Table 2 to Subpart NNNa of Part 60 - —Monitoring Requirements for Complying With 98 Weight-Percent Reduction of Total Organic Compounds Emissions or a Limit of 20 Parts per Million by Volume  


Latest version.
  • Table 2 to Subpart NNNa of Part 60—Monitoring Requirements for Complying With 98 Weight-Percent Reduction of Total Organic Compounds Emissions or a Limit of 20 Parts per Million by Volume

    Non-flare control device or
    recovery device
    Parameters to be
    monitored
    1. All control and recovery devices a. Presence of flow diverted to the atmosphere from the control and recovery device; or
    b. Monthly inspections of sealed valves
    2. Absorber a. Exit temperature of the absorbing liquid; and
    b. Exit specific gravity
    3. Boiler or process heater with a design heat input capacity less than 44 megawatts and vent stream is not introduced with or as the primary fuel Firebox temperaturea
    4. Catalytic incinerator Temperature upstream and downstream of the catalyst bed
    5. Carbon adsorber, regenerative a. Total regeneration stream mass or volumetric flow during carbon bed regeneration cycle(s); and
    b. Temperature of the carbon bed after regeneration [and within 15 minutes of completing any cooling cycle(s)]
    6. Carbon adsorber, non-regenerative or regenerated offsite Breakthrough
    7. Condenser Exit (product side) temperature
    8. Scrubber for halogenated vent streams a. pH of scrubber effluent; and
    b. Scrubber liquid and gas flow rates
    9. Thermal incinerator Firebox temperaturea
    10. Control devices other than an incinerator, boiler, process heater, or flare; or recovery devices other than an absorber, condenser, or carbon adsorber As specified by the Administrator
    a Monitor may be installed in the firebox or in the ductwork immediately downstream of the firebox before any substantial heat exchange is encountered.