Table 1 to Subpart LLLLL of Part 63 - Emission Limitations  


Latest version.
  • Table 1 to Subpart LLLLL of Part 63 - Emission Limitations

    For - You must meet the following emission limitation -
    1. Each blowing still, Group 1 asphalt loading rack, and Group 1 asphalt storage tank at existing, new, and reconstructed asphalt processing facilities; and each Group 1 asphalt storage tank at existing, new, and reconstructed asphalt roofing manufacturing lines; and each coating mixer, saturator (including wet looper), coater, sealant applicator, and adhesive applicator at new and reconstructed asphalt roofing manufacturing lines a. Reduce total hydrocarbon mass emissions by 95 percent, or to a concentration of 20 ppmv, on a dry basis corrected to 3 percent oxygen;
    b. Route the emissions to a combustion device achieving a combustion efficiency of 99.5 percent;
    c. Route the emissions to a combustion device that does not use auxiliary fuel achieving a total hydrocarbon (THC) destruction efficiency of 95.8 percent;
    d. Route the emissions to a boiler or process heater with a design heat input capacity of 44 megawatts (MW) or greater;
    e. Introduce the emissions into the flame zone of a boiler or process heater; or
    f. Route emissions to a flare meeting the requirements of § 63.11(b).
    2. The total emissions from the coating mixer, saturator (including wet looper), coater, sealant applicator, and adhesive applicator at each existing asphalt roofing manufacturing line.a a. Limit particulate matter emissions to 0.04 kilograms emissions per megagram (kg/Mg) (0.08 pounds per ton, lb/ton) of asphalt shingle or mineral-surfaced roll roofing produced; or
    b. Limit particulate matter emissions to 0.4 kg/Mg (0.8 lb/ton) of saturated felt or smooth-surfaced roll roofing produced.
    3. Each saturator (including wet looper) and coater at existing, new, and reconstructed asphalt roofing manufacturing lines.a a. Limit exhaust gases to 20 percent opacity; and
    b. Limit visible emissions from the emission capture system to 20 percent of any period of consecutive valid observations totaling 60 minutes.
    4. Each Group 2 asphalt storage tank at existing, new, and reconstructed asphalt processing facility and asphalt roofing manufacturing lines.a Limit exhaust gases to 0 percent opacity.b

    [68 FR 24577, May 7, 2003, as amended at 85 FR 14553, Mar. 12, 2020]