Table 2 to Subpart LLLLL of Part 63 - Operating Limits  


Latest version.
  • Table 2 to Subpart LLLLL of Part 63 - Operating Limits

    For - You musta
    1. Non-flare combustion devices with a design heat input capacity less than 44 MW or where the emissions are not introduced into the flame zone Maintain the 3-hour averageb combustion zone temperature at or above the operating limit established during the performance test.
    2. Flares Meet the operating requirements specified in § 63.11(b).
    3. Control devices used to comply with the particulate matter standards. a. Maintain the 3-hour average b inlet gas temperature at or below the operating limit established during the performance test; and
    b. Maintain the 3-hour average b pressure drop across the device c within the operating range limits (i.e., at or above a minimum pressure drop and at or below a maximum pressure drop) established during the performance test, or as an alternative, established according to the manufacturer's specifications as specified in § 63.8689(d).
    4. Other control devices that are neither a combustion device nor a control device used to comply with the particulate matter emission standards Maintain the approved monitoring parameters within the operating limits established during the performance test.

    [68 FR 24577, May 7, 2003, as amended at 85 FR 14553, Mar. 12, 2020]