Code of Federal Regulations (Last Updated: February 15, 2024) |
Title 14 - Aeronautics and Space |
Chapter I - Federal Aviation Administration, Department of Transportation |
SubChapter C - Aircraft |
Part 25 - Airworthiness Standards: Transport Category Airplanes |
Subpart H - Electrical Wiring Interconnection Systems (EWIS) |
§ 25.1731 - Powerplant and APU fire detector system: EWIS.
Latest version.
-
§ 25.1731 Powerplant and APU fire detector system: EWIS.
(a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant.
(b) No EWIS component of any fire or overheat detector system for any fire zone may pass through another fire zone, unless:
(1) It is protected against the possibility of false warnings resulting from fires in zones through which it passes; or
(2) Each zone involved is simultaneously protected by the same detector and extinguishing system.
(c) EWIS that are part of each fire or overheat detector system in a fire zone must meet the requirements of § 25.1203.