.30 90.6-93.4 3.00 1.36 13.30 6.03 8.15 3.70 3.30-3.40 93.4-96.3 3.00 1.36 13.70 6.21 8.35 3.79 3.40-3.50 96.3-99.1 3.00 1.36 14.10 6.40 8.55 3.88 3.50-3.60 99.1-101.9 3.00 1.36 14.60 6.62 8.80 3.99 3.60-3.70 101.9-104.8 3.00 1.36 15.00 6.80 9.00 4.08 3.70-3.80 104.8-107.6 3.00 1.36 15.40 6.99 9.20 4.17 3.80-3.90 107.6-110.4 3.00 1.36 15.80 7.16 9.40 4.26 3.90-4.00 110.4-113.3 3.00 1.36 16.20 7.34 9.60 4.35 4.00-4.10 113.3-116.1 3.00 1.36 16.60 7.53 9.80 4.45 4.10-4.20 116.1-118.9 3.00 1.36 17.00 7.72 10.00 4.54 4.20-4.30 118.9-121.8 3.00 1.36 17.40 7.90 10.20 4.63 4.30-4.40 121.8-124.6 3.00 1.36 17.80 8.09 10.40 4.72 4.40-4.50 124.6-127.4 3.00 1.36 18.20 8.27 10.60 4.82 4.50-4.60 127.4-130.3 3.00 1.36 18.70 8.46 10.85 4.91 4.60-4.70 130.3-133.1 3.00 1.36 19.10 8.65 11.05 5.00 4.70-4.80 133.1-135.9 3.00 1.36 19.50 8.83 11.25 5.10 4.80-4.90 135.9-138.8 3.00 1.36 19.90 9.02 11.45 5.19 4.90-5.00 138.8-141.6 3.00 1.36 20.30 9.20 11.65 5.28 5.00-5.10 141.6-144.4 3.00 1.36 20.70 9.39 11.85 5.38 5.10-5.20 144.4-147.2 3.00 1.36 21.10 9.58 12.05 5.47 5.20-5.30 147.2-150.1 3.00 1.36 21.50 9.76 12.25 5.56 5.30-5.40 150.1-152.9 3.00 1.36 21.90 9.95 12.45 5.65 5.40-5.50 152.9-155.7 3.00 1.36 22.30 10.13 12.65 5.75 5.50-5.60 155.7-158.6 3.00 1.36 22.80 10.32 12.90 5.84 5.60-5.70 158.6-161.4 3.00 1.36 23.20 10.51 13.10 5.93 5.70-5.80 161.4-164.2 3.00 1.36 23.60 10.69 13.30 6.03 5.80-5.90 164.2-167.1 3.00 1.36 24.00 10.88 13.50 6.12 5.90-6.00 167.1-169.9 3.00 1.36 24.40 11.06 13.70 6.21 6.00-6.10 169.9-172.7 3.00 1.36 24.80 11.25 13.90 6.30 6.10-6.20 172.7-175.6 3.00 1.36 25.20 11.43 14.10 6.40 6.20-6.30 175.6-178.4 3.00 1.36 25.60 11.61 14.30 6.49 6.30-6.40 178.4-181.2 3.00 1.36 26.00 11.79 14.50 6.58 6.40-6.50 181.2-184.1 3.00 1.36 26.40 11.97 14.70 6.67 6.50-6.60 184.1-186.9 3.00 1.36 26.90 12.20 14.95 6.78 6.60-6.70 186.9-189.7 3.00 1.36 27.30 12.38 15.15 6.87 6.70-6.80 189.7-192.6 3.00 1.36 27.70 12.56 15.35 6.96 6.80-6.90 192.6-195.4 3.00 1.36 28.10 12.75 15.55 7.05 6.90-7.00 195.4-198.2 3.00 1.36 28.50 12.93 15.75 7.14 7.00-7.10 198.2-201.0 3.00 1.36 28.90 13.11 15.95 7.23 7.10-7.20 201.0-203.9 3.00 1.36 29.30 13.29 16.15 7.33 7.20-7.30 203.9-206.7 3.00 1.36 29.70 13.47 16.35 7.42 7.30-7.40 206.7-209.5 3.00 1.36 30.10 13.65 16.55 7.51 7.40-7.50 209.5-212.4 3.00 1.36 30.50 13.83 16.75 7.60 7.50-7.60 212.4-215.2 3.00 1.36 31.00 14.06 17.00 7.71 7.60-7.70 215.2-218.0 3.00 1.36 31.40 14.24 17.20 7.80 7.70-7.80 218.0-220.9 3.00 1.36 31.80 14.42 17.40 7.89 7.80-7.90 220.9-223.7 3.00 1.36 32.20 14.61 17.60 7.98 7.90-8.00 223.7-226.5 3.00 1.36 32.60 14.79 17.80 8.07 [80 FR 46767, Aug. 5, 2015; 80 FR 50757, Aug. 21, 2015, as amended at 80 FR 62443, Oct. 16, 2015; 87 FR 33395, June 1, 2022]